Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Dynamic RNA acetylation revealed by quantitative cross-evolutionary mapping

N 4 -acetylcytidine (ac 4 C) is an ancient and highly conserved RNA modification that is present on tRNA and rRNA and has recently been investigated in eukaryotic mRNA. However, the distribution, dynamics and functions of cytidine acetylation have yet to be fully elucidated. In this work, we report ac 4 C-seq, a chemical genomic method for the transcriptome-wide quantitative mapping of ac 4 C at single-nucleotide resolution. In human and yeast mRNAs, ac 4 C sites are not detected but can be induced—at a conserved sequence motif—via the ectopic overexpression of eukaryotic acetyltransferase complexes. By contrast, cross-evolutionary profiling revealed unprecedented levels of ac 4 C across hundreds of residues in rRNA, tRNA, non-coding RNA and mRNA from hyperthermophilic archaea. Ac 4 C is markedly induced in response to increases in temperature, and acetyltransferase-deficient archaeal strains exhibit temperature-dependent growth defects. Visualization of wild-type and acetyltransferase-deficient archaeal ribosomes by cryo-electron microscopy provided structural insights into the temperature-dependent distribution of ac 4 C and its potential thermoadaptive role. Our studies quantitatively define the ac 4 C landscape, providing a technical and conceptual foundation for elucidating the role of this modification in biology and disease.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Landscape of Cross-Laminated Timber in the United States

Mass timber construction is an emerging sustainable construction practice in the United States given its renewable nature and its ability to store carbon during its use. Cross-laminated timber (CLT) is a type of mass timber construction that involves a wood panel system that is manufactured by gluing alternating lumber board layers at right angles. CLT panels have high strength, dimensional stability, and the ability to resist high compressive forces. They are considered a sustainable alternative to reinforced concrete construction because of the renewable nature of the primary wood material in CLT panels. Despite its environmental and structural benefits, the adoption rate of CLT remains low. This report investigates the current landscape of CLT use in buildings, providing information on the types of building that use CLT, how those buildings are used, and in what U.S. regions CLT is manufactured and used. This information helps identify potential barriers to adoption to inform ways to reduce these barriers. This review synthesizes insights from recent studies to offer a detailed perspective on the state of CLT adoption, its barriers, and the evolving landscape of opportunities that may facilitate its broader acceptance and use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of an Embedded Fracture and Borehole Modeling Approach to the Understanding of EGS Collab Experiment 1

EGS Collab is a series of meso-scale experiments and associated numerical simulation activities being funded by the United States Department of Energy, Geothermal Technologies Office (GTO) to investigate enhanced geothermal system processes under in-situ stress and slightly elevated temperature conditions. This project is designed to provide scientists and engineers with immediate access to impermeable rock at scales larger than possible in the laboratory, but generally smaller than those for commercial production. Immediate access to rock is provided via the existing drifts of the former Homestake Gold Mine, now operated as the Sanford Underground Research Facility in Lead, South Dakota. The objectives of the EGS Collab project are to develop well controlled fracture networks between injector and producer boreholes using normal and shear stimulation for permeability enhancement. The first experimental site was located off the West Access drift on the 4850 Level (4850 feet below ground surface) in phyllite of the Precambrian Poorman formation, and involved the creation of a fracture network comprising a combination of hydraulic and natural fractures. A second experimental site is now being considered near the battery alcove on the 4100 Level in amphibolite and rhyolite of the Yates Unit. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. Experiment 1 has comprised a series of successful tests, including a long-term chilled-water circulation test, but the testbed has two atypical EGS elements. Active ventilation in the adjacent drift over a 50-year period cooled the testbed rock mass and hydraulic fracturing intersected monitoring boreholes making them conduits for fluid flow. Numerical simulations executed in support of the design of the EGS Collab Experiment 1, computed a radial temperature distribution and stress gradient orthogonal to the drift axis, resulting in the forecast of an oblong hydraulic fracture geometry, extended in the direction of the drift from the stimulation borehole. This paper describes the numerical simulation of long-term chilled-water circulation test with an embedded fracture and borehole modeling approach. The principal objective of the simulation work is show agreement between experimental observations in terms of production fluid temperatures, monitoring borehole temperatures, injection and production pressures, and tracer recoveries using a single conceptual model for the fracture network, using characterization and monitoring data generally available for EGS. A secondary objective is to improve the numerical simulation result comparisons with additional data available from the broader monitoring equipment within the testbed versus deeper, hotter, and more remote EGS. One complicating factor for comparisons between the numerical simulation results and experimental observations, is the Joule-Thomson heating associated with large pressure drops across the fracture network.

numerical simulation, embedded fractures and boreh↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Modeling Approaches for Predicting Frost Growth and Defrosting on Tube-Fin Heat Exchangers: Preprint

Frost formation and growth on the evaporator surface is a common process that deteriorates the air-refrigerant heat transfer and restricts airflow. This degrades the performance of the vapor compression system by increasing temperature lift and air-side pressure drop. To accurately predict these effects during coil frosting, as well as the energy use and duration of the defrost process, there is a need to estimate the heat and mass transfer, momentum transport, and solid-liquid and liquid-vapor phase change. Therefore, in the past few decades, continuous effort has been made to model frosting and defrosting processes using approaches ranging from empirical correlations to computational fluid dynamic models. To provide a clearer overview for researchers, engineers, and manufacturers in this field, this paper provides a comprehensive literature review for frosting and defrosting models. The paper begins with theoretical background of frost formation and defrost processes, and then reviews the common modeling approaches in literature and their underlying assumptions when trying to account for various physical phenomenon. Based on the literature review, the most critical modeling effort for frost formation is the determination of frost densification rate and frost growth rate. Various methods to predict these two parameters are reviewed. Empirical correlations commonly used for frost density and thermal conductivity are presented and compared. For the defrost process, various multi-stage models have been proposed with different assumptions. Some assume the presence of air gap between the tube wall and the frost, while others consider the melted frost flow due to gravity. We also review physics-based and empirical approaches to integrate defrost models into heat pump models. We conclude by identifying research gaps and providing recommendations.

defrost↗

Analyzing BMP2, FGFR, and TGF Beta Expressions in High-Grade Osteosarcoma Untreated and Treated Autografts Using Proteomic Analysis

In the last few decades, biological reconstruction techniques have improved greatly for treating high-grade osteosarcoma patients. To conserve the limb, and its function the affected tumor-bearing bones have been treated using liquid nitrogen and irradiation processes that enable the removal of entire tumors from the bone, and these treated autografts can be reconstructed for the patients. Here, we focus on the expressions of the growth factor family proteins from the untreated and treated autografts that play a crucial role in bone union, remodeling, and regeneration. In this proteomic study, we identify several important cytoskeletal, transcriptional, and growth factor family proteins that showed substantially low levels in untreated autografts. Interestingly, these protein expressions were elevated after treating the tumor-bearing bones using liquid nitrogen and irradiation. Therefore, from our preliminary findings, we chose to determine the expressions of BMP2, TGF-Beta, and FGFR proteins by the target proteomics approach. Using a newly recruited validation set, we successfully validate the expressions of the selected proteins. Furthermore, the increased growth factor protein expression after treatment with liquid nitrogen may contribute to bone regeneration healing, assist in faster recovery, and reduce local recurrence and metastatic spread in high-grade sarcoma patients.

60 APPLIED LIFE SCIENCES↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuel-rich oxidation of gasoline surrogate components in an atmospheric flow reactor

Fuel-rich oxidation of three typical gasoline surrogate components, toluene, isooctane, and n-heptane, was investigated in an atmospheric-pressure flow reactor at mean gas temperatures from 1050 to 1350 K, equivalence ratio of 9.0, and residence times of 0.45 and 1.2 s. Not only polycyclic aromatic hydrocarbons (PAHs) up to 3 ring structure but also small intermediate products from C 1 to C 5 were quantified by a gas chromatograph mass spectrometry coupled with photon ionization and gas chromatograph with flame ionization detector, respectively. The kinetic model recently developed by Lawrence Livermore National Laboratory was revised to reflect the results of many recent investigations. Basically, the updated model could satisfactorily reproduce the experimental mole fractions of many species. The experimental and simulated results showed that PAH mole fractions produced were in the order of toluene, isooctane, and n-heptane. The kinetic analysis using the model was carried out to explore PAH formation pathways, especially focusing on naphthalene, acenaphthylene, and phenanthrene. Through rate of production analysis, it was found that the main formation pathways of many PAHs were affected by the fuels. Although resonantly stabilized radicals, such as benzyl and fulvenallenyl radicals, played a crucial role in the formation pathways of many PAHs in every fuel, they were produced through hydrogen elimination of toluene in toluene fuel, while they were formed from small intermediate products in isooctane and n-heptane fuels. Sensitivity analysis revealed the difference and similarity of the reactions with large positive coefficients according to the fuels studied here. In conclusion, the molecular growth reactions of aromatic species were influential in PAH production in every fuel, whereas the ring formation reactions from small species and the reactions involving toluene had large positive sensitivity coefficients in isooctane/n-heptane and toluene fuels, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Deposition to Encapsulation: Roll-to-roll manufacturing of organic light emitting devices for lighting (Final Report)

Organic light emitting devices (OLEDs) are promising solid state light sources due to their high efficiency, high color quality and flexible form factors. The key to enable low cost OLED lighting, is to rapidly fabricate thin film organic layers on a continuous flexible roll, called R2R processing. This project aims to investigate the feasibility of mass production of OLED lighting using the R2R process, from deposition to encapsulation. A high efficiency white OLED is fabricated on 10 cm-wide substrate rolls in a pilot R2R tool comprising of two different organic deposition: vacuum thermal evaporation (VTE) and organic vapor phase deposition (OVPD). A high quality encapsulation process to package OLEDs is demonstrated using an atomic layer deposition tool integrated to the R2R system without air exposure. The method to achieve ultrahigh deposition rates required by R2R processing is demonstrated by OVPD. Uniform organic semiconductor thin films grown by OVPD at rates as high as 50 Å/s are achieved. A comprehensive numerical model that is capable of simulating complex, multilayer WOLED structures is developed to provide an alternative to experimental iterations of OLED design and tests. A cost estimate on the R2R production of WOLEDs for lighting is developed. Assuming a WOLED luminance of 10 klm/m 2 , the cost of a WOLED light engine is anticipated to be $\$ 12.5$ /klm. With incremental reduction in material and driver costs and improved luminance, the cost of WOLED lighting can be reduced to $\$ 6.3$ /klm in the near term. These findings suggest OLED lighting can be volume manufactured by R2R vapor deposition methods with much reduced costs compared to current batch processing methods, potentially positioning WOLEDs for use in numerous premium lighting applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Scalable Method for Decarbonizing Modular Building Solutions: Preprint

The decarbonization movement emphasizes the shift in focus from energy efficiency to directly reducing global-warming impact. Blokable, LLC, a vertically integrated modular builder with an all-electric portfolio, worked with NREL on a roadmap to decarbonize its high-performance building product at a relative cost advantage by utilizing the learning curves of mass production. Previous decarbonization literature focused on either i) lifecycle assessments, or ii) efficiency measures. These decarbonization exercises were bespoke to individual building projects and did not consider positive feedback loops of builder experience or process repetition. Vertically integrated, prefab builders possess the unique ability to leverage learning and repetition to decarbonize their design-build-operate process. This collaboration between Blokable and NREL resulted in a decarbonization strategy utilizing the company's scaling and production efficiencies, on-site renewable energy and storage, and the projected evolution of building components over time based on trends and emerging legislation. The method developed here encompasses a growing business model, lifecycle carbon assessment, and projected changes in product and grid emissions over time due to existing trends and emerging legislation. This methodology incorporates learning-curve efficiencies gleaned from scaled manufacturing, as well as open-source tools integration for energy and carbon accounting. The output projects and compares cost and carbon savings per modular unit as production increases to 10,000 dwelling units annually over 15 years. The resulting roadmap illustrates a path to roughly 60% carbon savings and beyond-net-zero-energy performance at no incremental cost by 2030. The methodology can be mapped to other integrated or productized builders for methodical decarbonization.

affordable housing↗

A Scalable Method for Decarbonizing Modular Building Solutions

The decarbonization movement emphasizes the shift in focus from energy efficiency to directly reducing global-warming impact. Blokable, LLC, a vertically integrated modular builder with an all-electric portfolio, worked with NREL on a roadmap to decarbonize its high-performance building product at a relative cost advantage by utilizing the learning curves of mass production. Previous decarbonization literature focused on either i) lifecycle assessments, or ii) efficiency measures. These decarbonization exercises were bespoke to individual building projects and did not consider positive feedback loops of builder experience or process repetition. Vertically integrated, prefab builders possess the unique ability to leverage learning and repetition to decarbonize their design-build-operate process. This collaboration between Blokable and NREL resulted in a decarbonization strategy utilizing the company's scaling and production efficiencies, on-site renewable energy and storage, and the projected evolution of building components over time based on trends and emerging legislation. The method developed here encompasses a growing business model, lifecycle carbon assessment, and projected changes in product and grid emissions over time due to existing trends and emerging legislation. This methodology incorporates learning-curve efficiencies gleaned from scaled manufacturing, as well as open-source tools integration for energy and carbon accounting. The output projects and compares cost and carbon savings per modular unit as production increases to 10,000 dwelling units annually over 15 years. The resulting roadmap illustrates a path to roughly 60% carbon savings and beyond-net-zero-energy performance at no incremental cost by 2030. The methodology can be mapped to other integrated or productized builders for methodical decarbonization.

affordable housing↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theory Guided Fine‐Tune of Strain Effects in Pt Ternary Alloy via Rare Earth Templating: Achieving High Performance PEMFCs Catalysts

The sluggish kinetics and insufficient durability of platinum-based catalysts remain crucial barriers limiting proton-exchange-membrane fuel cells (PEMFCs) deployment. Here, we report a theory-guided synthesis combined with rare-earth templating to realize a previously inaccessible Pt 5 Co-like phase with tailored atomic-scale strain. Guided by density functional theory (DFT) calculations, we identified that a Pt 5 Co-like sublayer can induce a unique mild compressive strain (−1.24%) to the Pt(111) shell and an optimal *OH binding energy shift (ΔE ≈ 0.11 eV). This shift positions the alloy catalyst near the apex of the oxygen reduction reaction activity volcano. This prediction guided the synthesis of ternary alloy Pt 5 (Ce)Co@Pt multilayer nanoparticles, featuring a Ce-stabilized core, a Pt 5 Co-like sublayer, and a Pt-rich shell. This catalyst demonstrates both exceptionally high activity and durability, achieving a mass activity of 2.6 A∙mg Pt −1 in rotating disk electrode testing. In fuel cell membrane electrode assembly tests, Pt 5 (Ce)Co@Pt achieves a current density of 1.9 A∙cm −2 at 0.7 V under heavy-duty vehicle conditions. Remarkably, it maintains 1.2 A∙cm −2 after 1 80 000 AST cycles, doubling the U.S. DOE 2025 target. This work demonstrates a rational design strategy that DFT-guided strain engineering integrates with rare-earth templating to advance Pt-based catalysts for fuel cell applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗