Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

Space-Environment Simulation at the Lewis Research Center

A knowledge of the environmental conditions in space and an understanding of the possible effect on objects in that environment is necessary in order to make a full-scale, systematic exploration of outer space. Once these conditions have been determined, the understanding of the behavior of objects in space may be gained by simulating the environment in the laboratory and conducting experiments in the simulated environment. Among the conditions in space which have been determined and may be simulated are the pressure, the temperature, and the radiant energy. Quantitatively, simulating these conditions would require a pressure as low as 10 (exp -16) mm Hg, a sink temperature of approximately 30 to 40 K, and radiation similar to that from a 6,000 K black body. The features of the space environment directly affect the thermal balance of the spacecraft. The temperature of the object is that temperature which provides equilibrium between the energy absorbed by the object and the energy emitted by the object. Hence, a knowledge of the absorption and emission characteristics for materials under space environmental conditions must be obtained. High-speed particles may impact and erode the material surfaces and in that way alter the radiation properties of the materials and finally change the equilibrium temperature. Also, since most of the radiant energy (that from the sun) is from one direction, the-heat-transfer within the body will provide surface-temperature variations which depend upon the shape and orientation of the object and the properties of the material. These variations may be effectively studied in the simulated environment. Finally, because of the vacuum the heat transferred to and from the object must be accomplished solely by radiation. Thus, if heat-cycle power-generation equipment is to be used, the necessary rejection of heat must be accomplished by radiation from waste heat radiators whose design must be investigated in order to determine optimum configurations.

Nichols, Lester D.↗

Thermodynamic Data for Fifty Reference Elements

This report is a compilation of thermodynamic functions of 50 elements in their reference state. The functions are: C(sup 0, sub p), {H(T)-H(sup 0)(0)}, S(sup 0)(T), and - {G(sup 0)(T) - H(sup 0)(0)} for the elements Ag, Al, Ar, B, Ba, Be, Br2, C, Ca, Cd, Cl2, Co, Cr, Cs, Cu, F2, Fe, Ge, H2, He, Hg, I2, K, Kr, Li, Mg, Mn, Mo, N2, Na, Nb, Ne, Ni, O2, P, Pb, Rb, S, Si, Sn, Sr, Th, Th, Ti, U, V, W, Xe, Zn, and Zr. Deuterium D, and electron gas e(sup -) are also included. The data are tabulated as functions of temperature as well as given in the form of least-squares coefficients for two functional forms for C(sup 0, sub p) with integration constants for enthalpy and entropy. One functional form for C(sup 0, sub p) is a fourth-order polynomial and the other has two additional terms, one with T(sup -1) and the other with T(sup -2). The gases Ar, D2, e(sup -), H2, He, Kr, N2, Ne, O2, and Xe are tabulated for temperatures from 100 to 20 000 K. The remaining gases Cl2 and F2 are tabulated from 100 to 6000 K. The polynomial functional form for C(sup 0, sub p) for all these gases is split into two temperature intervals of 200 to 1000 K and 1000 to 6000 K. The second functional form for (sup 0, sub p) has an additional interval from 6000 to 20 000 K for the gases tabulated to 20 000 K. The fits are constrained so that the properties match at the common temperature endpoints. The temperature ranges for the condensed species vary with range of the data, phase changes, and shapes of the C(sup 0, sub p) curves.

McBride, Bonnie J.↗

Structural Fluctuations and Thermophysical Properties of Molten II-VI Compounds

Recently, in support of the microgravity experiment entitled "Crystal Growth of Selected 11-VI Semiconducting Alloys by Directional Solidification," the viscosity of HgZnTe pseudobinary melt was measured using an oscillating-cup viscometer at NASA/Marshall Space Flight Center (MSFC). An unexpected time drift of the measured viscosity, which shows a slow relaxation phenomena at temperatures near the liquidus point, was reproducibly observed. Two sets of data were obtained by cooling the Hg(0.84)Zn(0.16)Te melt from 850 C and stabilizing at temperatures of 790 C, which is just above the liquidus temperature, and stabilizing at temperature of 810 C. While it took one day to reach equilibration at 810 C, five days were required at 790 C A similar relaxation phenomenon was also observed in the measured density of the same liquid. Furthermore, in the density measurements of the HgCdTe melts, which is the pseudobinary system studied in another flight experiment entitled "Growth of Solid Solution Single Crystals," a negative thermal expansion was reported. The liquid density increases from the liquidus point to a maximum value at a temperature approximately 700 C above the liquidus, where normal thermal expansion progressively resumes.

Su, Ching-Hua↗

Centrifugation of Cultured Osteoblasts And Macrophages as a Model To Study How Gravity Regulates The Function of Skeletal Cells

Mechanical loading helps define the architecture of weight-bearing bone via the tightly regulated process of skeletal turnover. Turnover occurs by the concerted activity of osteoblasts, responsible for bone formation. and osteoclasts, responsible for bone resorption. Osteoclasts are specialized megakaryon macrophages, which differentiate from monocytes in response to resorption stimuli, such as reduced weight-bearing. Habitation in space dramatically alters musculoskeletal loading, which modulates both cell function and bone structure. Our long-term objective is to define the molecular and cellular mechanisms that mediate skeletal adaptations to altered gravity environments. Our experimental approach is to apply hypergravity loads by centrifugation to rodents and cultured cells. As a first step, we examined the influence of centrifugation on the structure of cancellous bone in rats to test the ability of hypergravity to change skeletal architecture. Since cancellous bone undergoes rapid turnover we expected the most dramatic structural changes to occur in the shape of trabeculae of weight-bearing, cancellous bone. To define the cellular responses to hypergravity loads, we exposed cultured osteoblasts and macrophages to centrifugation. The intraosseous and intramedullary pressures within long bones in vivo reportedly range from 12-40 mm Hg, which would correspond to 18-59 gravity (g) in our cultures. We assumed that hydrostatic pressure from the medium above the cell layer is at least one major component of the mechanical load generated by centrifuging cultured cells. and therefore we exposed the cells to 10-50g. In osteoblasts, we examined the structure of their actin and microtubule networks, production of prostaglandin E2 (PGE2), and cell survival. Analysis of the shape of the cytoskeletal networks provides evidence for the ability of centrifugation to affect cell structure, while the production of PGE2 serves as a convenient marker for mechanical stimulation. We examined cell survival, reasoning that osteoblasts might mold skeletal structure in a hypergravity environment in part by regulating apoptosis and thus the duration of osteoblast productivity. Finally, we tested the influence of centrifugation on microbial activation of a macrophage cell line (RAW264.7). In response to the appropriate hormonal stimulation, this cell line is reportedly capable of undergoing differentiation to express osteoclast markers. In addition, a component of the cell wall of gram-negative bacteria, lipopolysaccaride (LPS), stimulates the formation of osteoclasts in vivo. Thus we tested the influence on centrifugation on RAW264.7 cells stimulated with LPS to provide an index of the function of osteoclast precursors.

Globus, Ruth K.↗

A Potential Treatment for Post-Flight Orthostatic Intolerance in Aero-Space Crews: Autogenic-Feedback Training

Postflight orthostatic intolerance has been identified as a serious biomedical problem associated with long duration exposure to microgravity in space. High priority has been given to the development of countermeasures for this disorder which are both effective and practical. A considerable body of clinical research has demonstrated that people can be taught to increase their own blood pressure voluntarily and that this is an effective treatment for chronic Orthostatic intolerance in paralyzed patients. The present pilot study was designed to examine the feasibility of adding training in control of blood pressure to an existing preflight training program designed to facilitate astronaut adaptation to microgravity. Using in operant conditioning procedure, Autogenic-Feedback Training (AFT), three men and two women participated in four to nine (15-30 training sessions). At the end of training ranged between 20 and 50 mm Hg under both supine and 450 head-up tilt conditions. These findings suggest that AFT may be a useful alternative treatment or supplement to existing approaches for preventing postflight Orthostatic intolerance. Further, the use of operant conditioning methods for training cardiovascular responses may contribute to the general understanding of the mechanisms of orthostatic intolerance.

Cowings, P. S.↗

Cutaneous Microvascular Flow In the Foot During Simulated Variable Gravities

Our objective was to elucidate how varying gravitational fields affect blood perfusion in the sole of the foot. Human subjects underwent whole-body tilting at four angles: upright (1 G(sub z), 22 deg (.38 G(sub z)), 10 deg (.17 G(sub z)), and supine (0 G(sub z)), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight bearing load was measured beneath the same foot with a calibrated scale. Foot mean arterial pressures (MAP) were calculated by adding estimated hydrostatic pressures to continuously recorded heart-level blood pressures for each subject. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of one kilogram beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load (CL). Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load, OL). CL and OL were normalized to each subject's body weight and expressed as percent of body weight. Mean CLs (SD in parentheses) for simulated Earth, Mars, Moon, and micro-gravities were 14 (5), 8 (2), 6 (2), and 5 (2) percent of body weight, respectively. OLs were 12 (3), 6 (1), 5 (2), and 4 (1), respectively. Calculated foot MAPs for each simulated gravitational field were 192 (19), 127 (12), 106 (10), and 87 (9) mm Hg, respectively. CL and OL were significantly correlated with foot MAP (r = 0.70, 0.72, respectively). Overall, CL and OL were significantly different (p is less than 0.001). The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischernia during loading in microgravity than on Earth.

Chang, David S.↗

The NASA Ames Closed Environmental Research Chamber: Present Status

The Closed Environmental Research Chamber (CERC) at the NASA Ames Research Center was created to investigate both components and complete systems for life support of advanced space exploration missions. This facility includes a Main Chamber, an Airlock, a Sample Transfer Lock, a Vacuum System, an Air Recompression System, a dedicated control room and a pit area for housing supporting and environmental control systems. The Main Chamber provides 310 sq ft of internal working/living space on two levels. It is planned that the CERC will be a human-rated facility for habitation simulation under mass balance closure conditions. The internal pressure will be variable over the range of 14.7 psia to 5 psia with accompanying capability for variation in atmosphere composition to maintain the oxygen partial pressure at 160 mm Hg. The CERC will be provided with a core set of primary life support subsystems for temperature and humidity control, C02 removal and trace contaminant control. Interfacing with external life support technology test b~ds with be provided, along with connection to centralized, microprocessor-based data acquisition and control systems. This paper will discuss the current status of the CERC facility and show how it is being used to address the advanced technology requirements necessary to implement an integrated working and living environment for a planetary habitat. In particular, it will be shown how the CERC, along with a human-powered centrifuge, a planetary terrain simulator and advanced displays and a virtual reality capability will work together to develop and demonstration applicable technologies for future planetary habitats. Artificial intelligence and expert system programming techniques will be used extensively to provide an automated environment for a 4-person crew. There will be several robotic mechanisms performing exploration tasks external to the habitat that will be controlled through the virtual environment to provide representative workloads for the crew. Finally, there will be a discussion of how effective are innovative new multidisciplinary test facilities to the investigation of the wide range of human and machine problems inherent in exploration missions.

Gross, Anthony R.↗

Beer Law Constants and Vapor Pressures of HgI2 over HgI2(s,l)

The optical absorption spectra of the vapor phase over HgI2(s,l) were measured for wavelengths between 200 and 600 nm. The spectra show that the sample sublimed congruently into HgI2 with no Hg or I2 absorption spectrum observed. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of H912, P, was established as a function of temperatures for the liquid and the solid Beta-phases. The expressions correspond to the enthalpies of vaporization and sublimation of 15.30 and 20.17 Kcal/mole, respectively, for the liquid and the Beta-phase HgI2. The difference in the enthalpies gives an enthalpy of fusion of 4.87 Kcal/mole and the intersection of the two expressions gives a melting point of 537 K.

Su, Ching-Hua↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

Beer Law Constants and Vapor Pressures of HgI2 over HgI2(s,l)

Optical absorption spectra of the vapor phase over HgI2(s,l) were measured at sample temperatures between 349 and 610 K for wavelengths between 200 and 600 nm. The spectra show the samples sublimed congruently into HGI2 without any observed Hg or I2 absorption spectra. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were derived. From these constants the vapor pressure of HgI2, P, was found to be a function of temperature for the liquid and the solid beta-phases: ln P(atm) = -7700/T(K) + 12.462 (liquid phase) and ln P(atm) = -10150/T(K) + 17.026 (beta-phase). The expressions match the enthalpies of vaporization and sublimation of 15.30 and 20.17 kcal/mole respectively, for the liquid and the beta-phase HgI2. The difference in the enthalpies gives an enthalpy of fusion of 4.87 kcal/mole, and the intersection of the two expressions gives a melting point of 537 K.

Su, Ching-Hua↗

An XMM-Newton Study of 9SGR and the Lagoon Nebula

We report preliminary results of an XMM-Newton observation of the 04 V star 9 Sgr (= HD 164794). 9 Sgr is one of a few single OB stars that display a non-thermal radio emission attributed to synchrotron emission by relativistic electrons. Inverse Compton scattering of photospheric UV photons by these relativistic electrons is a priori expected to generate a non-thermal power-law tail in the X-ray spectrum. Our EPIC and RGS spectra of 9 Sgr suggest a more complex situation than expected from this 'simple' theoretical picture. Furthermore, soft-band EPIC images of the region around 9 Sgr reveal a number of point sources inside the Lagoon Nebula (M8). Most of these sources have optical counterparts inside the very young open cluster NGC 6530 and several X-ray sources are associated with low and intermediate mass pre-main sequence stars. Finally, we also detect (probably) diffuse X-ray emission from the Hourglass Region that might reveal a hot bubble blown by the stellar wind of Herschel 36, the ionizing star of the HG region.

Rauw, G.↗

Transient Torque Technique for Viscosity and Electrical Conductivity Determination of Semiconducting Liquids

A novel apparatus based on transient torque technique is constructed in MSFC/NASA. The apparatus uses a 125um diameter quartz fiber as torsion wire. A high sensitive angular detector is implemented to measure the deflection angle of the crucible containing the liquid. A rotating magnetic field (RMF) is used to induce a rotating flow of a conducting or semiconducting melts. By measuring the magnitude and transient behavior of the induced deflection angle, the electrical conductivity and viscosity of the melt can be measured simultaneously. High purity elements namely Hg, Ga, Zn and Te are tested at room temperature and high temperature up to 900 C.

Li, C.↗

Crystal Growth of HgZnTe Alloy by Directional Solidification in Low Gravity Environment

An Hg(0.84)Zn(0.16)Te alloy crystal was back-melted and partially re-solidified during the first United States Microgravity Laboratory mission in the Marshall Space Flight Center's Crystal Growth Furnace. The experiment was inadvertently terminated at about 30% of planned completion. Nonetheless, it was successfully demonstrated that a HgZnTe alloy ingot partially grown and quenched on the ground can be back-melted and re-grown in space under nearly steady-state growth conditions. An identical "ground-truth" experiment was performed following the mission and a comparison between the properties of the crystals is described. The results indicate the importance of residual microgravity acceleration (less than or approx. equal to 0.4 micro-grams) even in the sub-microgravity range for the slow solidification velocities and large density gradients.

Su, Ching-Hua↗

Electrical Breakdown in a Martian Gas Mixture

The high probability for dust interactions during Martian dust storms and dust devils combined with the cold, dry climate of Mars most likely result in airborne dust that is highly charged. On Earth, potential gradients up to 5 kV/m have been recorded and in some cases resulted in lightning. Although the Martian atmosphere is not conducive to lightning generation, it is widely believed that electrical discharge in the form of a corona occurs. In order to understand the breakdown of gases, Paschen measurements are taken which relate the minimum potential required to spark across a gap between two electrodes. The minimum potential is plotted versus the pressure-distance value for electrodes of a given geometry. For most gases, the potential decreases as the pressure decreases. For CO2, the minimum in the curve happens to be at Mars atmospheric pressures (5-7 mm Hg) for many distances and geometries. However, a very small amount (<0.1%) of mixing gases radically changes the curve, as noted by Leach. Here, we present the first experimental results of a Paschen curve for a Mars gas mixture compared with 100% pure CO2.

Buhler, C. R.↗

Laser-Induced Breakdown Spectroscopy of Trace Metals

An alternative approach for laser-induced breakdown spectroscopy (LIBS) determination of trace metal determination in liquids is demonstrated. The limits of detection (LOD) for the technique ranged from 10 ppb to 10 ppm for 15 metals metals (Mg, Al, Si, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn, As, Cd, Hg, Pb) tested.

Simons, Stephen↗