Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A 380 GHz SIS receiver using Nb/AlO(x)/Nb junctions for a radioastronomical balloon-borne experiment: PRONAOS

The superheterodyne detection technique used for the spectrometer instrument of the PRONAOS project will provide a very high spectral resolution (delta nu/nu = 10(exp -6)). The most critical components are those located at the front-end of the receiver: their contribution dominates the total noise of the receiver. Therefore, it is important to perform accurate studies for specific components, such as mixers and multipliers working in the submillimeter wave range. Difficulties in generating enough local oscillator (LO) power at high frequencies make SIS mixers very desirable for operation above 300 GHz. The low LO power requirements and the low noise temperature of these mixers are the primary reason for building an SIS receiver. This paper reports the successful fabrication of small (less than or equal to 1 sq micron) Nb/Al-O(x)/Nb junctions and arrays with excellent I-V characteristics and very good reliability, resulting in a low noise receiver performance measured in the 368/380 GHz frequency range.

Febvre, P.↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conductive Spray Paint Fabricated Cylindrical Coplanar Waveguide for Noncontact Liquid-Level Sensing

A noncontact liquid-level sensor using a cylindrical coplanar waveguide (CCPW) is proposed. The concept is demonstrated using a prototype device made by directly spraying conductive paint on the outer surface of a glass cylinder. The position of the air–liquid interface is measured using the time-domain reflection (TDR) signal from the CCPW. The geometric parameters of the prototype sensor were optimized using a full-wave simulation tool. The experimental results show that the prototype CCPW-based liquid-level sensor has a resolution of 29.8μm over a range of 210 mm at the sweeping frequency bandwidth of 500 MHz–4 GHz. The tradeoff between the resolution and the measurement range was discussed. The proposed sensor provides a low-cost, easy-to-fabricate, and noncontact method for liquid-level measurement, which has potential applications in fuel storage, chemical production, and wastewater treatment.

42 ENGINEERING↗

Optical Sidebands Multiplier

Optical sidebands have been generated with relative frequency tens to hundreds of GHz by using optical sidebands that are generated in a cascade process in high-quality optical resonators with Kerr nonlinearity, such as whispering gallery mode (WGM) resonators. For this purpose, the WGM resonator needs to be optically pumped at two frequencies matching its resonances. These two optical components can be one or several free spectral ranges (FSRs), equal to approximately 12 GHz, in this example, apart from each other, and can be easily derived from a monochromatic pump with an ordinary EOM (electro-optic modulation) operating at half the FSR frequency. With sufficient nonlinearity, an optical cascade process will convert the two pump frequencies into a comb-like structure extending many FSRs around the carrier frequency. This has a demonstratively efficient frequency conversion of this type with only a few milliwatt optical pump power. The concept of using Kerr nonlinearity in a resonator for non-degenerate wave mixing has been discussed before, but it was a common belief that this was a weak process requiring very high peak powers to be observable. It was not thought possible for this approach to compete with electro-optical modulators in CW applications, especially those at lower optical powers. By using the high-Q WGM resonators, the effective Kerr nonlinearity can be made so high that, using even weak seeding bands available from a conventional EOM, one can effectively multiply the optical sidebands, extending them into an otherwise inaccessible frequency range.

Strekalov, Dmitry V.↗

Microjansky source counts and spectral indices at 8.44 GHz

Deep images were made with 10 arcsec resolution at 8.44 GHz with microjansky sensitivity of two regions previously imaged at several lower frequencies. The differential microjansky source count fits a power-law distribution with slope 2.3 +/- 0.2. This slope is roughly constant between 1.41 and 8.44 GHz and between S(v) = about 4 and X(v) = 1000 microJy. Unless the majority of radio sources at microJy levels are local, their average luminosity and/or space density probably has evolved with cosmic epoch in order to sustain the steep and nearly Euclidean value of the slope over such a large range in flux density. The 8.44 GHz counts probably converge at less than the 1 microjansky level if the evolutionary properties of these weak sources are similar to those of luminous gE radio galaxies and quasars. The median angular size of sources detected at 8.44 GHz at microjansky levels is 2.6 +/- 1.4 arcsec, and 40 percent of the source are larger than 5 arcsec.

Windhorst, Rogier A.↗

Radio flares from AE Aquarii - A low-power analog to Cygnus X-37

The magnetic cataclysmic variable AE Aquarii has been observed at 1.5, 4.9, 15, and 22.5 GHz. The source shows temporal variations in the flux density, often with a flarelike morphology. The flux variations are at times extreme, with values ranging from 1-12 mJy at 15 GHz; the degree of variability increases with frequency. The spectrum shows a variety of short-term behavior, at times increasing as nu, at other times decreasing with nu, and at still others flat. The long-term average of the spectrum increases as nu exp 0.3-0.4. No significant degree of circular polarization was observed. The source properties can be explained as a superposition of flare events in which electrons are accelerated to relativistic energies which then emit synchrotron radiation in discrete, expanding sources. The origin of the flare events may be connected to the disruption of the accretion disk some ditance from the white dwarf primary. The radio emission of AE Aqr shows similarities to the low-level flares from Cygnus X-3.

Bastian, T. S.↗

Flaring Stars in a Non-targeted mm-wave Survey with SPT-3G

We present a flare star catalog from four years of non-targeted millimeter-wave survey data from the South Pole Telescope (SPT). The data were taken with the SPT-3G camera and cover a 1500-square-degree region of the sky from $20^{h}40^{m}0^{s}$ to $3^{h}20^{m}0^{s}$ in right ascension and $-42^{\circ}$ to $-70^{\circ}$ in declination. This region was observed on a nearly daily cadence from 2019-2022 and chosen to avoid the plane of the galaxy. A short-duration transient search of this survey yields 111 flaring events from 66 stars, increasing the number of both flaring events and detected flare stars by an order of magnitude from the previous SPT-3G data release. We provide cross-matching to Gaia DR3, as well as matches to X-ray point sources found in the second ROSAT all-sky survey. We have detected flaring stars across the main sequence, from early-type A stars to M dwarfs, as well as a large population of evolved stars. These stars are mostly nearby, spanning 10 to 1000 parsecs in distance. Most of the flare spectral indices are constant or gently rising as a function of frequency at 95/150/220 GHz. The timescale of these events can range from minutes to hours, and the peak $\nu L_{\nu}$ luminosities range from $10^{27}$ to $10^{31}$ erg s$^{-1}$ in the SPT-3G frequency bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent Results on the Accurate Measurements of the Dielectric Constant of Seawater at 1.413GHZ

Measurements of the complex. dielectric constant of seawater at 30.00 psu, 35.00 psu and 38.27 psu over the temperature range from 5 C to 3 5 at 1.413 GHz are given and compared with the Klein-Swift results. A resonant cavity technique is used. The calibration constant used in the cavity perturbation formulas is determined experimentally using methanol and ethanediol (ethylene glycol) as reference liquids. Analysis of the data shows that the measurements are accurate to better than 1.0% in almost all cases studied.

Lang, R.H.↗

High background photon counting lidar

Photon counting with lidar returns is usually limited to low light levels, while wide dynamic range is achieved by counting for long times. The broad emission spectrum of inexpensive high-power semiconductor lasers makes receiver filters pass too much background light for traditional photon counting in daylight. Very high speed photon counting is possible, however, at more than 500 MHz which allows the construction of eyesafe lidar operating in the presence of bright clouds. Detector improvements are possible to count to 20 GHz producing a single shot dynamic range of ten decades.

Lentz, W. J.↗

Brightness temperature and attenuation diversity statistics at 20.6 and 31.65 GHz for the Colorado Research Network

A limited network of four dual-channel microwave radiometers, with frequencies of 20.6 and 31.65 GHz, was operated in the front range of eastern Colorado from 1985 to 1988. Data, from November 1987 through October 1988 are analyzed to determine both single-station and joint-station brightness temperature and attenuation statistics. Only zenith observations were made. The spatial separations of the stations varied from 50 km to 190 km. Before the statistics were developed, the data were screened by rigorous quality control methods. One such method, that of 20.6 vs. 31.65 GHz scatter plots, is analyzed in detail, and comparisons are made of measured vs calculated data. At 20.6 and 31.65 GHz, vertical attenuations of 5 and 8 dB are exceeded 0.01 percent of the time. For these four stations and at the same 0.01 percent level, diversity gains from 6 to 8 dB are possible with the 50 to 190 km separations.

Westwater, Ed R.↗

Ionospheric calibration for single frequency altimeter measurements

This study is a preliminary analysis of the effectiveness (in terms of altimeter calibration accuracy) of various ionosphere models and the Global Positioning System (GPS) to calibrate single frequency altimeter height measurements for ionospheric path delay. In particular, the research focused on ingesting GPS Total Electron Content (TEC) data into the physical Parameterized Real-Time Ionospheric Specification Model (PRISM), which estimates the composition of the ionosphere using independent empirical and physical models and has the capability of adjusting to additional ionospheric measurements. Two types of GPS data were used to adjust the PRISM model: GPS receiver station data mapped from line-of-sight observations to the vertical at the point of interest and a grid map (generated at the Jet Propulsion Laboratory) of GPS derived TEC in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by the International Reference Ionosphere (IRI-90), a climatological (monthly mean) model of the ionosphere, were compared to TOPEX dual-frequency TEC measurements (considered as truth) for a number of TOPEX sub-satellite tracks. For a 13.6 GHz altimeter, a Total Electron Content (TEC) of 1 TECU 10(exp 16) electrons/sq m corresponds to approximately 0.218 centimeters of range delay. A maximum expected TEC (at solar maximum or during solar storms) of 10(exp 18) electrons/sq m will create 22 centimeters of range delay. Compared with the TOPEX data, the PRISM predictions were generally accurate within the TECU when the sub-satellite track of interest passed within 300 to 400 km of the GPS TEC data or when the track passed through a night-time ionosphere. If neither was the case, in particular if the track passed through a local noon ionosphere, the PRISM values differed by more than 10 TECU and by as much as 40 TECU. The IRI-90 model, with no current ability to unseat GPS data, predicted TEC to a slightly higher error of 12 TECU. The performance of PRISM is very promising for predicting TEC and will prove useful for calibrating single frequency altimeter height measurements for ionospheric path delay. When adjusted to the GPS line-of-sight data the PRISM URSI empirical model predicted TEC over a day's period to within a global error of 8.60 TECU rms during a nighttime ionosphere and 9.74 TECU rms during the day. When adjusted to the GPS derived TEC grid, the PRISM parametrized model predicted TEC to within an error of 8.47 TECU rms for a nighttime ionosphere and 12.83 TECU rms during the day. However, the grid cannot be considered globally due to the lack of sufficient numbers of GPS stations and large latitude gaps in GPS data. It is the opinion of the authors that using the PRISM model and adjusting to the global sun-fixed TEC grid regenerated with a localized weighted interpolation offers the best possibility of meeting the 10 TECU global rms (or 2 cm at 13.6 GHz) ionosphere range correction accuracy requirement of TOPEX/Poseidon and should be the subject of further study. However, it is clear that the anticipated requirement of 34 TECU global rms for TOPEX/Poseidon Follow-On (corresponding to the TOPEX/Poseidon performance) can not be met with any realizable combination of existing models and data assimilation schemes.

Schreiner, William S.↗

A broad-band low-noise SIS receiver for submillimeter astronomy

A quasi-optical heterodyne receiver using a Pb-alloy superconductor-insulator-superconductor (SIS) tunnel junction as the detector and a planar logarithmic spiral antenna for the RF coupling is described, and its performance is compared with a the predicted performance of a theoretical model. Noise measurements were made in the laboratory at frequencies between 115 GHz and 761 GHz, yielding double-sideband noise temperatures ranging from 33 K to 1100 K. The receiver has also been used for astronomical spectroscopy on the Caltech Submillimeter Observatory (Mauna Kea, Hawaii) at 115, 230, 345, and 492 GHz.

Buttgenbach, Thomas H.↗

Review of measurements of the RF spectrum of radiation from lightning

A review is presented of the measurements reported in the literature of the spectrum of electromagnetic radiation from lightning in the frequency range from 1 kHz to 1 GHz. Measurements have been made either by monitoring the power received at individual frequencies using a narrow bandwidth recording device or by recording the transient (time dependent) radiation with a wide bandwidth device and then Fourier transforming the waveform to obtain a spectrum. Measurements of the first type were made extensively in the 1950's and 1960's and several composite spectra have been deduced by normalizing the data of different investigators to common units of bandwidth and distance. The composite spectra tend to peak near 5 kHz and then decrease roughly as 1/(frequency) up to nearly 100 MHz where scatter in the data make the behaviour uncertain. The spectrum obtained with measurements of the second type is similar. Recent experiments have extended the frequency range covered to several 10's of MHz and include spectra for return strokes, the stepped leader and for some intracloud processes. The spectrum of first return strokes obtained in this manner is very similar to the spectrum of the composite flash obtained from the narrowband measurements.

Radiation↗

Wide-Band Microwave Receivers Using Photonic Processing

In wide-band microwave receivers of a type now undergoing development, the incoming microwave signals are electronically preamplified, then frequency-up-converted to optical signals that are processed photonically before being detected. This approach differs from the traditional approach, in which incoming microwave signals are processed by purely electronic means. As used here, wide-band microwave receivers refers especially to receivers capable of reception at any frequency throughout the range from about 90 to about 300 GHz. The advantage expected to be gained by following the up-conversion-and-photonic-processing approach is the ability to overcome the limitations of currently available detectors and tunable local oscillators in the frequency range of interest. In a receiver following this approach (see figure), a preamplified incoming microwave signal is up-converted by the method described in the preceeding article. The frequency up-converter exploits the nonlinearity of the electromagnetic response of a whispering gallery mode (WGM) resonator made of LiNbO3. Up-conversion takes place by three-wave mixing in the resonator. The WGM resonator is designed and fabricated to function simultaneously as an electro-optical modulator and to exhibit resonance at the microwave and optical operating frequencies plus phase matching among the microwave and optical signals circulating in the resonator. The up-conversion is an efficient process, and the efficiency is enhanced by the combination of microwave and optical resonances. The up-converted signal is processed photonically by use of a tunable optical filter or local oscillator, and is then detected. Tunable optical filters can be made to be frequency agile and to exhibit high resonance quality factors (high Q values), thereby making it possible to utilize a variety of signal-processing modalities. Therefore, it is anticipated that when fully developed, receivers of this type will be compact and will be capable of both wide-band and narrowband signal processing. Thus, one compact receiver of this type would afford the functionality that, heretofore, could have been obtained only by use of multiple heterodyne microwave receivers.

Matsko, Andrey↗

Microwave Oscillators Based on Nonlinear WGM Resonators

Optical oscillators that exploit resonantly enhanced four-wave mixing in nonlinear whispering-gallery-mode (WGM) resonators are under investigation for potential utility as low-power, ultra-miniature sources of stable, spectrally pure microwave signals. There are numerous potential uses for such oscillators in radar systems, communication systems, and scientific instrumentation. The resonator in an oscillator of this type is made of a crystalline material that exhibits cubic Kerr nonlinearity, which supports the four-photon parametric process also known as four-wave mixing. The oscillator can be characterized as all-optical in the sense that the entire process of generation of the microwave signal takes place within the WGM resonator. The resonantly enhanced four-wave mixing yields coherent, phase-modulated optical signals at frequencies governed by the resonator structure. The frequency of the phase-modulation signal, which is in the microwave range, equals the difference between the frequencies of the optical signals; hence, this frequency is also governed by the resonator structure. Hence, further, the microwave signal is stable and can be used as a reference signal. The figure schematically depicts the apparatus used in a proof-of-principle experiment. Linearly polarized pump light was generated by an yttrium aluminum garnet laser at a wavelength of 1.32 microns. By use of a 90:10 fiber-optic splitter and optical fibers, some of the laser light was sent into a delay line and some was transmitted to one face of glass coupling prism, that, in turn, coupled the laser light into a crystalline CaF2 WGM disk resonator that had a resonance quality factor (Q) of 6x10(exp 9). The output light of the resonator was collected via another face of the coupling prism and a single-mode optical fiber, which transmitted the light to a 50:50 fiber-optic splitter. One output of this splitter was sent to a slow photodiode to obtain a DC signal for locking the laser to a particular resonator mode. The other output of this splitter was combined with the delayed laser signal in another 50:50 fiber-optic splitter used as a combiner. The output.of the combiner was fed to a fast photodiode that demodulated light and generated microwave signal. In this optical configuration, the resonator was incorporated into one arm of a Mach-Zehnder interferometer, which was necessary for the following reasons: It was found that when the output of the resonator was sent directly to a fast photodiode, the output of the photodiode did not include a measurable microwave signal. However, when the resonator was placed in an arm of the interferometer and the delay in the other arm was set at the correct value, the microwave signal appeared. Such behavior is distinctly characteristic of phase-modulated light. The phase-modulation signal had a frequency of about 8 GHz, corresponding to the free spectral range of the resonator. The spectral width of this microwave signal was less than 200 Hz. The threshold pump power for generating the microwave signal was about 1 mW. It would be possible to reduce the threshold power by several orders of magnitude if resonators could be made from crystalline materials in dimensions comparable to those of micro-resonators heretofore made from fused silica.

Maleki, Lute↗

A Modified NASA Team Sea Ice Algorithm for the Antarctic

A recent comparative study of the NASA Team and Bootstrap passive microwave sea ice algorithms revealed significantly different sea ice concentration retrievals in some parts of the Antarctic. The study identified potential reasons for the discrepancies including the influence of sea ice temperature variability on the Bootstrap retrievals and the influence of ice surface reflectivity on the horizontally polarized emissivity in the NASA Team retrievals. In this study, we present a modified version of the NASA Team algorithm which reduces the error associated with the use of horizontally polarized radiance data, while retaining the relative insensitivity to ice temperature variations provided by radiance ratios. By retaining the 19 GHz polarization as an independent variable, we also maintain a relatively large dynamic range in sea ice concentration. The modified algorithm utilizes the 19 GHz polarization (PR19) and both gradient ratios, GRV and GRH defined by (37V-19V)/(37V+19V) and (37H-19H)/(37H+19H), respectively, rather than just GRV used in the current NASA Team algorithm. A plot of GRV versus GRH shows that the preponderance of points lie along a quadratic curve, whereas those points affected by surface reflectivity anomalies deviate from this curve. This serves as a method of identifying the problems points. The 19H brightness temperature of these problem points is increased so they too fall along quadratic curve. Sea ice concentrations derived from AVHRR imagery illustrate the extent to which this method reduces the error associated with surface layering.

Cavalieri, Donald J.↗

High photon-phonon pair generation rate in a two-dimensional optomechanical crystal

Integrated optomechanical systems are a leading platform for manipulating, sensing, and distributing quantum information, but are limited by residual optical heating. Here, we demonstrate a two-dimensional optomechanical crystal (OMC) geometry with increased thermal anchoring and a mechanical mode at 7.4 GHz, well aligned with the operation range of cryogenic microwave hardware and piezoelectric transducers. The eight times better thermalization than current one-dimensional OMCs, large optomechanical coupling rates, g 0 /2π ≈ 880 kHz, and high optical quality factors, Q opt = 2.4 × 10 5 , allow ground-state cooling (n m = 0.32) of the acoustic mode from 3 K and entering the optomechanical strong-coupling regime. In pulsed sideband asymmetry measurements, we show ground-state operation (n m < 0.45) at temperatures below 10 mK, with repetition rates up to 3 MHz, generating photon-phonon pairs at ≈ 147 kHz. Our results extend optomechanical system capabilities and establish a robust foundation for future microwave-to-optical transducers with entanglement rates exceeding state-of-the-art superconducting qubit decoherence rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗