Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Level Set”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Search for the rare decay $K^+\to\mu^+\nu\bar\nu\nu$

Evidence of the $K^+\to\mu^+\nu\bar\nu\nu$ decay was searched for using E949 experimental data with an exposure of $1.70\times 10^{12}$ stopped kaons. The data sample is dominated by the backgrond process $K^+\to\mu^+\nu_\mu\gamma$. An upper limit on the decay rate $\Gamma(K^+\to\mu^+\nu\bar\nu\nu)< 2.4\times 10^{-6}\Gamma(K^+\to all)$ at 90% confidence level was set assuming the Standard Model muon spectrum. The data are presented in such a way as to allow calculation of rates for any assumed $\mu^+$ spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived scalar particles in B + → K + χ ( μ + μ – ) decays

A search for a long-lived scalar particle χ is performed, looking for the decay B + →K + χ with χ→μ + μ – in pp collision data corresponding to an integrated luminosity of 3 fb –1 , collected by the LHCb experiment at center-of-mass energies of √s = 7 and 8 TeV. This new scalar particle, predicted by hidden sector models, is assumed to have a narrow width. The signal would manifest itself as an excess in the dimuon invariant mass distribution over the Standard Model background. No significant excess is observed in the accessible ranges of mass 250 < m(χ) < 4700 MeV/c 2 and lifetime 0.1 < τ(χ) < 1000 ps. Upper limits on the branching fraction B(B + →K + χ(μ + μ – )) at 95% confidence level are set as a function of m(χ) and τ(χ), varying between 2 × 10 –10 and 10 –7 . These are the most stringent limits to date. The limits are interpreted in the context of a model with a light inflaton particle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for low-mass resonances decaying into bottom quark-antiquark pairs in proton-proton collisions at s = 13 TeV

A search for narrow, low-mass, scalar, and pseudoscalar resonances decaying to bottom quark-antiquark pairs is presented. The search is based on events recorded in $\sqrt{s} =$ 13 TeV proton-proton collisions with the CMS detector at the LHC, collected in 2016, and corresponding to an integrated luminosity of 35.9 fb -1 . The search selects events in which the resonance would be produced with high transverse momentum because of the presence of initial- or final-state radiation. In such events, the decay products of the resonance would be reconstructed as a single large-radius jet with high mass and two-prong substructure. A potential signal would be identified as a narrow excess in the jet invariant mass spectrum. No evidence for such a resonance is observed within the mass range from 50 to 350 GeV, and upper limits at 95% confidence level are set on the product of the cross section and branching fraction to a bottom quark-antiquark pair. Lastly, these constitute the first constraints from the LHC on exotic bottom quark-antiquark resonances with masses below 325 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for New Phenomena in tt¯ Events with Large Missing Transverse Momentum in Proton-Proton Collisions at √s=7 TeV with the ATLAS Detector

A search for new phenomena in tt¯ events with large missing transverse momentum in proton-proton collisions at a center-of-mass energy of 7 TeV is presented. The measurement is based on 1.04 fb⁻¹ of data collected with the ATLAS detector at the LHC. Contributions to this final state may arise from a number of standard model extensions. The results are interpreted in terms of a model where new top-quark partners are pair produced and each decay to an on-shell top (or antitop) quark and a long-lived undetected neutral particle. The data are found to be consistent with standard model expectations. A limit at 95% confidence level is set excluding a cross section times branching ratio of 1.1 pb for a top-partner mass of 420 GeV and a neutral particle mass less than 10 GeV. In a model of exotic fourth generation quarks, top-partner masses are excluded up to 420 GeV and neutral particle masses up to 140 GeV.

Aad, G.↗

Search for Invisible Decays of a Higgs Boson Produced in Association with a Z Boson in ATLAS

A search for evidence of invisible-particle decay modes of a Higgs boson produced in association with a Z boson at the Large Hadron Collider is presented. No deviation from the standard model expectation is observed in 4.5 fb -1 (20.3 fb -1 ) of 7 (8) TeV pp collision data collected by the ATLAS experiment. Assuming the standard model rate for ZH production, an upper limit of 75%, at the 95% confidence level is set on the branching ratio to invisible-particle decay modes of the Higgs boson at a mass of 125.5 GeV. The limit on the branching ratio is also interpreted in terms of an upper limit on the allowed dark matter-nucleon scattering cross section within a Higgs-portal dark matter scenario. Within the constraints of such a scenario, the results presented in this Letter provide the strongest available limits for low-mass dark matter candidates. Limits are also set on an additional neutral Higgs boson, in the mass range 110 < m H < 400 GeV, produced in association with a Z boson and decaying to invisible particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Baryon-Number Violating Ξ b 0 Oscillations

A search for baryon-number violating Ξ 0 b oscillations is performed with a sample of pp collision data recorded by the LHCb experiment, corresponding to an integrated luminosity of 3 fb -1 . The baryon number at the moment of production is identified by requiring that the Ξ 0 b come from the decay of a resonance Ξ* b - → Ξ 0 b π - or Ξ' b - → Ξ 0 b π - , and the baryon number at the moment of decay is identified from the final state using the decays Ξ 0 b → Ξ + c π - , Ξ + c → pK - π + . No evidence of baryon-number violation is found, and an upper limit at the 95% confidence level is set on the oscillation rate of ω < 0.08 ps -1 , where ω is the associated angular frequency.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of the Rare Purely Baryonic Decay B 0 → p p ¯

The first observation of the decay of a B 0 meson to a purely baryonic final state, B 0 → p p ¯ , is reported. The proton-proton collision data sample used was collected with the LHCb experiment at center-of-mass energies of 7 and 8 TeV and corresponds to an integrated luminosity of 3.0 fb - 1 . The branching fraction is determined to be B ( B 0 → p p ¯ ) = ( 1.25 ± 0.27 ± 0.18 ) × 10 - 8 , where the first uncertainty is statistical and the second systematic. The decay mode B 0 → p p ¯ is the rarest decay of the B 0 meson observed to date. The decay B s 0 → p p ¯ is also investigated. No signal is seen and the upper limit B ( B s 0 → p p ¯ ) < 1.5 × 10 - 8 at 90% confidence level is set on the branching fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Low-Mass Quark-Antiquark Resonances Produced in Association with a Photon at $\sqrt{s} = 13 \mathrm{ TeV}$

A search for narrow low-mass resonances decaying to quark-antiquark pairs is presented. The search is based on proton-proton collisions events collected at 13 TeV by the CMS detector at the CERN LHC. The data sample corresponds to an integrated luminosity of $\mathrm{35.9 fb^{-1}}$, recorded in 2016. The search considers the case where the resonance has high transverse momentum due to initial-state radiation of a photon. To study this process, the decay products of the resonance are reconstructed as a single large-radius jet with two-pronged substructure. The signal is identified as a localized excess in the jet invariant mass spectrum. No evidence for such a resonance is observed in the mass range 10 to 125 GeV. Upper limits at the 95% confidence level are set on the coupling strength of vector resonances decaying to quark pairs. The results obtained with this novel technique provide the first direct constraints on quark-antiquark resonance masses below 50 GeV obtained at a hadron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Supersymmetry with a Compressed Mass Spectrum in Events with a Soft $\tau$ Lepton, a Highly Energetic Jet, and Large Missing Transverse Momentum in Proton-Proton Collisions at $\sqrt{s}=$ TeV

The first search for supersymmetry in events with an experimental signature of one soft, hadronically decaying τ lepton, one energetic jet from initial-state radiation, and large transverse momentum imbalance is presented. These event signatures are consistent with direct or indirect production of scalar τ leptons (τ˜) in supersymmetric models that exhibit coannihilation between the τ˜ and the lightest neutralino (χ˜10), and that could generate the observed relic density of dark matter. The data correspond to an integrated luminosity of 77.2 fb-1 of proton-proton collisions at s=13 TeV collected with the CMS detector at the LHC in 2016 and 2017. The results are interpreted in a supersymmetric scenario with a small mass difference (Δm) between the chargino (χ˜1±) or next-to-lightest neutralino (χ˜20), and the χ˜10. The mass of the τ˜ is assumed to be the average of the χ˜1± and χ˜10 masses. The data are consistent with standard model background predictions. Upper limits at 95% confidence level are set on the sum of the χ˜1±, χ˜20, and τ˜ production cross sections for Δm(χ˜1±,χ˜10)=50 GeV, resulting in a lower limit of 290 GeV on the mass of the χ˜1±, which is the most stringent to date and surpasses the bounds from the LEP experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Magnetic Monopole Pair Production in Ultraperipheral Pb + Pb Collisions at s NN = 5.36 TeV with the ATLAS Detector at the LHC

This Letter presents a search for highly ionizing magnetic monopoles in 262 μ b − 1 of ultraperipheral Pb + Pb collision data at s NN = 5.36 TeV collected by the ATLAS detector at the LHC. A new methodology that exploits the properties of clusters of hits reconstructed in the innermost silicon detector layers is introduced to study highly ionizing particles in heavy-ion data. No significant excess above the background, which is estimated using a data-driven technique, is observed. Using a nonperturbative semiclassical model, upper limits at 95% confidence level are set on the cross section for pair production of monopoles with a single Dirac magnetic charge in the mass range of 20–150 GeV. Depending on the model, monopoles with a single Dirac magnetic charge and mass below 80–120 GeV are excluded. © 2025 CERN, for the ATLAS Collaboration 2025 CERN

Aad, G. (ORCID:0000000266654934)↗

Search for the Rare Decay 𝐷 0 → 𝜇 + ⁢𝜇 − in Proton-Proton Collisions at $\sqrt{s}$ = 13.6 TeV

A search for the rare decay 𝐷 0 → 𝜇 + ⁢𝜇 − is reported using proton-proton collision events at $\sqrt{s}$ =13.6 TeV collected by the CMS detector in 2022–2023, corresponding to an integrated luminosity of 64.5 fb −1 . This is the first analysis to use a newly developed inclusive dimuon trigger, expanding the scope of the CMS flavor physics program. The search uses 𝐷 0 mesons obtained from 𝐷* + → 𝐷 0 ⁢𝜋 + decays. No significant excess is observed. A limit on the branching fraction of ℬ⁡(𝐷 0 → 𝜇 + ⁢𝜇 − ) < 2.4 × 10 −9 at 95% confidence level is set. This is the most stringent upper limit set on any flavor changing neutral current decay in the charm sector.

Charmed mesons↗

Hybrid Programming for Near-Term Quantum Computing Systems

Recent computations involving quantum processing units (QPUs) have demonstrated a series of challenges inherent to hybrid classical-quantum programming, compilation, execution, and verification and validation. Despite considerable progress, system-level noise, limited low-level instructions sets, remote access models, and an overall lack of portability and classical integration presents near-term programming challenges that must be overcome in order to enable reliable scientific quantum computing and support robust hardware benchmarking. In this work, we draw on our experience in programming QPUs to identify common concerns and challenges, and detail best practices for mitigating these challenges within the current hybrid classical-quantum computing paradigm. Following this discussion, we introduce the XACC quantum compilation and execution framework as a hardware and language independent solution that addresses many of these hybrid programming challenges. XACC supports extensible methodologies for managing a variety of programming, compilation, and execution concerns across the increasingly diverse set of QPUs. We use recent nuclear physics simulations to illustrate how the framework mitigates programming, compilation, and execution challenges and manages the complex workflow present in QPU-enhanced scientific applications. Finally, we codify the resulting hybrid scientific computing workflow in order to identify key areas requiring future improvement.

Mccaskey, Alex↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-09: Image Quality Comparison and Dose Quantification for 2.5 MV

Purpose: To compare the image quality of the 2.5MV imaging beam (2.5X-IMB) to that of a 6MV beam and to quantify the imaging dose of a 2.5X-IMB for constancy as specified by AAPM TG-142 Methods: The image quality of the 2.5X-IMB was compared to the 6MV imaging beam using the SNC ImagePro MV-QA phantom and the Varian supplied Las Vegas phantom (LVP). High resolution (1280×1280×16, 2 frames at 1.5MU/frame) and low resolution (640×640×16, 2 frames at 0.75MU/frame) images were compared for each phantom. MV-QA phantom images were evaluated quantitatively, and the LVP images were evaluated qualitatively. The imaging dose for 2.5X-IMB was quantified using the procedure outlined in TG51. PTWCC13-31013 chambers were used to measure a percent depth dose (PDD) curve for the 2.5X-IMB. All the factors described in TG51 were calculated using the 2.5X-IMB and a PTW30013 farmer chamber. Results: A comparison between 2.5X-IMB and 6MV image quality was performed both visually and with DoseLab software. The optimal window and level were set for each image of the LVP by the user. Visual inspection showed greater contrast resolution with the 2.5MV beam, but no significant difference with the change in imaging resolution. DoseLab reported similar spatial resolutions between the two energies, but the contrast-to-noise ratio (CNR) was greater for 2.5MV. The PDDx(10cm) for a 10x10cm2 field was measured to be 51.5%. Although this PDD value is off the scale of Figure 4 in TG51, the trend of the curve corresponding to the PTW31003 (equivalent) chamber led to an approximate kQ value of 1.00. Conclusion: When compared to 6MV imaging, 2.5X-IMB results in a better CNR. At low resolution, the DoseLab results for the two energies are comparable, but visual analysis favors the 2.5X-IMB images. Imaging dose was quantified for the 2.5X-IMB after following the TG51 methodology with appropriate approximations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.

60 APPLIED LIFE SCIENCES↗

SU-E-J-176: Characterization of Inter-Fraction Breast Variability and the Implications On Delivered Dose

Purpose: To systematically characterize inter-fraction breast variability and determine implications on delivered dose. Methods: Weekly port films were used to characterize breast setup variability. Five evenly spaced representative positions across the contour of each breast were chosen on the electronic port film in reference to graticule, and window and level was set such that the skin surface of the breast was visible. Measurements from the skin surface to treatment field edge were taken on each port film at each position and compared to the planning DRR, quantifying the variability. The systematic measurement technique was repeated for all port films for 20 recently treated breast cancer patients. Measured setup variability for each patient was modeled as a normal distribution. The distribution was randomly sampled from the model and applied as isocentric shifts in the treatment planning computer, representing setup variability for each fraction. Dose was calculated for each shifted fraction and summed to obtain DVHs and BEDs that modeled the dose with daily setup variability. Patients were categorized in to relevant groupings that were chosen to investigate the rigorousness of immobilization types, treatment techniques, and inherent anatomical difficulties. Mean position differences and dosimetric differences were evaluated between planned and delivered doses. Results: The setup variability was found to follow a normal distribution with mean position differences between the DRR and port film between − 8.6–3.5 mm with sigma range of 5.3–9.8 mm. Setup position was not found to be significantly different than zero. The mean seroma or whole breast PTV dosimetric difference, calculated as BED, ranged from a −0.23 to +1.13Gy. Conclusion: A systematic technique to quantify and model setup variability was used to calculate the dose in 20 breast cancer patients including variable setup. No statistically significant PTV or OAR BED differences were found between immobilization, treatment or anatomical differences investigated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-249: Determining the Sensitivity of Beam Profile Parameters for Detecting Energy Changes in Flattening Filter-Free Beams

Purpose: To identify the beam profile parameters that can be used to detect energy changes in a flattening filter-free photon beams. Methods: Flattening filter-free beam profiles (inline, crossline, and diagonals) were measured for multiple field sizes (25×25cm and 10×10cm) at 6MV on a clinical system (Truebeam, Varian Medical Systems Palo Alto CA). Profiles were acquired for baseline energy and detuned beams by changing the bending magnet current (BMC), above and below baseline. The following profile parameters were measured: flatness (off-axis ratio at 80% of field size), symmetry, uniformity, slope, and the off-axis ratio (OAR) at several off-axis distances. Tolerance values were determined from repeated measurements. Each parameter was evaluated for sensitivity to the induced beam changes, and the minimum detectable BMC change was calculated for each parameter by calculating the change in BMC that would Result in a change in the parameter above the measurement tolerance. Results: Tolerance values for the parameters were-Flatness≤0.1%; Symmetry≤0.4%; Uniformity≤0.01%; Slope≤ 0.001%/mm. The measurements made with a field size of 25cm and a depth of d=1.5cm showed the greatest sensitivity to bending magnet current variations. Uniformity had the highest sensitivity, able to detect a change in BMC of BMC=0.02A. The OARs and slope were sensitive to the magnitude and direction of BMC change. The sensitivity in the flatness parameter was BMC=0.04A; slope was sensitive to BMC=0.05A. The sensitivity decreased for OARs measured closer to central axis-BMC(8cm)=0.23A; BMC(5cm)=0.47A; BMC(2cm)=1.35A. Symmetry was not sensitive to changes in BMC. Conclusion: These tests allow for better QA of FFF beams by setting tolerance levels to beam parameter baseline values which reflect variations in machine calibration. Uniformity is most sensitive to BMC changes, while OARs provide information about magnitude and direction of miscalibration. Research funding provided by Varian Medical Systems. Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗