Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “External events”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Late Toxicity and Patient Self-Assessment of Breast Appearance/Satisfaction on RTOG 0319: A Phase 2 Trial of 3-Dimensional Conformal Radiation Therapy-Accelerated Partial Breast Irradiation Following Lumpectomy for Stages I and II Breast Cancer

Purpose: Late toxicities and cosmetic analyses of patients treated with accelerated partial breast irradiation (APBI) on RTOG 0319 are presented. Methods and Materials: Patients with stages I to II breast cancer ≤3 cm, negative margins, and ≤3 positive nodes were eligible. Patients received three-dimensional conformal external beam radiation therapy (3D-CRT; 38.5 Gy in 10 fractions twice daily over 5 days). Toxicity and cosmesis were assessed by the patient (P), the radiation oncologist (RO), and the surgical oncologist (SO) at 3, 6, and 12 months from the completion of treatment and then annually. National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0, was used to grade toxicity. Results: Fifty-two patients were evaluable. Median follow-up was 5.3 years (range, 1.7-6.4 years). Eighty-two percent of patients rated their cosmesis as good/excellent at 1 year, with rates of 64% at 3 years. At 3 years, 31 patients were satisfied with the treatment, 5 were not satisfied but would choose 3D-CRT again, and none would choose standard radiation therapy. The worst adverse event (AE) per patient reported as definitely, probably, or possibly related to radiation therapy was 36.5% grade 1, 50% grade 2, and 5.8% grade 3 events. Grade 3 AEs were all skin or musculoskeletal-related. Treatment-related factors were evaluated to potentially establish an association with observed toxicity. Surgical bed volume, target volume, the number of beams used, and the use of bolus were not associated with late cosmesis. Conclusions: Most patients enrolled in RTOG 0319 were satisfied with their treatment, and all would choose to have the 3D-CRT APBI again.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ASASSN-14li: a model tidal disruption event

ASASSN-14li is a recently discovered tidal disruption event with an exceptionally rich data set: spectra and lightcurves in soft X-rays, UV, optical, and radio. To understand its emission properties in all these bands, we have extended our model for post-tidal disruption accretion and photon production to estimate both soft X-ray radiation produced by the “prompt” accretion phase and synchrotron emission associated with the bow shock driven through an external medium by the unbound tidal debris, as well as optical and UV light. We find that fiducial values of the stellar mass (1M{sub ⊙}) and black hole mass (10{sup 6.5}M{sub ⊙}) yield quantitative agreement with the optical/UV luminosity, lightcurve, and color temperature; approximate agreement with the soft X-ray spectrum and lightcurve; and quantitative agreement with the radio luminosity, spectrum, and lightcurve. Equipartition analysis of the radio data implies that the radio-emitting region expands with a constant speed, and its magnitude is comparable to the speed expected for the unbound stellar ejecta. Both facts provide strong support to our model. We find that the disruption event took place in 2014 mid-September. Two independent parameters, the magnitude and logarithmic radial gradient of the ambient gas density near the black hole, must be fit to the data to explain the radio emission; their inferred values are comparable to those found near both Sgr A* and the TDE candidate Swift J1644.

79 ASTRONOMY AND ASTROPHYSICS↗

Are Carotid Stent Fractures Clinically Significant?

Purpose: Late stent fatigue is a known complication after carotid artery stenting (CAS) for cervical carotid occlusive disease. The purpose of this study was to determine the prevalence and clinical significance of carotid stent fractures. Materials and Methods: A single-center retrospective review of 253 carotid bifurcation lesions treated with CAS and mechanical embolic protection from April 2001 to December 2009 was performed. Stent integrity was analyzed by two independent observers using multiplanar cervical plain radiographs with fractures classified into the following types: type I = single strut fracture; type II = multiple strut fractures; type III = transverse fracture; and type IV = transverse fracture with dislocation. Mean follow-up was 32 months. Results: Follow-up imaging was completed on 106 self-expanding nitinol stents (26 closed-cell and 80 open-cell stents). Eight fractures (7.5%) were detected (type I n = 1, type II n = 6, and type III n = 1). Seven fractures were found in open-cell stents (Precise n = 3, ViVEXX n = 2, and Acculink n = 2), and 1 fracture was found in a closed-cell stent (Xact n = 1) (p = 0.67). Only a previous history of external beam neck irradiation was associated with fractures (p = 0.048). No associated clinical sequelae were observed among the patients with fractures, and only 1 patient had an associated significant restenosis ({>=}80%) requiring reintervention. Conclusions: Late stent fatigue after CAS is an uncommon event and rarely clinically relevant. Although cell design does not appear to influence the occurrence of fractures, lesion characteristics may be associated risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zeptocalorimetry

Here we present the development of a Zeptocalorimeter. The motivation for designing and implementing such a device is driven, ultimately, by its anticipated exceptional sensitivity (10-21 J/K, at 2K). Such a device would be highly valuable in detecting minute quantities of mass for threat detection, studying fundamental phonon physics, and detecting energetic dissipation events at the attojoule level. To date, the most sensitive calorimeter demonstrated in the literature at 2K has been developed by the Roukes group at Caltech, where they achieved an addendum heat capacity of 10 -15 J/K with a 1/1000 sensitivity to external stimuli. To obtain such a low value of heat capacity requires a very small thermal mass, and thus, one of the greatest challenges in this project is the fabrication of this device, which requires numerous precision nanofabrication techniques. Furthermore, the heat capacity measurement of this device, as performed from room temperature to cryogenic temperatures, is equally challenging, as the transient signals used to determine the platform's thermal time constant require careful attention to the mitigation of feedthrough capacitance and delicate amplifier offsets. In this report we describe in detail the fabrication process flow for developing the calorimeter, including the layout and device design for obtaining a single lumped RC thermal resistance and capacitance, so that the device can be used for quantitative measurements of nanoscale materials with a suitable thermal link. The measurement method and experimental setup are also given, where we explain the heater and thermometer calibration methods, the thermal resistance measurements, the transient measurements, and lastly the cryogenic setup with intermediate frequency cabling and the thermal sinking of those lines.

47 OTHER INSTRUMENTATION↗

Discovery and Identification of Dimethylsilanediol as a Contaminant in ISS Potable Water

In September of 2010, analysis of ISS potable water samples was undertaken to determine the contaminant responsible for a rise in total organic carbon (TOC). As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds was initiated, resulting in an unknown peak being discovered in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples by evaporation and analyzing by GC/MS in full-scan mode. Although a computer match of the compound s identity could not be obtained with the instrument s database, a search with a more up to date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external Direct Analysis in Real Time (DART) GC/MS analysis. A preliminary GC/MS method was then developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for quantitation of DMSD.

Rutz, Jeffrey A.↗

Machine-learning Solution for Automatic Spacesuit Motion Recognition and Measurement from Conventional Video

Extravehicular Activity (EVA) spacesuits exhibit unique movement patterns due to their design characteristics. Mobility assessments using traditional motion capture systems are cost prohibitive and not feasible for some training conditions (e.g., simulated lunar outdoor terrain). This paper aims to present the ongoing development of machine learning solutions to quantify suit motions from conventional videos without special sensors or hardware. Preliminary work into this field was promising but given the fast growth in deep/machine learning technologies, external expertise was sought from open-source communities. Partnerships were formed with the NASA JSC Center of Excellence for Collaborative Innovation (CoCEI) and an execution crowdsourcing platform partner to solicit machine learning framework developments from external contenders. NASA provided contenders with images and video clips of spacesuits with simultaneously measured motion capture data during EVA simulation tasks. The contenders used this data to train and develop generalized algorithms to predict motions. At the end of the crowdsourcing event, the top five solutions were selected from 250 submissions. Each submission was tested and scored using video clips not previously disclosed to the contenders. The weighted scoring metrics measured how well the algorithm detected the suit shape, the 2D suit joint detection accuracy, and 3D joint detection accuracy. The winning solution was able to achieve roughly 85% prediction accuracy. Overall, the algorithms could efficiently detect various types of spacesuits and motions across different EVA environments such as the NASA Active Response Gravity Offload System (ARGOS). After continued improvements and validation, the fully developed system will enable EVA stakeholders to quantify suit kinematic patterns, which can help optimize suit, hardware, and task designs.

Linh Vu↗

Strategies for Fault Tolerance in Multicomponent Applications

This paper discusses on-going work with the Integrated Plasma Simulator (IPS), a framework for coupled multiphysics simulations of plasmas, to allow simulations to run through the loss of nodes on which the simulation is executing. While many different techniques are available to improve the fault tolerance of computational science applications on high-performance computer systems, checkpoint/restart (C/R) remains virtually the only one that see widespread use in practice. Our focus here is to augment the traditional C/R approach with additional techniques that can provide a more localized and tailored response to faults based on the ability to restart failed tasks on an individual basis, and the use of information external to the application itself in order to guide decision-making, in many cases avoiding the need to stop and restart the entire simulation. This capability involves several features within the IPS framework, and leverages the Fault Tolerance Backplane, a publish/subscribe event service to disseminate fault-related information throughout HPC systems, to obtain information from the Reliability, Availability and Serviceability (RAS) subsystem of the HPC system. This work is described in the context of Cray XT-series computer systems for concreteness, but is applicable to other environments as well. As part of the analysis of this work, we discuss the requirements to generalize this approach to other complex simulation applications beyond the Integrated Plasma Simulator.

99 GENERAL AND MISCELLANEOUS↗

Modeling behavior in a network using event logs

A framework is provided for modeling the activity surrounding user credentials and/or machine level activity on a computer network using computer event logs by viewing the logs attributed to each user as a multivariate data stream. The methodology performs well in detecting compromised user credentials at a very low false positive rate. Such a methodology may detect both users of compromised credentials by external actors and otherwise authorized users who have begun engaging in malicious activity.

Turcotte, Melissa J. M.↗

First test results from the Front-End Board with Cyclone V as a test high-resolution platform for the Auger-Beyond-2015 Front End Electronics

The paper presents the first results from the Front- End Board (FEB) with the biggest Cyclone{sup R} V E FPGA 5CEFA9F31I7N, supporting 8 channels sampled up to 250 MSps at 14-bit resolution. Considered sampling for the SD is 120 MSps, however, the FEB has been developed with external anti-aliasing filters to keep a maximal flexibility. Six channels are targeted to the SD, two the rest for other experiments like: Auger Engineering Radio Array and additional muon counters. More channels and higher sampling generate larger size of registered events. We used the standard radio channel for a radio transmission from the detectors to the Central Data Acquisition Station (CDAS) to avoid at present a significant modification of a software in both sides: the detector and the CDAS (planned in a future for a final design). Seven FEBs have been deployed in the test detectors on a dedicated Engineering Array in a hexagon. Several variants of the FPGA code were tested for 120, 160, 200 and even 240 MSps DAQ. Tests confirmed a stability and reliability of the FEB design in real pampas conditions with more than 40 deg. C daily temperature variation and a strong sun exposition with a limited power budget only from a single solar panel. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased infectious and noninfectious adverse events. The 5-year incidences of fat necrosis, breast pain, and rib fracture were slightly higher after brachytherapy than after EBRT (13.7% vs 8.1%, 19.4% vs 16.0%, and 1.6% vs 1.3%, respectively), but the risks were not significantly different for multichannel versus single-channel applicators. Conclusion: Toxicities after breast brachytherapy were distinct from those after EBRT. Temporal toxicity trends may reflect changing technology and evolving practitioner experience with brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Radiation and Magnetic-Field Effects on the Coherence and Stability of Transmon Qubits

Superconducting transmon qubits are a central building block of modern quantum computing architectures, yet their coherence properties remain sensitive to external influences that can limit performance or introduce temporal instabilities. In this talk, I will discuss two experimental studies aimed at quantifying these effects. First, I will examine how ionizing radiation impacts qubit relaxation. Using the same transmon device operated at two locations with dramatically different radiation backgrounds—the above-ground SQMS facility at Fermilab (USA) and the deep-underground Gran Sasso Laboratory (Italy)—we observe a higher rate of radiation-induced decay events above ground, even though intrinsic noise remains the dominant source of single-shot errors. I will also discuss the detection efficiency of a radiation detector made using such a device. Second, I will present results on how small magnetic fields, applied either during cooldown or at millikelvin temperatures, influence device stability. We find that fixed-frequency transmons maintain robust coherence up to approximately 600 mG of trapped out-of-plane field, and that controlled application of magnetic field can reduce temporal fluctuations in T1. Together, these studies provide insight into how external environments shape transmon coherence and offer potential pathways for improving qubit stability in scalable quantum processors.

Roy, Tanay [Fermilab]↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bifurcation-driven vertical plasma displacement

This paper considers vertical plasma motion resulting from plasma current decay during the disruption event. The presented filament-based model describes the motion in the ideal wall limit as an adiabatically slow evolution of the plasma equilibrium. Here, the equilibrium exhibits a pitchfork bifurcation when the decaying plasma current passes a critical value determined by the external magnetic field. This bifurcation affects the disruption-induced mechanical loads on the first wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Signature of a spin-up magnetar from multi-band afterglow rebrightening of GRB 100814A

In recent years, more and more gamma-ray bursts (GRBs) with late rebrightenings in their multi-band afterglows have revealed the late-time activity of their central engines. GRB 100814A is a special case among the well-sampled events, with complex temporal and spectral evolution. The single power-law shallow decay index of the optical light curve observed by GROND between 640 s and 10 ks is α{sub opt}=0.57±0.02, which apparently conflicts with expectations from the simple external shock model. In particular, there is remarkable rebrightening in the optical to near-infrared bands at late times, challenging the external shock model with synchrotron emission coming from the interaction of the blast wave with the surrounding interstellar medium. In this paper, we invoke a magnetar with spin evolution to explain the complex multi-band afterglow emission of GRB 100814A. The initial shallow decay phase in the optical bands and the plateau in the X-ray can be explained as being due to energy injection from a spin-down magnetar. At late times, with materials from the fall-back disk falling onto the central object of the burster, the angular momentum of the accreted materials is transferred to the magnetar, which leads to a spin up process. As a result, the magnetic dipole radiation luminosity will increase, resulting in significant rebrightening of the optical afterglow. We show that the model can well reproduce the observed multi-band afterglow emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Changing windstorm characteristics over the US Northeast in a single model large ensemble

Abstract Extreme windstorms pose a significant hazard to infrastructure and public safety, particularly in the highly populated US Northeast (NE). However, the influence climate change and changing land use will have on these events remains unclear. A large ensemble generated using the Max-Planck Institute (MPI) Earth system model is used to generate projections of NE windstorms under different shared socioeconomic pathways (SSPs) and to attribute changes to projected land use land cover (LULC) change, externally forced changes and internal climate variability. To reduce the influence of coarse grid cell resolution and uncertainties in surface roughness lengths, windstorms are identified using simultaneous widespread exceedance of local 99th percentile 10 m wind speeds (U 99 ). Projected declines in forest cover in the NE and the resulting reductions in surface roughness length under SSP3-7.0 lead to projections of large increases in U 99 and derived windstorm intensity and scale. However, these projected changes in regional LULC under SSP3-7.0 are unprecedented in a historical context and may not be realistic. After corrections are applied to remove the influence of LULC on wind speeds, regionally averaged U 99 exhibit declines for most of the single model initial-condition large ensemble (SMILE) members which are broadly proportional to the radiative forcing and global air temperature increase in the SSPs, with a median value of −0.15 ms −1 °C −1 . While weak cyclones are projected to decline in frequency in the NE, intense cyclones and the resulting windstorms and indices of socioeconomic loss do not. Where present, significant trends in these loss indices are positive, and some MPI SMILE members generate future windstorms that are unprecedented in the historical period.

Coburn, Jacob (ORCID:0000000309538117)↗

Tidal Love numbers of analog black holes

Tidal Love numbers quantify the conservative static response of compact objects to external tidal fields, and are found to vanish exactly for asymptotically flat black holes in four-dimensional general relativity. Many aspects of the physics of black holes have an analog in the theory of supersonic acoustic flows, including the existence of an event horizon and associated phenomena, such as quasinormal modes and superradiance. In this paper, we investigate the tidal Love numbers of acoustic black holes in different number of dimensions. We find that they exhibit a number of similar properties as higher-dimensional general relativistic black holes, such as logarithmic running with radial distance, and vanishing tidal response for special multipole moments. As a result, we show that the latter is a consequence of ladder symmetries, analogous to those identified for black holes.

Classical black holes↗

SU-D-9A-01: Listmode-Driven Optimal Gating (OG) Respiratory Motion Management: Potential Impact On Quantitative PET Imaging

Purpose: To evaluate the potential impact of listmode-driven amplitude based optimal gating (OG) respiratory motion management technique on quantitative PET imaging. Methods: During the PET acquisitions, an optical camera tracked and recorded the motion of a tool placed on top of patients' torso. PET event data were utilized to detect and derive a motion signal that is directly coupled with a specific internal organ. A radioactivity-trace was generated from listmode data by accumulating all prompt counts in temporal bins matching the sampling rate of the external tracking device. Decay correction for 18F was performed. The image reconstructions using OG respiratory motion management technique that uses 35% of total radioactivity counts within limited motion amplitudes were performed with external motion and radioactivity traces separately with ordered subset expectation maximization (OSEM) with 2 iterations and 21 subsets. Standard uptake values (SUVs) in a tumor region were calculated to measure the effect of using radioactivity trace for motion compensation. Motion-blurred 3D static PET image was also reconstructed with all counts and the SUVs derived from OG images were compared with SUVs from 3D images. Results: A 5.7 % increase of the maximum SUV in the lesion was found for optimal gating image reconstruction with radioactivity trace when compared to a static 3D image. The mean and maximum SUVs on the image that was reconstructed with radioactivity trace were found comparable (0.4 % and 4.5 % increase, respectively) to the values derived from the image that was reconstructed with external trace. Conclusion: The image reconstructed using radioactivity trace showed that the blurring due to the motion was reduced with impact on derived SUVs. The resolution and contrast of the images reconstructed with radioactivity trace were comparable to the resolution and contrast of the images reconstructed with external respiratory traces. Research supported by Siemens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional separation and reattachment

The separation of three dimensional turbulent boundary layers from the lee of flight vehicles at high angles of attack is investigated. The separation results in dominant, large scale, coiled vortex motions that pass along the body in the general direction of the free stream. In all cases of three dimensional flow separation and reattachment, the assumption of continuous vector fields of skin friction lines and external flow streamlines, coupled with simple laws of topology, provides a flow grammar whose elemental constituents are the singular points: the nodes, spiral nodes (foci), and saddles. The phenomenon of three dimensional separation may be construed as either a local or a global event, depending on whether the skin friction line that becomes a line of separation originates at a node or a saddle point.

Peake, D. J.↗