Plasma heating technology

The operational environment for plasma heating systems presents unprecedented challenges for the success of magnetic fusion. This chapter discusses the current state of ion cyclotron and electron cyclotron heating systems and the research and development priorities needed to establish working solutions for these systems. While much progress has been made, there is much more work to be done to make fusion energy commercially viable. Research and development priorities include radiation-resistant structural and plasma facing materials, advanced manufacturing methods, new cooling methods, first-wall integrated actuators, improvements in power source efficiency, higher frequency gyrotrons, and improved overall system reliability.

Caughman, John↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reference Piping and Instrumentation Diagrams for Heat Transport Systems for Methanol Plants

This report aims to bridge the gap between advanced nuclear reactor vendors and methanol producers seeking decarbonization. It equips both parties with tools and preliminary information for integrating clean heat from advanced reactors into novel methanol production processes. The proposed investigation in this report involves a three-step approach: 1. Design of Current and Decarbonized Process Models for Methanol Production. This report initiates process modeling of two novel methanol production pathways, with their overall energy requirements comparative to classical methanol production (see Figure ES1). The two process models provide the foundation for analyzing integration of hermos-electric generation from advanced nuclear reactors. 2. Identification of Coupling Points to Integrate Advanced Reactors. This report investigates the integration with two advanced reactor technologies: light-water reactors (LWRs) and high-temperature gas reactors (HTGRs). The key coupling points between advanced nuclear reactors and the production facilities associated with the two decarbonized methanol process pathways are identified. 3. Preliminary Heat and Electricity Transfer Design from Reactors to Methanol Production Sites. The preliminary designs for piping and instrumentation to transfer heat from the boundary of advanced reactor technology location to the boundary of methanol production site are evaluated within the context of decarbonized pathways. The pipe analysis for heat transfer adheres to relevant codes and specifications from American Society of Mechanical Engineering. A simplified design for transmission of electricity to the industrial site has been provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An experimental and theoretical investigation of the liquefaction dynamics of a phase change material in a normal gravity environment

Experimental and theoretical investigations were undertaken to determine the role of gravity-induced free convection upon the liquefaction dynamics of a cylindrical paraffin slab under normal gravity conditions. The experimental equipment consisted of a test cell, a fluid-loop heating system, and a multipoint recorder. The test chamber was annular in shape with an effective radius of 1.585 cm and a length of 5.08 cm. The heating chamber was a 1.906 cm diameter tube going through the center of the test chamber, and connected to the fluid loop heating system. All experimental runs were made with the longitudinal axis of the test cell in the vertical direction to insure that convection was not a function of the angular axis of the cell. Ten melting runs were made at various hot wall temperatures. Also, two pure conduction solidification runs were made to determine an experimental latent heat of fusion.

Bain, R. L.↗

Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Heating and Cooling Equipment-Efficiency Upgrade Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The specific measure described here involves improving the overall efficiency in air-conditioning systems as a whole (compressor, evaporator, condenser, and supply fan). The efficiency rating is expressed as the energy efficiency ratio (EER), seasonal energy efficiency ratio (SEER), and integrated energy efficiency ratio (IEER). The higher the EER, SEER or IEER, the more efficient the unit is.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life cycle cost analysis comparing redesigned CCHP to existing heat pump systems for cities in cold climates

This report indicates that the project progress has met the Go criterion, i.e. demonstrating favorable results of life cycle cost assessment for the redesigned CCHPs. Considering the market price of a baseline heat pump, and required improvements in heat exchangers, fans and an electronic expansion valve of the CCHPs, we estimated that the CCHP using a 3-stage scroll compressor will incur with a cost increment of $\$386$ per rated cooling tonnage, and the CCHP using tandem compressors will increase by $\$770$. Based on the energy savings of the CCHPs, simulated by EnergyPlus, the two CCHPs achieve payback periods less than 4 years among all the cold climate cities. Within a typical heat pump life cycle of 20 years, the CCHPs can achieve cost savings around $\$2000$ per rated cooling tonnage, and the savings are even higher for the extremely cold cities like Duluth and Fairbanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings

This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB)

This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau Places within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped risk of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied. UPDATE: Newer version of the Utilization Analysis has been added here: https://gdr.openei.org/submissions/878

15 GEOTHERMAL ENERGY↗

Heat pipe radiation cooling of advanced hypersonic propulsion system components

Heat transfer, heat pipe, and system studies were performed to assess the newly proposed heat pipe radiation cooling (HPRC) concept. With an HPRC system, heat is removed from the ramburner and nozzle of a hypersonic aircraft engine by a surrounding, high-temperature, heat pipe nacelle structure, transported to nearby external surfaces, and rejected to the environment by thermal radiation. With HPRC, the Mach number range available for using hydrocarbon fuels for aircraft operation extends into the Mach 4 to Mach 6 range, up from the current limit of about Mach 4. Heat transfer studies using a newly developed HPRC computer code determine cooling system and ramburner and nozzle temperatures, heat loads, and weights for a representative combined-cycle engine cruising at Mach 5 at 80,000 ft altitude. Heat pipe heat transport calculations, using the Los Alamos code HTPIPE, reveal that adequate heat trasport capability is available using molybdenum-lithium heat pipe technology. Results show that the HPRC system radiator area is limited in size to the ramburner-nozzle region of the engine nacelle; reasonable system weights are expected; hot section temperatures are consistent with advanced structural materials development goals; and system impact on engine performance is minimal.