Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Atmospheric neutrons

Contributions to fast neutron measurements in the atmosphere are outlined. The results of a calculation to determine the production, distribution and final disappearance of atmospheric neutrons over the entire spectrum are presented. An attempt is made to answer questions that relate to processes such as neutron escape from the atmosphere and C-14 production. In addition, since variations of secondary neutrons can be related to variations in the primary radiation, comment on the modulation of both radiation components is made.

Korff, S. A.↗

Irradiation tests in BR2 of miniature fission chambers in pulse, Campbelling and current mode

The FNDS system ('Fast Neutron Detection System') for the on-line in-pile detection of the fast neutron flux in the presence of a significant thermal neutron flux and a high gamma dose rate is being developed in the framework of the SCK.CEN-CEA Laboratoire Commun. The system has been patented in 2008. The system consists of a miniature Pu-242 fission chamber as main detector, complemented by a U-235 fission chamber or a rhodium Self-Powered Neutron Detector (SPND) for thermal neutron flux monitoring and a dedicated acquisition system that also takes care of the processing of the signals from both detectors to extract fast neutron flux data. This paper describes a FNDS qualification experiment in the SCK.CEN BR2 reactor, with experimental results on a large set of fission chambers in current and Campbelling mode. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of damage induced by heavy neutron irradiation on multilayered {sup 6}LiF-single crystal chemical vapor deposition diamond detectors

High performance neutron detectors sensitive to both thermal and fast neutrons are of great interest to monitor the high neutron flux produced, e.g., by fission and fusion reactors. An obvious requirement for such an application is neutron irradiation hardness. This is why diamond based neutron detectors are currently under test in some of these facilities. In this paper the damaging effects induced in chemical vapor deposition (CVD) diamond based detectors by a neutron fluence of approx2x10{sup 16} neutrons/cm{sup 2} have been studied and significant changes in spectroscopic, electrical, and optical properties have been observed. The detectors are fabricated using high quality synthetic CVD single crystal diamond using the p-type/intrinsic/Schottky metal/{sup 6}LiF layered structure recently proposed by Marinelli et al. [Appl. Phys. Lett. 89, 143509 (2006)], which allows simultaneous detection of thermal and fast neutrons. Neutron radiation hardness up to at least 2x10{sup 14} n/cm{sup 2} fast (14 MeV) neutron fluence has been confirmed so far [see Pillon et al., (Fusion Eng. Des. 82, 1174 (2007)]. However, at the much higher neutron fluence of approx2x10{sup 16} neutrons/cm{sup 2} damage is observed. The detector response to 5.5 MeV {sup 241}Am alpha-particles still shows a well resolved alpha-peak, thus confirming the good radiation hardness of the device but a remarkable degradation and a significant instability with time of charge collection efficiency and energy resolution arise. Symmetric, nearly Ohmic I-V (current-voltage) characteristics have been recorded from the metal/intrinsic/p-doped diamond layered structure, which before neutron irradiation acted as a Schottky barrier diode with a strong rectifying behavior. The nature and the distribution of the radiation induced damage have been deeply examined by means of cathodoluminescence spectroscopy. A more heavily damaged area into the intrinsic diamond at the same position and with the same extension of the {sup 6}LiF layer has been found, the increased damage being ascribed to the highly ionizing particles produced in the {sup 6}LiF layer by thermal neutrons through the nuclear reaction {sup 6}Li(n,alpha)T.

36 MATERIALS SCIENCE↗

SU-E-T-108: Development of a Novel Clinical Neutron Dose Monitor for Proton Therapy Based On Twin TLD500 Chips in a Small PE Moderator

Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:C (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.

07 ISOTOPE AND RADIATION SOURCES↗

An alternative calibration method for counting P-32 reactor monitors

Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it can be performed regardless of the characterization of the exposure environment. Count rates produced by sulfur pellets are correlated to the measured quantity of separated {sup 32}P. A posteriori spectral and cross section determination can be used to correlate the quantity of phosphorus back to a neutron fluence in a reference field. This paper outlines a method for the setup, calibration, and use of the detector systems, {sup 32}P sample preparation, and analysis of the beta spectrum. An uncertainty analysis and comparison to ASTM E265 is also included. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the neutron induced reactions on 235 U from 2.25 keV up to 30 MeV

An evaluation of fast neutron induced reactions on 235 U is performed in the 2.25 keV–30 MeV incident energyrangewiththecodeEMPIRE–3.2Malta,combinedwithselectedexperimentaldata.Thereactionmodelincludes a dispersive optical model potential (RIPL 2408) that couples seven levels of the ground-state rotational band and a triple-humped fission barrier with absorption in the wells described within the optical model for fission. EGSM nuclear level densities are used in Hauser-Feshbach calculations of the compound-nuclear decay. The starting values for the modelparameters are retrievedfrom the RIPL-3 data-base. Excellentagreementis achievedwithavailable experimental data for neutron emission, neutron capture and fission, which gives confidence that the quantities for which there is no experimental information are also predicted accurately. In the fast neutron region of the evaluated file, the fission cross section is taken from Neutron Standards, and neutron capture includes fluctuations observed in recent experiments. Other channels are taken directly from model calculations. New evaluation is validated against ICSBEP criticality benchmarks with fast neutron spectra with excellent results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of muon-induced high-energy neutrons from rock in an underground Gd-doped water detector

In this paper, we present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results with the expected rate of correlated neutron captures arising from high-energy neutrons incident on the outside of the WATCHBOY shield, predicted by a hybrid FLUKA/GEANT4-based simulation. The incident neutron energy distribution used in the simulation was measured by a fast neutron spectrometer, the 1.8-ton Multiplicity and Recoil Spectrometer (MARS) detector, at the same depth. We nd that the measured detection rate of two correlated neutrons is consistent with that predicted by simulation. The result lends additional confidence in the detection technique used by MARS, and therefore in the MARS spectra as measured at three different depths. Confirmation of the fast neutron flux and spectrum is important as it helps validate the scaling models used to predict the fast neutron fluxes at different overburdens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A study of radiation damage effects on the magnetic structure of bulk Iron

Defects, defect interactions, and defect dynamics in solids created by fast neutrons are known to have significant impact on the performance and lifetime of structural materials. A fundamental understanding of the radiation damage effects in solids is therefore of great importance in assisting the development of improved materials - materials with ultrahigh strength, toughness, and radiation resistance. In this presentation, we show our recent theoretical investigation on the magnetic structure evolution of bulk iron in the region of the radiation defects. We applied a linear scaling ab-initio method based on density functional theory with local spin density approximation, namely the locally self-consistent multiple scattering method (LSMS), to the study of magnetic moment distributions in a cascade at the damage peak and for a series of time steps as the interstitials and vacancies recombined. Atomic positions correspond to those in a low energy cascade in a 10|000 atom sample, in which the primary damage state and the evolution of all defects produced were simulated using molecular dynamics with empirical, embedded-atom inter-atomic potentials. We will discuss how a region of affected moments expands and then recedes in response to a cascade evolution.

36 MATERIALS SCIENCE↗

SENSITIVITY EVALUATION OF THE DAILY THERMAL PREDICTIONS OF THE AGR-2 EXPERIMENT IN THE ADVANCED TEST REACTOR

A temperature sensitivity evaluation has been performed for the AGR-2 fuel experiment on an individual capsule. A series of cases were compared to a base case by varying different input parameters into the ABAQUS finite element thermal model. These input parameters were varied by ±10% to show the temperature sensitivity to each parameter. The most sensitive parameters are the outer control gap distance, heat rate in the fuel compacts, and neon gas fraction. Thermal conductivity of the fuel compacts and thermal conductivity of the graphite holder were in the middle of the list for sensitivity. The smallest effects were for the emissivities of the stainless steel and graphite, along with gamma heat rate in the non-fueled components. Sensitivity calculations were also performed varying with fast neutron fluence, showing a general temperature rise with an increase in fast neutron fluence. This is a result of the control gas gap becoming larger due to the graphite holder shrinkage with neutron damage. A smaller sensitivity is due to the thermal conductivity of the fuel compacts and graphite holder decreasing with fast neutron fluence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Neutron and Muon Fluxes 100~m Underground with the SciBath Detector

The SciBath detector is an 80 liter liquid scintillator detector read out by a three dimensional grid of 768 wavelength-shifting fibers. Initially conceived as a fine-grained charged particle detector for neutrino studies that could image charged particle tracks in all directions, it is also sensitive to fast neutrons (15-200 MeV). In fall of 2011 the apparatus performed a three month run to measure cosmic-induced muons and neutrons 100~meters underground in the FNAL MINOS near-detector area. Data from this run has been analyzed and resulted in measurements of the cosmic muon flux as \num{0.80\pm0.04}~\si{\m^{-2}\s^{-1}}, the cosmogenic fast neutron flux as \num{1.5\pm1.4e-2}~\si{\m^{-2}\s^{-1}}, and the neutron production rate from muon spallation in liquid scintillator as \num{3.8\pm3.2e-4}~$n/\mu$~\si{(\g\per\cm^2)^{-1}}. Additionally, the cosmic muon angular distribution and neutron energy distribution have been measured. These results can be extrapolated to future measurements of fast-neutron backgrounds at other underground facilities. This thesis presents a summary of the physics relevant to underground muons and fast neutrons, the SciBath detector, the analysis methodology that was used for the results presented, and comparisons between our results and those of other experiments and simulations

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of Shielding Material Configurations Using NMIS Imaging

The Nuclear Materials Identification System (NMIS) uses fast neutron tomographic imaging to nonintrusively examine the interior structure of shielded objects. The pixel values in such images represent the attenuation coefficients of the time and directionally tagged fast neutrons from a deuterium-tritium (DT) neutron generator. The reconstruction techniques use either a filtered back projection or a maximum likelihood expectation maximization algorithm. As a first test of the capabilities of these reconstruction techniques to correctly identify individual parts inside of an object, fast neutron imaging was used to identify the regions of shielding surrounding a depleted uranium casting from a library of possible parts. The shielding consisted of multiple regions of common materials such as steel, lead, aluminum, and polyethylene. First, the full object was imaged, and then each of the individual parts was imaged. Several additional parts that were not present in the original object were also imaged to form a library. The individual parts were compared to the full object, and the correct ones were identified using three different methods. These methods included a visual match, an iterative fit of each part, and a mathematical test comparing the sum of squared errors. The successful results demonstrate an initial application of matching. This suggests that it should be possible to implement more sophisticated matching techniques using automated pixel-by-pixel comparison methods in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated Fuel Qualification of Fast Modular Reactor Fuel in a Thermal Reactor: Modeling and Simulation Paired with Irradiation Testing

The accelerated fuel qualification (AFQ) methodology is applied by simulating accelerated fuel tests of the General Atomics Electromagnetic Systems’ fuel system for its 44-MW(electric) gas-cooled, fast-spectrum fast modular reactor (FMR). This fuel is comprised of UO 2 pellets in SiGA® cladding, a silicon carbide ceramic matrix composite. Fast reactors, like the FMR, offer many benefits, including high fuel utilization and flexibility, but may require a lengthy material design process if tests are performed using fast neutron irradiation alone. A thermal neutron irradiation can instead be used to rapidly test how well key components of the current material models extend to high burnup. Thermal neutrons produce a different radial power distribution within the pin than fast neutrons. However, the temperature and burnup values for the two neutron types are comparable, and the differences between the simulated fuel responses are relatively small, demonstrating the weak sensitivity of the physics-based fuel model calculations on the neutron type and the irradiation rate. Furthermore, the deformation of the SiGA cladding saturates after about 1 displacement per atom for both neutron spectra. In an accelerated fuel test, the irradiation time required to reach the target fuel burnup can be reduced by a factor of 3 by using a small rodlet with a 45% smaller pellet diameter while maintaining the same linear power. Therefore, the time for data collection up to high burnup can be significantly reduced while maintaining the same temperature profile, which largely determines the material response. Tests of fuel rodlets of standard and compact size will be carried out in the Idaho National Laboratory’s Advanced Test Reactor (ATR), including full size and compact rodlets with varying gap sizes. By applying physics-based mechanistic modeling and simulation in accordance with the AFQ methodology, this type of compact rodlet testing in a thermal test reactor captures the necessary phenomena to test fuel material models up to high burnup and to simulate the expected impact of fast neutron radiation on the fuel in FMR operations. Finally, this approach to testing fast reactor fuels in existing thermal test reactors, paired with advanced physics-based mechanistic modeling and simulation, is expected to be applicable to a range of advanced fuels and will decrease the overall fuel qualification timeframe from decades to years.

Advanced test reactor (ATR)↗

MECHANICAL BEHAVIOUR OF CYANATE ESTER/EPOXY BLENDS AFTER REACTOR IRRADIATION TO HIGH NEUTRON FLUENCES

The mechanical strength of conventional epoxy resins drops dramatically after irradiation to a fast neutron fluence of 1x10{sup 22} m{sup -2} (E>0.1 MeV). Recent results demonstrated that cyanate ester/epoxy blends were not affected at this fluence level. The aim of this study is to investigate the performance potential of these blends at higher fluence levels without significant degradation of their mechanical properties. Short-beam shear as well as static tensile tests were carried out at 77 K prior to and after irradiation to fast neutron fluences of up to 4x10{sup 22} m{sup -2} (E>0.1 MeV) in the TRIGA reactor at ambient temperature (340 K). In addition, load controlled tension-tension fatigue measurements were performed, in order to simulate the pulsed operation conditions of a tokamak. Initial results show that only a small reduction of the mechanical strength under static and dynamic load is observed at a fast neutron fluence of 2x10{sup 22} m{sup -2} (E>0.1 MeV). After exposure to 4x10{sup 22} m{sup -2} (E>0.1 MeV) the interlaminar shear strength of materials with a cyanate ester content of 40% or more is only reduced by 20% to 30%.

36 MATERIALS SCIENCE↗

Seasonal CO2 Observations on North and South of Mars as Seen by HEND (Mars Odyssey) and MOLA (MGS)

The first year of neutron mapping measurements from the Mars Odyssey spacecraft are presented based on observations from the High Energy Neutron Detector (HEND). The HEND instrument is a part of GRS suite responsible for registration of epithermal and fast neutrons originating in the Mars subsurface layer. The gamma ray and neutron spectrometers measure the scattering of fast neutrons from the Martian surface, which is caused by bombardment of primary cosmic rays and is strongly sensitive to the presence of hydrogen atoms. Even several percent subsurface hydrogen significantly depresses the flux of epithermal and fast neutrons. The recent Mars Odyssey observations detected a considerable amount of hydrogen, almost certainly corresponding to water ice, in the shallow near surface of the southern and northern hemispheres of Mars.

Litvak, M. L.↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗