Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Effects of 63 MeV proton irradiation on the performance of MWIR InGaAs/InAsSb nBn photodetectors

An investigation into the effects of 63 MeV proton irradiation on high-sensitivity mid-wave infrared InGaAs/InAsSb nBn devices is performed. Three different structures with various absorber region doping profiles are irradiated and characterized to assess their impact on performance degradation. Minority carrier lifetime is measured using time-resolved photoluminescence and lifetime damage factors are assessed. The majority carrier concentration is determined via capacitance–voltage measurements and dopant introduction rates are calculated. An analysis of dark current density is performed using these material parameters, revealing a reduction in mobility with proton fluence and the emergence of a proton-induced trap energy level. Quantum efficiency is calculated at each proton fluence, and quantum efficiency damage factors show that the graded doping structure exhibits the least reduction of quantum efficiency with dose, attributed to its effective mobility enhancement. Conclusively, detector sensitivity, assessed via shot-noise limited noise-equivalent irradiance, shows that the graded doping structure is the least susceptible to high energy proton irradiation-induced performance degradation.

Physics↗

Modeling Radionuclide Inventories in MSR Off-Gas Systems with Radiochemical Transport Analysis

Molten salt reactors (MSR) contain unique characteristics that may require enhancements to modeling tools to accurately predict phenomena. One characteristic that may be advantageous to leverage during normal operation is on-line processing of the circulating fuel salt, such as an off-gas system (OGS) to remove volatile fission products. Therefore, new modeling tools must be developed to integrate spatial resolution and chemistry effects into fuel depletion tools to be able to account for these non-core sources of radioactivity. Such types of radiochemical transport analysis tools were used to estimate the removal rates for 12 elements within a flow model of the Molten Salt Reactor Experiment (MSRE) by optimizing against legacy experimental data of the gas-borne (GB) percentages of 12 nuclides. The removal rates were used in a depletion model to calculate the FP inventory that enters the MSRE OGS. Calculations are in good agreement with the empirical GB percentages reported for the 12 nuclides, which validates the approach and verifies each tool’s treatment of the radiochemical flow effects. The OGS inventory is discussed in terms of the largest nuclide contributors to activity, dose consequence, decay heat, and elemental composition. Finally, insights from the study allow recommendations to be made for future code development activities.

Shahbazi, Shayan↗

Implementation of Distributed Memory Computing in MOSAIC to Enable Large 3D Simulations of Irradiated Concrete

The concrete biological shield (CBS) of light-water reactors protects workers and the surrounding environment by absorbing neutron and gamma irradiation emitted from the reactor core. The radiation dose increases with the CBS’s operational time and, in the long term, becomes significant enough to raise the question of irradiation effects on concrete—and particularly on the structural integrity of the CBS. Irradiation-induced damage has been identified as one of the main degradation mechanisms in the CBS. Neutron radiation causes the swelling of aggregate-forming minerals at different rates and amplitudes depending on the mineral’s nature. Silicate-bearing minerals such as quartz are particularly sensitive to neutron radiation and experience up to 17.8% volumetric expansion. Aggregates comprise several minerals with different orientations and are, therefore, subject to cracking as a result of mismatch strains. Additionally, the swelling of aggregates creates significant stresses in the surrounding cement paste matrix, which also results in crack formation. In parallel with the collection of characterization and irradiation test data, development of modeling and simulation tools for irradiated concrete is ongoing with the support of the US Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) program. This effort resulted in the development and application of the fast-Fourier transform (FFT)–based code Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) at Oak Ridge National Laboratory.

61 RADIATION PROTECTION AND DOSIMETRY↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Small Particle Aerosol Exposure of African Green Monkeys to MERS-CoV as a Model for Highly Pathogenic Coronavirus Infection

Emerging coronaviruses are a global public health threat because of the potential for person-to-person transmission and high mortality rates. Middle East respiratory syndrome coronavirus (MERS-CoV) emerged in 2012, causing lethal respiratory disease in $\gg$35% of cases. Primate models of coronavirus disease are needed to support development of therapeutics, but few models exist that recapitulate severe disease. For initial development of a MERS-CoV primate model, 12 African green monkeys were exposed to 10 3 , 10 4 , or 10 5 PFU target doses of aerosolized MERS-CoV. We observed a dose-dependent increase of respiratory disease signs, although all 12 monkeys survived for the 28-day duration of the study. This study describes dosedependent effects of MERS-CoV infection of primates and uses a route of infection with potential relevance to MERSCoV transmission. Aerosol exposure of African green monkeys might provide a platform approach for the development of primate models of novel coronavirus diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation-induced vacancy injection in heterogeneous multiphase materials

Understanding the synergy between corrosion and defect dynamics is a key consideration in the development of advanced materials for extreme environments. Here, we reveal a surprising phenomenon for the transport of point defects induced by irradiation in a heterogeneous multiphase structure of a metal and an oxide, similar to that formed under metal corrosion that takes place in most environments. Despite the confinement of the produced damage within the oxide, vacancies were injected into the unirradiated metal and coarsened with dose. Furthermore, the results show that the nature of the oxide layer dictates the defect evolution in the metal layer. This work reveals an interesting mechanism for point defect interactions in multiphase materials, with broad implications in many fields, while also emphasizing the complex coupling between corrosion and irradiation. Corrosion leads to the formation of multiphase materials, while irradiation enhances diffusion within the heterogeneous phases, which can impact corrosion rates.

36 MATERIALS SCIENCE↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

A Stochastic Intracellular Model of Anthrax Infection With Spore Germination Heterogeneity

We present a stochastic mathematical model of the intracellular infection dynamics of Bacillus anthracis in macrophages. Following inhalation of B. anthracis spores, these are ingested by alveolar phagocytes. Ingested spores then begin to germinate and divide intracellularly. This can lead to the eventual death of the host cell and the extracellular release of bacterial progeny. Some macrophages successfully eliminate the intracellular bacteria and will recover. Here, a stochastic birth-and-death process with catastrophe is proposed, which includes the mechanism of spore germination and maturation of B. anthracis . The resulting model is used to explore the potential for heterogeneity in the spore germination rate, with the consideration of two extreme cases for the rate distribution: continuous Gaussian and discrete Bernoulli. We make use of approximate Bayesian computation to calibrate our model using experimental measurements from in vitro infection of murine peritoneal macrophages with spores of the Sterne 34F2 strain of B. anthracis . The calibrated stochastic model allows us to compute the probability of rupture, mean time to rupture, and rupture size distribution, of a macrophage that has been infected with one spore. We also obtain the mean spore and bacterial loads over time for a population of cells, each assumed to be initially infected with a single spore. Our results support the existence of significant heterogeneity in the germination rate, with a subset of spores expected to germinate much later than the majority. Furthermore, in agreement with experimental evidence, our results suggest that most of the spores taken up by macrophages are likely to be eliminated by the host cell, but a few germinated spores may survive phagocytosis and lead to the death of the infected cell. Finally, we discuss how this stochastic modelling approach, together with dose-response data, allows us to quantify and predict individual infection risk following exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Chapter 13: A Simple Estimation of UV Irradiance Under Clear-Sky Conditions

Accelerated aging tests are designed to estimate the useful life of products in their end-use environment. There is currently no simple way to answer the age-old question: “How long should I run my weathering test to reproduce 1 year of outdoor aging?” At the very least, there is need to (1) evaluate the acceleration rate associated with each stress factor and (2) estimate the intensity of the stress factors that the products under scrutiny are exposed to in natural aging. In this chapter, a model is introduced to calculate the ratio between ultraviolet (UV) irradiance and global horizontal irradiance (GHI). This method was empirically derived from measured or simulated irradiance data and validated against outdoor observations. This ratio provides a simple way to estimate the UV dose that samples are exposed to at any outdoor location.

ENERGY PLANNING, POLICY, AND ECONOMY,OTHER INSTRUM↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

UV-Induced Degradation and Associated Metastability in TOPCon Photovoltaic Modules: Understanding Kinetics and Cell Variance

Tunnel oxide passivated contact (TOPCon) silicon photovoltaic (PV) modules are dominating the PV market, but they may be susceptible to degradation under ultraviolet (UV)-containing light. Quantifying the impacts of UV-induced degradation (UVID) is complicated by an associated metastability causing further degradation under dark storage and rapid recovery under sunlight. Here, we study modules that have -2.3% to -3.2% nonrecoverable UVID loss after 60 kWh/m2 dose of 340 nm light and additional recoverable loss under dark storage. We use in situ electroluminescence (EL) imaging to characterize the post-UVID metastability at the module level. The cell-by-cell dark degradation and recovery kinetics span a wide range from +6% to -70% changes in EL intensity after 520 h of dark storage, which returns to +- 4% of the initial post-UVID EL intensity after illumination. The kinetics follow double exponential rates with dark storage degradation time constants of 345 and 45 h, and UV light recovery time constants of 5 min and 36 s. We propose that this is consistent with prior reports of kinetics for light-soaking metastability in Al2O3 passivation. Finally, we further show that cells having high UVID also have injection-dependent effective carrier lifetimes and significant intra-cell variance, suggesting possible origins of processing inconsistency.

14 SOLAR ENERGY↗

Nitrogen‐Nitrogen Bond Breaking in Irradiation Products of Hexanitrohexaazaisowurtzitane (CL‐20)

While the primary result of an interaction of ionizing radiation with an organic material is the ejection of electrons from molecular orbitals producing cations, the free electrons can further interact, yielding excited states; and, potentially, anions. In this work, we computed reaction barriers and energies for N−N bond breaking in the CL-20 cation, anion, and excited state to investigate if CL-20 degradation is accelerated after radiation exposure. We focused on N−N bond dissociation because it is the rate-determining step in the thermal degradation of CL-20. We found that N−N cleavage rapidly takes place in the CL-20 cation and anion with greatly reduced reaction energies as compared to CL-20. We also outlined a potential path for photodissociation of the N−N bond. While CL-20 is kinetically stable, initial degradation occurs readily in its irradiation products. In conclusion, this is of importance for the performance of the explosive after high-dose exposure and influences aging if CL-20 is irradiated at a low dose over extended periods of time.

CL-20 anion↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Competitive Metabolism of Polycyclic Aromatic Hydrocarbons (PAHs): An Assessment Using In Vitro Metabolism and Physiologically Based Pharmacokinetic (PBPK) Modeling

Humans are routinely exposed to complex mixtures such as polycyclic aromatic hydrocarbons (PAHs) rather than to single compounds, as are often assessed for hazards. Cytochrome P450 enzymes (CYPs) metabolize PAHs, and multiple PAHs found in mixtures can compete as substrates for individual CYPs (e.g., CYP1A1, CYP1B1, etc.). The objective of this study was to assess competitive inhibition of metabolism of PAH mixtures in humans and evaluate a key assumption of the Relative Potency Factor approach that common human exposures will not cause interactions among mixture components. To test this objective, we co-incubated binary mixtures of benzo[a]pyrene (BaP) and dibenzo[def,p]chrysene (DBC) in human hepatic microsomes and measured rates of enzymatic BaP and DBC disappearance. We observed competitive inhibition of BaP and DBC metabolism and measured inhibition coefficients (K i ), observing that BaP inhibited DBC metabolism more potently than DBC inhibited BaP metabolism (0.061 vs. 0.44 µM K i , respectively). We developed a physiologically based pharmacokinetic (PBPK) interaction model by integrating PBPK models of DBC and BaP and incorporating measured metabolism inhibition coefficients. The PBPK model predicts significant increases in BaP and DBC concentrations in blood AUCs following high oral doses of PAHs (≥100 mg), five orders of magnitude higher than typical human exposures. We also measured inhibition coefficients of Supermix-10, a mixture of the most abundant PAHs measured at the Portland Harbor Superfund Site, on BaP and DBC metabolism. We observed similar potencies of inhibition coefficients of Supermix-10 compared to BaP and DBC. Overall, results of this study demonstrate that these PAHs compete for the same enzymes and, at high doses, inhibit metabolism and alter internal dosimetry of exposed PAHs. This approach predicts that BaP and DBC exposures required to observe metabolic interaction are much higher than typical human exposures, consistent with assumptions used when applying the Relative Potency Factor approach for PAH mixture risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Upscaling X-ray nanoimaging to macroscopic specimens

Upscaling X-ray nanoimaging to macroscopic specimens has the potential for providing insights across multiple length scales, but its feasibility has long been an open question. By combining the imaging requirements and existing proof-of-principle examples in large-specimen preparation, data acquisition and reconstruction algorithms, the authors provide imaging time estimates for howX-ray nanoimaging can be scaled to macroscopic specimens. To arrive at this estimate, a phase contrast imaging model that includes plural scattering effects is used to calculate the required exposure and corresponding radiation dose. The coherent X-ray flux anticipated from upcoming diffraction-limited light sources is then considered. This imaging time estimation is in particular applied to the case of the connectomes of whole mouse brains. To image the connectome of the whole mouse brain, electron microscopy connectomics might require years, whereas optimized X-ray microscopy connectomics could reduce this to one week. Furthermore, this analysis points to challenges that need to be overcome (such as increased X-ray detector frame rate) and opportunities that advances in artificial-intelligence-based `smart' scanning might provide. While the technical advances required are daunting, it is shown that X-ray microscopy is indeed potentially applicable to nanoimaging of millimetre- or even centimetre-size specimens.

97 MATHEMATICS AND COMPUTING↗