Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

TH-CD-209-01: A Greedy Reassignment Algorithm for the PBS Minimum Monitor Unit Constraint

Purpose: To investigate a Greedy Reassignment algorithm in order to mitigate the effects of low weight spots in proton pencil beam scanning (PBS) treatment plans. Methods: To convert a plan from the treatment planning system’s (TPS) to a deliverable plan, post processing methods can be used to adjust the spot maps to meets the minimum MU constraint. Existing methods include: deleting low weight spots (Cut method), or rounding spots with weight above/below half the limit up/down to the limit/zero (Round method). An alternative method called Greedy Reassignment was developed in this work in which the lowest weight spot in the field was removed and its weight reassigned equally among its nearest neighbors. The process was repeated with the next lowest weight spot until all spots in the field were above the MU constraint. The algorithm performance was evaluated using plans collected from 190 patients (496 fields) treated at our facility. The evaluation criteria were the γ-index pass rate comparing the pre-processed and post-processed dose distributions. A planning metric was further developed to predict the impact of post-processing on treatment plans for various treatment planning, machine, and dose tolerance parameters. Results: For fields with a gamma pass rate of 90±1%, the metric has a standard deviation equal to 18% of the centroid value. This showed that the metric and γ-index pass rate are correlated for the Greedy Reassignment algorithm. Using a 3rd order polynomial fit to the data, the Greedy Reassignment method had 1.8 times better metric at 90% pass rate compared to other post-processing methods. Conclusion: We showed that the Greedy Reassignment method yields deliverable plans that are closest to the optimized-without-MU-constraint plan from the TPS. The metric developed in this work could help design the minimum MU threshold with the goal of keeping the γ-index pass rate above an acceptable value.

60 APPLIED LIFE SCIENCES↗

Radiation Response of Ga 2 O 3 MOSFETs Probed via Focused Particle Beams

Gallium Oxide (Ga 2 O 3 ), particularly in its β-phase, is attracting lots of interest for high-power and high-voltage electronics due to its wide bandgap, high breakdown field, and thermal stability. This study investigates the radiation response of Ga 2 O 3 Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) under Total Ionizing Dose (TID) and Displacement Damage (DD) conditions, which are critical for applications in radiation environments. Utilizing a dual-beam Focused Ion Beam and Scanning Electron Microscope setup, microscale analysis of radiation effects on individual devices is performed. The findings reveal distinct behaviors under TID and DD + TID conditions, with TID leading to threshold voltage shifts due to trapped charges, while DD results in decreased drive current attributed to increased carrier scattering from lattice defects. Notably, it is demonstrated that the TID effect can be mitigated through dynamic threshold voltage adjustments and that the predicted TID from ions calculated by Monte Carlo simulations overestimates actual TID due to unaccounted charge yield effects. In conclusion, this research enhances the understanding of Ga2O3 MOSFETs' performance in harsh radiation environments, providing insights for the design of robust electronic devices for space and nuclear applications.

MOSFET↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Prostate-Specific Antigen Bounce After High-Dose-Rate Monotherapy for Prostate Cancer

Purpose: To characterize the magnitude and kinetics of prostate-specific antigen (PSA) bounces after high-dose-rate (HDR) monotherapy and determine relationships between certain clinical factors and PSA bounce. Methods and Materials: Longitudinal PSA data and various clinical parameters were examined in 157 consecutive patients treated with HDR monotherapy between 1996 and 2005. We used the following definition for PSA bounce: rise in PSA ≥threshold, after which it returns to the prior level or lower. Prostate-specific antigen failure was defined per the Phoenix definition (nadir +2 ng/mL). Results: A PSA bounce was noted in 67 patients (43%). The number of bounces per patient was 1 in 45 cases (67%), 2 in 19 (28%), 3 in 2 (3%), 4 in 0, and 5 in 1 (1%). The median time to maximum PSA bounce was 1.3 years, its median magnitude was 0.7, and its median duration was 0.75 years. Three patients (2%) were noted to have PSA failure. None of the 3 patients who experienced biochemical failure exhibited PSA bounce. In the fully adjusted model for predicting each bounce, patients aged <55 years had a statistically significant higher likelihood of experiencing a bounce (odds ratio 2.22, 95% confidence interval 1.38-3.57, P=.001). There was also a statistically significant higher probability of experiencing a bounce for every unit decrease in Gleason score (odds ratio 1.52, 95% confidence interval 1.01-2.04, P=.045). Conclusions: A PSA bounce occurs in a significant percentage of patients treated with HDR monotherapy, with magnitudes varying from <1 in 28% of cases to ≥1 in 15%. The median duration of bounce is <1 year. More bounces were identified in patients with lower Gleason score and age <55 years. Further investigation using a model to correlate magnitude and frequency of bounces with clinical variables are under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical Dose of Internal Organs Internal Exposure - 13471

The health threat posed by radionuclides has stimulated increased efforts to developed characterization on the biological behavior of radionuclides in humans in all ages. In an effort motivated largely by the Chernobyl nuclear accident, the International Commission on Radiological Protection (ICRP) is assembling a set of age specific biokinetic models for environmentally important radioelements. Radioactive substances in the air, mainly through the respiratory system and digestive tract, is inside the body. Radioactive substances are unevenly distributed in various organs and tissues. Therefore, the degree of damage will depend not only on the dose of radiation have but also on the critical organ, which is the most accumulation of radioactive substances, which leads to the defeat of the entire human body. The main objective of radiation protection, to avoid exceeding the maximum permissible doses of external and internal exposure of a person to prevent the physical and genetic damage people. The maximum tolerated dose (MTD) of radiation is called a dose of radiation a person in uniform getting her for 50 years does not cause changes in the health of the exposed individual and his progeny. The following classification of critical organs, depending on the category of exposure on their degree of sensitivity to radiation: First group: the whole body, gonads and red bone marrow; Second group: muscle, fat, liver, kidney, spleen, gastrointestinal tract, lungs and lens of the eye; The third group: bone, thyroid and skin; Fourth group: the hands, forearms, feet. MTD exposure whole body, gonads and bone marrow represent the maximum exposures (5 rem per year) experienced by people in their normal activities. The purpose of this article is intended dose received from various internal organs of the radionuclides that may enter the body by inhalation, and gastrointestinal tract. The biokinetic model describes the time dependent distribution and excretion of different radionuclides that have intake into the organism or absorbed into blood. Transport of different radionuclides between compartments is assumed to follow first order kinetics provided the concentration in red blood cells (RBCs) stays below a nonlinear threshold concentration. When the concentration in RBCs exceeds that threshold, the transfer rate from diffusible plasma to RBCs is assumed to decrease as the concentration in RBCs increases. For the calculations used capabilities AMBER by using the traces of radionuclides in the body. Model for the transfer of radionuclides in the body has been built on the basis of existing models at AMBER for lead. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Highly Tunable Thiol-Ene Photoresins for Volumetric Additive Manufacturing

Volumetric additive manufacturing (VAM) forms complete 3D objects in a single photocuring operation without layering defects, enabling 3D printed polymer parts with mechanical properties similar to their bulk material counterparts. This study presents the first report of VAM-printed thiol-ene resins. With well-ordered molecular networks, thiol-ene chemistry accesses polymer materials with a wide range of mechanical properties, moving VAM beyond the limitations of commonly used acrylate formulations. Since free-radical thiol-ene polymerization is not inhibited by oxygen, the nonlinear threshold response required in VAM is introduced by incorporating 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO) as a radical scavenger. Tuning of the reaction kinetics is accomplished by balancing inhibitor and initiator content. Coupling this with quantitative measurements of the absorbed volumetric optical dose allows control of polymer conversion and gelation during printing. Importantly, this work thereby establishes the first comprehensive framework for spatial–temporal control over volumetric energy distribution, demonstrating structures 3D printed in thiol-ene resin by means of tomographic volumetric VAM. Mechanical characterization of this thiol-ene system, with varied ratios of isocyanurate and triethylene glycol monomers, reveals highly tunable mechanical response far more versatile than identical acrylate-based resins. This broadens the range of materials and properties available for VAM, taking another step toward high-performance printed polymers.

36 MATERIALS SCIENCE↗

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.↗

SU-E-J-50: An Evaluation of the Stability of Image Quality Parameters of the Elekta XVI and IView Imaging Systems

Introduction Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and MV mode. Methods and Materials: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For XVI CBCT, Head and Neck Small20 (S20) and Pelvis Medium20 (M20) standard acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution and HU constancy. Dose and kVp for the XVI were recorded using the Unfors RaySafe Xi system with the R/F Low Detector for the kV planar radiographic mode. Results A total of 20 and 10 measurements were acquired for the planar radiographic and CBCT systems respectively over a two month period. Values were normalized to the mean and the standard deviations (STD) were recorded. For the planar radiographic spatial resolution, the STD for f30, f40, f50 were 0.004, 0.002, 0.002 and 0.005, 0.007, 0.008 for the kV and MV, respectively. The average recorded dose for kV was 38.7±2.7 μGy. The STD of the evaluated metrics for the S20 acquisition were: 0.444(f30), 0.067(f40), 0.062(f50), 0.018(Water/poly-HU constancy), 0.028(uniformity) and 0.106(noise). The standard deviations for the M20 acquisition were: 0.108(f30), 0.073(f40), 0.091(f50), 0.008(Water/poly-HU constancy), 0.005(uniformity) and 0.005(noise). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Elekta XVI and iView imaging systems. Consistent imaging and dosimetric properties over the evaluated time frame were noted. This work was funded in part by the Cancer Prevention Research Institute of Texas Pre doctoral fellowship training grant (RP140105) to Dennis N. Stanley M.Sc.

60 APPLIED LIFE SCIENCES↗

Biosensors for the detection of chorismate and cis,cis -muconic acid in Corynebacterium glutamicum

Abstract Corynebacterium glutamicum ATCC 13032 is a promising microbial chassis for industrial production of valuable compounds, including aromatic amino acids derived from the shikimate pathway. In this work, we developed two whole-cell, transcription factor based fluorescent biosensors to track cis,cis-muconic acid (ccMA) and chorismate in C. glutamicum. Chorismate is a key intermediate in the shikimate pathway from which value-added chemicals can be produced, and a shunt from the shikimate pathway can divert carbon to ccMA, a high value chemical. We transferred a ccMA-inducible transcription factor, CatM, from Acinetobacter baylyi ADP1 into C. glutamicum and screened a promoter library to isolate variants with high sensitivity and dynamic range to ccMA by providing benzoate, which is converted to ccMA intracellularly. The biosensor also detected exogenously supplied ccMA, suggesting the presence of a putative ccMA transporter in C. glutamicum, though the external ccMA concentration threshold to elicit a response was 100-fold higher than the concentration of benzoate required to do so through intracellular ccMA production. We then developed a chorismate biosensor, in which a chorismate inducible promoter regulated by natively expressed QsuR was optimized to exhibit a dose-dependent response to exogenously supplemented quinate (a chorismate precursor). A chorismate–pyruvate lyase encoding gene, ubiC, was introduced into C. glutamicum to lower the intracellular chorismate pool, which resulted in loss of dose dependence to quinate. Further, a knockout strain that blocked the conversion of quinate to chorismate also resulted in absence of dose dependence to quinate, validating that the chorismate biosensor is specific to intracellular chorismate pool. The ccMA and chorismate biosensors were dually inserted into C. glutamicum to simultaneously detect intracellularly produced chorismate and ccMA. Biosensors, such as those developed in this study, can be applied in C. glutamicum for multiplex sensing to expedite pathway design and optimization through metabolic engineering in this promising chassis organism. One-Sentence Summary High-throughput screening of promoter libraries in Corynebacterium glutamicum to establish transcription factor based biosensors for key metabolic intermediates in shikimate and β-ketoadipate pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Proton irradiation energy dependence of dc and rf characteristics on InAlN/GaN high electron mobility transistors

The effects of proton irradiation energy on dc and rf characteristics of InAlN/GaN high electron mobility transistors (HEMTs) were investigated. A fixed proton dose of 51015 cm2 with 5, 10, and 15 MeV irradiation energies was used in this study. For the dc characteristics, degradation was observed for sheet resistance, transfer resistance, contact resistivity, saturation drain current, maximum transconductance, reverse-bias gate leakage current, and sub-threshold drain leakage current for all the irradiated HEMTs; however, the degree of the degradation was decreased as the irradiation energy increased. Similar trends were obtained for the rf performance of the devices, with 10% degradation of the unity gain cut-off frequency (fT) and maximum oscillation frequency ( fmax) for the HEMTs irradiated with 15 MeV protons but 30% for 5 MeV proton irradiation. The carrier removal rate was in the range 0.66 1.24 cm1 over the range of proton energies investigated

36 MATERIALS SCIENCE↗

A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer

Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRI intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Factors for Radiation Pneumonitis in Hodgkin Lymphoma Patients Receiving Combined-Modality Therapy

Purpose: This study sought to quantify the risk of radiation pneumonitis (RP) in Hodgkin lymphoma (HL) patients receiving mediastinal radiation therapy (RT) and to identify predictive factors for RP. Methods and Materials: We identified 75 patients with newly diagnosed HL treated with mediastinal RT and 17 patients with relapsed/refractory HL treated with mediastinal RT before or after transplant. Lung dose-volumetric parameters including mean lung dose and percentage of lungs receiving 20 Gy were calculated. Factors associated with RP were explored by use of the Fisher exact test. Results: RP developed in 7 patients (10%) who received mediastinal RT as part of initial therapy (Radiation Therapy Oncology Group Grade 1 in 6 cases). A mean lung dose of 13.5 Gy or greater (p = 0.04) and percentage of lungs receiving 20 Gy of 33.5% or greater (p = 0.009) significantly predicted for RP. RP developed in 6 patients (35%) with relapsed/refractory HL treated with peri-transplant mediastinal RT (Grade 3 in 4 cases). Pre-transplant mediastinal RT, compared with post-transplant mediastinal RT, significantly predicted for Grade 3 RP (57% vs. 0%, p = 0.015). Conclusions: We identified threshold lung metrics predicting for RP in HL patients receiving mediastinal RT as part of initial therapy, with the majority of cases being of mild severity. The risk of RP is significantly higher with peri-transplant mediastinal RT, especially among those who receive pre-transplant RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Activation estimates of the RHIC beam dump

In anticipation of the expiration of the RHIC ASE in December 2025 and the need to demonstrate compliance with nuclear facility rule (10CFR830), this study quantifies the radionuclide inventory and respective activity at the beam dumps by simulating a period of five years of operation using conservative assumptions. Simulations were performed with the Monte Carlo particle transport and interaction code FLUKA and its dosimetry results were compared with measured dose rate data, showing good agreement. The beam dump was deemed to constitute the main hotspot of residual radiation and also representative of a worst case scenario in terms of induced activation. The activation levels calculated indicate that the RHIC tunnel will be well below the thresholds of a DOE’s category-3 nuclear facility classification.

43 PARTICLE ACCELERATORS↗

Production of Mg and Al Auger electrons by noble gas ion bombardment of Mg and Al surfaces

Relative production efficiencies of Mg and Al Auger electrons by He, Ne, Ar, Kr, and Xe ion bombardment are reported as a function of ion energy for energies not exceeding 3 keV. The experimental apparatus employed consisted of a LEED-Auger system equipped with an ion gun and a four-grid retarding-potential analyzer. It is found that: (1) the shape of the ion-excited Auger signal was independent of the rare gas and quite symmetric; (2) the Al signal was about an order of magnitude smaller than the Mg signal for a given bombarding species and ion-gun voltage; (3) no signal was observed for He(+) bombardment under any of the experimental conditions; (4) signal strengths were independent of temperature and ion dose; (5) the Auger production efficiencies differed by no more than a factor of two among the different gases - except for He(+) - on a given metal; (6) all the signal strengths increased with increasing ion-gun voltage, with no maximum exhibited; and (7) the apparent threshold energy for the Al signal was higher than that for the Mg signal. The differences between the results for the two metals are attributed to the fact that the Al 2p orbital lies deeper in energy and closer to the nucleus than the corresponding Mg orbital.

Ferrante, J.↗

Experiences from Implementing Waste Led Decommissioning in Practice at a Research Facility - 17216

The decommissioning of MAX-lab (a national accelerator laboratory hosted by Lund University) has been performed using a risk-based concept for dismantling of the equipment and clearance measurement of the facility. To support the concept, a radiological characterisation was performed containing scintillation and dose rate measurements as well as nuclide vector determination based on nuclide specific analysis of the activity content in material samples. This paper describes the decommissioning at MAX-lab, performed during 2015 and 2016. Dismantled waste was sent to the Studsvik site for treatment. Clearance measurements of material were performed at MAX-lab and at the Studsvik site. The levels of activity have been compared with the threshold values in the Swedish clearance regulations (material or buildings for free use) and the detected levels are below the limits for clearance of material with some exceptions. Activity above the clearance levels were found in a few locations in the facility. After removal of installations and small amounts of building structures at these locations clearance of the facility is possible. Keywords: Risk based approach, fast decommissioning, on- and offsite material clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pion Production Data Needed for Space Radiation

A recent discovery concerning the importance of hadron production in space radiation is that pions can contribute up to twenty percent of the dose from galactic cosmic ray interactions (S. Aghara, S. Blattnig, J. Norbury, R. Singleterry, Nuclear Instruments and Methods, Vol. 267, 2009, p. 1115). Although the contribution for dose equivalent will be smaller, the dose contribution could be important for fluence based radiation models. Pion production cross sections will be an essential ingredient to such models, and it is of interest to investigate the adequacy of the pion production experimental data base for energies relevant to space radiation. The pion production threshold in nucleon - nucleon reactions is at 280 MeV and, in an interesting accident of nature, this lies near the peak of the galactic cosmic ray proton spectrum. Therefore, pion production data are needed from threshold up to energies around 50 GeV/nucleon, where the galactic cosmic ray fluence is of decreasing importance. Total and differential cross section data for pion production in this energy range will be reviewed. The availability and accuracy of theoretical models will also be discussed. It will be shown that there are a significant lack of data in this important energy range and that theoretical models still need improvement.

Norbury, John W.↗

Subthreshold Erosion of an Organic Polymer Induced by Multiple Shots of an X-Ray Free-Electron Laser

We report solids irradiated by energetic photons can be eroded in two modes, depending on the radiation intensity. High average, low-peak power sources, e.g., synchrotron radiation and high-order harmonics, induce desorption of the material at a low etch rate. In contrast, high-peak-power radiation from extreme ultraviolet and x-ray lasers usually causes a massive removal of the material even by a single shot. In this contribution, an effective material erosion is reported in PMMA exposed to multiple accumulated pulses generated by the free-electron x-ray-laser Linac Coherent Light Source (LCLS, tuned at a photon energy of 830 eV in this study, operated in Menlo Park at Stanford, CA, USA) at a fluence below the single-pulse ablation threshold. The effect is caused by polymer-chain scissions initiated by single photons carrying enough energy to break the C—C bounds. High efficiency of the erosion is supposed to occur due to a correlation of the single-photon effects. The subthreshold damage exhibits a nonlinear dose dependence resulting from a competition between chain scissions and cross-linking processes. The cross-linking is proven by Raman spectroscopy of the irradiated polymer. Two theoretical models of the x-ray free-electron-laser-induced erosion are suggested, which provide an excellent agreement with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating Tumor Response of Non-Small Cell Lung Cancer Patients With {sup 18}F-Fludeoxyglucose Positron Emission Tomography: Potential for Treatment Individualization

Objective: To assess early tumor responsiveness and the corresponding effective radiosensitivity for individual patients with non-small cell lung cancer (NSCLC) based on 2 successive {sup 18}F-fludeoxyglucose positron emission tomography (FDG-PET) scans. Methods and Materials: Twenty-six NSCLC patients treated in Maastricht were included in the study. Fifteen patients underwent sequential chemoradiation therapy, and 11 patients received concomitant chemoradiation therapy. All patients were imaged with FDG before the start and during the second week of radiation therapy. The sequential images were analyzed in relation to the dose delivered until the second image. An operational quantity, effective radiosensitivity, α{sub eff}, was determined at the voxel level. Correlations were sought between the average α{sub eff} or the fraction of negative α{sub eff} values and the overall survival at 2 years. Separate analyses were performed for the primary gross target volume (GTV), the lymph node GTV, and the clinical target volumes (CTVs). Results: Patients receiving sequential treatment could be divided into responders and nonresponders, using a threshold for the average α{sub eff} of 0.003 Gy{sup −1} in the primary GTV, with a sensitivity of 75% and a specificity of 100% (P<.0001). Choosing the fraction of negative α{sub eff} as a criterion, the threshold 0.3 also had a sensitivity of 75% and a specificity of 100% (P<.0001). Good prognostic potential was maintained for patients receiving concurrent chemotherapy. For lymph node GTV, the correlation had low statistical significance. A cross-validation analysis confirmed the potential of the method. Conclusions: Evaluation of the early response in NSCLC patients showed that it is feasible to determine a threshold value for effective radiosensitivity corresponding to good response. It also showed that a threshold value for the fraction of negative α{sub eff} could also be correlated with poor response. The proposed method, therefore, has potential to identify candidates for more aggressive strategies to increase the rate of local control and also avoid exposing to unnecessary aggressive therapies the majority of patients responding to standard treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗