Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A heat-driven monochromatic light source

The efficiency with which heat may be converted into resonance radiation in a cesium thermionic diode is investigated theoretically. An analytical model of a thermionic converter is used which combines the coupled effects of line radiation transport, excited-state kinetics, and plasma diffusion. Operating regimes are established for various degrees of optical density in the plasma. The results indicate that monochromatic radiation can be produced with efficiencies on the order of 30 percent, provided that there is an adequate voltage drop across the plasma. A drop of 1 V was used since it can be maintained without any electrical power input to the device. It is found that high efficiencies are ude to the higher interelectrode distances which the solutions accommodate, and that radiation can be generated efficiently, even with optically dense gases.

Stefani, Francis↗

Proposal for a conceptually new compact collecting optics for powerful light sources

Testing of a spacecraft under simulated outer space conditions is the best guarantee for a successful mission, and for almost all of the parameters a good match (to within a few percent) may be reached in relevant test facilities (e.g., IR background, earthshine and albedo radiation, residual atmosphere, intensity stability, distribution and spectrum of the solar radiation). The collimation angle of the sun (32 arc min) is, however, a drastic exception, here only + or - 1.5 to 2 deg are achieved which means a relative deviation by nearly one order of magnitude. The main reason for this is the presently used collecting optics having unnecessary large diameters. Here a lens-mirror combination is proposed which allows the reduction of the diameter by nearly a factor of two and to achieve with the present Xenon arc lamps a collimation angle of + or - 0.8 deg.

Saenger, G.↗

An improved light source for laser ranging

The development of a new laser material, Cr-doped LiSAF, makes possible the development of a laser source for satellite ranging systems that is more superior in performance capabilities than current Nd:YAG-based laser sources. This new material offers the potential of shorter pulses and more preferable wavelengths (850 and 425 nm) than multiwavelength Nd:YAG systems, leading to superior ranging resolution and greater detection sensitivity. We are embarking on a feasibility study of a two-wavelength, mode-locked laser system based on Cr:LiSAF, providing shorter pulses for improved ranging resolution.

Hamal, Karel↗

The SeaWiFS Quality Monitor: A Portable Field Calibration Light Source

A portable and stable source, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Quality Monitor, has been developed for use as a field instrument. The source can be used with either radiance- or irradiance-measuring sensors to transfer the laboratory calibration to the field so that the stability of the sensors can be monitored during the experiment. Temperature-controlled silicon photodiodes with colored glass filters are used to monitor the stability of the SeaWiFS Quality Monitor.

Shaw, Ping-Shine↗

A Ground-based UV Light Source for the Euso Mission

The Extreme Universe Space Observatory (EUSO) mission will measure the uorescence signal produced by Extensive Air Showers (EAS). To determine the intrinsic shower luminance and hence the energy of the incident cosmic ray, a correction must be made for attenuation in the atmosphere. The correction will be determined on an event-by-event basis by atmospheric sounding with a LIDAR. We report here on a "ground truth" concept to verify EUSO's measurements of intrisic shower luminance.

Adams, J. H.↗

Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection

A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.

Non-NASA Center↗

Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Cathode luminescence light source for broadband applications in the visible spectrum

A device and method for generating cathode luminescence is provided. The device and method generate broad spectrum electromagnetic radiation in the visible. A layer of particles, such as quartz or alumina powder, is exposed to electrons in a plasma discharge. Surface excitation of these particles or the generations/excitation of F-center sites give rise to luminescence.

Foster, John E.↗

Nocturnal Aerosol Optical Depth Measurements with a Small-Aperture Automated Photometer Using the Moon as a Light Source

A method is described that enables the use of lunar irradiance to obtain nighttime aerosol optical depth (AOD) measurements using a small-aperture photometer. In this approach, the U.S. Geological Survey lunar calibration system was utilized to provide high-precision lunar exoatmospheric spectral irradiance predictions for a ground-based sensor location, and when combined with ground measurement viewing geometry, provided the column optical transmittance for retrievals of AOD. Automated multiwavelength lunar measurements were obtained using an unmodified Cimel-318 sunphotometer sensor to assess existing capabilities and enhancements needed for day/night operation in NASA s Aerosol Robotic Network (AERONET). Results show that even existing photometers can provide the ability for retrievals of aerosol optical depths at night near full moon. With an additional photodetector signal-to-noise improvement of 10-100, routine use over the bright half of the lunar phase and a much wider range of wavelengths and conditions can be achieved. Although the lunar cycle is expected to limit the frequency of observations to 30%-40% compared to solar measurements, nevertheless this is an attractive extension of AERONET capabilities.

Berkoff, Timothy A.↗

Biomolecular solution X-ray scattering at the National Synchrotron Light Source

In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulator-based beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished by utilizing a vacuum sample/detector chamber that is an integral part of the SAXS scattering flight path. This vacuum chamber allows a WAXS detector to be positioned at a close distance from the sample, while not interfering with scattered X-rays at small angles from reaching the SAXS detector. A regular training program, the X9 workbench, has also been established to allow users to become familiar with beamline X9 for solution X-ray scattering.

43 PARTICLE ACCELERATORS↗