Solar PV Inverter Reactive Power Disaggregation and Control Setting Estimation
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This letter investigates a Branching Dueling Q-Network (BDQ) based online operation strategy for a microgrid with distributed battery energy storage systems (BESSs) operating under uncertainties. Additionally, the developed deep reinforcement learning (DRL) based microgrid online optimization strategy can achieve a linear increase in the number of neural network outputs with the number of distributed BESSs, which overcomes the curse of dimensionality caused by the charge and discharge decisions of multiple BESSs. Numerical simulations validate the effectiveness of the proposed method.
Understanding and distinguishing temporal patterns in time series data is essential for scientific discovery and decision-making. For example, in biomedical research, uncovering meaningful patterns in physiological signals can improve diagnosis, risk assessment, and patient outcomes. However, existing methods for time series pattern discovery face major challenges, including high computational complexity, limited interpretability, and difficulty in capturing meaningful temporal structures. Here, to address these gaps, we introduce a novel learning framework that jointly trains two Transformer models using complementary time series representations: shapelet-based representations to capture localized temporal structures and traditional feature engineering to encode statistical properties. The learned shapelets serve as interpretable signatures that differentiate time series across classification labels. Additionally, we develop a visual analytics system—SigTime—with coordinated views to facilitate exploration of time series signatures from multiple perspectives, aiding in useful insights generation. We quantitatively evaluate our learning framework on eight publicly available datasets and one proprietary clinical dataset. Additionally, we demonstrate the effectiveness of our system through two usage scenarios along with the domain experts: one involving public ECG data and the other focused on preterm labor analysis.
Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, this study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modeling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Here, the results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within 3% of measured values.
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) will undergo proton power upgrade (PPU), increasing the proton beam power from 1.4 MW to 2.8 MW. From 2.8 MW, 2.0 MW will go to the current First Target Station and the rest will go to the future Second Target Station (STS). The First Target Station uses a liquid mercury target that is contained in a 316L stainless steel vessel. The proton beam is pulsed at 60 Hz, with a pulse of about 0.7μs. When the proton beam hits the target, the intense energy deposition leads to a rapid rise in temperature in the mercury. This temperature rise creates pressure waves that propagate through the mercury and cause cavitation erosion. The power upgrade will cause stronger pressure waves that will further increase damage because of cavitation. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at 1.4 MW. However, at higher power, additional mitigation is necessary. Therefore, the 2 MW target vessel will be equipped with swirl bubblers and an additional gas injection port near the nose to inject more gas in the target. To develop a gas injection strategy and design, flow visualization in water with a transparent prototypical target (“visual target”) was performed. Bubble sizes and their spatial distribution in the flow loop are crucial to understanding the effectiveness of the bubbles in mitigating pressure waves. Bubbles were generated in the visual target under varied conditions of input pressures with helium and air. Images were captured using a high-speed camera at varied frame rates at different positions away from the swirl bubbler and different depths in the flow loop under varying lighting conditions. Initially, methods such as circular Hough transforms were applied after a series of images processing to obtain a general distribution of bubble sizes. Bubbles smaller than 500 μm are preferred to effectively mitigate the effect of pressure waves, which demands an accurate bubble detection and sizing system. Intelligent detection and identification of bubble sizes alleviate misdetection and improves accuracies. Employing neural networks, intelligent detection of bubble sizes and their distribution was developed and provides a robust alternative to traditional techniques. Human intervention was employed to label in-focus and out-of-focus bubbles in the set of training images. An object detection network using a pretrained convolutional neural network was created that extracted the features from the training images. Data augmentation was used to improve network accuracy through a random transformation of the original data.
Purpose: The authors are developing a computerized system for automated segmentation of ureters in CTU, referred to as combined model-guided path-finding analysis and segmentation system (COMPASS). Ureter segmentation is a critical component for computer-aided diagnosis of ureter cancer. Methods: COMPASS consists of three stages: (1) rule-based adaptive thresholding and region growing, (2) path-finding and propagation, and (3) edge profile extraction and feature analysis. With institutional review board approval, 79 CTU scans performed with intravenous (IV) contrast material enhancement were collected retrospectively from 79 patient files. One hundred twenty-four ureters were selected from the 79 CTU volumes. On average, the ureters spanned 283 computed tomography slices (range: 116–399, median: 301). More than half of the ureters contained malignant or benign lesions and some had ureter wall thickening due to malignancy. A starting point for each of the 124 ureters was identified manually to initialize the tracking by COMPASS. In addition, the centerline of each ureter was manually marked and used as reference standard for evaluation of tracking performance. The performance of COMPASS was quantitatively assessed by estimating the percentage of the length that was successfully tracked and segmented for each ureter and by estimating the average distance and the average maximum distance between the computer and the manually tracked centerlines. Results: Of the 124 ureters, 120 (97%) were segmented completely (100%), 121 (98%) were segmented through at least 70%, and 123 (99%) were segmented through at least 50% of its length. In comparison, using our previous method, 85 (69%) ureters were segmented completely (100%), 100 (81%) were segmented through at least 70%, and 107 (86%) were segmented at least 50% of its length. With COMPASS, the average distance between the computer and the manually generated centerlines is 0.54 mm, and the average maximum distance is 2.02 mm. With our previous method, the average distance between the centerlines was 0.80 mm, and the average maximum distance was 3.38 mm. The improvements in the ureteral tracking length and both distance measures were statistically significant (p < 0.0001). Conclusions: COMPASS improved significantly the ureter tracking, including regions across ureter lesions, wall thickening, and the narrowing of the lumen.
Purpose: Breast tissue composition is considered to be associated with breast cancer risk. This study aimed to develop a computer-aided classification (CAC) system to automatically classify echotexture patterns as heterogeneous or homogeneous using automated breast ultrasound (ABUS) images. Methods: A CAC system was proposed that can recognize breast echotexture patterns in ABUS images. For each case, the echotexture pattern was assessed by two expert radiologists and classified as heterogeneous or homogeneous. After neutrosophic image transformation and fuzzy c-mean clusterings, the lower and upper boundaries of the fibroglandular tissues were defined. Then, the number of hypoechoic regions and histogram features were extracted from the fibroglandular tissues, and the support vector machine model with the leave-one-out cross-validation method was utilized as the classifier. The authors’ database included a total of 208 ABUS images of the breasts of 104 females. Results: The accuracies of the proposed system for the classification of heterogeneous and homogeneous echotexture patterns were 93.48% (43/46) and 92.59% (150/162), respectively, with an overall Az (area under the receiver operating characteristic curve) of 0.9786. The agreement between the radiologists and the proposed system was almost perfect, with a kappa value of 0.814. Conclusions: The use of ABUS and the proposed method can provide quantitative information on the echotexture patterns of the breast and can be used to evaluate whether breast echotexture patterns are associated with breast cancer risk in the future.
Purpose: To develop an automated and scalable approach and identify temporal, spatial and dosimetric patterns of radiation damage of white matter (WM) fibers following partial brain irradiation. Methods: An automated and scalable approach was developed to extract DTI features of 22 major WM fibers from 33 patients with low-grade/benign tumors treated by radiation therapy (RT). DTI scans of the patients were performed pre-RT, 3- and 6-week during RT, and 1, 6 and 18 months after RT. The automated tractography analysis was applied to 198 datasets as: (1) intra-subject registration of longitudinal DTI, (2) spatial normalization of individual-patient DTI to the Johns Hopkins WM Atlas, (3) automatic fiber tracking regulated by the WM Atlas, and (4) segmentation of WM into 22 major tract profiles. Longitudinal percentage changes in fractional anisotropy (FA), and mean, axial and radial diffusivity (MD/AD/RD) of each tract from pre-RT were quantified and correlated to 95%, 90% and 80% percentiles of doses and mean doses received by the tract. Heatmaps were used to identify clusters of significant correlation and reveal temporal, spatial and dosimetric signatures of WM damage. A multivariate linear regression was further carried out to determine influence of clinical factors. Results: Of 22 tracts, AD/MD changes in 12 tracts had significant correlation with doses, especially at 6 and 18 months post-RT, indicating progressive radiation damage after RT. Most interestingly, the DTI-index changes in the elongated tracts were associated with received maximum doses, suggesting a serial-structure behavior; while short association fibers were affected by mean doses, indicating a parallel-structure response. Conclusion: Using an automated DTI-tractography analysis of whole brain WM fibers, we reveal complex radiation damage patterns of WM fibers. Damage in WM fibers that play an important role in the neural network could be associated with late neurocognitive function declines after brain irradiation. NIH NS064973.
Purpose: Changes in textural characteristics of diffuse optical spectroscopic (DOS) functional images, accompanied by alterations in their mean values, are demonstrated here for the first time as early surrogates of ultimate treatment response in locally advanced breast cancer (LABC) patients receiving neoadjuvant chemotherapy (NAC). NAC, as a standard component of treatment for LABC patient, induces measurable heterogeneous changes in tumor metabolism which were evaluated using DOS-based metabolic maps. This study characterizes such inhomogeneous nature of response development, by determining alterations in textural properties of DOS images apparent at early stages of therapy, followed later by gross changes in mean values of these functional metabolic maps. Methods: Twelve LABC patients undergoing NAC were scanned before and at four times after treatment initiation, and tomographic DOS images were reconstructed at each time. Ultimate responses of patients were determined clinically and pathologically, based on a reduction in tumor size and assessment of residual tumor cellularity. The mean-value parameters and textural features were extracted from volumetric DOS images for several functional and metabolic parameters prior to the treatment initiation. Changes in these DOS-based biomarkers were also monitored over the course of treatment. The measured biomarkers were applied to differentiate patient responses noninvasively and compared to clinical and pathologic responses. Results: Responding and nonresponding patients demonstrated different changes in DOS-based textural and mean-value parameters during chemotherapy. Whereas none of the biomarkers measured prior the start of therapy demonstrated a significant difference between the two patient populations, statistically significant differences were observed at week one after treatment initiation using the relative change in contrast/homogeneity of seven functional maps (0.001 < p < 0.049), and mean value of water content in tissue (p = 0.010). The cross-validated sensitivity and specificity of these parameters at week one of therapy ranged between 80%–100% and 67%–100%, respectively. Higher levels of statistically significant differences were exhibited at week four after start of treatment, with cross-validated sensitivities and specificities ranging between 80% and 100% for three textural and three mean-value parameters. The combination of the textural and mean-value parameters in a “hybrid” profile could better separate the two patient populations early on during a course of treatment, with cross-validated sensitivities and specificities of up to 100% (p = 0.001). Conclusions: The results of this study suggest that alterations in textural characteristics of DOS images, in conjunction with changes in their mean values, can classify noninvasively the ultimate clinical and pathologic response of LABC patients to chemotherapy, as early as one week after start of their treatment. This provides a basis for using DOS imaging as a tool for therapy personalization.
Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.
Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transformations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations.
Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transofrmations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations
SF-25-088 Coherent X-ray scattering techniques are critical for investigating the fundamental structural properties of materials at the nanoscale. While advancements have made these experiments more accessible, real-time analysis remains a significant bottleneck, often hindered by artifacts and computational demands. In scanning X-ray nanodiffraction microscopy, which is widely used to spatially resolve structural heterogeneities, this challenge is compounded by the convolution of the divergent beam with the sample’s local structure. To address this, we introduce DONUT (Diffraction with Optics for Nanobeam by Unsupervised Training), a physics-aware neural network designed for the rapid and automated analysis of nanobeam diffraction data. By incorporating a differentiable geometric diffraction model directly into its architecture, DONUT learns to predict crystal lattice strain and orientation in real-time. Crucially, this is achieved without reliance on labeled datasets or pre-training, overcoming a fundamental limitation for supervised machine learning in X-ray science. We demonstrate experimentally that DONUT accurately extracts all features within the data over 200 times more efficiently than conventional fitting methods.
Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Structural health monitoring of concrete structures aims to understand the current health condition of a structure based on heterogeneous measurements to produce high-confidence actionable information regarding structural integrity that supports operational and maintenance decisions. This ongoing research project is seeking to develop a probabilistic framework for health diagnosis and prognosis of aging concrete structures in a nuclear power plant that is subjected to physical, chemical, environment, and mechanical degradation. In this paper, experimental set up at Vanderbilt University’s Laboratory for Systems Integrity and Reliability is used to research effective combinations of full field techniques, which include infrared thermography, digital image correlation, and ultrasonic measurement. The full-field imaging data collected were processed using contour mapping technique to identify holes in a concrete slab. The techniques discussed and presented in this paper allow diagnosis of damage. The framework will enable plant operators to make risk informed decisions on the struc-tural integrity, remaining useful life, and performance of concrete structures.
This presentation offers a framework for classifying and identifying buildings using EO, Lidar, and GEOBIA.
This report serves as an addendum to the report 2015 Eastern Interconnect Baselining and Analysis Report (Amidan, Follum, and Freeman, 2015). This addendum report investigates the following: the impact of shorter record lengths and of adding a daily regularization term to the date/time models for angle pair measurements, additional development of a method to monitor the trend in phase angle pairs, the effect of changing the length of time to determine a baseline, when calculating atypical events, and a comparison between quantitatively discovered atypical events and actual events.
As tradit ional numerical computing has faced challenges, researchers have turned towards alternative computing approaches to reduce power - per - computation metrics and improve algorithm performance. Here, we describe an approach towards non - conventional computing that strengthens the connection between machine learning and neuroscience concepts. The Hardware Acceleration of Adaptive Neural Algorithms (HAANA) project ha s develop ed neural machine learning algorithms and hardware for applications in image processing and cybersecurity. While machine learning methods are effective at extracting relevant features from many types of data, the effectiveness of these algorithms degrades when subjected to real - world conditions. Our team has generated novel neural - inspired approa ches to improve the resiliency and adaptability of machine learning algorithms. In addition, we have also designed and fabricated hardware architectures and microelectronic devices specifically tuned towards the training and inference operations of neural - inspired algorithms. Finally, our multi - scale simulation framework allows us to assess the impact of microelectronic device properties on algorithm performance.