Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRAME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Comparison of Realizations of the Terrestrial Reference Frame

IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We compared the IGN and DGFI TRFs with a GSFC CALC/SOLVE TRF. WRMS position and velocity differences for the 40 most frequently observed sites were 2-3 mm and 0.3-0.4 mm/year. There was a scale difference of 0.39/0.09 ppb between the IGN/DGFI realizations and the GSFC solution. When we fixed positions and velocities to either the IGN or DGFI values in CALC/SOLVE solutions, the resulting EOP estimates were not significantly different from the estimates from a standard TRF solution.

Comparison↗

Modeling laser-plasma acceleration in the wakefield frame

A simulation of laser-plasma acceleration in the boosted frame of the wake, moving at near lightspeed. Space has contracted and time has stretched, separating events in time. Relatively few time steps are needed to model them, requiring less computer time.

43 PARTICLE ACCELERATORS↗

Building America Top Innovations 2012: Advanced Framing Systems and Packages

This Building America Top Innovations profile describes Building America research showing advanced 2x6, 24-inch on-center framing, single top plates, open headers, and 2-stud corners reduced board feet of lumber by more than 1,000 feet, cut energy use by 13%, and cut material and labor costs by more than $1,000 on a typical home.

advanced framing↗

SPC-3186 Rev 8 Reactor Support Frame and Outer Shield Build to Print Fabrication Specification

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of the Reactor Support Frame (RSF) and Outer Shield.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} and A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Framings of Spatial Graphs

In the theory of spatial graphs, we state and prove an analog of the theorem on the isotopy classification of framings of classical knots.

97 MATHEMATICS AND COMPUTING↗

Translational control of Nrf2 within the open reading frame

Highlights: •Identification of a novel Nrf2 translational repression mechanism. •The repressor is within the 3′ portion of the Nrf2 ORF. •The translation of Nrf2 or eGFP is reduced by the regulatory element. •The translational repression can be reversed with synonymous codon substitutions. •The molecular mechanism requires the mRNA sequence, but not the encoded amino acids. -- Abstract: Nuclear Factor Erythroid 2-Related Factor 2 (Nrf2) is a transcription factor that is essential for the regulation of an effective antioxidant and detoxifying response. The regulation of its activity can occur at transcription, translation and post-translational levels. Evidence suggests that under environmental stress conditions, new synthesis of Nrf2 is required – a process that is regulated by translational control and is not fully understood. Here we described the identification of a novel molecular process that under basal conditions strongly represses the translation of Nrf2 within the open reading frame (ORF). This mechanism is dependent on the mRNA sequence within the 3′ portion of the ORF of Nrf2 but not in the encoded amino acid sequence. The Nrf2 translational repression can be reversed with the use of synonymous codon substitutions. This discovery suggests an additional layer of control to explain the reason for the low Nrf2 concentration under quiescent state.

60 APPLIED LIFE SCIENCES↗

Alternative translation initiation from two in-frame start codons in DHX33 gene

Highlights: • DHX33 can be translated via leaky scanning. • The isoforms of DHX33 via leaky scanning have similar localization and functions. • Leaky scanning of DHX33 is conserved in human and in mouse. DHX33 has been shown to play key roles in promoting cell proliferation. We have previously found that DHX33 protein is a doublet. In this report, we discovered that DHX33 doublet is due to alternative translation initiation by two in-frame initiation codons. This is supported by studies from both cell lines and mouse models. DHX33 translation initiation from either AUG codon happens at equal efficiency. Short DHX33 protein has similar cellular location and functions with full-length DHX33. Our results suggest that leaky scanning normally occur in DHX33 mRNA translation, which may serve as a safeguard mechanism to ensure optimal DHX33 translation efficiency. This is the first report of DEAD/DEAH box proteins that can be regulated by alternative translation initiation.

60 APPLIED LIFE SCIENCES↗

Entropy–viscosity method for the single material Euler equations in Lagrangian frame

In this work, a new finite element method for solving the Euler equations in Lagrangian coordinates is proposed. The method is stabilized by adding artificial diffusion terms compatible with positivity of mass and internal energy, a minimum principle on the specific entropy, and all generalized entropy inequalities. Two options of first-order artificial diffusion are considered. One is in the spirit of the Eulerian based method (Guermond et al., 2011 [23, 22]; Zingan et al., 2013) and the other is similar to existing viscosity stabilizations in Lagrangian frame, e.g., Dobrev et al. (2012). The method is verified to be high-order for smooth solutions even with active viscosity terms. This is achieved by using high-order finite element spaces and an entropy-based viscosity stabilization that degenerates the first-order viscous terms. This stabilization automatically distinguishes smooth and singular regions. The formal accuracy and convergence properties of the proposed methods are tested on a series of benchmark problems. This is the first result extending the entropy–viscosity methodology to the Lagrangian hydrodynamics.

97 MATHEMATICS AND COMPUTING↗

Development of lean, efficient, and fast physics-framed deep-learning-based proxy models for subsurface carbon storage

In this work, we present deep-learning-based surrogate models for CCUS developed with four different algorithms and a physics-framed two-phase flow problem involving displacement of water by CO 2 . The deep-learning models were trained using 3D datasets describing the pressure plume, CO 2 saturation plume, and water extraction rate generated by numerical simulation. The hyperparameters defining the architecture of the neural networks were optimized to determine the slimmest network size and training parameters that give the most efficient performance at the least training cost. To develop a robust model that closely mimics the governing physical laws, the discretized form of the two-phase fluid transport equation was used to formulate the supervised deep-learning task. The algorithms investigated in this study predicted the data to above 95% accuracy, with the multi-layer perceptron model demonstrating the best performance by balancing training speed, prediction time, and prediction accuracy with lean network capacity. Furthermore, the surrogate models simultaneously predict reservoir pressure and CO 2 saturation in every grid block, including the surface well extraction rate and bottomhole pressure, at all simulation times for a given static model realization in just a few seconds on a standard desktop computer. A key outcome of this study is that limits can be placed on network design parameters to avoid over designing neural networks, with associated efficiencies in training and prediction times. This is very useful because large volumes of data may be generated in CCUS projects and over-design of neural network architectures imposes penalties that are antithetical to the goal of near-real time forecasting.

58 GEOSCIENCES↗

Reduction of Respiratory Liver Tumor Motion by Abdominal Compression in Stereotactic Body Frame, Analyzed by Tracking Fiducial Markers Implanted in Liver

Purpose: To investigate in a three-dimensional framework the effectiveness and reproducibility of reducing the respiratory motion of liver tumors using abdominal compression in a stereotactic body frame. Methods and Materials: A total of 12 patients with liver tumors, who were treated with stereotactic body radiotherapy, were included in this study. These patients had three gold fiducial markers implanted in the healthy liver tissue surrounding the tumor. Fluoroscopic videos were acquired on the planning day and before each treatment fraction to visualize the motion of the fiducial markers during free breathing and varying levels of abdominal compression. Software was developed to track the fiducial markers and measure their excursions. Results: Abdominal compression reduced the patient group median excursion by 62% in the craniocaudal and 38% in the anteroposterior direction with respect to the median free-breathing excursions. In the left-right direction, the median excursion increased 15% (maximal increase 1.6 mm). The median residual excursion was 4.1 mm in the craniocaudal, 2.4 mm in the anteroposterior, and 1.8 mm in the left-right direction. The mean excursions were reduced by compression to <5 mm in all patients and all directions, with two exceptions (craniocaudal excursion reduction of 20.5 mm to 7.4 mm and of 21.1 mm to 5.9 mm). The residual excursions reproduced well during the treatment course, and the craniocaudal excursions measured on the treatment days were never significantly ({alpha} = 0.05) greater than on the planning days. Fine tuning the compression did not considerably change the excursion on the treatment days. Conclusions: Abdominal compression effectively reduced liver tumor motion, yielding small and reproducible excursions in three dimensions. The compression level established at planning could have been safely used on the treatment days.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the Effectiveness of the Stereotactic Body Frame in Reducing Respiratory Intrafractional Organ Motion Using the Real-Time Tumor-Tracking Radiotherapy System

Purpose: To evaluate the effectiveness of the stereotactic body frame (SBF), with or without a diaphragm press or a breathing cycle monitoring device (Abches), in controlling the range of lung tumor motion, by tracking the real-time position of fiducial markers. Methods and Materials: The trajectories of gold markers in the lung were tracked with the real-time tumor-tracking radiotherapy system. The SBF was used for patient immobilization and the diaphragm press and Abches were used to actively control breathing and for self-controlled respiration, respectively. Tracking was performed in five setups, with and without immobilization and respiration control. The results were evaluated using the effective range, which was defined as the range that includes 95% of all the recorded marker positions in each setup. Results: The SBF, with or without a diaphragm press or Abches, did not yield effective ranges of marker motion which were significantly different from setups that did not use these materials. The differences in the effective marker ranges in the upper lobes for all the patient setups were less than 1mm. Larger effective ranges were obtained for the markers in the middle or lower lobes. Conclusion: The effectiveness of controlling respiratory-induced organ motion by using the SBF+diaphragm press or SBF + Abches patient setups were highly dependent on the individual patient reaction to the use of these materials and the location of the markers. They may be considered for lung tumors in the lower lobes, but are not necessary for tumors in the upper lobes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient ({Sigma}) and interfraction ({sigma}) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with {Sigma} = 1.1 mm and {sigma} = 0.8 mm. Considering only RCT setups <1mm (PFX action level) the mean 3D positioning displacement reduced to 1.3 mm, with {Sigma} = 0.9 mm and {sigma} = 0.4 mm. The largest contributing systematic uncertainty was in the superior-inferior direction (mean displacement = -0.5 mm; {Sigma} = 0.9 mm). The largest mean rotation was 0.6{sup o} in pitch. The mean 3D intrafraction motion was 0.4 {+-} 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

A new double time-of- ight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency- corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. As a result, this method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical investigation on lithium transport in the edge plasma of EAST real-time- Li-injection experiments in the frame of BOUT++

To study the transport of Li species in the plasma with real-time Li aerosol injection on EAST, a model has been developed by reducing Braginskii's equations, and implemented in the frame of BOUT++. The simulation results show that Li atoms propagate inwards since the Li injection, and their penetration depth depends on both the local plasma conditions along their path and initial injection velocity. It is also found that Li ions accumulate rapidly in the edge, and only a small fraction of Li species can transport cross the separatrix into the core. In the poloidal direction, Li ions drift swiftly downwards along the field lines, and transport much faster at the high field side than at the low field side. The interaction between background plasma and Li species plays a critical role in determining the edge plasma profile. It is found that real-time Li injection raises the plasma density in the pedestal region and reduces the plasma temperature, just as has been observed experimentally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗