Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Magnetized liner inertial fusion platform development to assess performance scaling with drive parameters

Magnetized liner inertial fusion (MagLIF) experiments have demonstrated fusion-relevant ion temperatures up to 3.1 keV and thermonuclear production of up to 1.1 × 1013 deuterium–deuterium neutrons. This performance was enabled through platform development that provided increases in applied magnetic field, coupled preheat energy, and drive current. Advanced coil designs with internal reinforcement enabled an increase from 10 to 20 T. An improved laser pulse shape, beam smoothing, and thinner laser entrance foils increased preheat energy coupling from less than 1 to 2.3 kJ. A redesign of the final transmission line and load region increased peak load current from 16 to 20 MA. The wider range of input parameters was leveraged to study target performance trends with preheat energy, applied magnetic field, and peak load current. Ion temperature and neutron yield generally followed trends in two-dimensional clean Lasnex calculations. Stagnation performance improved with peak load current when other input parameters were also increased such that convergence was maintained. This dataset suggests that reducing convergence to less than 30 would improve predictability of target performance. Lasnex was used to identify a simulation-optimized scaling path, which suggests 10+ kJ of fusion yield is possible on the Z facility with achievable input parameters. This path also indicates >10 MJ could be generated through volume burn on a future facility with a path to high yield (>200 MJ) using cryogenic dense fuel layers. The newly developed MagLIF platform enables exploration of both this simulation optimized scaling path and a recently developed similarity-scaling path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of pulsed mode operation with the frequency tuned CAPRICE ECRIS

In order to increase the intensity of the highly charged ions produced by the Electron Cyclotron Resonance Ion Sources (ECRISs), techniques like the frequency tuning and the afterglow mode have been developed and in this paper the effect on the ion production is shown for the first time when combining both techniques. Recent experimental results proved that the tuning of the operating frequency of the ECRIS is a promising technique to achieve higher ion currents of higher charge states. On the other hand, it is well known that the afterglow mode of the ECRIS operation can provide more intense pulsed ion beams in comparison with the continuous wave (cw) operation. These two techniques can be combined by pulsing the variable frequency signal driving the traveling wave tube amplifier which provides the high microwave power to the ECRIS. In order to analyze the effect of these two combined techniques on the ion source performance, several experiments were carried out on the pulsed frequency tuned CAPRICE (Compacte source A Plusiers Résonances Ionisantes Cyclotron Electroniques)-type ECRIS. Different waveforms and pulse lengths have been investigated under different settings of the ion source. The results of the pulsed mode have been compared with those of cw operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of plasma characteristics in an unbalanced magnetron sputtering system

Results are presented from experimental studies of a magnetron sputtering system for different configurations of the magnetic field above the cathode surface. The current-voltage characteristics of a magnetron discharge at different working gas pressures (0.08-0.3 Pa) and currents in the unbalancing coil were studied. The production and transport of charge carriers in a magnetron discharge with an unbalanced magnetic field was investigated by means of probe measurements of plasma characteristics and ion energies in the region between the substrate and the magnetic trap at the cathode surface. The radial distributions of the ion current density, plasma potential, and floating potential in the unbalanced operating mode are found to have pronounced extrema at the magnetron axis. It is shown that the plasma density near the substrate can be increased considerably when the axial magnetic field is high enough to efficiently confine plasma electrons and prevent their escape to the chamber wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regularities of Plasma-Immersion Formation of Long-Pulse High-Intensity Titanium Ion Beams

The results of experimental investigations on plasma-immersion formation of ballistically focused beams of low-energy titanium ions with the pulse duration up to 30 μs are presented. The processes of neutralization of the space charge of high-intensity beams upon increasing the ion-current density by a few orders of magnitude during their focusing are addressed. The conditions of preliminary injection of the metal plasma, its parameters, the formation of the beam plasma during residual-gas ionization and secondary and thermionic emissions are shown to be of critical importance for an effective transport of these beams in the equi-potential drift space. It is demonstrated that the use of a disc electrode, preventing the macroparticles from penetrating the region of the ballistic beam focusing, increases the efficiency of long-pulse titanium ion beam transport and simultaneously reduces the probability of instability development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linac4 H{sup −} ion sources

CERN’s 160 MeV H{sup −} linear accelerator (Linac4) is a key constituent of the injector chain upgrade of the Large Hadron Collider that is being installed and commissioned. A cesiated surface ion source prototype is being tested and has delivered a beam intensity of 45 mA within an emittance of 0.3 π ⋅ mm ⋅ mrad. The optimum ratio of the co-extracted electron- to ion-current is below 1 and the best production efficiency, defined as the ratio of the beam current to the 2 MHz RF-power transmitted to the plasma, reached 1.1 mA/kW. The H{sup −} source prototype and the first tests of the new ion source optics, electron-dump, and front end developed to minimize the beam emittance are presented. A temperature regulated magnetron H{sup −} source developed by the Brookhaven National Laboratory was built at CERN. The first tests of the magnetron operated at 0.8 Hz repetition rate are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Clouds and Snowplows: Bulk Plasma Escape from Mars Observed by MAVEN

We present initial Mars Atmosphere and Volatile EvolutioN (MAVEN) observations and preliminary interpretation of bulk plasma loss from Mars. MAVEN particle and field measurements show that planetary heavy ions derived from the Martian atmosphere can escape in the form of discrete coherent structures or "clouds." The ions in these clouds are unmagnetized or weakly magnetized, have velocities well above the escape speed, and lie directly downstream from magnetic field amplifications, suggesting a "snowplow" effect. This postulated escape process, similar to that successfully used to explain the dynamics of active gas releases in the solar wind and terrestrial magnetosheath, relies on momentum transfer from the shocked solar wind protons to the planetary heavy ions, with the electrons and magnetic field acting as intermediaries. Fluxes of planetary ions on the order of 10(exp 7)/sq cm/s can escape by this process, and if it operates regularly, it could contribute 10-20% of the current ion escape from Mars.

Halekas, J. S.↗

Growth study of ion assisted evaporated molybdenum thin films

We reported optimization of ion-to-atom ratios and ion energy for growth of molybdenum thin film on oxidized silicon substrate using ion assisted electron beam evaporation system. The ion-to-atom ratio is varied by independently adjusting the ion current density and deposition rate. The structural characterization of the films is carried out by hard X-ray reflectivity. We observed improvement in film density from 85.5% to 98.2% and film roughness from {approx}2 nm to 0.84nm on {approx}26 nm thick Mo film by optimizing ion parameters. The observed results are discussed considering the effect of kinetic of adatoms during growth of film.

36 MATERIALS SCIENCE↗

Some aspects of ion sheath dynamics under the action of pulsed voltage

The time evolution of an unsteady cathode ion sheath in plasma has been studied numerically. The calculations demonstrate the presence of spikes in the ion current density and electric field strength at the cathode. The amplitudes of these spikes significantly exceeds the steady-state level, which agrees with data from other studies. Approximate formulas are derived that describe the spike amplitudes as functions of the rise time and amplitude of the applied voltage pulse, the mass and charge of ions, and the density and temperature of plasma electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The dynamic cusp

Results of a study of satellite and ground-based data acquired near the dayside cusp during a period when the IMF was inferred to have a strong northward component are presented. The presence of Pc 1 bursts, Pc 4-5 pulsations, and a tailward traveling twin vortex pattern of ionospheric convection suggests that the magnetosphere may have been temporarily compressed. Magnetic field data acquired at a synchronous altitude from GOES 5 and on the ground from Huanacayo support this suggestion. Plasma with ion dispersion characteristics associated with a cusp during southward IMF was detected by Viking over a 3.5-deg range of latitude. The presence of standing Alfven waves and ring current ions suggests that this 'cusplike' plasma was observed on closed geomagnetic field lines. It is suggested that the magnetosphere, during a northward IMF, is temporarily compressed by a solar wind pressure enhancement that produces the Pc 1 bursts, Pc 4-5 pulsations, and ionospheric vortices.

Potemra, T. A.↗

Radiographic Technique for Densitometric Studies Using Heavy Ion Microbeams

Different analytical techniques are typically used to perform multi-elemental and densitometric analysis by means of particle beams with micrometric space resolution. Usually, those analyses are respectively performed by PIXE and STIM. Traditionally, to characterize the trace element concentrations in a specimen two different experiments are required with differences in setups and types of detectors employed, as well as in the necessary ion current intensities. In this work, we discuss the latest results in the development of a new technique that synthesizes both analyses in just a single one, by means of heavy ion induced x-ray emission. This technique, implemented for the first time at the Tandar Laboratory, employs a second target in addition to the sample under study. The multi-elemental information of the specimen is provided by its PIXE signal and its densitometric information is supplied by the PIXE signal of the secondary target, which is placed immediately behind the sample under analysis. These PIXE signals are produced and acquired during the same experiment, allowing the analysis of both features (composition and density) at the same time. The X-rays originated in the secondary target are attenuated when traversing the specimen in the direction of the detector and consequently a radiographic image of the specimen is obtained. In this case, the characteristic X-rays of the secondary target act like a monochromatic secondary source. In the present work, a method to estimate the thickness of specimens is introduced and compared with estimations performed by the STIM method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Proposal for a Novel H{sup -} Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further ''self-extracted'' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

43 PARTICLE ACCELERATORS↗

Extraction of low-energy negative oxygen ions for thin film formation

Coextraction of low-energy positive and negative ions were performed using a plasma sputter-type ion source system driven by a 13.56 MHz radio frequency (rf) power. Titanium (Ti) atoms were sputtered out from a target and the sputtered neutrals were postionized in oxygen/argon (O{sub 2}/Ar) plasma prior to extraction. The negative O ions were surface-produced and self-extracted. Mass spectral analyses of the extracted ion beams revealed the dependence of the ion current on the incident rf power, induced target bias and O{sub 2}/Ar partial pressure ratio. Ti{sup +} current was found to be dependent on Ar{sup +} current and reached a saturation value with increasing O{sub 2} partial pressure while the O{sup -} current showed a peak current at around 1:9 O{sub 2}/Ar partial pressure ratio. Ti{sup +} current was several orders of magnitude higher than that of the O{sup -} current.

36 MATERIALS SCIENCE↗

An Accumulator/Pre-Booster for the Medium-Energy Electron Ion Collider at Jlab

Future nuclear physics facilities such as the proposed electron ion collider (MEIC) will need to achieve record high luminosities in order to maximize discovery potential. Among the necessary ingredients is the ability to generate, accumulate , accelerate, and store high current ion beams from protons to lead ions. One of the main components of this ion accelerator complex for MEIC chain is the accumulator that also doubles as a pre-booster, which takes 200 MeV protons from a superconducting linear accelerator, accumulates on the order of 1A beam, and boosts its energy to 3GeV, before extraction to the next accelerator in the chain, the large booster. This paper describes its design concepts, and summarizes some preliminary results, including linear optics, space charge dynamics, and spin polarization resonance analysis.

43 PARTICLE ACCELERATORS↗

First composition measurement of the bulk of the storm-time ring current (1 to 300 keV/e) with AMPTE-CCE

Measurements of the charge state and elemental compositions as well as differential intensities of ring current ions with energies of 1-315 keV/e, made with the Charge-Energy-Mass Spectrometer on the AMPTE/CCE spacecraft, are reported. An analysis of the data suggests that while the storm-time increases in the number densities of ring current H(+) and He(2+) may be roughly accounted for by the decreased volume of the compressed magnetosphere, the large jumps in the number and energy densities of O(+) require injection of energetic ionospheric ions.

Gloeckler, G.↗

Gas field ion source from an Ir/W<111> single-atom tip

We show that a thermally stable Ir/W<111> single-atom tip is a very good point ion source for rare gases (He, Ar) and reactive gases (H{sub 2}, O{sub 2}). The ion beams are emitted from the topmost atom with a very small opening angle (<1 deg.) and, most importantly, they exhibit high brightness. In addition, the ion currents are very stable. These good properties together with the long lifetime of the tip and the reliable tip preparation method make this tip especially suitable for applications in gas field ion source focused ion beam systems.

43 PARTICLE ACCELERATORS↗

Measurements of recombination of electrons with H3O(plus)-(H2O)n series ions

Recombination coefficients of electrons with ions of the hydrated hydronium ion series (H3O(+))(H2O)n, where n = 0, 1, 2, 3, 4, 5, 6, were determined with a microwave afterglow/mass spectrometer apparatus. Afterglow measurements of electron density decays in helium-water vapor mixtures are correlated with the decay of mass-identified ion currents to the wall of the microwave cavity. By varying the temperature of the gas and the partial pressure of the water vapor in the mixture, different groups of hydronium series ions are made to dominate the afterglow.

Leu, M. T.↗

Improved analysis techniques for cylindrical and spherical double probes

A versatile double Langmuir probe technique has been developed by incorporating analytical fits to Laframboise's numerical results for ion current collection by biased electrodes of various sizes relative to the local electron Debye length. Application of these fits to the double probe circuit has produced a set of coupled equations that express the potential of each electrode relative to the plasma potential as well as the resulting probe current as a function of applied probe voltage. These equations can be readily solved via standard numerical techniques in order to determine electron temperature and plasma density from probe current and voltage measurements. Because this method self-consistently accounts for the effects of sheath expansion, it can be readily applied to plasmas with a wide range of densities and low ion temperature (T{sub i}/T{sub e} Much-Less-Than 1) without requiring probe dimensions to be asymptotically large or small with respect to the electron Debye length. The presented approach has been successfully applied to experimental measurements obtained in the plume of a low-power Hall thruster, which produced a quasineutral, flowing xenon plasma during operation at 200 W on xenon. The measured plasma densities and electron temperatures were in the range of 1 Multiplication-Sign 10{sup 12}-1 Multiplication-Sign 10{sup 17} m{sup -3} and 0.5-5.0 eV, respectively. The estimated measurement uncertainty is +6%/-34% in density and +/-30% in electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗