Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Rapid Automated Annotation and Analysis of N-Glycan Mass Spectrometry Imaging Data Sets Using NGlycDB in METASPACE

Imaging N-glycan spatial distribution in tissues using mass spectrometry imaging (MSI) is emerging as a promising tool in biological and clinical applications. However, there is currently no high throughput tool for visualization and molecular annotation of N-glycans in MSI data, which significantly slows down data processing and hampers the applicability of this approach. In this work, we present how METASPACE, an open-source cloud engine for molecular annotation of MSI data, can be used to automatically annotate, visualize, analyze, and interpret high-resolution mass spectrometry-based spatial N-glycomics data. METASPACE is an emerging tool in spatial metabolomics, but the lack of compatible glycan databases has limited its application for comprehensive N-glycan annotations from MSI datasets. We created NGlycDB, a public database of N-glycans, by adapting available glycan databases. We demonstrate the applicability of NGlycDB in METASPACE by analyzing MALDI-MSI data from formalin-fixed paraffin-embedded (FFPE) human kidney and mouse lung tissue sections. We added NGlycDB to METASPACE for public use, thus facilitating applications of MSI in glycobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System-Independent X-Ray Characterization

We have developed a method for image reconstruction and analysis of dual-energy X-ray scans that has been demonstrated to yield a physically intuitive characterization of materials (by electron density and effective atomic number) in a system-independent way. Our methodology stands in contrast to common practice of reconstructing images to yield linear attenuation coefficients, which depend strongly on system spectral response. At the core of our method, a technique called dual-energy decomposition is used to generate spectral energy-independent characterizations of the attenuation properties of a material. Inputs to this decomposition include system spectral response estimates and dual-energy X-ray projection data. X-ray cross-section tables are used to convert decomposition results to physical feature estimates (electron density, effective atomic number). Our method currently works best for materials with atomic numbers below 22 (titanium). In prior work for DHS, we demonstrated in a controlled, no-clutter environment that the decomposition technique could be applied to scans of a well-characterized materials on multiple systems with different X-ray spectral responses. In cases where LAC values showed a standard deviation of as much as 20% of mean value, application of our method yielded results with standard deviations as low as 1–3% of mean value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

Electroluminescence Analysis and Grading of Hail Damaged Solar Panels

We analyzed more than 4000 electroluminescence images of hail damaged solar panels from a cluster of houses in Texas. We enhanced the images for ease of analysis and classified the defects within each solar cell into categories of glass breakage, installer damage, inactive substrings, crack severity, interconnect wire problems, and whether the damage was likely caused by hail. From these statistics, we quantified each panel into five levels of hail damage for insurance claims, and four levels of overall quality for potential resale pricing. Here, we share here some statistics regarding the defects with the hope that the data is useful to others attempting to predict the invisible damage to systems based just on the easily observable glass breakage statistics.

14 SOLAR ENERGY↗

Diagnostic diagrams for ram pressure stripped candidates

ABSTRACT This paper presents a method for finding ram pressure stripped (RPS) galaxy candidates by performing a morphological analysis of galaxy images obtained from the Legacy survey. We consider a sample of about 600 galaxies located in different environments such as groups and clusters, tidally interacting pairs and the field. The sample includes 160 RPS previously classified in the literature into classes from J1 to J5, based on the increasing level of disturbances. Our morphological analysis was done using the astromorphlib software followed by the inspection of diagnostic diagrams involving combinations of different parameters like the asymmetry (A), concentration (C), Sérsic index (n), and bulge strength parameters $F(G,\, M_{20})$. We found that some of those diagrams display a distinct region in which galaxies classified as J3, J4, and J5 decouples from isolated galaxies. We call this region as the morphological transition zone and we also found that tidally interacting galaxies in pairs are predominant within this zone. Nevertheless, after visually inspecting the objects in the morphological transition zone to discard obvious contaminants, we ended up with 33 bona fide new RPS candidates in the studied nearby groups and clusters (Hydra, Fornax, and CLoGS sample), of which one-third show clear evidence of unwinding arms. Future works may potentially further increase significantly the samples of known RPS using such method.

Astronomy & Astrophysics↗

Temperature Effects on Droplet Oscillation Decay with Application to Fuel Property Measurement

Observation of oscillation decay in droplets has been shown to be an effective approach in determining physical properties such as viscosity and surface tension for emerging biofuels using μl quantities. Herein this work extends the approach to higher temperatures relevant to fuel injection conditions for internal combustion engines. Experiments are conducted that use high-resolution strobed imaging of moving, heated, μm-sized, fuel droplets to capture shape oscillation decay through image processing and analysis. Two fuels are investigated, iso-butanol and a primary reference fuel (PRF 84), which is a mixture of iso-octane and n-heptane. A piezoelectric droplet generator is used to generate a continuous train of single droplets, which are given an initial perturbation and subsequently undergo damped oscillations, captured using strobed imaging. Surface tension and viscosity calculated at four different temperatures ranging from 30°C-55°C using the frequency and decay time associated with the fundamental mode are found to be within ~ 10% of reference values obtained from the literature. Complementary numerical simulations are performed that utilize a volume-of-fluid approach to track transient droplet oscillation phenomena along with heat and mass transfer in a 2D axisymmetric domain. Simulations, where droplet size and temperature can be independently varied, capture an expected decrease in oscillation frequency and increase in decay time, with increase in fuel temperature. The simulations are further used to study the relative contribution to deviations in surface tension and viscosity predictions due to heat and mass transfer from the droplet, as well as viscous effects violating the inviscid flow assumption in the droplet oscillation theory. Mass loss effects are found to be negligible. Temperature change due to heat transfer is found to have the next highest sensitivity, particularly for the more volatile PRF 84, which has a lower viscosity and associated Ohnesorge number. For isobutanol, which has a higher viscosity and Ohnesorge number, viscous effects contribute the most to deviation in fuel property predictions.

09 BIOMASS FUELS↗

Atomic Force Microscopy to Characterize Antimicrobial Peptide-Induced Defects in Model Supported Lipid Bilayers

Antimicrobial peptides (AMPs) interact with bacterial cell membranes through a variety of mechanisms, causing changes extending from nanopore formation to microscale membrane lysis, eventually leading to cell death. Several AMPs also disrupt mammalian cell membranes, despite their significantly different lipid composition and such collateral hemolytic damage hinders the potential therapeutic applicability of the AMP as an anti-microbial. Elucidating the mechanisms underlying the AMP–membrane interactions is challenging due to the variations in the chemical and structural features of the AMPs, the complex compositional variations of cell membranes and the inadequacy of any single experimental technique to comprehensively probe them. (1) Background: Atomic Force Microscopy (AFM) imaging can be used in combination with other techniques to help understand how AMPs alter the orientation and structural organization of the molecules within cell membranes exposed to AMPs. The structure, size, net charge, hydrophobicity and amphipathicity of the AMPs affect how they interact with cell membranes of differing lipid compositions. (2) Methods: Our study examined two different types of AMPs, a 20-amino acid, neutral, α-helical (amphipathic) peptide, alamethicin, and a 13-amino acid, non-α-helical cationic peptide, indolicidin (which intramolecularly folds, creating a hydrophobic core), for their interactions with supported lipid bilayers (SLBs). Robust SLB model membranes on quartz supports, incorporating predominantly anionic lipids representative of bacterial cells, are currently not available and remain to be developed. Therefore, the SLBs of zwitterionic egg phosphatidylcholine (PC), which represents the composition of a mammalian cell membrane, was utilized as the model membrane. This also allows for a comparison with the results obtained from the Quartz Crystal Microbalance with Dissipation (QCM-D) experiments conducted for these peptides interacting with the same zwitterionic SLBs. Further, in the case of alamethicin, because of its neutrality, the lipid charge may be less relevant for understanding its membrane interactions. (3) Results: Using AFM imaging and roughness analysis, we found that alamethicin produced large, unstable defects in the membrane at 5 µM concentrations, and completely removed the bilayer at 10 µM. Indolicidin produced smaller holes in the bilayer at 5 and 10 µM, although they were able to fill in over time. The root-mean-square (RMS) roughness values for the images showed that the surface roughness caused by visible defects peaked after peptide injection and gradually decreased over time. (4) Conclusions: AFM is useful for helping to uncover the dynamic interactions between different AMPs and cell membranes, which can facilitate the selection and design of more efficient AMPs for use in therapeutics and antimicrobial applications.

Swana, Kathleen W.↗

Enhance Low Level Temperature and Moisture Profiles Through Combining NUCAPS, ABI Observations, and RTMA Analysis

Thermodynamic information from low levels in the atmosphere is crucial for operational weather forecasts and meteorological researchers. The NOAA Unique Combined Atmospheric Processing System (NUCAPS) sounding products have been proven beneficial to fill the data gap between synoptic radiosonde observations (RAOBs). However, compared with the upper troposphere, the accuracy of NUCAPS soundings in the low levels still needs improvement. In this study, a deep neural network (DNN) is applied to fuse multiple data sources to enhance the NUCAPS temperature and moisture profiles in the lower atmosphere. The network is developed by combining satellite observations, including NUCAPS sounding retrievals and high resolution geostationary satellite observations from the Advanced Baseline Imager, and surface analysis from the Real-Time Mesoscale Analysis (RTMA) as inputs, while collocated soundings from ECMWF re-analysis version 5 are used as the benchmark for the training. The performance of the model is evaluated by using the independent testing data set, data from a different year, as well as collocated RAOBs, showing improvement to the temperature and moisture profiles by reducing the root-mean-squared-error (RMSE) by more than 30% in the lower atmosphere (from 700 hPa to surface) in both clear sky and partially cloudy conditions. A convective event from June 18, 2017 is presented to illustrate the application of the enhanced low level soundings on high impact weather events. The enhanced soundings from fused data capture the large surface-based convective available potential energy structures in the preconvection environment, which is very useful for severe storm nowcasting and forecasting applications.

54 ENVIRONMENTAL SCIENCES↗

A Generative Model for Realistic Galaxy Cluster X-Ray Morphologies

Abstract The X-ray morphologies of clusters of galaxies display significant variations, reflecting their dynamical histories and the nonlinear dependence of X-ray emissivity on the density of the intracluster gas. Qualitative and quantitative assessments of X-ray morphology have long been considered a proxy for determining whether clusters are dynamically active or “relaxed.” Conversely, the use of circularly or elliptically symmetric models for cluster emission can be complicated by the variety of complex features realized in nature, spanning scales from megaparsecs down to the resolution limit of current X-ray observatories. In this work, we use mock X-ray images from simulated clusters from The Three Hundred project to define a basis set of cluster image features. We take advantage of the clusters’ approximate self-similarity to minimize the differences between images before encoding the remaining diversity through a distribution of high-order polynomial coefficients. Principal component analysis then provides an orthogonal basis for this distribution, corresponding to natural perturbations from an average model. This representation allows novel, realistically complex X-ray cluster images to be easily generated, and we provide code to do so. The approach provides a simple way to generate training data for cluster image analysis algorithms and could be straightforwardly adapted to generate clusters displaying specific types of features or selected by physical characteristics available in the original simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

A Uniform Analysis of Debris Disks with the Gemini Planet Imager. I. An Empirical Search for Perturbations from Planetary Companions in Polarized Light Images

The Gemini Planet Imager (GPI) has excelled in imaging debris disks in the near-infrared. The GPI Exoplanet Survey imaged 24 debris disks in polarized H-band light, while other programs observed half of these disks in polarized J and/or K1 bands. Using these data, we present a uniform analysis of the morphology of each disk to find asymmetries suggestive of perturbations, particularly those due to planet–disk interactions. The multiwavelength surface brightness, disk color, and geometry permit the identification of any asymmetries such as warps or disk offsets from the central star. We find that 19 of the disks in this sample exhibit asymmetries in surface brightness, disk color, disk geometry, or a combination of the three, suggesting that for this sample, perturbations, as seen in scattered light, are common. The relationship between these perturbations and potential planets in the system is discussed. We also explore correlations among stellar temperatures, ages, disk properties, and observed perturbations. We find significant trends between the vertical aspect ratio and the stellar temperature, disk radial extent, and the dust grain size distribution power law, q. We also confirm a trend between the disk color and stellar effective temperature, where the disk becomes increasingly red/neutral with increasing temperature. Such results have important implications for the evolution of debris disk systems around stars of various spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Gemini Planet Imager Exoplanet Survey: Dynamical Mass of the Exoplanet β Pictoris b from Combined Direct Imaging and Astrometry

Herein, we present new observations of the planet β Pictoris b from 2018 with the Gemini Planet Imager (GPI), the first GPI observations following conjunction. Based on these new measurements, we perform a joint orbit fit to the available relative astrometry from ground-based imaging, the Hipparcos Intermediate Astrometric Data (IAD), and the Gaia DR2 position, and demonstrate how to incorporate the IAD into direct imaging orbit fits. We find a mass consistent with predictions of hot-start evolutionary models and previous works following similar methods, though with larger uncertainties: $12.8^{+5.3}_{–3.2} M_{Jup}$. Our eccentricity determination of ${0.12}_{-0.03}^{+0.04}$ disfavors circular orbits. We consider orbit fits to several different imaging data sets, and find generally similar posteriors on the mass for each combination of imaging data. Our analysis underscores the importance of performing joint fits to the absolute and relative astrometry simultaneously, given the strong covariance between orbital elements. Time of conjunction is well-constrained within 2.8 days of 2017 September 13, with the star behind the planet's Hill sphere between 2017 April 11 and 2018 February 16 (±18 days). Following the recent radial velocity detection of a second planet in the system, β Pic c, we perform additional two-planet fits combining relative astrometry, absolute astrometry, and stellar radial velocities. These joint fits find a significantly smaller mass (8.0 ± 2.6 M Jup) for the imaged planet β Pic b, in a somewhat more circular orbit. We expect future ground-based observations to further constrain the visual orbit and mass of the planet in advance of the release of Gaia DR4.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manifold projection image segmentation for nano-XANES imaging

As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nanoscale x-ray absorption near edge structure (XANES) imaging, where XANES spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used principal component analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as x-ray fluorescence data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including scanning transmission x-ray microscopy, where the length scale of domains is larger than the resolution of the experiment.

36 MATERIALS SCIENCE↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗