Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mixture modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

GRUMDN: A Multi-Task Model for Predicting Human Patterns-of-Life from Stay Transition Data

Understanding human patterns-of-life (PoL) is essential towards ensuring safe and secure indoor facility environment as well as outdoor urban environment. Prediction of human movement in between places of interest is vital in understanding human PoL. Movement between spaces maybe represented and detected in one of the two forms: 1) trajectories: locations measured at regular time intervals by mobile sensors, bluetooth or GPS sensors; or 2) stay transitions: semantic PoI (points of interest) and stay duration data measurable by eventbased sensors that collect data when a check-in or check-out event is detected. Stay transition data provides a more compressed data format compared to trajectories data, especially in situations with longer stay durations, while preserving the information necessary for PoL analysis. Now as introduced briefly in the paper, our deployed end application (Digital Twin of a facility with non-player characters, besides the interactive user in virtual reality) needed a well-performing and validated AI/ML model for simulating high quality stay transitions behavior. In this study we thus primarily present our findings with developing and validating that model, which is a multi-task neural network for stay transition prediction. The neural network consists of two heads, for corresponding two tasks of stay category prediction and stay duration prediction. We evaluated gated recurrent units and multi-layer perceptrons of varying network sizes for stay category prediction; while mixture density networks, noisy generator-only networks, and generative adversarial networks of varying network sizes for stay duration prediction. We have then evaluated four multi-task models, constructed by combining these specialized models, on their ability to predict stay transition data. We tested our models on datasets from two different cases: 1) a simulation-generated dataset of indoor movement within the HFIR (high flux isotope reactor) nuclear reactor facility at Oak Ridge National Laboratory (ORNL); and 2) the GeoLife human mobility dataset of outdoor urban movement available in literature. Our results indicate that GRUMDN, which combines gated recurrent units (GRU) for stay category prediction task, and mixture density networks (MDN) for stay duration prediction task, did overall outperform other multitask models and the current state-of-the-art.

Gunaratne, Chathika [ORNL] (ORCID:0000000225088745↗

Enabling Low-Temperature (LTP) Ignition Technologies for Multi-Mode Engines through the Development of a Validated High-Fidelity LTP Model for Predicative Simulations Tools

The goal of multi-mode engine architectures is to extend current lean-burn dilution limits with renewable fuels, which requires spark plugs to deposit high energies (hundreds of mJ) in order to initiate ignition and complete combustion. At elevated energy deposition rates, spark plugs experience increased electrode erosion and thermal losses, which ultimately shortens the spark-plug lifetime and lowers ignition efficiency. As such, in order to safeguard the efficiency gains of multi-mode concepts, new and improved ignition technologies are required. Recently, non-equilibrium low-temperature plasmas (LTP) have been shown to promote energy-efficient ignition via quenching and transport of electronically excited atoms and molecules, selective radical production and fast heating of hydrocarbon/air mixtures [1-2]. Thus, LTP is seen as a technology that can potentially improve the energy extraction efficiency of fuels, while enabling kinetically controlled combustion modes towards fuel leaner conditions to realize current DOE VTO goals of improving the sustainability of future mobility [3]. Although many previous studies have demonstrated the efficacy of plasma-assisted ignition to enhance combustion, the detailed enhancement mechanisms remain largely unknown, especially for oxygenated fuels and at elevated pressures that are most relevant to practical engine conditions. These barriers hinder the development of accurate and comprehensive numerical models that seek to describe LTP-based ignition in existing engine design software tools and methods. Current state-of-the-art simulation capabilities for LTP ignition systems are in need of improvements since they deliver qualitative results only due to important limitations of existing approaches. Firstly, validated kinetic models with elementary steps for plasma discharges in oxygenated fuel/air mixtures of relevance to the transportation sector are required. Such kinetic models do not exist at present and will be developed and validated within this project. Secondly, plasma discharges and reactive mixture ignition are multi-scale, unsteady processes requiring high-performance numerical methods and software that execute efficiently on DOE supercomputers. Such software does not exist at present and will be developed and applied to practical LTP ignition scenarios as part of this project. Thirdly, experimental databases that are tailored to serve as benchmark in support of the development of predictive computational models of LTP ignition do not exist and will be part of this project.

33 ADVANCED PROPULSION SYSTEMS↗

Direct numerical simulations of turbulent reacting flows with shock waves and stiff chemistry using many-core/GPU acceleration

Compressible reacting flows may display sharp spatial variation related to shocks, contact discontinuities or reactive zones embedded within relatively smooth regions. The presence of such phenomena emphasizes the relevance of shock-capturing schemes such as the weighted essentially non-oscillatory (WENO) scheme as an essential ingredient of the numerical solver. However, these schemes are complex and have more computational cost than the simple high-order compact or non-compact schemes. In this paper, we present the implementation of a seventh-order, minimally-dissipative mapped WENO (WENO7M) scheme in a newly developed direct numerical simulation (DNS) code called KAUST Adaptive Reactive Flows Solver (KARFS). In order to make efficient use of the computer resources and reduce the solution time, without compromising the resolution requirement, the WENO routines are accelerated via graphics processing unit (GPU) computation. The performance characteristics and scalability of the code are studied using different grid sizes and block decomposition. Furthermore, the performance portability of KARFS is demonstrated on a variety of architectures including NVIDIA Tesla P100 GPUs and NVIDIA Kepler K20X GPUs. In addition, the capability and potential of the newly implemented WENO7M scheme in KARFS to perform DNS of compressible flows is also demonstrated with model problems involving shocks, isotropic turbulence, detonations and flame propagation into a stratified mixture with complex chemical kinetics.

97 MATHEMATICS AND COMPUTING↗

Prediction of the Cu oxidation state from EELS and XAS spectra using supervised machine learning

Abstract Electron energy loss spectroscopy (EELS) and X-ray absorption spectroscopy (XAS) provide detailed information about bonding, distributions and locations of atoms, and their coordination numbers and oxidation states. However, analysis of XAS/EELS data often relies on matching an unknown experimental sample to a series of simulated or experimental standard samples. This limits analysis throughput and the ability to extract quantitative information from a sample. In this work, we have trained a random forest model capable of predicting the oxidation state of copper based on its L-edge spectrum. Our model attains an R 2 score of 0.85 and a root mean square error of 0.24 on simulated data. It has also successfully predicted experimental L-edge EELS spectra taken in this work and XAS spectra extracted from the literature. We further demonstrate the utility of this model by predicting simulated and experimental spectra of mixed valence samples generated by this work. This model can be integrated into a real-time EELS/XAS analysis pipeline on mixtures of copper-containing materials of unknown composition and oxidation state. By expanding the training data, this methodology can be extended to data-driven spectral analysis of a broad range of materials.

36 MATERIALS SCIENCE↗

Solvent-induced membrane stress in biofuel production: molecular insights from small-angle scattering and all-atom molecular dynamics simulations

The disruptive effect of organic solvents on microbial membranes represents a significant challenge to the economical production of green fuels and value-added chemicals from lignocellulosic feedstocks. One route to overcoming this challenge is to engineer microbes with membranes capable of resisting organic solvent stresses. In this regard, it is useful to understand the mechanisms by which organic solvents disrupt typical biomembranes. In this study, molecular dynamics (MD) simulation, complemented by small-angle X-ray and neutron scattering (SANS/SAXS), provide a molecular-scale view of the disruption of a microbial model membrane by 1-butanol and tetrahydrofuran (THF), two common water–organic cosolvent mixtures of importance in biofuel production. Solvent interactions at the interface between the head-group and fatty acid tail regions lead to more dramatic membrane changes than interactions solely at the head-groups or tails. Although both organic solvents are found to partition into the membrane, the depth of solvent penetration into the membrane is quite different. Specifically, 1-butanol localizes near the interface between the lipid heads and tails at low concentrations, but partitions into both the head and tail regions at high concentrations. In contrast, THF, overall, partitions less than 1-butanol and prefers the lipid tail regions. Importantly, the presence of 1-butanol near the head/tail interface introduces drastic membrane changes not seen with THF. The organic solvent interactions with the lipids lead to membrane thinning and fluidization, but more so for 1-butanol than for THF. These results suggest that an aim for the future engineering of robust membranes could be to design lipid head groups that reduce the accumulation of organic solvents at the head–tail interface and that rational designs need also be cognizant of the different solvent-specific mechanisms responsible for membrane disruption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mixture density network estimation of continuous variable maximum likelihood using discrete training samples

Abstract Mixture density networks (MDNs) can be used to generate posterior density functions of model parameters $$\varvec{\theta }$$ θ given a set of observables $${\mathbf {x}}$$ x . In some applications, training data are available only for discrete values of a continuous parameter $$\varvec{\theta }$$ θ . In such situations, a number of performance-limiting issues arise which can result in biased estimates. We demonstrate the usage of MDNs for parameter estimation, discuss the origins of the biases, and propose a corrective method for each issue.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Modeling Study on Ammonia and Ammonia/Hydrogen Kinetics for Gas Turbine Engines

The use of ammonia as a fuel source in gas turbine engine power cycles represents an attractive means to decarbonize the energy sector due to higher energy density and achieving liquid state at far lower pressures compared to pure hydrogen. However, due to low flammability and a propensity for high NOx emissions, its use is not without challenge. Here, a number of 0D and 1D modeling tools were utilized to study the combustion characteristics of ammonia and ammonia/hydrogen mixtures, examining basic fundamental properties such as laminar flame speed, variability among existing chemical kinetic mechanisms, and considering the use of two-stage rich-lean combustion strategies to achieve low NOx emissions.

42 ENGINEERING↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification study of xRAGE’s multi-ion viscosity model

This report on the adequacy of the plasma viscosity model implemented in LANL’s ASC program code, xRAGE is organized as follows. Section I provides a brief introduction on the kinetic theory which underpins plasma viscosity, and Section II describes how plasma kinetic theory can be used to calculate plasma viscosity coefficients accurate within the hydrodynamic limit. Section III describes the existing model for calculating the plasma viscosity coefficient in xRAGE. Next, Section IV shows tests of the xRAGE viscosity model against established hydrodynamic theory in the case of binary and trinary plasma mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗