Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Autoindexing the diffraction patterns from crystals with a pseudotranslation

Lattice patterns containing alternating strong and weak reflections can be identified by a targeted search for the weak signals, permitting a wider range of diffraction patterns to be indexed automatically. Rotation photographs can be readily indexed if enough candidate Bragg spots are identified to properly sample the reciprocal lattice. However, while automatic indexing algorithms are widely used for macromolecular data processing, they can produce incorrect results in special situations where a subset of Bragg spots is systematically overlooked. This is a potential outcome in cases where a noncrystallographic translational symmetry operator closely mimics an exact crystallographic translation. In these cases, a visual inspection of the diffraction image will reveal alternating strong and weak reflections. However, reliable detection of the weak-intensity reflections by software requires a systematic search for a diffraction signal targeted at specific reciprocal-space locations calculated a priori by considering all possible pseudotranslations. Care must be exercised to distinguish between true lattice diffraction and spurious signals contributed by neighboring overlapping Bragg spots, non-Bragg diffraction and noise. Such procedures have been implemented within the autoindexing program LABELIT and applied to known cases from publicly available data sets. Routine use of this type of signal search adds only a few seconds to the typical run time for autoindexing. The program can be downloaded from http://cci.lbl.gov/labelit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Agent-Based and Production Cost Modeling Framework for Renewable Energy Studies

The agent-based framework for renewable energy studies (ARES) is an integrated approach that adds an agent-based model of industry actors to PLEXOS and combines the strengths of the two to overcome their individual shortcomings. It can examine existing and novel wholesale electricity markets under high penetrations of renewables. ARES is demonstrated by studying how increasing levels of wind will impact the operations and the exercise of market power of generation companies that exploit an economic withholding strategy. The analysis is carried out on a test system that represents the Electric Reliability Council of Texas energy-only market in the year 2020. The results more realistically reproduce the operations of an energy market under different and increasing penetrations of wind, and ARES can be extended to address pressing issues in current and future wholesale electricity markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimate of Fuel Consumption and GHG Emission Impact on an Automated Mobility District: Preprint

This study estimates the range of fuel and emissions impact of an automated-vehicle (AV) based transit system that services campus-based developments, termed an automated mobility district (AMD). The study develops a framework to quantify the fuel consumption and greenhouse gas (GHG) emission impacts of a transit system comprised of AVs, taking into consideration average vehicle fleet composition, fuel consumption/GHG emission of vehicles within specific speed bins, and the average occupancy of passenger vehicles and transit vehicles. The framework is exercised using a previous mobility analysis of a personal rapid transit (PRT) system, a system which shares many attributes with envisioned AV-based transit systems. Total fuel consumption and GHG emissions with and without an AMD are estimated, providing a range of potential system impacts on sustainability. The results of a previous case study based of a proposed implementation of PRT on the Kansas State University (KSU) campus in Manhattan, Kansas, serves as the basis to estimate personal miles traveled supplanted by an AMD at varying levels of service. The results show that an AMD has the potential to reduce total system fuel consumption and GHG emissions, but the amount is largely dependent on operating and ridership assumptions. The study points to the need to better understand ride-sharing scenarios and calls for future research on sustainability benefits of an AMD system at both vehicle and system levels.

33 ADVANCED PROPULSION SYSTEMS↗

Using a critical infrastructure game to provide realistic observation of the human in the loop by criminal justice students

Understanding human behavior is crucial in anticipating adversarial actions during cyberattacks. The Criminal Justice (CJ) discipline offers the necessary frameworks to unpack the complex facets of adversarial behavior and movement, and should therefore be leveraged for their possible contributions to the area of proactive cybersecurity. Yet the discipline remains weak at training current and future CJ workforce on these matters in a hands-on manner. This paper presents a cybersecurity training exercise where a power grid simulator is used to educate CJ students via experiential learning about concepts of cyberattacks and cybersecurity as well as exposing them to doing hands-on cybersecurity field research. The paper reports on Game use as an important opportunity to observe humans put under additional stress in operating conditions. The paper discusses what CJ students learn from multidisciplinary simulation-based exercises, the challenges and limitations they face, and how training this workforce could help contribute towards proactive cyberdefense of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of increased bioenergy demand on global food markets: an AgMIP economic model intercomparison

Integrated Assessment studies have shown that meeting ambitious greenhouse gas mitigation targets will require substantial amounts of bioenergy as part of the future energy mix. In the course of the Agricultural Model Comparison and Improvement Project (AgMIP), five global agro-economic models were used to analyze a future scenario with global demand for ligno-cellulosic bioenergy rising to about 100 ExaJoule in 2050. From this exercise a tentative conclusion can be drawn that ambitious climate change mitigation need not drive up global food prices much, if the extra land required for bioenergy production is accessible or if the feedstock, e.g. from forests, does not directly compete for agricultural land. Agricultural price effects across models by the year 2050 from high bioenergy demand in an RCP2.6-type scenario appear to be much smaller (+5% average across models) than from direct climate impacts on crop yields in an RCP8.5-type scenario (+25% average across models). However, potential future scarcities of water and nutrients, policy-induced restrictions on agricultural land expansion, as well as potential welfare losses have not been specifically looked at in this exercise.

agricultural markets↗

Physiological coherence in healthy volunteers during laboratory‐induced stress and controlled breathing

Abstract Physiological coherence has been related with a general sense of well‐being and improvements in health and physical, social, and cognitive performance. The aim of this study was to evaluate the relationship between acute stress, controlled breathing, and physiological coherence, and the degree of body systems synchronization during a coherence‐generation exercise. Thirty‐four university employees were evaluated during a 20‐min test consisting of four stages of 5‐min duration each, during which basal measurements were obtained (Stage 1), acute stress was induced using validated mental stressors (Stroop test and mental arithmetic task, during Stage 2 and 3, respectively), and coherence states were generated using a controlled breathing technique (Stage 4). Physiological coherence and cardiorespiratory synchronization were assessed during each stage from heart rate variability, pulse transit time, and respiration. Coherence measurements derived from the three analyzed variables increased during controlled respiration. Moreover, signals synchronized during the controlled breathing stage, implying a cardiorespiratory synchronization was achieved by most participants. Hence, physiological coherence and cardiopulmonary synchronization, which could lead to improvements in health and better life quality, can be achieved using slow, controlled breathing exercises. Meanwhile, coherence measured during basal state and stressful situations did not show relevant differences using heart rate variability and pulse transit time. More studies are needed to evaluate the ability of coherence ratio to reflect acute stress.

Mejía‐Mejía, Elisa↗

PlanHab * : hypoxia does not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone

Key points Superposition of hypoxia on 21 day bed rest did not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone. A significant impairment of maximal oxidative performance was identified downstream of cardiovascular O 2 delivery, involving both the intramuscular matching between O 2 supply and utilization and mitochondrial respiration. These chronic adaptations appear to be relevant in terms of exposure to spaceflights and reduced gravity habitats (Moon or Mars), as characterized by low gravity and hypoxia, in patients with chronic diseases characterized by hypomobility/immobility and hypoxia, as well as in ageing. Abstract Skeletal muscle oxidative function was evaluated in 11 healthy males (mean ± SD age 27 ± 5 years) prior to (baseline data collection, BDC) and following a 21 day horizontal bed rest (BR), carried out in normoxia ( = 133 mmHg; N‐BR) and hypoxia ( = 90 mmHg; H‐BR). H‐BR was aimed at simulating reduced gravity habitats. The effects of a 21 day hypoxic ambulatory confinement ( = 90 mmHg; H‐AMB) were also assessed. Pulmonary O 2 uptake ( ), vastus lateralis fractional O 2 extraction (changes in deoxygenated haemoglobin + myoglobin concentration, Δ[deoxy(Hb + Mb)]; near‐infrared spectroscopy) and femoral artery blood flow (ultrasound Doppler) were evaluated during incremental one‐leg knee‐extension exercise (reduced constraints to cardiovascular O 2 delivery) carried out to voluntary exhaustion in a normoxic environment. Mitochondrial respiration was evaluated ex vivo by high‐resolution respirometry in permeabilized vastus lateralis fibres. decreased ( P < 0.05) after N‐BR (0.98 ± 0.13 L min −1 ) and H‐BR (0.96 ± 0.17 L min −1 ) vs . BDC (1.05 ± 0.14 L min −1 ). In the presence of a decreased (by ∼6–8%) thigh muscle volume, normalized per unit of muscle mass was not affected by both interventions. Δ[deoxy(Hb + Mb)] peak decreased ( P < 0.05) after N‐BR (65 ± 13% of limb ischaemia) and H‐BR (62 ± 12%) vs . BDC (73 ± 13%). H‐AMB did not alter or Δ[deoxy(Hb + Mb)] peak . An overshoot of Δ[deoxy(Hb + Mb)] was evident during the first minute of unloaded exercise after N‐BR and H‐BR. Arterial blood flow to the lower limb during both unloaded and peak knee extension was not affected by any intervention. Maximal ADP‐stimulated mitochondrial respiration decreased ( P < 0.05) after all interventions vs . control. In 21 day N‐BR, a significant impairment of oxidative metabolism occurred downstream of cardiovascular O 2 delivery, affecting both mitochondrial respiration and presumably the intramuscular matching between O 2 supply and utilization. Superposition of H on BR did not worsen the impairment induced by BR alone.

Salvadego, Desy↗

Ultrasonic Phased Array Sound Field Mapping Through Large-Bore Coarse Grained Cast Austenitic Stainless Steel (CASS) Piping Materials

A sound field beam mapping exercise was conducted to further understand the effects of coarse grained microstructures found in CASS materials on phased array ultrasonic wave propagation. Laboratory measurements were made on three CASS specimens with different microstructures; the specimens were polished and etched to reveal measurable grain sizes, shapes and orientations. Three longitudinal, phased array probes were fixed on a specimen's outside diameter with the sound field directed toward one end (face) of the pipe segment over a fixed range of angles. A point receiver was raster scanned over the surface of the specimen face generating a sound field image. A slice of CASS material was then removed from the specimen end and the beam mapping exercise repeated. The sound fields acquired were analyzed for spot size, coherency, and beam redirection. Analyses were conducted between the resulting sound fields and the microstructural characteristics of each specimen.

Ultrasonic, Phased Array, NDE, Austenitic Steel, B↗

Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm{sup 2}) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after exercise demands specific quality assurance measures.

60 APPLIED LIFE SCIENCES↗

SU-F-E-10: Student-Driven Exploration of Radiographic Material Properties, Phantom Construction, and Clinical Workflows Or: The Extraordinary Life of CANDY MAN

Purpose: To develop a hands-on learning experience that explores the radiological and structural properties of everyday items and applies this knowledge to design a simple phantom for radiotherapy exercises. Methods: Students were asked to compile a list of readily available materials thought to have radiation attenuation properties similar to tissues within the human torso. Participants scanned samples of suggested materials and regions of interest (ROIs) were used to characterize bulk attenuation properties. Properties of each material were assessed via comparison to a Gammex Tissue characterization phantom and used to construct a list of inexpensive near-tissue-equivalent materials. Critical discussions focusing on samples found to differ from student expectations were used to revise and narrow the comprehensive list. From their newly acquired knowledge, students designed and constructed a simple thoracic phantom for use in a simulated clinical workflow. Students were tasked with setting up the phantom and acquiring planning CT images for use in treatment planning and dose delivery. Results: Under engineer and physicist supervision, students were trained to use a CT simulator and acquired images for approximately 60 different foodstuffs, candies, and household items. Through peer discussion, students gained valuable insights and were made to review preconceptions about radiographic material properties. From a subset of imaged materials, a simple phantom was successfully designed and constructed to represent a human thorax. Students received hands-on experience with clinical treatment workflows by learning how to perform CT simulation, create a treatment plan for an embedded tumor, align the phantom for treatment, and deliver a treatment fraction. Conclusion: In this activity, students demonstrated their ability to reason through the radiographic material selection process, construct a simple phantom to specifications, and exercise their knowledge of clinical workflows. Furthermore, the enjoyable and inexpensive nature of this project proved to attract participant interest and drive creative exploration. Mahon and Riblett have nothing to disclose; Hugo has a research agreement with Phillips Medical systems, a license agreement with Varian Medical Systems, research grants from the National Institute of Health. Authors do not have any potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-481: Physics Evaluation of a Newly Released InCise™ Multileaf Collimator for CyberKnife M6™ System

Purpose: This work reports the results of the physics evaluation of a newly released InCise™2 Multileaf Collimator (MLC) installed in our institution. Methods: Beam property data was measured with unshielded diode and EBT2 films. The measurements included MLC leaf transmission, beam profiles, output factors and tissue-phantom ratios. MLC performance was evaluated for one month after commissioning. Weekly Garden Fence tests were performed for leaf / bank positioning in standard (A/P) and clinically relevant non-standard positions, before and after MLC driving exercises of 10+ minutes. Daily Picket Fence test and AQA test, End-to-End tests and dosimetric quality assurance were performed to evaluate the overall system performance. Results: All measurements including beam energy, flatness and symmetry, were within manufacture specifications. Leaf transmission was 0.4% <0.5% specification. The values of output factors ranged from 0.825 (7.6 mm × 7.5 mm) to 1.026 (115.0 mm × 100.1 mm). Average beam penumbra at 10 cm depth ranged from 2.7mm/2.7mm(7.6 mm × 7.5 mm) to 6.0 mm/6.2mm(84.6 mm × 84.7 mm). Slight penumbra difference (<10% from average penumbra for fields >20 mm) was observed in the direction perpendicular to leaf motion due to the tilting of the leaf housing. Mean leaf position offsets was −0.08±0.07mm and −0.13 ± 0.08 for X1 and X2 leaf banks in 13 Garden Fence tests. No significant difference on average leaf positioning offsets was observed between different leaf orientations and before/after MLC driving exercises. Six End-to-End tests showed 0.43±0.23mm overall targeting accuracy. Picket-Fence and AQA showed stable performance of MLC during the test period. Dosimetric point dose measurements for test cases agreed with calculation within 3%. All film measurements on relative dose had Gamma (2%, 2mm) passing rate of >95%. Conclusion: The Incise™2 MLC for CyberKnife M6™ was proven to be accurate and reliable, and it is currently in clinical use. Stanford was one of the physics evaluation sites for the newly released InCise 2 MLC for Accuray Inc.

07 ISOTOPE AND RADIATION SOURCES↗

Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat

Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na + ], [K + ], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.

47 OTHER INSTRUMENTATION↗

Verification of R-matrix calculations for charged-particle reactions in the resolved resonance region for the 7 Be system

R-matrix theory is used to present nuclear reactions in the resolved resonance region. It uses information on bound states and low energy resonances to accurately parametrize cross sections on the resonances as well as the non-resonant background. Since the seminal work of Lane and Thomas (1958), the method has been widely used to analyze experimental cross-section data in a broad range of fields spanning nuclear reaction dynamics, nuclear astrophysics, ion beam analysis and their applications. Different R-matrix codes have been developed and used in these different applications with very little communication among the developers or practitioners on the capabilities, achievements or limitations of the codes. A limited comparison among three R-matrix codes on neutron-induced reactions was performed by the International Atomic Energy Agency (IAEA) International Evaluation of Neutron Cross Section Standards project (2007). Since then, significant progress has been made in their implementation of the R-matrix algorithms, and R-matrix codes have enhanced capabilities. In this paper we introduce, for the first time, the results of a comprehensive effort to verify the most widely used R-matrix codes in the various fields of nuclear science and applications: AMUR, AZURE2, CONRAD, EDA, FRESCO, GECCCOS, and SAMMY. In addition to the description of the capabilities of the codes and their specifications, we discuss the results of a joint exercise which was coordinated by the International Atomic Energy Agency. The aim of the exercise was to compare calculations of charged-particle reaction cross sections for the light composite system 7Be. The calculations were performed by the codes using identical input R-matrix parameters and other specifications and were limited to charged-particle channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of therapeutic targets in a murine model of severe exertional heat stroke

Exertional heat stroke (EHS) is a potentially lethal condition resulting from high core body temperatures (T C ) in combination with a systemic inflammatory response syndrome (SIRS) with varying degrees of severity across victims, and limited understanding of the underlying mechanism(s). We established a mouse model of severe EHS to identify mechanisms of hyperthermia/inflammation that may be responsible for organ damage. Mice were forced to run on a motorized wheel in a 37.5°C chamber until loss of consciousness and were either removed immediately (exertional heat injury or EHI; T CMax = 42.4 ± 0.2°C) or remained in the chamber an additional 20 min (EHS; T CMax = 42.5 ± 0.4°C). Exercise control mice (ExC) experienced identical procedures to EHS at 25°C. At 3 h post-EHS, there was evidence for an immune/inflammatory response as elevated blood chemokine [interferon γ-induced protein 10 (IP-10), keratinocytes-derived chemokine (KC), macrophage inflammatory proteins (MIP-1α), MIP-1β, MIP-2] and cytokine [granulocyte colony-stimulating factor (G-CSF), interleukins (IL-10), IL-6] levels peaked and were highest in EHS mice compared with EHI and ExC mice. Immunoblotting of organs susceptible to EHS damage indicated that several kinases were sensitive to stress associated with heat/inflammation and exercise; specifically, phosphorylation of liver c-Jun NH 2 -terminal kinase (JNK) at threonine 183/tyrosine 185 immediately (0 h) postheating related to heat illness severity. We have established a mouse EHS model, and JNK [or its downstream target(s)] could underlie EHS symptomatology, allowing the identification of molecular pathways or countermeasure targets to mitigate heat illness severity, enable complete recovery, and decrease overall EHS-related fatalities.

Physiology↗

Verification and Validation of Two Hydrodynamic Methods for Simulations of High Energy Density Physics Problems

A 3D verification and validation suite of test problems is presented and used to evaluate hydrodynamic methods within a radiation hydrodynamics code, xRAGE. These test problems exercise different levels of complexity, building towards ICF problems which in addition to hydrodynamics also include three temperature plasma physics, thermal conduction, and radiation diffusion. Among the problems in the test suite are the Kidder ball problem, the Verney shell problem, and a 5-material compression problem, which exercise different purely hydrodynamic methods implemented within xRAGE. There is excellent agreement between 2D and 3D XRAGE simulation results and between the xRAGE results and the benchmark solutions. Two 3D ICF test problems are also presented, based on an OMEGA direct drive capsule experiment and on a NIF indirect drive capsule experiment. It is demonstrated that the newer unsplit hydrodynamic method in xRAGE produces more vorticity relative to the older default method. For the indirect drive capsule, the 3D simulations are in reasonable agreement with the experimental values of ion temperature and neutron production.

47 OTHER INSTRUMENTATION↗

Scribe Network API v.1.0.0

SAND2023-07864O Scribe Network API is an add-on tool for Scribe3D software. Scribe Network API documents tabletop exercises in trainings and plays back simulated videos of the scenarios and responses. Users can apply the software to compiled projects, or to a simple visual studio project solution package. The software runs a web application that relays information between computers using Scribe3D through a web application, or web app. The web app involves a representational state transfer (REST) application programming interface that handles sending and receiving Scribe save files and an SQL server that stores the save files. This follow-on package allows users to facilitate a networked tabletop exercise. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Noel, Todd↗

Simplified Approximations of Direct Cumulus Entrainment and Detrainment

Abstract In recent years, direct calculations of simulated cumulus entrainment and detrainment have facilitated new physical insights into these highly elusive but critically important processes. However, these calculations require substantial computational resources that may limit their widespread usage. To facilitate such calculations, two simplified approximations of direct cumulus entrainment and detrainment are examined herein. The first approximation, termed the “semidirect” method, follows a standard bulk approach but makes more realistic assumptions about the sources of entrained and detrained air near the cloud edges. In contrast, the second approximation (the “projection” method) uses the governing equations of motion to project whether grid points near the cloud edge will entrain or detrain as the mean cloud ascends by one grid point. Verification exercises using large-eddy simulations reveal that both methods generally agree better with corresponding direct entrainment/detrainment estimates than the traditional bulk formulation, with the projection method outperforming the semidirect method. The two methods can be used in a synergistic fashion, with the semidirect method helping to optimize the projection method, to suit a wide range of applications. Because the latter incorporates the essential dynamics of entrainment and detrainment at the local scale, it can be used to gain physical insight into the causal mechanisms regulating these complex processes.

Meteorology & Atmospheric Sciences↗

Organically bound tritium analysis in environmental samples

Organically bound tritium (OBT) has become of increased interest within the last decade, with a focus on its behaviour and also its analysis, which are important to assess tritium distribution in the environment. In contrast, there are no certified reference materials and no standard analytical method through the international organization related to OBT. In order to resolve this issue, an OBT international working group was created in May 2012. Over 20 labs from around the world participated and submitted their results for the first intercomparison exercise results on potato (Sep 2013). The samples, specially-prepared potatoes, were provided in March 2013 to each participant. Technical information and results from this first exercise are discussed here for all the labs which have realised the five replicates necessary to allow a reliable statistical treatment. The results are encouraging as the increased number of participating labs did not degrade the observed dispersion of the results for a similar activity level. Therefore, the results do not seem to depend on the analytical procedure used. From this work an optimised procedure can start to be developed to deal with OBT analysis and will guide subsequent planned OBT trials by the international group.

07 ISOTOPE AND RADIATION SOURCES↗