Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Importance of Small Prostate Size in Men Receiving Definitive Prostate Brachytherapy

Purpose: To assess whether small prostate size is an adverse prognostic factor in men undergoing brachytherapy in the same manner in which it seems to be for men undergoing radical prostatectomy. Methods and Materials: From April 1995 to June 2008, 2024 patients underwent brachytherapy by a single brachytherapist. Median follow-up was 7.4 years. The role of small prostate size ({<=}20 cm{sup 3}) as a prognostic factor for biochemical progression-free survival, cause-specific survival, and all-cause mortality was investigated. The differences in survival between men with small and larger prostates were compared using Kaplan-Meier curves and log-rank tests. Results: Median prostate size for the entire cohort was 32.7 cm{sup 3}. For the 167 men with small prostates, median prostate size was 17.4 cm{sup 3}. There was no difference in biochemical progression-free survival (95.2% vs 96.2%, P=.603), cause-specific survival (97.7% vs 98.3%, P=.546), or all-cause mortality (78.0% vs 77.2%, P=.838) at 10 years for men with small prostates compared with men with larger prostates. On univariate and multivariate analysis, small prostate size was not associated with any of the primary outcome measures. Conclusion: Men with small prostates treated with brachytherapy have excellent outcomes and are at no higher risk of treatment failure than men with larger glands. High-quality implants with adequate margins seem sufficient to address the increased adverse risk factors associated with small prostate size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Concurrent Androgen Deprivation on Fiducial Marker Migration in External-beam Radiation Therapy for Prostate Cancer

Purpose: To determine the extent of gold fiducial marker (FM) migration in patients treated for prostate cancer with concurrent androgen deprivation and external-beam radiation therapy (EBRT). Methods and Materials: Three or 4 gold FMs were implanted in 37 patients with prostate adenocarcinoma receiving androgen deprivation therapy (ADT) in conjunction with 70-78 Gy. Androgen deprivation therapy was started a median of 3.9 months before EBRT (range, 0.3-12.5 months). To establish the extent of FM migration, the distance between each FM was calculated for 5-8 treatments once per week throughout the EBRT course. For each treatment, the distance between FMs was compared with the distance from the digitally reconstructed radiographs generated from the planning CT. A total of 281 treatments were analyzed. Results: The average daily migration was 0.8 {+-} 0.3 mm, with distances ranging from 0.2 mm-2.6 mm. Two of the 281 assessed treatments (0.7%) showed migrations >2 mm. No correlation between FM migration and patient weight or time delay between ADT and start of EBRT was found. There was no correlation between the extent of FM migration and prostate volume. Conclusion: This is the largest report of implanted FM migration in patients receiving concomitant ADT. Only 0.7% of the 281 treatments studied had significant marker migrations (>2 mm) throughout the course of EBRT. Consequently, the use of implanted FMs in these patients enables accurate monitoring of prostate gland position during treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability Modeling of Radiation-Induced Hypothyroidism After Head-and-Neck Radiation Therapy

Purpose: To determine the dose-response relationship of the thyroid for radiation-induced hypothyroidism in head-and-neck radiation therapy, according to 6 normal tissue complication probability models, and to find the best-fit parameters of the models. Methods and Materials: Sixty-five patients treated with primary or postoperative radiation therapy for various cancers in the head-and-neck region were prospectively evaluated. Patient serum samples (tri-iodothyronine, thyroxine, thyroid-stimulating hormone [TSH], free tri-iodothyronine, and free thyroxine) were measured before and at regular time intervals until 1 year after the completion of radiation therapy. Dose-volume histograms (DVHs) of the patients' thyroid gland were derived from their computed tomography (CT)-based treatment planning data. Hypothyroidism was defined as increased TSH (subclinical hypothyroidism) or increased TSH in combination with decreased free thyroxine and thyroxine (clinical hypothyroidism). Thyroid DVHs were converted to 2 Gy/fraction equivalent doses using the linear-quadratic formula with {alpha}/{beta} = 3 Gy. The evaluated models included the following: Lyman with the DVH reduced to the equivalent uniform dose (EUD), known as LEUD; Logit-EUD; mean dose; relative seriality; individual critical volume; and population critical volume models. The parameters of the models were obtained by fitting the patients' data using a maximum likelihood analysis method. The goodness of fit of the models was determined by the 2-sample Kolmogorov-Smirnov test. Ranking of the models was made according to Akaike's information criterion. Results: Twenty-nine patients (44.6%) experienced hypothyroidism. None of the models was rejected according to the evaluation of the goodness of fit. The mean dose model was ranked as the best model on the basis of its Akaike's information criterion value. The D{sub 50} estimated from the models was approximately 44 Gy. Conclusions: The implemented normal tissue complication probability models showed a parallel architecture for the thyroid. The mean dose model can be used as the best model to describe the dose-response relationship for hypothyroidism complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thyroid Adenomas After Solid Cancer in Childhood

Purpose: Very few childhood cancer survivor studies have been devoted to thyroid adenomas. We assessed the role of chemotherapy and the radiation dose to the thyroid in the risk of thyroid adenoma after childhood cancer. Methods and Materials: A cohort of 3254 2-year survivors of a solid childhood cancer treated in 5 French centers before 1986 was established. The dose received by the isthmus and the 2 lobes of the thyroid gland during each course of radiation therapy was estimated after reconstruction of the actual radiation therapy conditions in which each child was treated as well as the dose received at other anatomical sites of interest. Results: After a median follow-up of 25 years, 71 patients had developed a thyroid adenoma. The risk strongly increased with the radiation dose to the thyroid up to a few Gray, plateaued, and declined for high doses. Chemotherapy slightly increased the risk when administered alone but also lowered the slope of the dose-response curve for the radiation dose to the thyroid. Overall, for doses up to a few Gray, the excess relative risk of thyroid adenoma per Gray was 2.8 (90% CI: 1.2-6.9), but it was 5.5 (90% CI: 1.9-25.9) in patients who had not received chemotherapy or who had received only 1 drug, and 1.1 (90% CI: 0.4-3.4) in the children who had received more than 1 drug (P=.06, for the difference). The excess relative risk per Gray was also higher for younger children at the time of radiation therapy than for their older counterparts and was higher before attaining 40 years of age than subsequently. Conclusions: The overall pattern of thyroid adenoma after radiation therapy for a childhood cancer appears to be similar to that observed for thyroid carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Importance of Gleason 7 Disease Among Patients Treated With External Beam Radiation Therapy for Prostate Cancer: Results of a Detailed Biopsy Core Analysis

Purpose: To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). Methods and Materials: From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6 years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). Results: The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Conclusions: Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase 1 Study of Everolimus + Weekly Cisplatin + Intensity Modulated Radiation Therapy in Head-and-Neck Cancer

Purpose: Elevated expression of eukaryotic protein synthesis initiation factor 4E (eIF4E) in histologically cancer-free margins of resected head and neck squamous cell carcinomas (HNSCCs) is mediated by mammalian target of rapamycin complex 1 (mTORC1) and has been associated with increased risk of disease recurrence. Preclinically, inhibition of mTORC1 with everolimus sensitizes cancer cells to cisplatin and radiation. Methods and Materials: This was single-institution phase 1 study to establish the maximum tolerated dose of daily everolimus given with fixed dose cisplatin (30 mg/m{sup 2} weekly × 6) and concurrent intensity modulated radiation therapy for patients with locally and/or regionally advanced head-and-neck cancer. The study had a standard 3 + 3 dose-escalation design. Results: Tumor primary sites were oral cavity (4), salivary gland (4), oropharynx (2), nasopharynx (1), scalp (1), and neck node with occult primary (1). In 4 of 4 cases in which resected HNSCC surgical pathology specimens were available for immunohistochemistry, elevated expression of eIF4E was observed in the cancer-free margins. The most common grade ≥3 treatment-related adverse event was lymphopenia (92%), and dose-limiting toxicities (DLTs) were mucositis (n=2) and failure to thrive (n=1). With a median follow up of 19.4 months, 2 patients have experienced recurrent disease. The maximum tolerated dose was everolimus 5 mg/day. Conclusions: Head-and-neck cancer patients tolerated everolimus at therapeutic doses (5 mg/day) given with weekly cisplatin and intensity modulated radiation therapy. The regimen merits further evaluation, especially among patients who are status post resection of HNSCCs that harbor mTORC1-mediated activation of eIF4E in histologically negative surgical margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multidisciplinary Orbit-Sparing Treatment Approach That Includes Proton Therapy for Epithelial Tumors of the Orbit and Ocular Adnexa

Purpose: Postoperative radiation is often indicated in the treatment of malignant epithelial tumors of the orbit and ocular adnexa. We present details of radiation technique and toxicity data after orbit-sparing surgery followed by adjuvant proton radiation therapy. Methods and Materials: Twenty patients underwent orbit-sparing surgery followed by proton therapy for newly diagnosed malignant epithelial tumors of the lacrimal gland (n=7), lacrimal sac/nasolacrimal duct (n=10), or eyelid (n=3). Tumor characteristics, treatment details, and visual outcomes were obtained from medical records. Acute and chronic toxicity were prospectively scored using Common Terminology Criteria for Adverse Events version 4.0. Results: The median radiation dose was 60 Gy(RBE) (relative biological effectiveness; [range 50-70 Gy]); 11 patients received concurrent chemotherapy. Dose to ipsilateral anterior optic structures was reduced in 13 patients by having them gaze away from the target during treatment. At a median follow-up time of 27.1 months (range 2.6-77.2 months), no patient had experienced local recurrence; 1 had regional and 1 had distant recurrence. Three patients developed chronic grade 3 epiphora, and 3 developed grade 3 exposure keratopathy. Four patients experienced a decrease in visual acuity from baseline but maintained vision sufficient to perform all activities of daily living without difficulty. Patients with grade ≥3 chronic ocular toxicity had higher maximum dose to the ipsilateral cornea (median 46.3 Gy[RBE], range 36.6-52.7 Gy[RBE] vs median 37.4 Gy[RBE], range 9.0-47.3 Gy(RBE); P=.017). Conclusions: Orbit-sparing surgery for epithelial tumors of the orbit and ocular adnexa followed by proton therapy successfully achieved disease control and was well tolerated. No patient required orbital exenteration or enucleation. Chronic grade 3 toxicity was associated with high maximum dose to the cornea. An eye-deviation technique can be used to limit the maximum corneal dose to <35 Gy(RBE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Minibeam Radiation Therapy Reduces Side Effects in an In Vivo Mouse Ear Model

Purpose: Proton minibeam radiation therapy is a novel approach to minimize normal tissue damage in the entrance channel by spatial fractionation while keeping tumor control through a homogeneous tumor dose using beam widening with an increasing track length. In the present study, the dose distributions for homogeneous broad beam and minibeam irradiation sessions were simulated. Also, in an animal study, acute normal tissue side effects of proton minibeam irradiation were compared with homogeneous irradiation in a tumor-free mouse ear model to account for the complex effects on the immune system and vasculature in an in vivo normal tissue model. Methods and Materials: At the ion microprobe SNAKE, 20-MeV protons were administered to the central part (7.2 × 7.2 mm{sup 2}) of the ear of BALB/c mice, using either a homogeneous field with a dose of 60 Gy or 16 minibeams with a nominal 6000 Gy (4 × 4 minibeams, size 0.18 × 0.18 mm{sup 2}, with a distance of 1.8 mm). The same average dose was used over the irradiated area. Results: No ear swelling or other skin reactions were observed at any point after minibeam irradiation. In contrast, significant ear swelling (up to fourfold), erythema, and desquamation developed in homogeneously irradiated ears 3 to 4 weeks after irradiation. Hair loss and the disappearance of sebaceous glands were only detected in the homogeneously irradiated fields. Conclusions: These results show that proton minibeam radiation therapy results in reduced adverse effects compared with conventional homogeneous broad-beam irradiation and, therefore, might have the potential to decrease the incidence of side effects resulting from clinical proton and/or heavy ion therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Proton Beam Therapy for Ocular Melanoma Using a Novel 3D Treatment Planning Technique

Purpose: We evaluated sparing of normal structures using 3-dimensional (3D) treatment planning for proton therapy of ocular melanomas. Methods and Materials: We evaluated 26 consecutive patients with choroidal melanomas on a prospective registry. Ophthalmologic work-up included fundoscopic photographs, fluorescein angiography, ultrasonographic evaluation of tumor dimensions, and magnetic resonance imaging of orbits. Three tantalum clips were placed as fiducial markers to confirm eye position for treatment. Macula, fovea, optic disc, optic nerve, ciliary body, lacrimal gland, lens, and gross tumor volume were contoured on treatment planning compute tomography scans. 3D treatment planning was performed using noncoplanar field arrangements. Patients were typically treated with 3 fields, with at least 95% of planning target volume receiving 50 GyRBE in 5 fractions. Results: Tumor stage was T1a in 10 patients, T2a in 10 patients, T2b in 1 patient, T3a in 2 patients, T3b in 1 patient, and T4a in 2 patients. Acute toxicity was mild. All patients completed treatment as planned. Mean optic nerve dose was 10.1 Gy relative biological effectiveness (RBE). Ciliary body doses were higher for nasal (mean: 11.4 GyRBE) than temporal tumors (5.8 GyRBE). Median follow-up was 31 months (range: 18-40 months). Six patients developed changes which required intraocular bevacizumab or corticosteroid therapy, but only 1 patient developed neovascular glaucoma. Five patients have since died: 1 from metastatic disease and 4 from other causes. Two patients have since required enucleation: 1 due to tumor and 1 due to neovascular glaucoma. Conclusions: 3D treatment planning can be used to obtain appropriate coverage of choroidal melanomas. This technique is feasible with relatively low doses to anterior structures, and appears to have acceptable rates of local control with low risk of enucleation. Further evaluation and follow-up is needed to determine optimal dose-volume relationships for organs at risk to decrease complications rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reirradiation of Prostate Cancer Local Failures After Previous Curative Radiation Therapy: Long-Term Outcome and Tolerance

Purpose: To evaluate the safety, feasibility, side-effect profile, and proof of concept of external beam radiation therapy (EBRT) with or without a brachytherapy (BT) boost for salvage of exclusive local failure after primary EBRT for prostate cancer. Methods and Materials: Fourteen patients with presumed exclusive local recurrence after primary EBRT with or without BT were considered eligible for reirradiation. The median normalized total dose in 2-Gy fractions (NTD{sub 2Gy}, α/β ratio = 1.5 Gy) was 74 Gy (range, 66-98.4 Gy) at first irradiation. Median time between the first irradiation and the reirradiation was 6.1 years (range, 4.7-10.2 years). Results: Between 2003 and 2008 salvage treatment was delivered with a median NTD{sub 2Gy} of 85.1 Gy (range, 70-93.4) to the prostate with EBRT with (n=10) or without (n=4) BT. Androgen deprivation was given to 12 patients (median time of 12 months). No grade ≥3 toxicity was observed during and within 6 weeks after RT. After a median follow-up of 94 months (range, 48-172 months) after salvage RT, 5-year grade ≥3 genitourinary and gastrointestinal toxicity-free survival figures were 77.9% ± 11.3% and 57.1% ± 13.2%, respectively. Four patients presented with combined grade 4 genitourinary/gastrointestinal toxicity. The 5-year biochemical relapse-free, local relapse-free, distant metastasis-free, and cancer-specific survival rates were 35.7% ± 12.8%, 50.0% ± 13.4%, 85.7% ± 9.4%, and 100%, respectively. Conclusion: Salvage whole-gland reirradiation for patients with a suspicion of exclusive local recurrence after initial RT may be associated with a high rate of severe radiation-induced side effects and poor long-term biochemical and local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Patient-specific Dosimetric Benefits of Proton Therapy for Skull-base Tumors Using a Geometric Knowledge-based Method

Purpose: To predict the organ at risk (OAR) dose levels achievable with proton beam therapy (PBT), solely based on the geometric arrangement of the target volume in relation to the OARs. A comparison with an alternative therapy yields a prediction of the patient-specific benefits offered by PBT. This could enable physicians at hospitals without proton capabilities to make a better-informed referral decision or aid patient selection in model-based clinical trials. Methods and Materials: Skull-base tumors were chosen to test the method, owing to their geometric complexity and multitude of nearby OARs. By exploiting the correlations between the dose and distance-to-target in existing PBT plans, the models were independently trained for 6 types of OARs: brainstem, cochlea, optic chiasm, optic nerve, parotid gland, and spinal cord. Once trained, the models could estimate the feasible dose–volume histogram and generalized equivalent uniform dose (gEUD) for OAR structures of new patients. The models were trained using 20 patients and validated using an additional 21 patients. Validation was achieved by comparing the predicted gEUD to that of the actual PBT plan. Results: The predicted and planned gEUD were in good agreement. Considering all OARs, the prediction error was +1.4 ± 5.1 Gy (mean ± standard deviation), and Pearson's correlation coefficient was 93%. By comparing with an intensity modulated photon treatment plan, the model could classify whether an OAR structure would experience a gain, with a sensitivity of 93% (95% confidence interval: 87%-97%) and specificity of 63% (95% confidence interval: 38%-84%). Conclusions: We trained and validated models that could quickly and accurately predict the patient-specific benefits of PBT for skull-base tumors. Similar models could be developed for other tumor sites. Such models will be useful when an estimation of the feasible benefits of PBT is desired but the experience and/or resources required for treatment planning are unavailable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicenter Evaluation of Biochemical Relapse–Free Survival Outcomes for Intraoperatively Planned Prostate Brachytherapy Using an Automated Delivery System

Purpose: To report biochemical recurrence in prostate cancer treated with intraoperatively planned low-dose-rate prostate brachytherapy using an automated delivery system (IO-LDRB). Methods and Materials: Between 2003 and 2013, 2608 patients from 3 centers were treated with IO-LDRB as single-modality treatment for low or low-tier intermediate-risk prostate cancer. Databases from the 3 centers have been analyzed. These independent databases were collected prospectively. Patient, tumor, and treatment characteristics were then compared, Kaplan-Meier survival estimates of biochemical relapse–free survival (bRFS) were generated, and the Cox proportional hazards model was used to determine factors predicting for relapse. Results: A total of 2608 patients with a median follow-up of 4.7 (interquartile range, 3.1-6.9) years were analyzed. Median age was 64 (range, 42-84) years. In these patients, median initial prostate-specific antigen was 5.5 ng/mL, 74% were T1, and 26% were T2; 73% were Gleason 6, and 25% Gleason 7. Median percentage of biopsy cores positive was 33%, and median gland volume was 34.2 cm{sup 3}. Eleven percent of patients received hormones for a median of 3.0 months before implantation. Median seed activity was 0.437 mCi, D90 (dose covering 90% of the prostate volume) was 186.7 Gy, and V100 was 99.37%. Biochemical relapse was observed in 124 patients (4.8%), and median time to failure was 4.0 years. Predicted bRFS was 93% at 7 years. On Cox regression bRFS was dependent only on D90 at the time of implantation and prostate-specific antigen density. Conclusions: This study demonstrates that IO-LDRB is an effective treatment option for patients with low and low-tier intermediate-risk prostate cancer. Rates of biochemical relapse remain low several years after treatment. These results compared favorably to published manual preplan technique results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical and dosimetric implications of intensity-modulated radiotherapy for early-stage glottic carcinoma

Conventional parallel-opposed radiotherapy (PORT) is the established standard technique for early-stage glottic carcinoma. However, case reports have reported the utility of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) with or without image guidance (image-guided radiotherapy, IGRT) in select patients. The proposed advantages of IMRT/VMAT include sparing of the carotid artery, thyroid gland, and the remaining functional larynx, although these benefits remain unclear. The following case study presents a patient with multiple vascular comorbidities treated with VMAT for early-stage glottic carcinoma. A detailed explanation of the corresponding treatment details, dose-volume histogram (DVH) analysis, and a review of the relevant literature are provided. Conventional PORT remains the standard of care for early-stage glottic carcinoma. IMRT or VMAT may be beneficial for select patients, although great care is necessary to avoid a geographical miss. Clinical data supporting the benefit of CRT are lacking. Therefore, these techniques should be used with caution and only in selected patients.

61 RADIATION PROTECTION AND DOSIMETRY↗