Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

MAC/GMC Code Enhanced for Coupled Electromagnetothermoelastic Analysis of Smart Composites

Intelligent materials are those that exhibit coupling between their electromagnetic response and their thermomechanical response. This coupling allows smart materials to react mechanically (e.g., an induced displacement) to applied electrical or magnetic fields (for instance). These materials find many important applications in sensors, actuators, and transducers. Recently interest has arisen in the development of smart composites that are formed via the combination of two or more phases, one or more of which is a smart material. To design with and utilize smart composites, designers need theories that predict the coupled smart behavior of these materials from the electromagnetothermoelastic properties of the individual phases. The micromechanics model known as the generalized method of cells (GMC) has recently been extended to provide this important capability. This coupled electromagnetothermoelastic theory has recently been incorporated within NASA Glenn Research Center's Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC). This software package is user friendly and has many additional features that render it useful as a design and analysis tool for composite materials in general, and with its new capabilities, for smart composites as well.

Bednarcyk, Brett A.↗

Droplet microactuator system

The present invention relates to a droplet microactuator system. According to one embodiment, the droplet microactuator system includes: (a) a droplet microactuator configured to conduct droplet operations; (b) a magnetic field source arranged to immobilize magnetically responsive beads in a droplet during droplet operations; (c) a sensor configured in a sensing relationship with the droplet microactuator, such that the sensor is capable of sensing a signal from and/or a property of one or more droplets on the droplet microactuator; and (d) one or more processors electronically coupled to the droplet microactuator and programmed to control electrowetting-mediated droplet operations on the droplet actuator and process electronic signals from the sensor.

Pamula, Vamsee K.↗

Development of Cryogenic Filter Wheels for the HERSCHEL Photodetector Array Camera & Spectrometer (PACS)

This paper describes the two PACS Filter Wheels that are direct-drive rotational mechanisms operated at a temperature below 5K inside the PACS focal plane unit of the Herschel Satellite. The purpose of the mechanisms is to switch between filters. The rotation axis is pivoted to the support structure via a slightly preloaded pair of ball bearings and driven by a Cryotorquer. Position sensing is realized by a pair of Hall effect sensors. Powerless positioning at the filter positions is achieved by a magnetic ratchet system. The key technologies are the Cryotorquer design and the magnetic ratchet design in the low temperature range. Furthermore, we will report on lessons learned during the development and qualification of the mechanism and the paint.

Koerner, Christian↗

Apparatus and Method for Low-Temperature Training of Shape Memory Alloys

An apparatus and method for the low-temperature thermo-mechanical training of shape memory alloys (SMA) has been developed. The experimental SMA materials are being evaluated as prototypes for applicability in novel thermal management systems for future cryogenic applications. Alloys providing two-way actuation at cryogenic temperatures are the chief target. The mechanical training regimen was focused on the controlled movement of rectangular strips, with S-bend configurations, at temperatures as low as 30 K. The custom holding fixture included temperature sensors and a low heat-leak linear actuator with a magnetic coupling. The fixture was mounted to a Gifford-McMahon cryocooler providing up to 25 W of cooling power at 20 K and housed within a custom vacuum chamber. Operations included both training cycles and verification of shape memory movement. The system design and operation are discussed. Results of the training for select prototype alloys are presented.

Training↗

Magnetic field satellite /MAGSAT/ spacecraft vector magnetometer calibration

The low-flying MAGSAT spacecraft, launched October 30, 1979, included a Vector Magnetometer to accurately map the magnitude and direction of the magnetic field of the earth. Calibration of the magnetometer included arc-second precision determination of the relative orientations of the three sensor axes in a coordinate system defined by optical references. This determination began with laboratory measurements of the relative alignments of optical components mounted with the magnetometer. The actual calibration procedure then consisted basically of accurate and repeatable positioning of the Vector Magnetometer within a unique magnetic test facility which nulls the earth's magnetic field, then generates magnetic fields of various orientations and strengths. Analysis of the magnetometer sensor outputs together with the position and alignment data then gave the axes orientations. We used precision theodolites and methods related to surveying techniques to achieve the accurate positioning and optical component alignment measurements. The final calibration accuracy exceeded results previously achieved in the facility.

Hinkal, S. W.↗

Characterization of Soil and Rock Magnetic Properties along Multiple Hillslope Transects at Teller Road Site, Seward Peninsula, Alaska, 2018 and 2023

The magnetometer data was collected in multiple directions across the watershed hillslope at the NGEE Arctic Teller Road site at mile marker 27 (TL_MM27) on the Seward Peninsula, Alaska over multiple years in March 2018 and April 2023. The magnetic data were collected using a Geometrics Inc. G-858 gradiometer and G-857 base station in 2018 and the G-864 gradiometer and G857 base station in 2023. The data was collected (in all instances) by towing the gradiometer behind a snow machine around the watershed with the two sensors in a vertical profile with constant spacing during the continuous survey in that specific year. Magnetic total field measurements were collected by gradiometer and base station, and the data processing was performed in Geometrics MagMap2000 software. The processing steps were limited to removal of data spikes (despiking), reading dropouts, and correction/removal of bad GPS points. All offsets between sensors and GPS are stated within the data files and metadata, alongwith the processed and raw data. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).In this data submission there are two sets of raw magnetic data (.bin and .stn for 2018 and base for 2023; raw rover mag for 2023 is in .csv) inside two .zip files that identify the year the mag data was collected. The data are proprietary format to Geometrics and can be opened and processed with MagMap2000 which can be downloaded for free at Geometrics website. There are also two processed data files *.csv for each year and two metadata files *.csv.

54 ENVIRONMENTAL SCIENCES↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple degree-of-freedom force and moment measurement for static propulsion testing using magnetic suspension technology

Innovative Information Systems (IIS), Inc. is in the process of designing and fabricating a high bandwidth force and moment measuring device (i.e. the Magnetic Thruster Test Stand). This device will use active magnetic suspension to allow direct measurements of the forces and torques generated by the rocket engines of the missile under test. The principle of operation of the Magnetic Thruster Test Stand (MTTS) is based on the ability to perform very precise, high bandwidth force and position measurements on an object suspended in a magnetic field. This ability exists due to the fact that the digital servo control mechanism that performs the magnetic suspension uses high bandwidth (10 kHz) position data (via an eddy-current proximity sensor) to determine the amount of force required to maintain stable suspension at a particular point. This force is converted into required electromagnet coil current, which is then output to a current amplifier driving the coils. A discussion of how the coil current and magnetic gap distance (the distance between the electromagnet and the object being suspended) is used to determine the forces being applied from the suspended assembly is presented.

Stuart, Keith↗

Signatures of fractional quantum anomalous Hall states in twisted MoTe 2

The interplay between spontaneous symmetry breaking and topology can result in exotic quantum states of matter. A celebrated example is the quantum anomalous Hall (QAH) state, which exhibits an integer quantum Hall effect at zero magnetic field owing to intrinsic ferromagnetism. In the presence of strong electron–electron interactions, fractional QAH (FQAH) states at zero magnetic field can emerge. These states could host fractional excitations, including non-Abelian anyons—crucial building blocks for topological quantum computation9. Here we report experimental signatures of FQAH states in a twisted molybdenum ditelluride (MoTe 2 ) bilayer. Magnetic circular dichroism measurements reveal robust ferromagnetic states at fractionally hole-filled moiré minibands. Using trion photoluminescence as a sensor, we obtain a Landau fan diagram showing linear shifts in carrier densities corresponding to filling factor v = −2/3 and v = −3/5 ferromagnetic states with applied magnetic field. These shifts match the Streda formula dispersion of FQAH states with fractionally quantized Hall conductance of ${\sigma }_{xy}=-\,\frac{2}{3}\frac{{e}^{2}}{h}$ and ${\sigma }_{xy}=-\,\frac{3}{5}\frac{{e}^{2}}{h}$ , respectively. Moreover, the v = −1 state exhibits a dispersion corresponding to Chern number −1, consistent with the predicted QAH state. In comparison, several non-ferromagnetic states on the electron-doping side do not disperse, that is, they are trivial correlated insulators. The observed topological states can be electrically driven into topologically trivial states. Our findings provide evidence of the long-sought FQAH states, demonstrating MoTe 2 moiré superlattices as a platform for exploring fractional excitations.

Quantum Hall↗

An Overview of Scientific and Space Weather Results from the Communication/Navigation Outage Forecasting System (C/NOFS) Mission

The Communication/Navigation Outage Forecasting System (C/NOFS) Mission of the Air Force Research Laboratory is described. C/NOFS science objectives may be organized into three categories: (1) to understand physical processes active in the background ionosphere and thermosphere in which plasma instabilities grow; (2) to identify mechanisms that trigger or quench the plasma irregularities responsible for signal degradation; and (3) to determine how the plasma irregularities affect the propagation of electromagnetic waves. The satellite was launched in April, 2008 into a low inclination (13 deg), elliptical (400 x 850 km) orbit. The satellite sensors measure the following parameters in situ: ambient and fluctuating electron densities, AC and DC electric and magnetic fields, ion drifts and large scale ion composition, ion and electron temperatures, and neutral winds. C/NOFS is also equipped with a GPS occultation receiver and a radio beacon. In addition to the satellite sensors, complementary ground-based measurements, theory, and advanced modeling techniques are also important parts of the mission. We report scientific and space weather highlights of the mission after nearly four years in orbit

Pfaff, R.↗

The magnetic field of Saturn - Pioneer 11 observations

The Pioneer 11 high-field fluxgate magnetometer experiment consists of two biaxial fluxgate sensors assemblies and an associated electronics system that is designed to measure fields up to 10 gauss along three orthogonal axes. It was used to provide a higher upper range than that provided by the helium vector magnetometer whose maximum measureable field is only 1.4 gauss. Observations of the intrinsic magnetic field of Saturn measured by the high-field fluxgate magnetometer were found to be much weaker than expected. An analysis of preliminary data combined with the preliminary trajectory yield a model for the main planetary field which is a simple centered dipole. It was determined that the polarity of Saturn is opposite that of Earth, and that the tilt is small, within 2 deg plus or minus 1 deg.

Acuna, M. H.↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Linear magnetic bearings

A self regulating, nonfrictional, active magnetic bearing is disclosed which has an elongated cylindrical housing for containing a shaft type armature with quadrature positioned shaft position sensors and equidistantly positioned electromagnets located at one end of the housing. Each set of sensors is responsive to orthogonal displacement of the armature and is used to generate control signals to energize the electromagnets to center the armature. A bumper magnet assembly is located at one end of the housing for dampening any undesired axial movement of the armature or to axially move the armature either continuously or fixedly.

Goldowskiy, M. P.↗

Magneto-inductive skin sensor for robot collision avoidance: A new development

Safety is a primary concern for robots operating in space. The tri-mode sensor addresses that concern by employing a collision avoidance/management skin around the robot arms. This rf-based skin sensor is at present a dual mode (proximity and tactile). The third mode, pyroelectric, will complement the other two. The proximity mode permits the robot to sense an intruding object, to range the object, and to detect the edges of the object. The tactile mode permits the robot to sense when it has contacted an object, where on the arm it has made contact, and provides a three-dimensional image of the shape of the contact impression. The pyroelectric mode will be added to permit the robot arm to detect the proximity of a hot object and to add sensing redundancy to the two other modes. The rf-modes of the sensing skin are presented. These modes employ a highly efficient magnetic material (amorphous metal) in a sensing technique. This results in a flexible sensor array which uses a primarily inductive configuration to permit both capacitive and magnetoinductive sensing of object; thus optimizing performance in both proximity and tactile modes with the same sensing skin. The fundamental operating principles, design particulars, and theoretical models are provided to aid in the description and understanding of this sensor. Test results are also given.

Chauhan, D. S.↗

Summary of Activities for Health Monitoring of Composite Overwrapped Pressure Vessels

This three-year project (FY12-14) will design and demonstrate the ability of new Magnetic Stress Gages for the measurement of stresses on the inner diameter of a Composite Overwrapped Pressure Vessel overwrap. The sensors are being tested at White Sands Testing Facility (WSTF) where the results will be correlated with a known nondestructive technique acoustic emission. The gages will be produced utilizing Meandering Winding Magnetometer (MWM) and/or MWM array eddy current technology. The ultimate goal is to utilize this technology for the health monitoring of Composite Overwrapped Pressure Vessels for all future flight programs. The first full-scale pressurization test was performed at WSTF in June 2012. The goals of this test were to determine adaptations of the magnetic stress gauge instrumentation that would be necessary to allow multiple sensors to monitor the vessel's condition simultaneously and to determine how the sensor response changes with sensor selection and orientation. The second full scale pressurization test was performed at WSTF in August 2012. The goals of this test were to monitor the vessel's condition with multiple sensors simultaneously, to determine the viability of the multiplexing units (MUX) for the application, and to determine if the sensor responses in different orientations are repeatable. For both sets of tests the vessel was pressured up to 6,000 psi to simulate maximum operating pressure. Acoustic events were observed during the first pressurization cycle. This suggested that the extended storage period prior to use of this bottle led to a relaxation of the residual stresses imparted during auto-frettage. The pressurization tests successfully demonstrated the use of multiplexers with multiple MWM arrays to monitor a vessel. It was discovered that depending upon the sensor orientation, the frequencies, and the sense element, the MWM arrays can provide a variety of complementary information about the composite overwrapped pressure vessel load conditions. For example, low frequency measurements can be used to monitor the overwrap thickness and changes associated with pressure level. High frequency data is dominated by the properties of the overwrap, including the fiber orientations and lay-up of the layers.

Russell, Rick↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗