Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

An Automatic Processing Framework for In Situ Determination of Ecohydrological Root Water Content by Ground-Penetrating Radar

This report concerns Root water content (RWC) as a vital component in water flux in soil-plant-atmosphere continuum. Knowledge of RWC helps to better understand the root function and the soil-root interaction and improves water cycle modeling. However, due to the lack of appropriate methods, field monitoring of RWC is seriously constrained. In this study, we used ground-penetrating radar (GPR), a common geophysical technique, to characterize RWC of coarse roots noninvasively. An automatic GPR data processing framework was proposed to (1) identify hyperbolic root reflections and locate roots in GPR images and (2) extract waveform parameters from the reflected wave of identified roots. These waveform parameters were then used to establish an empirical model and a semiempirical model to determine RWC. We validated the developed models using GPR root data at three antenna center frequencies (500 MHz, 900 MHz, and 2 GHz) that were produced from simulation experiments (with RWC ranging from 70% to 150%) and field experiments in sandy soils (with RWC ranging from 66% to 144%). Our results show that both the empirical and the semiempirical models achieved a good performance in estimating RWC with similar accuracy, i.e., the prediction error [root-mean-square error (RMSE)] was less than 8% for the simulation data and 12% for the field data. For both models, the accuracy of RWC estimation was the highest when applied to 2-GHz data. This study renders a new opportunity to determine RWC under field conditions that enhances the application of GPR for root study and the understanding and modeling of ecohydrology in the rhizosphere.

54 ENVIRONMENTAL SCIENCES↗

Ku band low noise parametric amplifier

A low noise, K sub u-band, parametric amplifier (paramp) was developed. The unit is a spacecraft-qualifiable, prototype, parametric amplifier for eventual application in the shuttle orbiter. The amplifier was required to have a noise temperature of less than 150 K. A noise temperature of less than 120 K at a gain level of 17 db was achieved. A 3-db bandwidth in excess of 350 MHz was attained, while deviation from phase linearity of about + or - 1 degree over 50 MHz was achieved. The paramp operates within specification over an ambient temperature range of -5 C to +50 C. The performance requirements and the operation of the K sub u-band parametric amplifier system are described. The final test results are also given.

Source record↗

Advanced digital SAR processing study

A highly programmable, land based, real time synthetic aperture radar (SAR) processor requiring a processed pixel rate of 2.75 MHz or more in a four look system was designed. Variations in range and azimuth compression, number of looks, range swath, range migration and SR mode were specified. Alternative range and azimuth processing algorithms were examined in conjunction with projected integrated circuit, digital architecture, and software technologies. The advaced digital SAR processor (ADSP) employs an FFT convolver algorithm for both range and azimuth processing in a parallel architecture configuration. Algorithm performace comparisons, design system design, implementation tradeoffs and the results of a supporting survey of integrated circuit and digital architecture technologies are reported. Cost tradeoffs and projections with alternate implementation plans are presented.

Martinson, L. W.↗

Meterwave observations of a coronal hole

Meter-wave maps are presented showing a coronal hole at 30.9, 50.0, and 73.8 MHz using the Clark Lake Radioheliograph in October 1984. The coronal hole seen against the disk at all three frequencies shows interesting similarities to, and significant differences from its optical signatures in HeI lambda10830 spectroheliograms. The 73.8 MHz coronal hole, when seen near disk center, appears to coincide with the HeI footprint of the hole. At the lower frequencies, the emission comes from higher levels of the corona, and the hole appears to be displaced, probably due to the non-radial structure of the coronal hole. The contrast of the hole relative to the quiet Sun is much greater than reported previously for a coronal hole observed at 80 MHz. The higher contrast is certainly real, due to the superior dynamic range, sensitivity, and calibration of the Clark Lake instrument. Using a coronal hole model, the electron density is derived from radio observations of the brightness temperature. A very large discrepancy is found between the derived density and that determined from Skylab EUV observations of coronal holes. This discrepancy suggests that much of the physics of coronal holes has yet to be elucidated.

Wang, Z.↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytical framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19-month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). From this framework it is inferred that the underlying source distribution is likely inverse exponential in amplitude, with a log-slope of 126-147 mW(sup -1/2). The underlying vertical distribution of VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose first moment increases as range squared. Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic solution estimates, suggesting that timing errors arising from poor signal identification and discrimination may dominate over timing errors arising from nominal sensor resolution. The VHF source properties of individual LDAR-observed flashes are computed and an analytic expression for flash detection efficiency vs. range is derived. This reveals nearly constant flash detection efficiency to 80-94 km range from the network centroid.

Boccippio, D. J.↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytic framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19 month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological impulsive VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). The underlying vertical distribution of impulsive VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within a 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose standard deviation increases as r(exp 2). Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic estimates. LDAR bulk flash detection efficiency is predicted to be above 90% to 94-113 km range from the network centroid and to fall below 10% at ranges greater than 200-240 km.

Boccippio, D. J.↗

IMAGE-EUV Observation of Large Scale Standing Wave Pattern in the Nightside Plasmasphere

We present analyses of a nightside plasmaspheric pattern of bifurcated, filamentary He(+) 30.4-nm emission enhancements observed by IMAGE EUV between approximately 19:40-22:13 UT on 28 June 2000 that indicate the presence of a large-scale, global ULF standing wave pattern. Analysis of coincident IMAGE magnetometer chain data reveals that these ULF waves extend across the magnetic latitude-longitude range of the chain and possess multiple spectral features between 0.6-5-mHz (3-30 minute period). Additionally, analysis of ACE SWE data reveals similarly structured spectral components in the solar wind. Collectively, these analyses lead to the conclusion that the observed large-scale ULF wave pattern is the result of solar wind pressure pulses 'ringing' the inner-magnetosphere.

Six, N. Frank↗

Drag-Free Performance of the ST7 Disturbance Reduction System Flight Experiment on the LISA Pathfinder

The Space Technology-7 Disturbance Reduction System (DRS) is an experiment package aboard the European Space Agency (ESA) LISA Pathfinder spacecraft. LISA Pathfinder launched from Kourou, French Guiana on December 3, 2015. The DRS is tasked to validate two specific technologies: colloidal micro-Newton thrusters (CMNT) to provide low-noise control capability of the spacecraft, and drag-free controlflight. This validation is performed using highly sensitive drag-free sensors, which are provided by the LISA Technology Package of the European Space Agency. The Disturbance Reduction System is required to maintain the spacecrafts position with respect to a free-floating test mass to better than 10nm/(square root of Hz), along its sensitive axis (axis in optical metrology). It also has a goal of limiting the residual accelerations of any of the two test masses to below 30 x 10(exp -14) (1 + ([f/3 mHz](exp 2))) m/sq s/(square root of Hz), over the frequency range of 1 to 30 mHz.This paper briefly describes the design and the expected on-orbit performance of the control system for the two modes wherein the drag-free performance requirements are verified. The on-orbit performance of these modes are then compared to the requirements, as well as to the expected performance, and discussed.

Attitude Control↗

Review of measurements of the RF spectrum of radiation from lightning

A review is presented of the measurements reported in the literature of the spectrum of electromagnetic radiation from lightning in the frequency range from 1 kHz to 1 GHz. Measurements have been made either by monitoring the power received at individual frequencies using a narrow bandwidth recording device or by recording the transient (time dependent) radiation with a wide bandwidth device and then Fourier transforming the waveform to obtain a spectrum. Measurements of the first type were made extensively in the 1950's and 1960's and several composite spectra have been deduced by normalizing the data of different investigators to common units of bandwidth and distance. The composite spectra tend to peak near 5 kHz and then decrease roughly as 1/(frequency) up to nearly 100 MHz where scatter in the data make the behaviour uncertain. The spectrum obtained with measurements of the second type is similar. Recent experiments have extended the frequency range covered to several 10's of MHz and include spectra for return strokes, the stepped leader and for some intracloud processes. The spectrum of first return strokes obtained in this manner is very similar to the spectrum of the composite flash obtained from the narrowband measurements.

Radiation↗

Discovery of a 7 mHz X-Ray Quasi-Periodic Oscillation from the Most Massive Stellar-Mass Black Hole IC 10 X-1

We report the discovery with XMM-Newton of an approx.. = 7 mHz X-ray (0.3-10.0 keV) quasi-periodic oscillation (QPO) from the eclipsing, high-inclination black hole binary IC 10 X-1. The QPO is significant at >4.33 sigma confidence level and has a fractional amplitude (% rms) and a quality factor, Q is identical with nu/delta nu, of approx. = 11 and 4, respectively. The overall X-ray (0.3-10.0 keV) power spectrum in the frequency range 0.0001-0.1 Hz can be described by a power-law with an index of approx. = −2, and a QPO at 7 mHz. At frequencies approx. > 0.02 Hz there is no evidence for significant variability. The fractional amplitude (rms) of the QPO is roughly energy-independent in the energy range of 0.3-1.5 keV. Above 1.5 keV the low signal-to-noise ratio of the data does not allow us to detect the QPO. By directly comparing these properties with the wide range of QPOs currently known from accreting black hole and neutron stars, we suggest that the 7 mHz QPO of IC 10 X-1 may be linked to one of the following three categories of QPOs: (1) the "heartbeat" mHz QPOs of the black hole sources GRS 1915+105 and IGR J17091−3624, or (2) the 0.6-2.4 Hz "dipper QPOs" of high-inclination neutron star systems, or (3) the mHz QPOs of Cygnus X-3.

Oscillation↗

Automatic gain control

An automatic gain control (AGC), designed to operate with the prototype Loran-C receiver, is described. The device is used to eliminate error which occurs when signals are received at different magnitudes. The automatic gain control is a three transistor circuit which requires a constant dc voltage of 8 volts. Tests conclude that this value may be in the range of 4 to 12 v without change in circuit performance. Two transistors are cascaded to pass and amplify the input signal. Their gain is controlled by a third transistor which itself is controlled by an external AGC voltage between 0 and 8 volts dc. The integrated circuit used is an 8 pin chip, which is a differential cascade amplifier designed for use in communications operating at frequencies from dc to 120 MHz. The integrated circuit was balanced for AGC capabilities, and has a wide operating current range. The maximum input current at pins 1 and 5 is 0.1 mAmps. AGC testing is described.

Roman, J. P.↗

800 °C Demonstrated kHz SiC IC Electronics and Pressure Sensors as Technical Foundation for Realizing MHz DARPA HOTS Goals

The HOTS program will develop a technology for high-bandwidth, high-dynamic-range sensing at high temperature. Performance will be validated through the development and demonstration of a pressure sensor module (i.e., integrated transducer and signal-conditioning microelectronics) achieving the following performance goals: NASA Glenn has unique technology experience in extreme environment pressure sensors & IC electronics, including at 800 °C in air, providing significant risk reduction in meeting DARPA HOTS goals. Appropriate partnership and tech transfer should accelerate realization of DARPA HOTS hard technical challenges.

SiC pressure sensor electronics high temperature↗

A Fast Mechanical Tuner for SRF Cavities

There is a particular need for fast tuners and phase shifters for advanced superconducting accelerator RF systems. The tuners based on ferrite, ferroelectric and piezo materials are commonly used. However, those methods suffer from one or another issue of high power loss, slow response, and narrow tuning range. We propose a robust, fast (up to ~5 MHz/sec), high efficient mechanical tuner for SRF cavities operating at the frequency 50 MHz. We develop an external mechanical tuner that is strongly coupled to the cavity. The tuner design represents a trade-off of high efficiency (low RF losses and low heat flux) and frequency tunability range. Our approach solves this trade-off issue. We propose RF design which exploits two coupled resonators so that a main high-field cavity is controlled with a small tunable resonator with a flexible metallic wall operating in a relatively low RF field. Simulations, carried out for a 7.5 MV/m 50 MHz SRF Quarter Wave Resonator (QWR), show that frequency tunability at level 10⁻³ is obtainable.

43 PARTICLE ACCELERATORS↗

A Highly Sensitive Multi-Element HgCdTe E-APD Detector for IPDA Lidar Applications

An HgCdTe electron avalanche photodiode (e-APD) detector has been developed for lidar receivers, one application of which is integrated path differential absorption lidar measurements of such atmospheric trace gases as CO2 and CH4. The HgCdTe APD has a wide, visible to mid-wave-infrared, spectral response, high dynamic range, substantially improved sensitivity, and an expected improvement in operational lifetime. A demonstration sensor-chip assembly consisting of a 4.3 lm cutoff HgCdTe 4 9 4 APD detector array with 80 micrometer pitch pixels and a custom complementary metal-oxide-semiconductor readout integrated circuit was developed. For one typical array the APD gain was 654 at 12 V with corresponding gain normalized dark currents ranging from 1.2 fA to 3.2 fA. The 4 9 4 detector system was characterized at 77 K with a 1.55 micrometer wavelength, 1 microsecond wide, laser pulse. The measured unit gain detector photon conversion efficiency was 91.1%. At 11 V bias the mean measured APD gain at 77 K was 307.8 with sigma/mean uniformity of 1.23%. The average, noise-bandwidth normalized, system noise-equivalent power (NEP) was 1.04 fW/Hz(exp 1/2) with a sigma/mean of 3.8%. The measured, electronics-limited, bandwidth of 6.8 MHz was more than adequate for 1 microsecond pulse detection. The system had an NEP (3 MHz) of 0.4 fW/Hz(exp 1/2) at 12 V APD bias and a linear dynamic range close to 1000. A gain-independent quantum-limited SNR of 80% of full theoretical was indicative of a gain-independent excess noise factor very close to 1.0 and the expected APD mode quantum efficiency.

NEP↗

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Propagation predictions and studies using a ray tracing program combined with a theoretical ionospheric model

Radio wave propagation predictions are described in which modern comprehensive theoretical ionospheric models are coupled with ray-tracing programs. In the computer code described, a network of electron density and collision frequency parameters along a band about the great circle path is calculated by specifying the transmitter and receiver geographic coordinates, time, the day number, and the 2800-MHz solar flux. The ray paths are calculated on specifying the frequency, mode, range of elevation angles, and range of azimuth angles from the great circle direction. The current program uses a combination of the Penn State MKI E and F region models and the Mitra-Rowe D and E region model. Application of the technique to the prediction of satellite to ground propagation and calculation of oblique incidence propagation paths and absorption are described. The implications of the study to the development of the next generation of ionospheric models are discussed.

Lee, M. K.↗

Wideband heterodyne receiver for laser communication system

A heterodyne receiver for laser communication is described which includes a front end having a cooled photomixer contained in a hermetically sealed spaced quality housing designed for wide bandwidth transmission. The photomixer is coupled through a wideband preamplifier to the receiver back end which includes a frequency tracking network and demodulating equipment. The receiver is capable of tracking a Doppler frequency shift of 750 MHz, positive or negative, and has an instantaneous intermediate frequency information bandwidth of 400 MHz. The receiver system is also capable of operating over a wide temperature range and is designed to be suitable for use in outer space communication.

Flattau, T.↗

Wideband EMG telemetry system

Miniature, individual crystal-controlled RF transmitters located in EMG pressure sensors simplifies multichannel EMG telemetry for electronic gait monitoring. Transmitters which are assigned operating frequencies within 174 - 216 MHz band have linear frequency response from 20 - 2000 Hz and operate over range of 15 m.

Rosatino, S. A.↗