Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Measurements of the EMC effect in few-body nuclei at large x

Recent data on the EMC effect from Jefferson Lab experiment E03103 suggest that the nuclear dependence of the high x quark distribution may depend on the local nuclear environment, rather than being a purely bulk effect. We briefly discuss the analysis and results of the E03103 experiment focusing on the light nuclei and high x region. In addition, we also discuss a future experiment at the upgraded 12 GeV Jefferson Lab facility which will further investigate the role of the local nuclear environment and the influence of detailed nuclear structure on the modification of quark distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ingot Niobium Summary

CBMM North America (formerly Reference Metals Company, a subsidiary of CBMM ~ Companhia Brasileira de Metalurgia e Minera~ao, Brazil) and Jefferson Lab entered into a Cooperative Research And Development Agreement (CRADA) in August 2004 to carry out mutually beneficial R&D on Pyrochlore based niobium for Superconducting Radio Frequency (SRF) accelerator applications. They jointly invented and patented the large grain niobium cavities built directly from the ingot niobium slices. During October 30 - November I, 2006, in collaboration with Jefferson Lab, CBMM hosted the first international workshop on single crystal ~ large grain niobium technology near the world's largest niobium mine in Araxa, Brazil. The deliberations of this workshop were published as American institute of Physics (AlP) Conference Proc~edings (CP) AlP CP 927. In 201 0, in collaboration with the industrial partner CBMM, Jefferson Lab hosted the first International Symposium on Superconducting Science and Technology of Ingot Niobium in Newport News Virginia, USA, from September 22 to 24. At this forum, university, industrial, and national research institution experts from around the world exchanged information and views on the status of ingot niobium science and technology and on the technology's advantages in obtaining high~ performance superconducting radio frequency (SRF) accelerator structures with reduced processing at lower cost. The international collaborators discussions on the ingot niobium technology were published as AlP CP 1352. On December 4th 2015 Jefferson Lab hosted Ingot Niobium Summary Workshop in collaboration with CBMM. At this workshop the ingot niobium technology collaborators from around the world presented reviews of their exciting work carried out during the past 11 years. The invited presenters are from Brazil, Germany, India, Italy, Japan and USA. A new book entitled, "Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications" with 16 invited chapters divided into three sections was released on the 3rd of December 2015. The projected applications of this high efficiency~low cost ingot niobium technology include medical/industrial radioisotopes, accelerator driven subcritical systems, energy recovery linacs, future circular colliders, FEL's and other technologies based on these ingot niobium SRF accelerators in stead of the present high purity polycrystalline niobium based high cost accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Timelike Compton Scattering

Generalized Parton Distributions (GPDs) have become a key concept in our studies of hadron structure in QCD. The measurement of suitable experimental observables and the extraction of GPDs from these data is one of the high priority 12 GeV programs at Jefferson Lab. Deeply Virtual Compton Scattering (DVCS) is generally thought of as the most promising channel for probing GPDs in the valence quark region. However, the inverse process, Timelike Compton Scattering (TCS) can provide an important complementary measurement, in particular of the real part of the Compton amplitude and power corrections at intermediate values of Q{sup 2}. The first studies of TCS using real tagged and quasi-real untagged photons were performed in Hall B at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise polarization measurements via detection of compton scattered electrons

The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shape Evolution of C75 Large-Grain Niobium Half-Cells During Cavity Fabrication

The largely anisotropic deformation of large-grain Nb discs during deep drawing into half-cells poses a challenge for achieving a desired shape accuracy. Two 5-cell cavities for the C75 CEBAF cryomodule rework program have been fabricated at Jefferson Lab from large-grain Nb discs directly sliced from an ingot. The shape of the inner surface of eight half-cells has been inspected using a FARO Edge laser scanner during the fabrication process and compared to the reference shape. On average, approximately 63% of the half-cell inner surface was found to be within 0.1 mm of the reference shape and ~90% to be within 0.2 mm, after the final equator machining. Several 5-cell C75 cavities have also been fabricated at Research Instruments, Germany, and measurements of the shape accuracy using a Zeiss 3D coordinate measuring machine gave similar results. One half-cell was measured both at Research Instruments and Jefferson Lab for comparison.

Ciovati, G.↗

New Measurements of the European Muon Collaboration Effect in Very Light Nuclei

New Jefferson Lab data are presented on the nuclear dependence of the inclusive cross section from {sup 2}H, {sup 3}He, {sup 4}He, {sup 9}Be and {sup 12}C for 0.3<x<0.9, Q{sup 2}{approx_equal}3-6 GeV{sup 2}. These data represent the first measurement of the EMC effect for {sup 3}He at large x and a significant improvement for {sup 4}He. The data do not support previous A-dependent or density-dependent fits to the EMC effect and suggest that the nuclear dependence of the quark distributions may depend on the local nuclear environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Magnetized Injector for Electron Cooling Applications

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility uses the existing ion/proton facility and augments it with an electron accelerator. Jefferson Lab plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require that the ion beams be cooled in order to reach the lu- minosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunch beam cooling, while Jefferson Lab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions such as flat beam klystrons, and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high performance injectors for electron cooling is limited, the potential market for high frequency RF sources and compact X-ray systems is considerable. Thus, the design methodologies developed in this project have a wide range of applicability. In this Phase I project, Xelera Research LLC performed simulations and calculations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and techniques that can then be applied to specific machine designs or other applications requiring magnetized injectors. In Phase II, the design will be further optimized, and then built in collaboration with a national lab partner. Xelera Research has many years of experience with electron sources and all of the skills and tools necessary to successfully carry out this project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Three-Nucleon Short Range Correlations in Inclusive Electron Scattering

Inclusive electron scattering is a powerful tool to study short range correlations (SRCs) in nuclei. Two nucleon SRCs (2N-SRCs) were first observed in data from SLAC and further studied at Jefferson Lab, appearing, between $1.4 < x< 2$, as plateaus in the per nucleon cross section ratio of heavy to light nuclei. The Jefferson Lab experiments also provided the first evidence of three nucleon SRCs (3N-SRCs) at $x>2$. However, because of limited statistics of the earlier experiments, the scaling behavior of 3N-SRCs is not well established. Jefferson Lab experiment E08014 ran in April and May of 2011 in Hall~A and aimed to study the onset of 3N-SRCs with better accuracy and, for the first time, to examine the isospin dependence of SRCs. The experiment will be briefly described followed by a discussion of the data analysis and the presentation of the preliminary results.

Ye, Zhihong↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Electroproduction of À0 in the resonance region at high Q2 with CLAS

An extensive program is underway at Jefferson Lab to study the eletromagnetic excitations of baryon states. We report the analysis of exclusive single ?0 electroproduction in the resonance region at Jefferson Lab in the Q2 range of 2 to 6 GeV2/c2. A longitudinally polarized 5.75 GeV electron beam was incident on a 5 cm long liquid Hydrogen target. The CLAS spectrometer at Jefferson Lab was used to detect the final state particles. The data was taken between October 2001 and January 2002. Preliminary results for differential cross sections over the entire 4? c.m. solid angle will be presented. This high precision measurement will allow us to access the structure and dynamics of nucleon excitations with masses up to 2 GeV.

Ungaro, Maurizio↗

Introduction to Ingot Niobium

Superconducting radiofrequency (SRF) technology using niobium accelerating cavities was first applied at large scale in the recirculating electron linear accelerator CEBAF—the Continuous Electron Beam Accelerator Facility in Newport News, Virginia, USA, at what is now called Thomas Jefferson National Accelerator Facility, or Jefferson Lab. Building on the high quality factors and peak magnetic fields found in low residual resistivity ratio (low-RRR) solid niobium in the 1970s, Jefferson Lab has reintroduced ingot niobium technology. High tantalum content in ingot niobium is not expected to negatively impact cavity performance, but will reduce the cost of accelerator structures considerably. Optimized low-cost CW linear accelerators built with ingot niobium will show the way for future R&D and industrial applications. This paper portrays the Jefferson Lab SRF context, reviews the early history of ingot niobium technology from over a third of a century ago, explains the technical advantages of that technology's recent reintroduction, and presents the outlook for further development.

43 PARTICLE ACCELERATORS↗

Introduction to Ingot Niobium

Superconducting radiofrequency (SRF) technology using niobium accelerating cavities was first applied at large scale in the recirculating electron linear accelerator CEBAF--the Continuous Electron Beam Accelerator Facility in Newport News, Virginia, USA, at what is now called Thomas Jefferson National Accelerator Facility, or Jefferson Lab. Building on the high quality factors and peak magnetic fields found in low residual resistivity ratio (low-RRR) solid niobium in the 1970s, Jefferson Lab has reintroduced ingot niobium technology. High tantalum content in ingot niobium is not expected to negatively impact cavity performance, but will reduce the cost of accelerator structures considerably. Optimized low-cost CW linear accelerators built with ingot niobium will show the way for future R and D and industrial applications. This paper portrays the Jefferson Lab SRF context, reviews the early history of ingot niobium technology from over a third of a century ago, explains the technical advantages of that technology's recent reintroduction, and presents the outlook for further development.

36 MATERIALS SCIENCE↗

Thomas Jefferson National Accelerator Facility

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. The technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.

43 PARTICLE ACCELERATORS↗

The Experimental Programs on Light Pseudoscalar Meson Decays

The decays of the low-lying pseudoscalar mesons (?0, ?, and ??) allow access to a plethora of physics probes, from measurements of fundamental properties of matter such as the up-down quark mass ratio, to studies of channels that access higher-order terms in Chiral Perturbation theory, to tests of fundamental symmetries and searches for signatures of physics beyond the Standard Model. Several experiments have studied pseudoscalar decays: these experiments include PrimEx in Hall B at Jefferson Lab, A2 at the MAMI electron accelerator facility, the KLOE-II experiment at the DA?NE ?-factory, WASA-at-COSY at the cooler synchrotron COSY storage ring, and BESIII at the Beijing charm factory. In Hall D at Jefferson Lab, PrimEx-eta uses the Primakoff process to measure the ? radiative width using the GlueX spectrometer. In the near future the Jefferson Lab Eta Factory (JEF) experiment will use the GlueX spectrometer with an upgraded forward calorimeter to study ?(?) decay channels with a focus on all-neutral final states. Finally, a proposal for a new experiment, ``Rare Eta Decays with a TPC for Optical Photons'' (REDTOP) utilizing a proton beam on fixed targets, is under development. Highlights from previous and ongoing experiments and plans for future experiments will be presented.

Taylor, Simon↗

Low Profile Detector for Breast Specific Gamma Imaging

Jefferson Lab (JLab), Dilon Technologies (Dilon) and Hampton University (HU) entered into a research CRADA project titled: “Low Profile Detector for Breast Specific Gamma Imaging.” Dr. Benjamin Welch, Director of Research and Development/Engineering was the Principal Investigator for the detector project for Dilon. Dr. Nicholas Kenny was the Principal Investigator for the project for HU. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and acted as the chief contact with Dilon and HU. The responsibility of Jefferson Lab was the development and construction of detector instrumentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics Prospects with GlueX

The new experiment GlueX is currently being constructed at Jefferson Lab. The experiment was designed to search for hybrid mesons with exotic-quantum-numbers using a beam of linearly polarized photons incident on a liquid hydrogen target. We will discuss the discovery potential of the GlueX experiment and briefly overview its physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Advanced Machine Learning and Artificial Intelligence System for Demonstrating Radiation Regulatory Compliance in DOE Accelerator Facilities

In this Phase II proposal, Applied Research LLC (ARLLC), Thomas Jefferson National Accelerator Facility (Jefferson Lab), and Old Dominion University (ODU) propose the combination of domain knowledge (beam characteristics, fixed structural shielding, earthen burden (the soil and foliage added to the dome of the experimental halls as additional shielding), etc.), machine learning (ML) and/or artificial intelligence (AI) to correlate a variety of multi-modal onsite signals and the radiation fields seen in accessible areas of the accelerator site and the site boundary. The ML/AI will consider the complex influence of environmental parameters affecting the radon contribution of the measurements, focusing on actual data obtained from Jefferson Lab. In Phase I, the coded beam and location data were fed into a deep learning model to predict doses at several designated locations in Jefferson Lab’s facility. Moreover, a dense radiation map was generated using only a sparse collection of the samples in a facility. In Phase II, we will develop a software prototype containing a radiation prediction algorithm, dense radiation map algorithms, and background noise prediction algorithms, with actual data used to evaluate the prototype. This work will provide a framework for evaluation of radiation measurement results around the site based on learned responses. In addition, the proposed approach allows more granular mapping of radiation levels. Better understanding and communication of these levels is related to the overall approach in keeping doses to personnel ALARA.

43 PARTICLE ACCELERATORS↗