Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat transfer performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Thermal-striping analysis methodology for sodium-cooled reactor design

Computational fluid dynamics simulations have been performed to study the applicability of engineering CFD methods for thermals striping analysis. Thermal striping is the fluctuating temperature profile in a solid caused by fluctuating fluid temperature, and the resulting fluctuating thermal stresses cause high cycle fatigue and eventual material failure. Here this study presents the methodology for thermal striping analysis that including a transient conjugate heat transfer RANS model and benchmark the results against a sodium triple jet experiment. The multiphysics calculations are implemented to analyze the thermal stresses in the solid domain caused by the coupled heat transfer between the fluid and solid domains. Validation data from a liquid sodium triple jet experiment include time-averaged temperature measurements and power spectra of the temperature signal. The numerical results agree well with these experimental measures, demonstrating key features such as the dominant frequency of temperature fluctuations. The applicability of a low-cost wall treatment method is demonstrated, enabling key computational savings. Finally, the performance of two finite element stress analysis software packages is compared, and the validity of the lower-cost method is confirmed. These results demonstrate the applicability of engineering methods for computational thermal striping calculations, enabling thermal striping estimations in large fluid systems such as the core of a Sodium-cooled nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

This paper describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to develop a new method to relate film cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. This paper presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained, and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This paper is relevant to conjugate test rigs that can measure the hot surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced gas turbines↗

THERMAL SAFETY MARGIN CALCULATION OF THE MP-2 EXPERIMENT IN THE ADVANCED TEST REACTOR

The Mini-Plate 2 (MP-2) irradiation test is a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). The experiment is a drop-in test where small aluminum-clad fuel plate samples (mini plates) are cooled directly by the ATR Primary Coolant System (PCS) water. The MP-2 fuel plate experiment will be irradiated in several different irradiation locations of the ATR. This fueled experiment contains aluminum-clad fuel mini plates consisting of monolithic U-Mo. Four different types of fuel plates with fuel meat thickness and cladding are part of the MP-2 test. A thermal analysis has been performed on the MP-2 experiment. A method for calculating Departure from Nucleate Boiling Ratio (DNBR) and Flow Instability Ratio (FIR) during a reactivity transient using the commercial finite element and heat transfer code ABAQUS is discussed. At the start of an ATR cycle the heat generation rate of the fueled experiment is high and the heat rate multiplier from the outer shim control cylinders is low, while the reverse is true at the end of the ATR cycle. Thermal analyses at 10 day increments during the cycle calculate the DNBR and FIR during a reactivity transient. This technique calculates DNBR for the fuel plate surfaces and FIR for all water components for each finite element surface and node at various times during the ATR cycle. Heat rates vary with time during the transient calculation that are provided by a detailed physics analysis. Oxide growth on the fuel plates is also incorporated Results from the transient calculations are displayed with the ABAQUS post processor. By calculating these parameters at each location in the finite element model, conservatism is replaced with accuracy. This allows for a greater margin for the thermal hydraulic safety parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling Parallel Execution of System-level Simulations in SAM

This report summarizes the recent code updates related to “element ghosting” in SAM to enable the parallel execution of system-level simulations using multiple processors/cores. Unlike typical MOOSE-based applications, for system-level simulations, SAM mostly deals with a collection of discrete small pieces of meshes, and the connection of physics on these meshes are realized by using “connector” types of components/code structures, such as conjugate heat transfer and flow junctions. The required code implementation is to correctly mark the necessary ghost elements for each type of such components/code structures; thus, the lower-level libraries can correctly perform the necessary data transfer between processors (CPUs) when executed in parallel mode. After the code updates, SAM can now run system-level simulations in the parallel mode. The parallel execution capability was then tested with an ABTR input model with 23k DOFs. Significant speedup was demonstrated when the optimal number of CPUs were used in parallel mode. Future systematic studies on parallelization performance using additional test cases covering different physics/scenarios will be needed to provide additional insights into the scalability of SAM parallelization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

In the pursuit of more efficient gas turbines, film cooling is a critical technology. This article describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to relate film-cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. Here, this article presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film-cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This article is relevant to conjugate test rigs that can measure the hot-surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced turbines↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

General Correlations for Laminar Flow Friction Loss and Heat Transfer in Plain Rectangular Plate-Fin Cores

In this paper, new generalized correlations for predicting the average fanning friction factor f and average Nusselt number Nu for laminar flow in plain plate-fin compact cores of rectangular cross section are presented. These are based on extended experimental data, as well as three-dimensional computational simulations, obtained for a broad range of fin density and geometrical attributes. The results indicate that while the fully developed forced convection scales only with the interfin channel cross-sectional ratio α (fin spacing by fin height), the entrance region hydrodynamic and thermal performance is additionally a function of the fin-core length L, flow Reynolds number Re, and fluid Prandtl number Pr. The developing flow and convection is further shown to scale as: (fRe)~(L/d h Re) 1/2 , and Nu ~(L/d h Re) 1/2 Pr 1/3 Φ(α), where f, Re, and Nu are all based on the hydraulic diameter dh of the interfin flow channel. Generalized correlations for both (fRe) and Nu are developed by the corresponding scaling of the forced convection behavior and asymptotic matching of the entrance or developing flow (short fin-core flow length) and the fully developed flow (large fin-core flow length) region performance. Finally, the predictions from these correlations are found to be within ±15% of all available experimental data for air, water, and glycol (0.71 ≤ Pr ≤ 10), and fin cores with 0 < α ≤ 1.

36 MATERIALS SCIENCE↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Techno-Economic Optimization of a Solvent Absorption Process for CO2 Capture with 3D-Printed Intensified Packing

Presentation given at the 2024 annual AICHE meeting held October 27-31, 2024. The presentation focuses on modeling performance and economics of a solvent absorption system for CO2 capture with towers utilizing intensified packing. The packing is an alternative to traditional structured packing by incorporating cooling channel for simultaneous mass and heat transfer.

Summits, Stephen↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗