Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electricity Market”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Kennedy Space Center's Partnership with Graftel Incorporated

NASA Kennedy Space Center (KSC) has recently partnered with Graftel Incorporated under an exclusive license agreement for the manufacture and sale of the Smart Current Signature Sensor. The Smart Current Signature Sensor and software were designed and developed to be utilized on any application using solenoid valves. The system monitors the electrical and mechanical health of solenoids by comparing the electrical current profile of each solenoid actuation to a typical current profile and reporting deviation from its learned behavior. The objective of this partnership with Graftel is for them to develop the technology into a hand-held testing device for their customer base in the Nuclear Power Industry. The device will be used to perform diagnostic testing on electromechanical valves used in Nuclear Power plants. Initially, Graftel plans to have working units within the first year of license in order to show customers and allow them to put purchase requests into their next year's budget. The subject technology under discussion was commercialized by the Kennedy Space Center Technology Programs and Partnerships Office, which patented the technology and licensed it to Graftel, Inc., a company providing support, instrumentation, and calibration services to the nuclear community and private sector for over 10 years. For the nuclear power industry, Graftel designs, manufacturers, and calibrates a full line of testing instrumentation. Grafters smart sensors have been in use in the United States since 1993 and have proved to decrease set-up time and test durations. The project was funded by Non-Destructive Engineering, and it is felt that this technology will have more emphasis on future vehicles. Graftel plans to market the Current Signature Sensor to the Electric Utility industry. Graftel currently supplies product and services to the Nuclear Power Industry in the United States as well as internationally. Product and services sold are used in non-destructive testing for valves, penetrations and other applications. Graftel also supplies testing services to an industrial customer base. The customer base includes 90 percent of the U.S. Nuclear plants and plants in Brazil, Europe, and Asia. Graftel works internationally with two representative groups and employees and has ten people at the principle location and a group of contract engineers around the country.

Dunn, Carol Anne↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential missions for advanced airships

The freight commodity transport and the intercity passenger travel markets in the U.S. for 1967 and 1972 are analyzed, along with 1985 estimates, in order to establish the size, speed and cost enabling use of the airship in these markets. Items examined include frozen meat, confectionary, drugs, electrical equipment, mechanical parts, clothing and plastic products. A 50 ton/500 passenger payload capacity, a cruise speed of 100 kt and a VTOL capability or at minimum short take-off and vertical landing capability are needed to make an LTA vehicle viable in the transport market if it had a direct operating cost of $500 to $800 per hour for freight carrying and $1100 to $2700 an hour in passenger service with utilizations between 2000 hours and 4000 hours a year.

Grant, D. T.↗

Status and Trends in the U.S. Voluntary Green Power Market: 2022 Data

Voluntary green power, for the purposes of this report, refers to renewable energy procurement by retail electricity customers above what is otherwise provided by load-serving entities. This report is part of an annual series of reports synthesizing trends in the United States voluntary green power market. In 2022, about 9.6 million retail electricity customers procured about 272 million megawatt-hours (MWh) of voluntary green power, representing about 38% of non-hydro renewable energy sales and about 6% of all U.S. retail electricity sales. Most of the remainder of U.S. renewable energy sales reflects renewable energy procured by load-serving entities to comply with state renewable energy mandates, also known as compliance-based procurement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Low Cost High-Performance HRE-Free 3-in-1 Electric Drive Unit

The project team completed work to expand upon American Axle & Manufacturing’s (AAM) baseline technology and develop a high-speed, AC induction electric drive unit (EDU) with total direct-oil-cooling and integrated power electronics. The project accelerated advancements in EDU technology by allowing AAM to build upon the progress made in developing the underlying baseline technologies. The following seven improvements to AAM’s baseline technology were implemented in this research and development program: 1) Increased speed (30k RPM) AC induction motor, 2) Silver-sintering of discrete silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFET) to heat sinks, 3) Electrically insulated rotor bars, 4) Optimized lamination steel, 5) EDU-integrated 650VDC inverter package, 6) Over-molded stator with molded liners, and 7) 650VDC power-dense stator design. The successful development of the technology resulted in a meaningful cost reduction for EDU systems in the market. Coupled with falling battery system costs, lower EDU costs will likely accelerate the market acceptance and related production scaling of battery electric vehicles. The objective of this project was to research, develop, and test a Heavy Rare Earth (HRE)-free 3-In-1 electric drive unit (EDU) that has class leading power density and cost. The key technologies to be developed were anticipated to meet or exceed the Department of Energy (DOE) targets of a cost ≤ $\$$7/kilowatt (kW), power density ≥ 12 kW/liter, and operating voltage ≥ 600 VDC.

33 ADVANCED PROPULSION SYSTEMS↗

Project developer options to enhance the value of solar electricity as solar and storage penetrations increase

Increasing the penetration of photovoltaics (PV) reduces the marginal grid value of PV electricity. The declining grid value of PV with higher penetration could limit the technology's economic attractiveness and future demand. Various strategies have been proposed for preserving this value. Using a consistent framework, we analyze the net value (accounting for both cost and grid value) of more than ten strategies in the United States. Here, grid value is estimated from coincident wholesale power market prices and PV generation using observed historical prices or modeled future prices with up to 30% PV penetration. We find that established and emerging strategies designed to shift the timing of standalone PV generation at the expense of total generation—including orienting monofacial PV modules west or bifacial modules vertically—result in minor net-value benefits or penalties. Adding energy storage to such systems magnifies the net-value loss, because configurations that change the timing of PV production become redundant when the energy-shifting capabilities of storage are added. The largest net-value gains come from strategies that maximize generation (solar tracking plus oversized PV arrays) in conjunction with storage, especially at high PV penetrations. PV systems are long-lived assets. Our results suggest that efforts to promote generation-maximizing strategies today may yield increasing net-value benefits as PV and storage deployments continue to accelerate in the United States over the coming decades.

14 SOLAR ENERGY↗

Online Energy-optimal Routing for Electric Vehicles with Combinatorial Multi-arm Semi-Bandit

We have seen a rapid growth in the adoption of electric vehicle in today’s commercial mobility service market, from carrying passengers to the delivery of goods. One cardinal issue concerning the operation of EVs is the optimal routing of EV fleets with limited battery capacity. In this study, we investigate the energy-optimal online routing problem for the fleet of EVs, which focuses on identifying real-time minimum electricity consumption paths (MECP) for multiple OD pairs with limited information. We develop a multi-OD combinatorial multi-arm semi-bandit model (MCMAB) that uses the fleet of EVs as sensors in the transportation network and promotes the utilization of common information shared by different OD pairs. We further enrich the model with the path elimination policy to obtain MECP of high confidence while significantly reducing the number of learning iterations and the number of explorations needed. We demonstrate the effectiveness of the MCMAB and the efficiency of the path elimination policy with comprehensive numerical experiments in Manhattan, NYC. The results show that the proposed online routing algorithms can achieve near-optimal MECPs efficiently, and the quality of the solutions is significantly better than using the shortest travel time paths as approximate MECPs.

Chen, Xiaowei↗

Development of dual phase soft magnetic laminate for advanced electric machines

The development of dual phase soft magnetic laminate for advanced electric machines at General Electric is summarized, including alloy development, properties, manufacturing trials, prototype experience, potential applications, and future material development. Dual phase soft magnetic laminates provide the flexibility to tune magnetic/non-magnetic state at the desired locations, using solution nitriding treatment with protective mask/coating. This enabling material technology benefits electric machine performance by reducing flux leakage in the laminates. It also decouples the electromagnetic and mechanical design, which opens up the design space for advanced electric machines. Magnetic and mechanical properties of dual phase laminates were compared to commercial FeSi and FeCo soft magnetic laminates. Driven by the market needs for high power density and high-speed electric machines, a synchronous reluctance (SynRel) machine without PMs using dual phase soft magnetic laminates was assessed in machine electromagnetic performance as well as rotor stress analysis by finite element simulation. Successful prototype build and testing further retired manufacturing risks and advanced the technology maturity level. Future material development with higher mechanical strength, higher saturation magnetization, higher permeability, and lower loss are highly desired for ground and air transportation electrification.

Rallabandi, Vandana↗

Equity in Transactive Energy Systems

Transactive energy (TE) research primarily focuses on efficient and reliable operation of the electricity grid by using economic or market-based constructs to incorporate significant amounts of responsive, demand-side assets. This research examines the literature to evaluate if the design of TE demonstrations incorporates microeconomic principles of equity and fairness. We also consider the extent to which the design and implementation of TE affects energy inequities, and how these inequities could be addressed in future research with specific equity valuation metrics. The design of TE systems can impact energy equity across several dimensions and we provide recommendations for incorporating microeconomic principles of equity and fairness in TE system architecture as well as metrics for improving equitable outcomes in TE system design, implementation, and performance.

Energy, Transactive Energy, Economics↗

Decarbonizing Medium- & Heavy-Duty On-Road Vehicles: Zero-Emission Vehicles Cost Analysis

We simulate adoption and energy consumption of zero-emission vehicles (ZEVs) in the medium and heavy duty (MD/HD) sector. With continued improvement in ZEV technologies, total-cost-of-driving parity with conventional vehicles is achievable by 2035 for all MD/HD vehicle classes. Two technological solutions – battery electric vehicles (BEVs) and fuel cell electric vehicles (FCEVs) are viable in multiple market segments, offering alternative pathways for decarbonization. In this scenario, ZEV sales reach 99+% by 2045 and 42% by 2030. 80% of the MD/HD stock transitions to ZEVs by 2050, reducing CO2 emissions by 69% from 2019. Disparities in adoption rate and vehicle usage between vehicle classes and between short and long-haul applications highlight opportunities for targeted policies (to reduce emissions it is critical to understand what vehicles transition to ZEV, not just how many vehicles). Results are highly sensitive to assumed fuel prices, technology improvement trajectories, adoption decision-making, and assumptions about future freight demand and vehicle use.

33 ADVANCED PROPULSION SYSTEMS↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Electric Turboprop Commercial Freighter Opportunity

As the era of electric and hybrid electric aviation is dawning, we have the opportunity to reduce cost, energy use, and emissions of air transportation. In this paper, the case is made for the potential efficiency benefits that can be gained with hybrid electric propulsion. Initial economic, mission profile, and propulsion system concepts for a large turboprop aircraft we designate as the Hybrid Electric Turboprop Commercial Freighter (HETCOF) are presented. Market analysis shows HETCOF has the potential to serve a large market share, but the cost requirements for a new purpose built are challenging relative to the repurposed narrow body aircraft currently operating in the market. Comparing HETCOF to a genericized large turboprop freighter the payload capacity is reduced by 40% for the TRL 5+ configuration but is equivalent to the baseline for the TRL 1-2 configuration. All HETCOF configurations result in increased efficiency and subsequent block fuel, block energy, and block emissions reductions. An integrated power/thermal/and energy storage system is presented and analyzed using key performance parameters to estimate weights and losses at three technology readiness levels. Analysis shows that for a concept like this to have economic and energy benefits, many TRL 1-2 level technologies would be needed. Relevant ARPA-E programs and NASA technologies being developed to enable the benefit are also described. The most significant result of this paper is that the HETCOF concept can close with reduced fuel burn, energy use, and emissions while retaining some or all of the cargo capability of the baseline aircraft across TRL level assumptions, which enables this platform to be used for near term introduction with increasing benefits as technology matures.

Ralph H Jansen↗

Status and Trends in the U.S. Voluntary Green Power Market (2021 Data)

Voluntary green power, for the purposes of this report, refers to renewable energy procurement by retail electricity customers above state renewable energy mandates. In this report, we present data and key trends for voluntary green power markets, except for a small portion of voluntary purchasing where no data are available. In 2021, about 8 million retail electricity customers procured about 244 million megawatt-hours (MWh) of voluntary green power (Figure ES-1), representing about 27% of all U.S. renewable energy sales, about 39% of non-hydro renewable energy sales, and about 6% of all U.S. retail electricity sales. Most of the remainder of U.S. renewable energy sales reflects renewable energy procured by load-serving entities to comply with state renewable energy mandates, also known as compliance-based procurement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Corridor Design and Analysis for UAM Operations

The Urban Air Mobility (UAM) concept is a part of Advanced Air Mobility (AAM), a joint initiative between the Federal Aviation Administration (FAA), NASA, and industry to develop an air transportation system that uses new electric (i.e., green) air vehicles in geographical areas previously underserved by traditional aviation. Market forecast studies predict that there will be demand for alternate modes of air transportation using electric Vertical Take-off and Landing aircraft. UAM expands transportation networks by introducing short flights to move people and goods around metropolitan areas​. UAM is expected to improve mobility for the public, decongest road traffic, reduce trip time, and decrease strain on existing public transportation networks. Various challenges exist to make the introduction of UAM operations successful in the U.S. National Airspace System (NAS). These include but are not limited to integration with existing airports and airspace, provision of air traffic services (e.g., separation), vehicle design and certification, and community acceptance. The focus of this paper is on integration of UAM operations into the NAS via introduction of new airspace structures. UAM will operate within a regulatory, operational, and technical environment that is incorporated into the NAS​. As per the UAM Concept of Operations (ConOps), the FAA retains regulatory authority and is responsible for establishing operational parameters and maintaining oversight. The FAA’s UAM ConOps describes flights at low altitudes (below 5,000 ft) with minimal disruption to established conventional aircraft traffic and limited voice interactions with the Air Traffic Control (ATC). Early stages of UAM may use existing procedures to safely integrate UAM with conventional flights. This would involve flying under Part 91 Visual Flight Rules (VFR) and using voice for communications. The initial UAM ecosystem will utilize the current infrastructure such as routes, helipads, and ATC services, where practicable. ​A NASA study explored the use of existing helicopter routes in Dallas Fort Worth (DFW) airspace for initial UAM operations with a Letter of Agreement (LOA) that included procedures to request a Class B (controlled airspace) clearance. The research showed that the chosen approach was feasible for near-term, low-demand UAM traffic, but was not scalable. The growth of operations in today’s aviation system has resulted in airspace reorganization and procedures to ensure safety and efficiency as traffic rates increase. One proposed operating innovation that can help with the scalability of UAM is establishing routes and corridors. This may look similar to the Area Navigation (RNAV) procedures used today to streamline operations into busy airports. However, instead of FAA automation systems and ATC managing the flow of traffic, some UAM concepts envision a third-party service provider performing this role as part of the Provider of Services for UAM (PSU) network. The FAA’s UAM ConOps posits that new airspace structures such as UAM corridors include the following design criteria: 1) Minimal impact on existing NAS operations, 2) no or minimal additional ATC services, 3) public interest considerations such as noise, safety, and security, and 4) customer needs. The airspace available in urban environments is limited by the height of buildings, the effect of weather including wind gusts, privacy needs, and a clearance envelope. The new airspace structure would need to be designed around large airports and urban areas where the initial market demand is likely to exist. NASA has started evaluating airspace in the Dallas Fort Worth area to design new airspace structures, keeping the first two design criteria in mind. It is assumed that there will be an on-board pilot-in-command, and the flights will operate under VFR in Visual Meteorological Conditions. Corridors will be required in controlled airspace, whereas UAM operations can fly in uncontrolled Class G and E airspace using current day rules. Keeler et. al identified factors and heuristics for development of routes for UAM operations for integration with airspace close to large airports such as Dallas Fort Worth and Dallas Love Field. This paper describes the heuristics applied to define the corridors, analyzes them with respect to legacy traffic and presents key results.

Urban Air Mobility↗

Trends and 2025 Insights on the Rise of Electric Vehicles in the USA

Plug-in electric vehicles (EVs) are reshaping the transportation energy landscape, providing a practical alternative to petroleum fuels for a growing number of applications. EV sales grew 55x in the past decade (2014-2024) and 6x since 2020, driven by technological progress enabled by policies to reduce transportation emissions as well as industrial plans motivated by strategic value of EVs for global competitiveness, jobs and geopolitics. In 2024, 22% of passenger cars sold globally were EVs and opportunities for EVs beyond on-road applications are growing, including solutions to electrify off-road vehicles, maritime and aviation. This Review updates and expands our 2020 assessment of the scientific literature and describes the current status and future projections of EV markets, charging infrastructures, vehicle-grid integration and supply chains in the USA. EV is the lowest-emission motorized on-road transportation option, with life-cycle emissions decreasing as electricity emissions continue to decrease. Charging infrastructure grew in line with EV adoption but providing ubiquitous reliable and convenient charging remains a challenge. EVs are reducing electricity costs in several US markets and coordinated EV charging can improve grid resilience and reduce electricity costs for all consumers. The current trajectory of technology improvement and industrial investments points to continued acceleration of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Insights for Canadian electricity generation planning from an integrated assessment model: Should we be more cautious about hydropower cost overruns?

Hydropower accounts for approximately 60% of electricity generation in Canada, with growth expected in the coming decades as part of renewable energy transitions; however, frequent cost overruns threaten the viability of this growth. Here, using the integrated assessment model GCAM, we develop an endogenous representation of hydropower for Canada that accounts for market dynamics, thus permitting analysis of hydropower competition with other electricity generation technologies, both with and without cost overruns. Results show that modelling hydropower resources endogenously increases Canadian hydropower deployment relative to an assumption of fixed hydropower production, from 417 to 495 TWh annually by 2050. In scenarios that apply cost overruns at historical levels, hydropower loses market share to more easily scalable technologies like wind power. When including high cost overrun assumptions, the model determines that hydropower falls from about 73% to 65% of Canadian electricity generation by 2050, while wind power increases from about 8% to 11%. Countries may be better able to achieve electrification and renewable energy targets at lower cost by avoiding large-scale, overrun-prone hydropower and nuclear generation projects. Model results support that cost overruns are important considerations for policy decisions related to electricity sector development in Canada and elsewhere.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗