Vapor and Liquid ( p –ρ– T–x ) Measurements of Binary Refrigerant Blends Containing R-32, R-152a, R-227ea, R-1234yf, and R-1234ze(E)

In this article, The pressure–density–temperature–composition (p–ρ–T–x) data of binary refrigerant mixtures containing R-32 (difluoromethane), R-152a (1,1,-difluoroethane), R-227ea (1,1,1,2,3,3,3-heptafluoropropane), R-1234yf (2,3,3,3-tetrafluoropropene), and R-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) were measured in both the vapor and liquid phases using a two-sinker, magnetic suspension densimeter. The specific samples in this study comprised two compositions of approximately (0.3/0.7) and (0.7/0.3) mole fraction for each of the following four binary refrigerant blends: R-32 + R-1234yf, R-32 + R-1234ze(E), R-1234yf + R-152a, and R-1234ze(E) + R-227ea. Single-phase vapor densities were measured over a temperature range of approximately 253 to 293 K and pressures from 0.05 to 0.98 MPa. Single-phase liquid and supercritical densities were measured over a temperature range of approximately 230 to 400 K and pressures up to 22 MPa; for refrigerant blends containing R-1234yf, the maximum pressure was limited to 14 MPa. Overall relative combined, expanded (k = 2) uncertainties in density ranged from 0.025 to 0.191%, with an average uncertainty of approximately 0.05%. Here, we present measurement results, along with comparisons to available literature data and to default equations of state and mixture models included in REFPROP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing measurements of limiting current of electrolytes with theoretical predictions up to the solubility limit

Imposing a steady ionic current through an electrolyte results in the formation of salt concentration gradients that compromise battery performance. The limiting current is usually defined as the current at which the salt concentration at the cathode approaches zero. Higher currents cannot be imposed on the cell as larger concentration gradients are unsustainable. We study the limiting current in electrolytes comprising a perfluorinated oligomer, C8-DMC, and lithium bis-(fluorosulfonyl)imide salt in symmetric lithium cells. The time-dependence of the potential, which increases as salt concentration gradients develop, was also measured. Both steady-state and transient behaviors are modeled using Newman's concentrated solution theory; transport and thermodynamic parameters needed to perform the calculations were measured independently. The limiting current is a nonmonotonic function of salt concentration in both theory and experiment. The model shows that at low salt concentrations (below 0.88 mol/kg solvent), the concentration at the cathode approaches zero at limiting current. In contrast, at high salt concentrations (above 0.88 mol/kg solvent), the concentration at the anode approaches the solubility limit (2.03 mol/kg solvent). The experimentally determined salt concentration at which the limiting current is maximized is in excellent agreement with theoretical predictions made without resorting to any adjustable parameters.

Shah, Deep B.↗

Broad Applicability of Electrochemical Impedance Spectroscopy to the Measurement of Oxygen Nonstoichiometry in Mixed Ion and Electron Conductors

Oxygen non-stoichiometry is a fundamental feature of mixed ion and electron conductors (MIECs). In this work a general electrochemical method for determining non-stoichiometry in thin film MIECs, via measurement of the chemical capacitance, is demonstrated using ceria and ceria-zirconia (Ce 0.8 Zr 0.2 O 2-δ ) as representative materials. A.C. impedance data are collected from both materials at high temperature (750-900 °C) under reducing conditions with oxygen partial pressure (pO 2 ) in the range 10-13 to 10-20 atm. Additional measurements of ceria-zirconia films are made under relatively oxidizing conditions with pO 2 in the range 0.2 to 10 -4 atm and temperatures of 800-900 °C. Under reducing conditions, the impedance spectra are described by a simple circuit in which a resistor is in series with a resistor and capacitor in parallel, and thickness dependent measurements are used to resolve the capacitance into interfacial and chemical terms. Under more oxidizing conditions, the impedance spectra (of Ce 0.8 Zr 0.2 O 2-δ ) reveal an additional diffusional feature, which enables determination of the ionic resistance of the film in addition to the capacitance, and hence the transport properties. A generalized mathematical formalism is presented for recovering the non-stoichiometry from the chemical capacitance, without recourse to defect chemical models. The ceria non-stoichiometry values are in good agreement with literature values determined by thermogravimetric measurements but display considerably less scatter and are collected on considerably shorter timescales. Here, the thermodynamic analysis of Ce 0.8 Zr 0.2 O 2-δ corroborates earlier findings that introduction of Zr into ceria enhances its reducibility.

08 HYDROGEN↗

Thermodynamic properties of autunite, uranyl hydrogen phosphate, and uranyl orthophosphate from solubility and calorimetric measurements

In this study, we use solubility and oxide melt solution calorimetry measurements to determine the thermodynamic properties of the uranyl phosphate phases autunite (abbreviated: CaUP), uranyl hydrogen phosphate (HUP), and uranyl orthophosphate (UP). Solubility measurements from both supersaturated and undersaturated conditions, as well as under different pH conditions, rigorously demonstrate attainment of equilibrium and yield well-constrained solubility product values of -48.36 (-0.03 /+ 0.03), -13.17 (-0.11 / +0.07), and -49.36 (-0.04 / +0.02) for CaUP, HUP, and UP, respectively. We use the solubility data to calculate standard state Gibbs free energies of formation for all phases (-7630.61 ± 9.69, -3072.27 ± 4.76, and -6138.95 ± 12.24 kJ mol-1 for CaUP, HUP, and UP, respectively), and calorimetry data to calculate standard state enthalpies of formation of -3223.22 ± 4.00 and -7001.01 ± 15.10 kJ mol-1 for HUP and UP, respectively. Combining these results allows us also to calculate the standard state entropies of formation of -506.54 ± 10.48 and -2893.12 ± 19.44 kJ mol-1 K-1 for HUP and UP phases, respectively. The results from this study are part of a combined effort to develop reliable and internally consistent thermodynamic data for environmentally relevant uranyl minerals. Data such as these are required in order to optimize and quantitatively assess the effect of phosphate amendment remediation technologies for uranium contaminated systems.

54 ENVIRONMENTAL SCIENCES↗

Rate constants for OH with selected large alkanes : shock-tube measurements and an improved group scheme.

High-temperature rate constant experiments on OH with the five large (C{sub 5}-C{sub 8}) saturated hydrocarbons n-heptane, 2,2,3,3-tetramethylbutane (2,2,3,3-TMB), n-pentane, n-hexane, and 2,3-dimethylbutane (2,3-DMB) were performed with the reflected-shock-tube technique using multipass absorption spectrometric detection of OH radicals at 308 nm. Single-point determinations at {approx}1200 K on n-heptane, 2,2,3,3-TMB, n-hexane, and 2,3-DMB were previously reported by Cohen and co-workers; however, the present work substantially extends the database to both lower and higher temperature. The present experiments span a wide temperature range, 789-1308 K, and represent the first direct measurements of rate constants at T > 800 K for n-pentane. The present work utilized 48 optical passes corresponding to a total path length of {approx}4.2 m. As a result of this increased path length, the high OH concentration detection sensitivity permitted pseudo-first-order analyses for unambiguously measuring rate constants. The experimental results can be expressed in Arrhenius form in units of cm{sup 3} molecule{sup -1} s{sup -1} as follows: K{sub OH+n-heptane} = (2.48 {+-} 0.17) x 10{sup -10} exp[(-1927 {+-} 69 K)/T] (838-1287 K); k{sub OH+2,2,3,3-TMB} = (8.26 {+-} 0.89) x 10{sup -11} exp[(-1337 {+-} 94 K)/T] (789-1061 K); K{sub OH+n-pentane} = (1.60 {+-} 0.25) x 10{sup -10} exp[(-1903 {+-} 146 K)/T] (823-1308 K); K{sub OH+n-hexane} = (2.79 {+-} 0.39) x 10{sup -10} exp[(-2301 {+-} 134 K)/T] (798-1299 K); and k{sub OH+2,3-DMB} = (1.27 {+-} 0.16) x 10{sup -10} exp[(-1617 {+-} 118 K)/T] (843-1292 K). The available experimental data, along with lower-T determinations, were used to obtain evaluations of the experimental rate constants over the temperature range from {approx}230 to 1300 K for most of the title reactions. These extended-temperature-range evaluations, given as three-parameter fits, are as follows: k{sub OH+n-heptane} = 2.059 x 10{sup -5}T{sup 1.401} exp(33 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (241-1287 K); k{sub OH+2,2,3,3-TMB} = 6.835 x 10{sup -17}T{sup 1.886} exp(-365 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (290-1180 K); k{sub OH+n-pentane} = 2.495 x 10{sup -16}T{sup 1.649} exp(80 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (224-1308 K); k{sub OH+n-hexane} = 3.959 x 10{sup -18}T{sup 2.218} exp(443 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (292-1299 K); and k{sub OH+2,3-DMB} = 2.287 x 10{sup -17}T{sup 1.958} exp(365 K/T) cm{sup 3} molecule{sup -1} s{sup -1} (220-1292 K). The experimental data and the evaluations obtained for these five larger alkanes in the present work were used along with prior data/evaluations obtained in this laboratory for H abstractions by OH from a series of smaller alkanes (C{sub 3}?C{sub 5}) to devise rate rules for abstractions from various types of primary, secondary, and tertiary H atoms. Specifically, the current scheme was applied with good success to H abstractions by OH from a series of n-alkanes (n-octane through n-hexadecane). The total rate constants using this group scheme for reactions of OH with selected large alkanes are given as three-parameter fits in this article. The rate constants for the various abstraction channels in any large n-alkane can also be obtained using the groups listed in this article. The present group scheme serves to reduce the uncertainties in rate constants for OH + alkane reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New measurements of the EMC Effect in Light Nuclei and at Large x

While the modification of structure functions in nuclei (the EMC Effect) has been the focus of intense experimental and theoretical study since the original discovery in 1983, the experimental emphasis has been on heavy or mediumheavy nuclei. The theoretical interpretation of the EMC Effect is far from clear; it remains difficult to disentangle the "conventional" nuclear physics effects of binding and Fermi motion from more exotic effects. The study of the EMC Effect in light nuclei, where the detailed nuclear structure is well understood, and at large x, where effects from Fermi motion dominate, will add new insight into the underlying mechanism at work. Experiment E03103 at Jefferson Lab measured electron scattering cross sections from nuclei (A=3 to 197) and the deuteron to provide new data on the EMC Effect. These measurements will greatly improve the precision of the existing data set on 4He, provide the first measurement of the EMC Effect in 3He for x>0.5, a

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Precision Measurement Of The Neutral Pion Lifetime: The PRIMEX Experiment

The PRIMEX collaboration at Jefferson Lab is completing an experimental analysis to obtain a precision measurement of the neutral pion lifetime. Results from the experiment will be presented and comparisons made with the chiral anomaly prediction and NLO calculations. An extension of the experiment to 12 GeV for measurements of the {eta} and {eta}' radiative widths is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton Form Factor Measurements Using Polarization Method: Beyond Born Approximation

Significant theoretical and experimental efforts have been made over the past 7 years aiming to explain the discrepancy between the proton form factor ratio data obtained at JLab using the polarization method and the previous Rosenbluth measurements. Preliminary results from the first high precision polarization experiment dedicated to study effects beyond Born approximation will be presented. The ratio of the transferred polarization components and, separately, the longitudinal polarization in ep elastic scattering have been measured at a fixed Q{sup 2} of 2.5 GeV{sup 2} over a wide kinematic range. The two quantities impose constraints on the real part of the ep elastic amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-Spin Asymmetry Measurement at CLAS

Beam Single Spin Asymmetries in single neutral semi-inclusive pion electroproduction off an unpolarized hydrogen target in the deep inelastic scattering regime (Q{sup 2}>1 GeV{sup 2}, W{sup 2}>4 GeV{sup 2}) have been measured using a polarized electron beam of 5.776 GeV with the CEBAF Large Acceptance Spectrometer at the Thomas Jefferson National Accelerator Facility (JLab). The measured kinematical dependences are compared with published data and existing theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New measurements of the EMC effect in light nuclei

Modifications of structure functions in nuclei (EMC effect) suggest that the nuclear quark distribution function is not just the incoherent sum of the proton and neutron distributions, and made clear the importance of nuclear effects even in high energy measurements. Jefferson Lab experiment E03-103 made precise measurements of the EMC effect in few-body and heavy nuclei with emphasis on the large x region. Data from the light nuclei suggests that the nuclear dependence of the high x quark distribution may depend on the nucleon's local environment, rather than being a purely bulk effect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty analysis technique for OMEGA Dante measurements

The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions

A high density Langmuir probe array has been developed for measurements of scrape-off layer parameters in NSTX. Relevant scale lengths for heat and particle fluxes are 1-5 cm. Transient edge plasma events can occur on a time scale of several milliseconds, and the duration of a typical plasma discharge is {approx}1 s. The array consists of 99 individual electrodes arranged in three parallel radial rows to allow both swept and triple-probe operation and is mounted in a carbon tile located in the lower outer divertor of NSTX between two segments of the newly installed liquid lithium divertor. Initial swept probe results tracking the outer strike point through probe flux measurements are presented.

36 MATERIALS SCIENCE↗

A synchronized emissive probe for time-resolved plasma potential measurements of pulsed discharges

A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals

The elliptically curved pentaerythritol (PET) crystals used in the Supersnout 2 x-ray spectrometer on the National Ignition Facility at Lawrence Livermore National Laboratory have been calibrated photometrically in the range of 5.5-16 keV. The elliptical geometry provides broad spectral coverage and minimizes the degradation of spectral resolution due to the finite source size. The reflectivity curve of the crystals was measured using a x-ray line source. The integrated reflectivity (R{sub I}) and width of its curve ({Delta}{Theta}) were the measurements of major interest. The former gives the spectrometer throughput, and the latter gives the spectrometer resolving power. Both parameters are found to vary considerably with the radius of curvature of the crystal and with spectral energy. The results are attributed to an enhanced mosaic effect due to the increase in curvature. There are also contributions from the crystal cleaving and gluing processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A shallow underground laboratory for low-background radiation measurements and materials development

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗