Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Quantitative magnetic force microscopy using calibration on superconducting flux quanta

We present a new procedure that takes advantage of the magnetic flux quantization of superconducting vortices to calibrate the magnetic properties of tips for magnetic force microscopy (MFM). Indeed, a superconducting vortex, whose quantized flux is dependent upon Plank constant, speed of light and electron charge, behaves as a very well defined magnetic reference object. The proposed calibration procedure has been tested on new and worn tips and shows that the monopole point-like approximation of the probe is a reliable model. This procedure has been then applied to perform quantitative MFM experiments on a soft ferromagnetic thin film of permalloy, leading to the determination of the local out-of-plane component of the canted magnetization, together with its spatial variations across a few μm 2 scan area.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metal leaching from Lithium-ion and Nickel-metal hydride batteries and photovoltaic modules in simulated landfill leachates and municipal solid waste materials

Photovoltaic (PV) modules and batteries can either be recycled or disposed of in landfills at end-of-life (EoL). This work focuses on disposal since the benefit of recycling PV modules and batteries is well established. This study characterizes the potential toxicity due to metals leaching from selected PV modules and batteries through both the Toxicity Characteristic Leaching Procedure (TCLP) and in-house batch leaching protocols to probe the impact on metallic ion mobility as a function of the different types of e-waste entering the waste stream, the magnitude of device damage when placed into the waste stream, and the simulated municipal solid waste (SMSW) composition. Our results showed that one PV module and three battery types in this study should be classified as hazardous waste within the U.S. However, for some of the other e-wastes, metals of concern including Cr, Cu, Hg, Ni, Pb, and Zn leached during the batch tests but not in the TCLP regulatory method. For most of the waste types, the amounts of metals that leached in the TCLP test and batch tests were much lower than the total extractable amounts, demonstrating the potential for additional unaccounted for amounts of metals to leach. Our results demonstrate that the TCLP regulatory method might fail at predicting potential leaching and at capturing the complexity of e-waste leaching in landfill conditions. It confirms that additional work is needed urgently to develop appropriate EoL procedures for MSW with PV and battery e-waste.

42 ENGINEERING↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing conventional High-Resolution Electron Microscopy

Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.

440800* -- Miscellaneous Instrumentation-- (1990-)↗

Electronic compensation for reflector surface distortion to improve radiation pattern characteristics of antennas

A simple procedure is described for determining the excitation coefficients of an array feed which compensates for the surface distortion of a reflector antenna to improve the radiation pattern in such a way as to approximate the performance of the undistorted antenna. A computer simulation for a practical feed array is presented as an example of compensation for the distortion of an actual antenna.

Bailey, M. C.↗

Integrated Procedures for Flight and Ground Operations Using International Standards

Imagine astronauts using the same Interactive Electronic Technical Manuals (IETM's) as the ground personnel who assemble or maintain their flight hardware, and having all of that data interoperable with design, logistics, reliability analysis, and training. Modern international standards and their corresponding COTS tools already used in other industries provide a good foundation for streamlined technical publications in the space industry. These standards cover everything from data exchange to product breakdown structure to business rules flexibility. Full Product Lifecycle Support (PLCS) is supported. The concept is to organize, build once, reuse many ways, and integrate. This should apply to all future and some current launch vehicles, payloads, space stations/habitats, spacecraft, facilities, support equipment, and retrieval ships.

Ingalls, John↗

Transmission Electron Microscope In Situ Straining Technique to Directly Observe Defects and Interfaces During Deformation in Magnesium

In-situ straining was used to study deformation behavior of hexagonal close-packed (hcp) metals.Twinning and dislocation motion, both essential to plasticity in hcp materials, were observed.Typically, these processes are characterized post-mortem by examining remnant microstructural features after straining has occurred. By imposing deformation during imaging, direct observation of active deformation mechanisms is possible. This work focuses on straining of structural metals in a transmission electron microscope (TEM), and a recently developed technique that utilizes familiar procedures and equipment to increase ease of experiments. In-situ straining in a TEM presents several advantages over conventional post-mortem characterization, most notably time-resolution of deformation and streamlined identification of active deformation mechanisms. Drawbacks to the technique and applicability to other studies are also addressed. In-situ straining is used to study twin boundary motion in hcp magnesium. A {101¯2} twin was observed during tensile and compressive loading. Twin-dislocation interactions are directly observed. Notably, dislocations are observed to remain mobile, even after multiple interactions with twin boundaries, a result which suggests that Basinki’s dislocation transformation mechanism by twinning is not present in hcp metals. The coupling of in-situ straining with traditional post-mortem characterization yields more detailed information about material behavior during deformation than either technique alone.

magnesium↗

Three-dimensional scanning transmission electron microscopy of biological specimens

A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2 - 3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original data set. The precision of the height determination was 0.2 nm. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy (TEM). However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Analysis of Electron Runaway in the Presence of Enhanced Field in the Vicinity of a Microtip

Transition of field-emission electrons to the runaway regime in the region of enhanced electric field determined by the configuration of a microtip on a cathode is studied at several pressures of gas medium. The problem is solved using simulation of electron motion in the presence of nonuniform electric field with the aid of the Monte Carlo procedure in the 2D configuration. Nitrogen is used as a working gas. Passage through a relatively small region of the enhanced field in the vicinity of the microtip may substantially facilitate electron escape to the runaway regime, especially, at pressures of greater than 10 atm. In our opinion, the resulting runaway electrons may provide preionization of gas medium and formation of the initial stage of a 3D discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bending of skew plates of variable rigidity.

Description of an analytical procedure for studying the bending of thin skew plates of a thickness varying in one direction, under arbitrary lateral loading. The analysis was programmed for execution on an electronic computer for various conditions and types of loading. The results obtained suggest that the proposed analytical procedure is more accurate than the finite-difference technique used in earlier investigations.

Willems, N.↗

Model-independent extraction of the proton charge radius from electron scattering

Constraints from analyticity are combined with experimental electron-proton scattering data to determine the proton charge radius. In contrast to previous determinations, we provide a systematic procedure for analyzing arbitrary data without model-dependent assumptions on the form-factor shape. We also investigate the impact of including electron-neutron scattering data, and {pi}{pi}{yields}NN data. Using representative data sets we find r{sub E}{sup p}=0.870{+-}0.023{+-}0.012 fm using just proton scattering data; r{sub E}{sup p}=0.880{sub -0.020}{sup +0.017{+-}}0.007 fm adding neutron data; and r{sub E}{sup p}=0.871{+-}0.009{+-}0.002{+-}0.002 fm adding {pi}{pi} data. The analysis can be readily extended to other nucleon form factors and derived observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical study of precipitating electrons

Energy spectra of precipitating electrons are fitted to the sum of three distributions: a power law, a Maxwellian and a Gaussian. This fitting procedure determines seven parameters which characterize the essential features of each spectrum. These characteristic parameters are used to carry out various studies involving precipitating electrons. It is shown that the absence of the power-law population from a particular spectrum is related to the softness of the precipitating primary flux, that the Maxwellian temperature and the Gaussian peak energy have a positive correlation the strength of which varies with local time, that the upward moving Gaussian population has a loss cone distribution, and that the one dimensional velocity distribution parallel to the magnetic field occasionally displays a plateau or a hump on the tail.

Fontheim, E. G.↗

Importance of bulk excitations and coherent electron-photon-phonon scattering in photoemission from PbTe(111): Ab initio theory with experimental comparisons

This paper presents a fully ab initio many-body photoemission framework that includes coherent three-body electron-photon-phonon scattering to predict the transverse momentum distributions and the mean transverse energies (MTEs) of bulk photoelectrons from single-crystal photocathodes. The need to develop such a theory stems from the lack of studies that provide complete understanding of the underlying fundamental processes governing the transverse momentum distribution of photoelectrons emitted from single crystals. For example, initial predictions based on density-functional theory calculations of effective electron masses suggested that the (111) surface of PbTe would produce very small MTEs (≤ 15 meV), whereas our experiments yielded MTEs ten to twenty times larger than these predictions and also exhibited a lower photoemission threshold than predicted. The ab initio framework presented in this paper correctly reproduces both the magnitude of the MTEs from our measurements in PbTe(111) and the observed photoemission below the predicted threshold. Our results show that both photoexcitations into states that propagate in the bulk of the material and coherent many-body electron-photon-phonon scattering processes, which initial predictions ignored, play surprisingly important roles in photoemission from PbTe(111). Lastly, from the lessons learned, we recommend a procedure for rapid computational screening of potential single-crystal photocathodes for applications in next-generation ultrafast electron diffraction and X-ray free-electron lasers, which will enable significant advances in condensed matter research.

36 MATERIALS SCIENCE↗

Array feed synthesis for correction of reflector distortion and Vernier Beamsteering

An algorithmic procedure for the synthesis of planar array feeds for paraboloidal reflectors is described which simultaneously provides electronic correction of systematic reflector surface distortions as well as a Vernier electronic beamsteering capability. Simple rules of thumb for the optimum choice of planar array feed configuration (i.e., number and type of elements) are derived from a parametric study made using the synthesis procedure. A number of f/D ratios and distortion models were examined that are typical of large paraboloidal reflectors. Numerical results are presented showing that, for the range of distortion models considered, good on-axis gain restoration can be achieved with as few as seven elements. For beamsteering to +/- 1 beamwidth (BW), 19 elements are required. For arrays with either 7 or 19 elements, the results indicate that the use of high-aperture-efficiency elements (e.g., disk-on-rod and short backfire) in the array yields higher system gain than can be obtained with elements having lower aperture efficiency (e.g., open-ended waveguides). With 37 elements, excellent gain and beamsteering performance to +/- 1.5 BW are obtained independent of the assumed effective aperture of the array element. An approximate expression is derived for the focal-plane field distribution of the distorted reflector. Contour plots of the focal-plane fields are also presented for various distortion and beam scan angle cases. The results obtained show the effectiveness of the array feed approach.

Blank, S. J.↗

Photoemission electron microscopy and scanning electron microscopy of Magnetospirillum magnetotacticum ’s magnetosome chains

Magnetotactic bacteria are of great interdisciplinary interest, since a vast field of applications from magnetic recording media to medical nanorobots is conceivable. A key feature for a further understanding is the detailed knowledge about the magnetosome chain within the bacteria. We report on two preparation procedures suitable for UHV experiments in reflective geometry. Further, we present the results of scanning electron microscopy, as well as the first photoemission electron microscopy experiments, both accessing the magnetosomes within intact magnetotactic bacteria and compare these to scanning electron microscopy data from the literature. From the images, we can clearly identify individual magnetosomes within their chains.

Keutner, Christoph↗

Flight management - Pilot procedures and system interfaces for the 1980-1990's

In the air transportation system of the 1980-1990's, aircraft must perform with greater precision in time and position than is possible today. Rapid development in electronics technology makes renovation in airborne-system concepts feasible. The Ames Research Center is conducting research on pilot procedures and pilot-system interfaces for such systems. Research on various pilot-system interface devices and manned simulations was conducted to study rules of distributed decision making authority among pilots and controllers with various airborne display concepts, and a pilot-oriented command logic for the control of avionic systems was studied. Results are summarized, and ongoing work and future research plans described.

Wempe, T. E.↗

Strategy for alignment of electron beam trajectory in LEReC cooling section

We considered the steps required to align the electron beam trajectory through the LEReC cooling section. We devised a detailed procedure for the beam-based alignment of the cooling section solenoids. We showed that it is critical to have an individual control of each CS solenoid current. Finally, we modeled the alignment procedure and showed that with two BPM fitting the solenoid shift can be measured with 40 um accuracy and the solenoid inclination can be measured with 30 urad accuracy. These accuracies are well within the tolerances of the cooling section solenoid alignment.

43 PARTICLE ACCELERATORS↗

Rocket measurement of auroral electron fluxes associated with field-aligned currents

A rocket-borne experiment using an electron and proton energy spectrometer is described, with particular reference to calibration and data reduction procedures. An upper limit of the measured proton flux is found to be 1,000,000 protons per sq cm sec sr keV. The characteristics of particle precipitation observed during flight over the auroral band are evaluated. The electron flux in regions of maximum flux tends to be the most field-aligned in the energy interval with the highest intensity.

Pazich, P. M.↗