Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Variable pin fin construction to facilitate compliant cold plates

A device can comprise a plurality of layers stacked and bonded on one another, wherein at least one layer of the plurality of layers comprises: a first active region comprising first pin portions positioned in a first planar arrangement; and a second active region comprising second pin portions positioned in a second planar arrangement, wherein the second planar arrangement is different from the first planar arrangement. The device can also comprise a conformable layer adjacent to at least one of the plurality of layers.

Schultz, Mark Delorman↗

Sensitivity study on the fin effect of thermocouple mounted on the heated surface under film boiling condition

In the reactivity-initiated accident (RIA) scenario, right after the power burst with the occurrence of departure from nucleate boiling (DNB), the cladding temperature quickly reaches its maximum and is maintained in a steady film boiling regime. Then, under limited heat transfer performance of film boiling, the local cooling effect by the thermocouple wire may not be neglected. A computational model is developed to estimate the local cooling effect of the thermocouple wire mounted on the cladding surface under film boiling condition. The model predicts the temperature profile along the cladding surface as physically expected and is verified against the benchmark problem. Sensitivity studies reveal the significant effects of the thickness of vapor film layer and the diameter of thermocouple on the temperature drop near the thermocouple, for they increase the heat transfer area to the liquid water region. The impact of film boiling heat transfer coefficient, however, is not significant, as the primary heat transfer mechanism near the thermocouple is the heat conduction to the wire. Future study will include the contribution of radiative heat transfer between the cladding surface and the vapor film layer, as well as a transient power history which represents an actual RIA scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Review of Modeling Approaches for Predicting Frost Growth and Defrosting on Tube-Fin Heat Exchangers: Preprint

Frost formation and growth on the evaporator surface is a common process that deteriorates the air-refrigerant heat transfer and restricts airflow. This degrades the performance of the vapor compression system by increasing temperature lift and air-side pressure drop. To accurately predict these effects during coil frosting, as well as the energy use and duration of the defrost process, there is a need to estimate the heat and mass transfer, momentum transport, and solid-liquid and liquid-vapor phase change. Therefore, in the past few decades, continuous effort has been made to model frosting and defrosting processes using approaches ranging from empirical correlations to computational fluid dynamic models. To provide a clearer overview for researchers, engineers, and manufacturers in this field, this paper provides a comprehensive literature review for frosting and defrosting models. The paper begins with theoretical background of frost formation and defrost processes, and then reviews the common modeling approaches in literature and their underlying assumptions when trying to account for various physical phenomenon. Based on the literature review, the most critical modeling effort for frost formation is the determination of frost densification rate and frost growth rate. Various methods to predict these two parameters are reviewed. Empirical correlations commonly used for frost density and thermal conductivity are presented and compared. For the defrost process, various multi-stage models have been proposed with different assumptions. Some assume the presence of air gap between the tube wall and the frost, while others consider the melted frost flow due to gravity. We also review physics-based and empirical approaches to integrate defrost models into heat pump models. We conclude by identifying research gaps and providing recommendations.

defrost↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Brush/Fin Thermal Interfaces

Brush/fin thermal interfaces are being developed to increase heat-transfer efficiency and thereby enhance the thermal management of orbital replaceable units (ORUs) of electronic and other equipment aboard the International Space Station. Brush/fin thermal interfaces could also be used to increase heat-transfer efficiency in terrestrial electronic and power systems. In a typical application according to conventional practice, a replaceable heat-generating unit includes a mounting surface with black-anodized metal fins that mesh with the matching fins of a heat sink or radiator on which the unit is mounted. The fins do not contact each other, but transfer heat via radiation exchange. A brush/fin interface also includes intermeshing fins, the difference being that the gaps between the fins are filled with brushes made of carbon or other fibers. The fibers span the gap between intermeshed fins, allowing heat transfer by conduction through the fibers. The fibers are attached to the metal surfaces as velvet-like coats in the manner of the carbon fiber brush heat exchangers described in the preceding article. The fiber brushes provide both mechanical compliance and thermal contact, thereby ensuring low contact thermal resistance. A certain amount of force is required to intermesh the fins due to sliding friction of the brush s fiber tips against the fins. This force increases linearly with penetration distance, reaching ~1 psi (~6.9 kPa) for full 2-in. (5.1 cm) penetration for the conventional radiant fin interface. Removal forces can be greater due to fiber buckling upon reversing the sliding direction. This buckling force can be greatly reduced by biasing the fibers at an angle perpendicularly to the sliding direction. Means of containing potentially harmful carbon fiber debris, which is electrically conductive, have been developed. Small prototype brush/fin thermal interfaces have been tested and found to exhibit temperature drops about onesixth of that of conventional meshing-fin thermal interface, when fabricated as a retrofit. In this case, conduction through the long, thin metal fins themselves becomes a thermal bottleneck. Further improvement could be made by prescribing aluminum fins to be shorter and thicker than those of the conventional meshing-fin thermal interfaces; the choice of height and thickness would be optimized to obtain greater overall thermal conductance, lower weight, and lower cost.

Knowles, Timothy R.↗

Subsonic Aerodynamic Characteristics of a Circular Body Earth-to-Orbit Vehicle

A test of a generic reusable earth-to-orbit transport was conducted in the 7- by 10-Foot high-speed tunnel at the Langley Research Center at Mach number 0.3. The model had a body with a circular cross section and a thick clipped delta wing as the major lifting surface. For directional control, three different vertical fin arrangements were investigated: a conventional aft-mounted center vertical fin, wingtip fins, and a nose-mounted vertical fin. The configuration was longitudinally stable about the estimated center-of-gravity position of 0.72 body length and had sufficient pitch-control authority for stable trim over a wide range of angle of attack, regardless of fin arrangement. The maximum trimmed lift/drag ratio for the aft center-fin configuration was less than 5, whereas the other configurations had values of above 6. The aft center-fin configuration was directionally stable for all angles of attack tested. The wingtip and nose fins were not intended to produce directional stability but to be active controllers for artificial stabilization. Small rolling-moment values resulted from yaw control of the nose fin. Large adverse rolling-moment increments resulted from tip-fin controller deflection above 13 deg angle of attack. Flow visualization indicated that the adverse rolling-moment increments were probably caused by the influence of the deflected tip-fin controller on wing flow separation.

Lepsch, Roger A., Jr.↗

Final Report: Use of Graphite Foam as a Thermal Performance Enhancement of Heavy Hybrid Propulsion Systems

Oak Ridge National Laboratory's graphite foam has the potential to be used as a heat exchanger for the Army's Future Combat System Manned Ground Vehicle and thus has the potential to improve its thermal performance. The computational fluid dynamics (CFD) program FLOW3D was used to develop a new CFD model for the graphite foam to be used in the development of a proper heat exchanger. The program was calibrated by first measuring the properties of the solid foams and determining the parameters to be used in the CFD model. Then the model was used to predict within 5% error the performance of finned foam heat sinks. In addition, the f factors and j factors commonly used to predict pressure drop and heat transfer were calculated for both the solid and finned structures. There was some evidence that corrugating the foams would yield higher j/f ratios than state of the art heat exchangers, confirming previously measured data. Because the results show that the CFD model was validated, it is recommended that the funding for Phases 2 through 5 be approved for the design of both the finned heat exchanger using tubes and round fin structures and the solid foam design using corrugated foams. It was found that the new CFD model using FLOW3D can predict both solid foam heat transfer and finned foam heat transfer with the validated model parameters. In addition, it was found that the finned foam structures exhibited j/f ratios that indicate that significant heat transfer is occurring within the fin structures due to aerodynamically induced flow, which is not present in solid aluminum fin structures. It is possible that the foam surfaces can act as turbulators that increase heat transfer without affecting pressure drop, like the vortex generators seen in state of the art heat exchangers. These numbers indicate that the foam can be engineered into an excellent heat exchanger. It was also found that corrugating the solid foams would increase the j/f ratio dramatically, allowing the solid foams to compete directly with standard heat exchangers. Although corrugated L1 foam samples have not been produced (attempts are under way), it is possible that their j/f ratio can be even higher than those of the finned structures.

33 ADVANCED PROPULSION SYSTEMS↗

Investigation of Ejection Releases of an MB-1 Rocket from a 0.04956-Scaled Model of the Convair F-106A Airplane at Several Mach Numbers and Simulated Altitudes

As a continuation of an investigation of the ejection release characteristics of an internally carried MB-1 rocket in the Convair F-106A airplane, fin modifications at additional Mach numbers and simulated altitudes have been studied in the 27- by 27-inch preflight jet of the Langley Pilotless Aircraft Research Station at Wallops Island, Va. The MB-1 rocket was ejected with fins open, fins closed, fins closed with a shroud around the fins, and fins folded with a "boattail" placed in between the fins. Dynamically scaled models (0.0^956 scale) were tested at simulated altitudes of 12,000, 18,850, and 27,500 feet at subsonic Mach numbers and at 18,850, 27,500, and 40,000 feet for Mach numbers of 1-39, 1-59, and 1.98. Successful ejections can be obtained for over 10 store diameters from release point by the use of a shroud around the folded fins with the proper ejection velocity and nose-down pitching moment at release. In one case investigated it was found desirable to close off the front one-third of the bomb bay. It appeared that the fins should be opened after release and within 5 "to 6 rocket diameters if no modifications are made on the rocket. An increase in fuselage angle of attack caused higher nose-up pitch rates after release.

Lee, J. B.↗

Subsonic aerodynamic characteristics of the HL-20 lifting-body configuration

The HL-20 is proposed as a possible future manned spacecraft. The configuration consists of a low-aspect-ratio body with a flat undersurface. Three fins (a small centerline fin and two outboard (tip) fins set at a dihedral angle of 50 deg) are mounted on the aft body. The control system consists of elevon surfaces on the outboard fins, a set of four body flaps on the upper and lower aft body, and an all-movable center fin. Both the elevons and body flaps were capable of trimming the model to angles of attack from -2 deg to above 20 deg. The maximum trimmed lift-drag ratio was 3.6. Replacing the flat-plate tip fins with airfoil tip fins increased the maximum trimmed lift-drag ratio to 4.2. The elevons were effective as a roll control, but they produced about as much yawing moment as rolling moment because of the tip-fin dihedral angle. The body flaps produced less rolling moment than the elevons and only small values of yawing moment. A limited investigation of the effect of varying tip-fin dihedral angle indicated that a dihedral angle of 50 deg was a reasonable compromise for longitudinal and lateral stability, longitudinal trim, and performance at subsonic speeds.

Ware, George M.↗

A Method for Prevention of Screaming in Rocket Engines

Lateral and longitudinal combustion-pressure oscillations that occurred in screaming combustion of a 1000-pound-thrust rocket engine using white fuming nitric acid and JP-4 fuel as propellants were successfully prevented by means of longitudinal fins in the combustion chamber. Fin position was critical, and complete attenuation was achieved only when the fins were located in a zone approximately 8 to 16 inches from the injector. Fins located in other zones, that is, near the injector or far downstream from the injector, did not stop the oscillations. When oscillations occurred in finned chambers, the longitudinal mode seemed more dominant than the lateral mode; in chambers without fins, the lateral mode tended to be dominant. The lateral oscillation was distorted and its intensity diminished by the fins. Fins, however, did not affect the frequencies; the longitudinal frequency varied inversely with chamber length, and lateral frequencies varied only slightly from an average of 6000 cycles per second.

ROCKET ENGINE NOISE↗

Phenotype anchoring in zebrafish reveals a potential role for matrix metalloproteinases (MMPs) in tamoxifen's effects on skin epithelium

The zebrafish is a powerful alternative model used to link phenotypes with molecular effects to discover drug mode of action. Using a zebrafish embryo-larval toxicity bioassay, we evaluated the effects of tamoxifen — a widely used anti-estrogen chemotherapeutic. Zebrafish exposed to ≥ 10 μM tamoxifen exhibited a unique necrotic caudal fin phenotype that was rapidly induced regardless of developmental life-stage when treatment was applied. To define tamoxifen's bioactivity resulting in this phenotype, targeted gene expression was used to evaluate 100 transcripts involved in tissue remodeling, calcium signaling, cell cycle and cell death, growth factors, angiogenesis and hypoxia. The most robustly misregulated transcripts in the tail were matrix metalloproteinases mmp9 and mmp13a, induced 127 and 1145 fold, respectively. Expression of c-fos, c-jun, and ap1s1 were also moderately elevated (3–7 fold), consistent with AP-1 activity — a transcription factor that regulates MMP expression. Immunohistochemistry confirmed high levels of induction for MMP13a in affected caudal fin skin epithelial tissue. The necrotic caudal fin phenotype was significantly attenuated or prevented by three functionally unique MMP inhibitors: EDTA (metal chelator), GM 6001 (broad MMP inhibitor), and SR 11302 (AP-1 transcription factor inhibitor), suggesting MMP-dependence. SR 11302 also inhibited induction of mmp9, mmp13a, and a putative MMP target, igfbp1a. Overall, our studies suggest that tamoxifen's effect is the result of perturbation of the MMP system in the skin leading to ectopic expression, cytotoxicity, and the necrotic caudal fin phenotype. These studies help advance our understanding of tamoxifen's non-classical mode of action and implicate a possible role for MMPs in tissues such as skin. - Highlights: • Tamoxifen rapidly induced a unique necrotic caudal fin phenotype in zebrafish. • Apoptosis co-localized temporally and spatially in the necrotic tail. • The necrotic fin phenotype was p53, GPER and ER independent. • The necrotic fin phenotype was dependent on ectopic MMP induction and activity in the skin. • The necrotic fin phenotype occurred at concentrations exceeding anti-estrogenic effects.

60 APPLIED LIFE SCIENCES↗

National Ignition Facility. Facility and Infrastructure Systems Maintenance Plan

Ensuring the reliability of the NIF, including its support systems, laser systems, target diagnostic systems, and utilities, is essential to the availability of the NIF in its support of NNSA missions. NIF is a key capability in the DOE Stockpile Stewardship Program and supports high energy physics experiments for nuclear weapons, energy, and astrophysics applications. High system reliability provides opportunities for shots and scientific discoveries with opportunities to enhance and upgrade capabilities. This Maintenance Plan (MP) identifies the policies and procedures used to perform and support asset management of the NIF Facility and Infrastructure Systems (FInS), NIF Lasers & Alignment (LASE), NIF Target Experimental Operations (TOPS), NIF Target Area Science and Engineering (TASE), and NIF&PS Control Systems (NCS). The FInS systems include the facility, HVAC, contamination control, beampath, and Line Replaceable Units (LRUs) as well as utilities which create the beampath environments, such as vacuum, argon, or clean dry air. The LASE systems are Programmatic systems which include laser diagnostics, alignment, power conditioning, pulsed power, and input laser systems. The TOPS and TASE systems are also Programmatic systems which include target and diagnostic delivery systems and positioners, many different insertable and fixed target diagnostics, and cryogenic and target gas fill systems. Finally, the NCS systems include both software and hardware for industrial and shot operation control systems. Policies governing administrative and operational practices related to maintenance of FInS, LASE, TOPS, TASE, and NCS systems are described in this plan. In addition, the plan provides processes and procedures for managing, tracking, and documenting the work. This document, the NIF Operations Management Plan, NIF-5020544 (Ref. 1), and NIF Shot Operations Plan, NIF-5018506 (Ref. 2), together satisfy the requirements of the Conduct of Operations. Duties, responsibilities, and reporting requirements of the various positions associated with FInS, LASE, and TOPS maintenance are detailed in this plan. The FInS systems include both Real Property systems with asset management requirements specified in DOE Order 430.1C (Ref. 3) and Programmatic systems. In addition, for FInS, there is a list of the System Level Maintenance Plans (SLMPs) in NIF-1007419198 (Ref. 4) which provide the system descriptions and maintenance plan and schedule. In addition, the list includes the Reliability Centered Maintenance (RCM) and Experience Centered Maintenance (ECM) evaluations that have been performed for applicable FInS systems as well as reliability criticality per Section 3.5. The -AM version of the NIF Maintenance Plan focuses on the reliability program for FInS, LASE, TOPS, TASE, and NCS within the context of the overall NIF Reliability, Availability, and Maintainability (RAM) program and incorporates changes since the -AL version from August 2011 and has been updated to be fully consistent with the updates to Ref. 1. It also includes asset management considerations, updates to the Work Order (WO) process within the NIF Computerized Maintenance Management System (CMMS) which is EAM infor® System Maintenance and Reliability Tracking (SMaRT) (Ref. 5), and updates to metrics and key performance indicators (KPIs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aerodynamic characteristics of a hypersonic research airplane concept having a 70 deg swept double-delta wing at Mach number 0.2

A wind-tunnel of the static longitudinal, lateral and directional stability characteristics of a hypersonic research airplane concept having a 70 deg swept double-delta wing was conducted in the Langley low-turbulence pressure tunnel. The configuration variables included wing planform, tip fins, center fin, and scramjet engine modules. A mach number of 0.2 was investigated over a Reynolds number (based on fuselage length) range of 2,200,000 to 19.75 x 1,000,000 (with a majority of tests at 10.0 x 1,000,000. Tests were conducted through an angle-of-attack range from about -2 deg to 34 deg at angles of sideslip of 0 deg to 5 deg, and at elevon deflection of 0 deg, -5 deg, -10 deg, -15 deg, and -20 deg. The drag coefficient of the integrated scramjet engine appears relatively constant with Reynolds number at the test Mach number of 0.2. Mild pitch-up was exhibited by the models equipped with tip fins. The forward delta, a highly swept forward portion of the wing, was destabilizing. The center fin model has a higher trimmed maximum lift-drag ratio and a wider trim lift and angle-of-attack range than the tip fin model. Both the tip fin models and center fin models exhibited positive dihedral effect and positive directional stability. Roll control was positive for the tip fin model, but yaw due to roll control was unfavorable.

Penland, J. A.↗