Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Selective Recovery of Rare Earth Elements from Coal Fly Ash Leachates Using Liquid Membrane Processes

Coal combustion residues and other geological waste materials have been proposed as a resource for rare earth elements (REEs, herein defined as the 14 stable lanthanides, yttrium, and scandium). The extraction of REEs from residues often generate acidified leachates that require highly selective separation methods to recover the REEs from other major soluble ions in the leachates. We studied two liquid membrane processes (liquid emulsion membranes, LEM, and supported liquid membranes, SLM) and compared them to standard solvent extraction techniques for selective recovery and concentration of REEs from a leachate of coal fly ash. All separation methods involved an organic solution of di(2-ethylhexyl)phosphoric acid dissolved in kerosene or mineral oil and an acid strippant solution of 5 M nitric acid for the liquid-based separations. The LEM configuration, which separated REEs by immersing an acid-in-oil emulsion in the ash leachate, resulted in similar recovery percentages of individual REEs as the conventional solvent extraction approach. The recovery of REEs in the SLM configuration, which involved the impregnation of the solvent in a hydrophobic membrane, was slower than the LEM process. However, the SLM process was notably more selective for the heavy (and higher value) REEs, while the conventional extraction and LEM processes were more selective for the light REEs. A flux-based model of the extraction processes suggested that recovery rates were limited by REE affinity for the solvent chelator in the SLM, while the rates of REEs separation via LEM were limited by diffusive mass transfer across the liquid membrane. Altogether, these results help to identify specific steps in the recovery process that future work should target in the development of scalable liquid membrane separations for REE recovery.

42 ENGINEERING↗

Low-energy ion beam-based deposition of gallium nitride

An ion source with a remote plasma chamber excited by a 13.56 MHz radio frequency power was used for low-energy broad ion beam extraction. Optical emission spectral analyses showed the sputtering and postionization of a liquid gallium (Ga) target placed in a chamber separated from the source bombarded by argon (Ar) plasma guided by a bent magnetic field. In addition, an E × B probe successfully showed the extraction of low-energy Ga and Ar ion beams using a dual-electrode extractor configuration. By introducing dilute amounts of nitrogen gas into the system, formation of thin Ga-based films on a silicon substrate was demonstrated as determined from X-ray diffraction and X-ray reflectivity studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization and Catalytic Transfer Hydrogenolysis of Deep Eutectic Solvent Extracted Sorghum Lignin to Phenolic Compounds

Deep eutectic solvent (DES) is intrinsically cheaper than many ionic liquids (ILs) due to low precursor cost, simple synthesis, and improved recyclability. Meanwhile, DES can be as effective as ILs toward dissolving lignin from plant materials. However, the lignin depolymerization mechanism in DES, the structural and chemical properties of DES-extracted lignin (DES-EL), and the possible valorization pathways of DES-EL toward value-added products were not well understood. This paper aims to characterize the lignin streams from DES (1:2 choline chloride:lactic acid) treated sorghum and further upgrade the extracted lignin to phenolic compounds. As revealed by HSQC, 13 C, and 31 P NMR analysis, DES cleaved nearly all ether linkages in native lignin, resulting in significant size reduction. We further catalytically upgraded DES-EL to phenolic compounds via catalytic transfer hydrogenolysis in the presence of isopropyl alcohol. Among the three tested catalysts (Ru/C, Pd/C, and Pt/C), Ru/C proved the most effective in deconstructing DES-EL, with oil, char, and gas yields of 36.3, 46.4, 17.3 wt %, respectively. Major lignin monomeric products in the oil were phenol, 4-ethylphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-propylphenol, and 4-hydroxy-benzenepropanoic acid. Finally, this study provides a mechanistic understanding of lignin depolymerization in DES and demonstrates a possible way to catalytic upgrading of DES-EL to low molecular weight phenolic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory-scale integrated ARP filter test

The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. There is a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. This task attempted to simulate the entire ARP process, including multiple batches (5), washing, chemical cleaning, and blending the feed with heels and recycle streams. The objective of the tests was to determine whether one of these processes is causing excessive fouling of the crossflow or secondary filter. The authors conducted the tests with feed solutions containing 6.6 M sodium Salt Batch 6 simulant supernate with no MST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC

The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises two induction planes and one collection sense wire plane with a total of 8256 wires. Current induced on each TPC wire is amplified and shaped by custom low-power, low-noise ASICs immersed in the liquid argon. The digitization of the signal waveform occurs outside the cryostat. Using data from the first year of MicroBooNE operations, several excess noise sources in the TPC were identified and mitigated. The residual equivalent noise charge (ENC) after noise filtering varies with wire length and is found to be below 400 electrons for the longest wires (4.7 m). The response is consistent with the cold electronics design expectations and is found to be stable with time and uniform over the functioning channels. This noise level is significantly lower than previous experiments utilizing warm front-end electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization electron signal processing in single phase LArTPCs. Part I. Algorithm Description and quantitative evaluation with MicroBooNE simulation

Here, we describe the concept and procedure of drifted-charge extraction developed in the MicroBooNE experiment, a single-phase liquid argon time projection chamber (LArTPC). This technique converts the raw digitized TPC waveform to the number of ionization electrons passing through a wire plane at a given time. A robust recovery of the number of ionization electrons from both induction and collection anode wire planes will augment the 3D reconstruction, and is particularly important for tomographic reconstruction algorithms. A number of building blocks of the overall procedure are described. The performance of the signal processing is quantitatively evaluated by comparing extracted charge with the true charge through a detailed TPC detector simulation taking into account position-dependent induced current inside a single wire region and across multiple wires. Some areas for further improvement of the performance of the charge extraction procedure are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Determination of the Dynamic Hydraulic Transfer Function for the J-2X Oxidizer Turbopump: Methodology - Part One

An advanced methodology for extracting the hydraulic dynamic pump transfer matrix (Yp) for a cavitating liquid rocket engine turbopump inducer+impeller has been developed. The transfer function is required for integrated vehicle pogo stability analysis as well as optimization of local inducer pumping stability. Laboratory pulsed subscale waterflow test of the J-2X oxygen turbo pump is introduced and our new extraction method applied to the data collected. From accurate measures of pump inlet and discharge perturbational mass flows and pressures, and one-dimensional flow models that represents complete waterflow loop physics, we are able to derive Yp and hence extract the characteristic pump parameters: compliance, pump gain, impedance, mass flow gain. Detailed modeling is necessary to accurately translate instrument plane measurements to the pump inlet and discharge and extract Yp. We present the MSFC Dynamic Lump Parameter Fluid Model Framework and describe critical dynamic component details. We report on fit minimization techniques, cost (fitness) function derivation, and resulting model fits to our experimental data are presented. Comparisons are made to alternate techniques for spatially translating measurement stations to actual pump inlet and discharge.

Zoladz, Tom↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗

Recovery of dilute aqueous butanol by membrane vapor extraction with dodecane or mesitylene

A novel, nearly isothermal, nonselective-membrane separation process, membrane vapor extraction (MVE), efficiently recovers butanol from a dilute aqueous solution, for example, from a fermentation broth (Liu et al., 2015). In MVE, feed and solvent liquids are not in contact; they are separated by vapor. Therefore, compared to conventional extraction, MVE avoids formation of difficult-to-separate emulsions. In MVE, a semi-volatile aqueous solute (e.g., butanol) vaporizes at the upstream side of a membrane, diffuses as a vapor through the membrane pores, and subsequently condenses and dissolves into a high-boiling nonpolar solvent, favorable to the solute but not to water. Design analysis of a 1.5-m long, 30-m 2 membrane-area countercurrent MVE unit for processing 2-wt% aqueous butanol by dodecane solvent at 40 °C indicates over 90% recovery of the feed butanol with essentially no water loss and with very low energy requirement (Liu et al., 2015). The separation factor is over 1500. However, the published design study gives no experimental evidence for the calculated MVE separation. Here, we present experimental data to validate the MVE process. We use an omniphobic (i.e., hydrophobic and oleophobic), 0.2-µm pore-diameter Versapor®200 R membrane (Pall Corporation, Exton, PA) housed in a 6-cm wide by 10-cm long plate-and-frame channeled flow cell with 0.8-cm gap thickness. Membrane transfer area is 28 cm 2 . The membrane flow cell is designed for minimal axial concentration change and is operated in the transient mode between two recirculating flow loops. 2-wt% aqueous butanol is extracted into dodecane or mesitylene at 25 or 40 °C. Also, 1.5-wt% furfural is extracted into dodecane at 40 °C. Since vapor transport across the membrane contributes minimal resistance, MVE performance is governed by mass transfer through feed and solvent boundary layers. Mass-transfer coefficients are determined from the Graetz-Lévêque analysis of laminar thin-slit flow (Bird et al., 2002). Predicted extraction performance agrees well with experiment using no adjustable parameters. Finally, consistent with the initial multistage-design analysis (Liu et al., 2015), our new bench-scale experimental results confirm that MVE is a viable separation process to recover dilute semi-volatile biosolutes from water with minimal energy requirement. Preliminary analysis of downstream solute recovery from the extract via distillation is more efficient than that for pervaporation because of insignificant water carry over through the MVE membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Modeling of Self-Pressurization and Pressure Control by Thermodynamic Vent System in a Cryogenic Tank

This paper presents a numerical model of a system-level test bed - the multipurpose hydrogen test bed (MHTB) using Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a fully integrated space transportation vehicle liquid hydrogen (LH2) propellant tank and was tested at Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume based network flow analysis software developed at MSFC and used for thermo-fluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger, and a mixing pump and spray to extract thermal energy from the tank without significant loss of liquid propellant. Two GFSSP models (Self-Pressurization & TVS) were separately developed and tested and then integrated to simulate the entire system. Self-Pressurization model consists of multiple ullage nodes, propellant node and solid nodes; it computes the heat transfer through Multi-Layer Insulation blankets and calculates heat and mass transfer between ullage and liquid propellant and ullage and tank wall. TVS model calculates the flow through J-T valve, heat exchanger and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. The integrated models results have been compared with MHTB test data of 50% fill level. Satisfactory comparison was observed between test and numerical predictions.

Majumdar, Alok↗

Prevalence of Eight Phthalate Monoesters in Water from the Okavango Delta, Northern Botswana

Phthalate diesters are used in personal care products, plastics, and pesticides, resulting in widespread human and wildlife exposure. Phthalate diesters leach out of these products and ultimately enter biological systems where they are quickly metabolized to phthalate monoesters and glucuronides. As such, phthalate monoesters can serve as indicators of anthropogenic activity in wilderness areas. The Okavango Delta, an inland seasonal wetland covering 5000–12,000 km{sup 2} in Botswana, provides fresh water to many species of birds, fish, reptiles, and large mammals. Water samples (N = 46) were taken from across the Okavango water system, extracted, and analyzed for eight different phthalate monoesters using liquid chromatography and isotope dilution mass spectrometry. Seven of eight phthalate monoesters were detected from the low ng/L to low µg/L levels. Phthalate monoesters were found in samples from all five sampling regions. Sources of these contaminants are unknown, but their presence indicates encroachment of human activity on the Okavango Delta.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

13 C-Isotope-Assisted Assessment of Metabolic Quenching During Sample Collection from Suspension Cell Cultures

Metabolomics and fluxomics are core approaches to directly profile and interrogate cellular metabolism in response to various genetic or environmental perturbations. In order to accurately measure the abundance and isotope enrichment of intracellular metabolites, cell culture samples must be rapidly harvested and cold-quenched to preserve the in vivo metabolic state of the cells at the time of sample collection. When dealing with suspension cultures, this process is complicated by the need to separate the liquid culture media from cellular biomass prior to metabolite extraction. Here, we examine the efficacy of several commonly used metabolic quenching methods, using the model cyanobacterium Synechocystis sp. PCC 6803 as an example. Multiple 13 C-labeled compounds, including 13 C-bicarbonate, 13 C-glucose and 13 C-glutamine, were used as tracers during the sample collection and cold-quenching process to assess the extent of metabolic turnover after cells were harvested from culture flasks. We show that the combination of rapid filtration followed by 100% cold (–80°C) methanol quenching exhibits the highest quenching efficiency, while mixing cell samples with a partially frozen 30% methanol slurry (–24°C) followed by centrifugation is slightly less effective at quenching metabolism but enables less laborious sample processing. By contrast, rapidly mixing the cells with a saline ice slurry (~0°C) is less effective as indicated by high isotope-labeling rates after sample harvest, while mixing the cells with 60% cold methanol (–65°C) prior to centrifugation causes significant metabolite loss. Furthermore, this study demonstrates a rigorous, quantitative, and broadly applicable method for assessing the metabolic quenching efficacy of protocols used for sample collection in metabolomics and fluxomics studies.

59 BASIC BIOLOGICAL SCIENCES↗

Primary fission fragment mass yields across the chart of nuclides

In this work, we have calculated a complete set of primary fission fragment mass yields, Y(A), for heavy nuclei across the chart of nuclides, including those of particular relevance to the rapid neutron capture process (r process) of nucleosynthesis. We assume that the nuclear shape dynamics are strongly damped, which allows for a description of the fission process via Brownian shape motion across nuclear potential-energy surfaces. The macroscopic energy of the potential was obtained with the Finite-Range Liquid-Drop Model (FRLDM), while the microscopic terms were extracted from the single-particle level spectra in the fissioning system by the Strutinsky procedure for the shell energies and the BCS treatment for the pairing energies. For each nucleus considered, the fission fragment mass yield, Y(A), is obtained from 50 000 to 500 000 random walks on the appropriate potential-energy surface. The full mass and charge yield, Y(Z,A), is then calculated by invoking the Wahl systematics. With this method, we have calculated a comprehensive set of fission-fragment yields from over 3800 nuclides bounded by 80 ≤ Z ≤ 130 and A ≤ 330; these yields are provided as an ASCII formatted database in the Supplemental Material. We compare our yields to known data and discuss general trends that emerge in low-energy fission yields across the chart of nuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trends of Neutron Skins and Radii of Mirror Nuclei from First Principles

The neutron skin of atomic nuclei impacts the structure of neutron-rich nuclei, the equation of state of nucleonic matter, and the size of neutron stars. Here we predict the neutron skin of selected light- and medium-mass nuclei using coupled-cluster theory and the auxiliary field diffusion Monte Carlo method with two- and three-nucleon forces from chiral effective field theory. We find a linear correlation between the neutron skin and the isospin asymmetry in agreement with the liquid-drop model and compare with data. We also extract the linear relationship that describes the difference between neutron and proton radii of mirror nuclei and quantify the effect of charge symmetry breaking terms in the nuclear Hamiltonian. In conclusion, our results for the mirror-difference charge radii and binding energies per nucleon agree with existing data.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of the PrimEx $\eta$ experiment at Jefferson Lab

The GlueX detector in the experimental Hall D at Jefferson Lab offers a unique opportunity to perform a measurement of the decay width of eta mesons through the Primakoff effect. The experiment complements the physics program at Jefferson Lab on measuring the decay width of light pseudoscalar mesons via the Primakoff process. The goal of the experiment is to measure differential cross sections of eta mesons at forward angles using a beam of tagged photons incident on a liquid 4He target, which will be used for the extraction of the decay width. This measurement is vital for understanding fundamental properties like the ratios of the light quark masses and the eta - eta' mixing angle, and will provide an important test of chiral symmetry breaking in QCD. Our experimental results will help reduce uncertainties on partial widths of all other eta decays. The experiment collected data during three physics runs between 2019 and 2022. We will give an overview of the PrimEx eta experiment and the current status of our data analyses. We will also discuss the feasibility of conducting future Primakoff measurements in light of the recent upgrade of the GlueX forward calorimeter and the potential accelerator energy upgrade to 22 GeV.

Somov, Alexander↗

High Temperature NASP Engine Seal Development

This video details research being conducted at the Lewis Research Center on high temperature engine seal design for the National Aerospace Plane. To maximize the speed, the jets on the NASP extract oxygen from the air rather than carry large liquid fuel tanks; this creates temperatures within the jet of over 5000 F. To prevent these potentially explosive gases from escaping, researchers are developing new technologies for use in the engine seals. Two examples explained are the ceramic wafer seal and the braided ceramic rope seal. Computer simulations and laboratory footage are used to illustrate the workings of these seals. Benefits for other aerospace and industrial applications, as well as for the space shuttle, are explored.

Source record↗