Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

FLUID DYNAMICS OF STELLAR JETS IN REAL TIME: THIRD EPOCH HUBBLE SPACE TELESCOPE IMAGES OF HH 1, HH 34, AND HH 47

We present new, third-epoch Hubble Space Telescope H{alpha} and [S II] images of three Herbig-Haro (HH) jets (HH 1 and 2, HH 34, and HH 47) and compare the new images with those from previous epochs. The high spatial resolution, coupled with a time series whose cadence is of order both the hydrodynamic and radiative cooling timescales of the flow, allows us to follow the hydrodynamic/magnetohydrodynamic evolution of an astrophysical plasma system in which ionization and radiative cooling play significant roles. Cooling zones behind the shocks are resolved, so it is possible to identify which way material flows through a given shock wave. The images show that heterogeneity is paramount in these jets, with clumps dominating the morphologies of both bow shocks and their Mach disks. This clumpiness exists on scales smaller than the jet widths and determines the behavior of many of the features in the jets. Evidence also exists for considerable shear as jets interact with their surrounding molecular clouds, and in several cases we observe shock waves as they form and fade where material emerges from the source and as it proceeds along the beam of the jet. Fine structure within two extended bow shocks may result from Mach stems that form at the intersection points of oblique shocks within these clumpy objects. Taken together, these observations represent the most significant foray thus far into the time domain for stellar jets, and comprise one of the richest data sets in existence for comparing the behavior of a complex astrophysical plasma flow with numerical simulations and laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-pointing verification using x-ray pinhole cameras on the 60-beam OMEGA laser

On the OMEGA laser system, the beam-pointing accuracy is verified by irradiating a 4 mm diameter Au-coated spherical target with ~23 kJ of laser energy. Up to ten x-ray pinhole cameras record the x-ray emission from all 60-beam spots. A new set of algorithms has been developed to improve the accuracy of the pointing evaluation. An updated edge-finding procedure allows one to infer the center of the sphere with subpixel accuracy. A new approach was introduced to back-propagate the pixel locations on the 2D image to the 3D surface of the sphere. Furthermore, a fast Fourier transform-based de-noising method significantly improves the signal-to-noise of the data. Based on the beam-pointing analysis, hard-sphere calculations of the laser-drive illumination uniformity on the target surface and the decomposition of the illumination distribution into lower order modes (1–10) are evaluated.

47 OTHER INSTRUMENTATION↗

Bicycle ergometer instrumentation to determine muscle and bone forces during exercise

It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. to use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise (using the bicycle ergometer in this case) so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. The work reported in this document entails a musculoskeletal load measurement system that, when complete, will provide forces at muscle insertion points and other contact points, on bone. This data will be used by Dr. Beth A. Todd, who is also a SSF working with Dr. Shackelford, as input to a finite element model of bone sections to determine stress distributions. A bicycle ergometer has been instrumented to measure parameters needed to determine musculoskeletal forces during exercise. A primary feature of the system is its compactness. It uses small/light sensors without line-of-sight requirements. The system developed includes sensors, signal processing, a data acquisition system, and software to collect the data. The sensors used include optical encoders to measure position and orientation of the pedal (foot), accelerometers to determine kinematic parameters of the shank and thigh, load cells to measure pedal forces on the sagittal plane, and EMG probes to measure muscle activity. The signals are processed using anti-aliasing filters and amplifiers. The sensors' output is digitized using 30 channels of a board mounted inside a 486 class PC. A program sets the data acquisition parameters and collects data during a time period specified by the user. The data is put directly into a file on the hard disk in binary form. The 30 channels are sampled at 200 KHz, and each 30 channel scan is done at a rate of 1000 Hz. The instrumented ergometer has been flown in the KC-135 zero-gravity (zero-g) flight to collect information needed to determine musculoskeletal forces under these conditions. Similar information has been collected in 1-g conditions for comparision with the results from the zero-g case. At this time, the sets of data from both experiments are being processed. An existing methodology will be used to determine the kinematic parameters of the shank and thigh using accelerometer and encoder data. This methodology was developed during the fellow's previous NASA/ASEE fellowship and thanks to a Director's Grant. In the future, a methodology to determine the musculoskeletal forces using Newton's Law of Motion and optimization techniques will be developed to determine forces exerted by particular muscles.

Figueroa, Fernando↗

L1 and L2 Observatories for Earth Science Vision in the Post-2010 Era

NASA's Post-2010 Earth Science Vision is partly built around a new paradigm called the Sensor Web, involving a collaborating set of sensors ranging from deep space, at the L1 and L2 (Lagrange) points, down to the ocean and land surfaces. L1 and L2 observatories, roughly 1.5 million km from Earth towards and away from the Sun, respectively, provide unique vantage points. from L1, the entire sunlit face of the Earth is visible, and from L2, the entire night side. In tandem, they can observe the entire Earth simultaneously, with much less stitching than now needed to patch together the five operational geostationary images. This makes new kinds of science possible, especially science requiring synoptic (simultaneous) observations over the whole globe. Triana, the pioneer of these kinds of observatories, is currently waiting for a launch opportunity. We will describe the novel features of the Triana mission, and of the L1 and L2 vantage points, with examples of the kinds of science that can be done from these points and examples of the way in which Earth observation from such great distances is pushing instrument technology.

Wiscombe, Warren↗

Enhanced Uranium Ore Concentrate Analysis by Handheld Raman Sensor: FY15 Status Report

High-purity uranium ore concentrates (UOC) represent a potential proliferation concern. A cost-effective, “point and shoot” in-field analysis capability to identify ore types, phases of materials present, and impurities, as well as estimate the overall purity would be prudent. Handheld, Raman-based sensor systems are capable of identifying chemical properties of liquid and solid materials. While handheld Raman systems have been extensively applied to many other applications, they have not been broadly studied for application to UOC, nor have they been optimized for this class of chemical compounds. PNNL was tasked in Fiscal Year 2015 by the Office of International Safeguards (NA-241) to explore the use of Raman for UOC analysis and characterization. This report summarizes the activities in FY15 related to this project. The following tasks were included: creation of an expanded library of Raman spectra of a UOC sample set, creation of optimal chemometric analysis methods to classify UOC samples by their type and level of impurities, and exploration of the various Raman wavelengths to identify the ideal instrument settings for UOC sample interrogation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CATHARE calculations of Phenix ultimate natural convection test

The Phenix Sodium cooled Fast Reactor (SFR) started operation in 1973 and it was stopped in 2009. Before the reactor was definitively shutdown, in order to collect experimental data for code assessments in the frame of Generation IV an intensive program of ultimate tests was set up. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip on one secondary pump and a natural convection test in the primary circuit. The natural convection test has been used for an international benchmark on system codes in the frame of the IAEA. The CATHARE code - initially developed for water cooled reactors and now extended for safety analyses for other kinds of reactors, including Sodium Fast Reactor - was used by CEA for this benchmark. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. Main test results are also briefly reminded including the evolution of the core and the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The main developments to perform CATHARE SFR computations and the strategy of system code assessment are presented. Then the CATHARE modelling of Phenix reactor is depicted and the various assumptions are pointed out. CATHARE encountered no problem to predict the initial nominal state. Afterwards, the whole transient scenario is calculated and CATHARE calculations are compared to the Phenix measurements. The global trend is rather well predicted by the CATHARE code. Nevertheless, due to complex flow phenomena occurring in large plena and components, the system code encountered physical limitations, leading to remaining discrepancies between code prediction and plant data. Various sensitivity calculations are presented and they bring partial answers. Additional analyses are in progress to understand more deeply the complex 3D phenomena involved during the different phases of the natural convection test. Additional work for coupling CATHARE system code and TRIO-U CFD code is in progress and will bring useful information to better understand the physical phenomena involved during the natural convection test and to improve system modeling for future SFR safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flight Avionics Hardware Roadmap

The Avionics Technology Roadmap takes an 80% approach to technology investment in spacecraft avionics. It delineates a suite of technologies covering foundational, component, and subsystem-levels, which directly support 80% of future NASA space mission needs. The roadmap eschews high cost, limited utility technologies in favor of lower cost, and broadly applicable technologies with high return on investment. The roadmap is also phased to support future NASA mission needs and desires, with a view towards creating an optimized investment portfolio that matures specific, high impact technologies on a schedule that matches optimum insertion points of these technologies into NASA missions. The roadmap looks out over 15+ years and covers some 114 technologies, 58 of which are targeted for TRL6 within 5 years, with 23 additional technologies to be at TRL6 by 2020. Of that number, only a few are recommended for near term investment: 1. Rad Hard High Performance Computing 2. Extreme temperature capable electronics and packaging 3. RFID/SAW-based spacecraft sensors and instruments 4. Lightweight, low power 2D displays suitable for crewed missions 5. Radiation tolerant Graphics Processing Unit to drive crew displays 6. Distributed/reconfigurable, extreme temperature and radiation tolerant, spacecraft sensor controller and sensor modules 7. Spacecraft to spacecraft, long link data communication protocols 8. High performance and extreme temperature capable C&DH subsystem In addition, the roadmap team recommends several other activities that it believes are necessary to advance avionics technology across NASA: center dot Engage the OCT roadmap teams to coordinate avionics technology advances and infusion into these roadmaps and their mission set center dot Charter a team to develop a set of use cases for future avionics capabilities in order to decouple this roadmap from specific missions center dot Partner with the Software Steering Committee to coordinate computing hardware and software technology roadmaps and investment recommendations center dot Continue monitoring foundational technologies upon which future avionics technologies will be dependent, e.g., RHBD and COTS semiconductor technologies

Some, Raphael↗

Dynamic model-based sensor network design algorithm for system efficiency maximization

Here, a dynamic model-based sensor network design (DMSND) algorithm has been developed for maximizing system efficiency for an estimator-based control system. The algorithm synthesizes the optimal sensor network in the face of disturbances or set point changes. Computational expense of the large-scale combinatorial optimization problem is significantly reduced by parallel computing and by using combination of three novel strategies: multi-rate sampling frequency, model order reduction, and use of an incumbent solution that enables early termination of evaluation of infeasible sensor sets. The developed algorithm is applied to an acid gas removal unit as part of an integrated gasification combined cycle power plant with carbon capture. Even though there are more than thousand process states and more than hundred candidate sensor locations, the optimal sensor network design problem for maximizing process efficiency could be solved within couple of hours for a given budget.

47 OTHER INSTRUMENTATION↗

In-medium modifications of the {omega} meson

We have investigated the in-medium modifications of {omega} mesons in photoproduction experiments using the Crystal Barrel(CB)/TAPS detector system at the ELSA accelerator facility in Bonn. {omega}-mesons were reconstructed using the {omega}{yields}{pi}{sup 0{gamma}} channel. In a first analysis of the data set on a Nb target, published by D. Trnka et al.. [1], evidence for an in-medium mass shift of the {omega}-meson was deduced from the observed {omega} lineshape. The signal shape is, however, sensitive to the background subtraction and fitting procedure as pointed out in the literature [2, 3]. For this reason a re-analysis of the same data set was initiated with the goal to reduce the background and to deduce the shape and the absolute magnitude of the background directly from the data. Here we present recent results from this re-analysis. The omega signal resulting after background subtraction has been compared to different scenarios of Gi-BUU transport model calculations for the full incident photon energy range (900-2200 MeV) and near the production threshold (900-1400 MeV).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved calibration technique of the infrared imaging bolometer using ultraviolet light-emitting diodes

The technique used until recently utilizing the Ne-He laser for imaging bolometer foils calibration [B. J. Peterson et al., J. Plasma Fusion Res. 2, S1018 (2007)] has showed several issues. The method was based on irradiation of 1 cm spaced set of points on a foil by the laser beam moved by set of mirrors. Issues were the nonuniformity of laser power due to the vacuum window transmission nonuniformity and high reflection coefficient for the laser. Also, due to the limited infrared (IR) window size, it was very time consuming. The new methodology uses a compact ultraviolet (uv) light-emitting diodes installed inside the vacuum chamber in a fixed position and the foil itself will be moved in the XY directions by two vacuum feedthroughs. These will help to avoid the above mentioned issues due to lack of a vacuum window, fixed emitters, higher uv power absorption, and a fixed IR camera position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

Application of Fireworks Algorithm in Gamma-Ray Spectrum Fitting for Radioisotope Identification

We present that identification of radioisotopic signature patterns in gamma-ray spectra is of paramount importance in various applications of gamma spectroscopy. Therefore, there are several active research efforts to develop accurate and precise methods to perform automated spectroscopic analysis and subsequently recognize gamma-ray signatures. In this work, the authors present a new method for radioisotope identification in gamma-ray spectra obtained with a low resolution radiation detector. The method fits the obtained spectrum with a linear combina-tion of known template signature patterns. Coefficients of the linear combination are evaluated by computing the solution of a single objective optimization problem, whose objective is the Theil-1 inequality coefficient. Optimization of the problem is performed by the Fireworks Algorithm, which identifies a set of coefficients that minimize the Theil-1 value. The computed coefficients are statistically tested for being significantly different than zero or not, and if at least one is found to be zero then the Fireworks Algorithm is used to reiterate fitting using the non-zero templates. Fitting iterations are continued up to the point that no linear coefficients are found to be zero. The output of the method is a list that contains the radioisotopes that have been identified in the measured spectrum. The method is tested on a set of both simulated and real experimental gamma-ray spectra comprised of a variety of isotopes, and compared to a multiple linear regression fitting, and genetic algorithm Theil-1 based fitting. Finally, results demonstrate the potentiality of the Fireworks Algorithm based method, expressed as higher accuracy and similar precision over the other two tested methodologies for radioisotope signature pattern identification in the framework of gamma-ray spectrum fitting.

Theil Coefficient↗

Portable laser-heating stand for synchrotron applications

A compact, double-sided laser-heating system for diamond-cell synchrotron applications is described. The optical table, containing laser, spectrometer, and all optics for visual observation and measuring temperatures and pressures has an area of less than (1/2) m{sup 2} and weighs less than 20 kg. All components can be remotely controlled at micron levels with simple dc motors and pneumatic drives. The design allows quick alignment of the laser-heated hot spot with the x-ray beam and the spectrometer. The prealigned system can be set up at most synchrotron beamlines within about 1 h. We carried out measurements on a variety of materials above one megabar and up to over 4000 K at both the x-ray diffraction beamline ID 27 and the x-ray absorption beamline ID 24 at the European Synchrotron Facility. A new measurement of the melting temperature of iron by x-ray absorption spectroscopy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster Presentation: Optical Test of NGST Developmental Mirrors

An Optical Testing System (OTS) has been developed to measure the figure and radius of curvature of NGST developmental mirrors in the vacuum, cryogenic environment of the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The OTS consists of a WaveScope Shack-Hartmann sensor from Adaptive Optics Associates as the main instrument, a Point Diffraction Interferometer (PDI), a Point Spread Function (PSF) imager, an alignment system, a Leica Disto Pro distance measurement instrument, and a laser source palette (632.8 nm wavelength) that is fiber-coupled to the sensor instruments. All of the instruments except the laser source palette are located on a single breadboard known as the Wavefront Sensor Pallet (WSP). The WSP is located on top of a 5-DOF motion system located at the center of curvature of the test mirror. Two PC's are used to control the OTS. The error in the figure measurement is dominated by the WaveScope's measurement error. An analysis using the absolute wavefront gradient error of 1/50 wave P-V (at 0.6328 microns) provided by the manufacturer leads to a total surface figure measurement error of approximately 1/100 wave rms. This easily meets the requirement of 1/10 wave P-V. The error in radius of curvature is dominated by the Leica's absolute measurement error of VI.5 mm and the focus setting error of Vi.4 mm, giving an overall error of V2 mm. The OTS is currently being used to test the NGST Mirror System Demonstrators (NMSD's) and the Subscale Beryllium Mirror Demonstrator (SBNM).

Hadaway, James B.↗

Loss-tolerant quantum secure positioning with weak laser sources

Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit. Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.

47 OTHER INSTRUMENTATION↗

Optical interferometers for tests of relativistic gravity in space

A space-based astrometric interferometer with a large optical bandwidth is considered. POINTS (Precision Optical INTerferometry in Space) would measure the angular separation of two stars separated by about 90 deg on the sky with a nominal measurement error of 5 microarcseconds (mas). For a pair of mag 10 stars, the observation would require about 10 minutes. It is estimated that the instrument would measure daily the separation of two stars for each of about 60 pairs of stars; a random sequence of such measurements, if suitably redundant, contains the closure information necessary to detect and correct time dependent measurement biases to well below the nominal measurement accuracy. The 90 deg target separation permits absolute parallax measurements in all directions. A redundant observing schedule for 300 stars and 5 quasars would provide extra redundancy to compensate for the quasars' higher magnitude. If a nominal 30-day observation sequence were repeated 4 times per year for 10 years, stellar parameter uncertainties would be obtained of: 0.6 mas, position; 0.4 mas/y, proper motion; and 0.4 mas, parallax. This set of well-observed stars and quasars would form a rigid frame and the stars would serve as reference objects for measurements of all additional targets, as well as being targets of direct scientific interest. The instrument global data analysis since objectives are considered including a relativity test and technology.

Reasenberg, R. D.↗

An empirical model of diagnostic x-ray attenuation under narrow-beam geometry

Purpose: The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. Methods: An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semilogarithmic (exponential) and linear interpolation]. Results: The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R{sup 2} > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. Conclusions: The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Adaptable, Portable Microarray Reader for Biodetection

We have developed an inexpensive portable microarray reader that can be applied to standard microscope slide-based arrays and other array formats printed on chemically modified surfaces. Measuring only 19 cm in length, the imaging device is portable and may be applicable to both triage and clinical settings. For multiplexing and adaptability purposes, it can be modified to work with multiple excitation/emission wavelengths. Our device is shown to be comparable to a commercial laser scanner when detecting both streptavidin-biotin and antibody interactions. This paper presents the development and characterization of a handheld microarray imager and directly compares it with a commercial scanner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗