Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Isotope-selective radiography and material assay using high-brilliance, quasi-monochromatic, high-energy photons

We demonstrate the possibility to directly detect microgram amounts of the isotope 7 Li using a quasi-monochromatic high-energy photon beam. The isotope selective detection is based on a witness scatterer absorbing and re-emitting photons via nuclear resonance fluorescence. This enables the detection of isotopes with microgram accuracy at long distances from the actual sample. Further, we demonstrate that the technique can deliver quantitative information without specific knowledge of the photon flux and no spectral capabilities or knowledge of the resonance fluorescence cross section. Detection of low-atomic-weight isotopes screened by heavy shielding is also shown. The techniques described are applicable to all next-generation, ultrahigh brilliance, laser-Compton light sources currently under construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed domain coherent link with electrically reconfigurable IMDD and coherent modes for O-band data center applications

We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.

Misak, Stephen (ORCID:0000000154973084)↗

Scaling comb-driven resonator-based DWDM silicon photonic links to multi-Tb/s in the multi-FSR regime

The use of chip-based micro-resonator Kerr frequency combs in conjunction with dense wavelength-division multiplexing (DWDM) enables massively parallel intensity-modulated direct-detection data transmission with low energy consumption. Resonator-based modulators and filters used in such systems can limit the number of usable wavelength channels due to practical constraints on the maximum achievable free spectral range (FSR). In this work, we introduce the design of multi-Tb/s comb-driven resonator-based silicon photonic links by leveraging the multi-FSR regime. We demonstrate the viability of the link architecture with yield estimates that are supported by extensive wafer-scale measurements of 704 micro-resonators fabricated in a commercial complementary metal–oxide–semiconductor foundry. We show that a 2.80 Tb/s link is realizable with a ≥6 σ yield (∼99.999%), and that aggregate bandwidths of 3.76 Tb/s and 4.72 Tb/s are possible if yield targets are relaxed (3 σ and 1 σ , respectively). All designs represent a 1.94−3.28× boost to aggregate link bandwidth while maintaining BER≤10 −10 performance, with a theoretical bandwidth of 10.51 Tb/s being possible for sufficiently robust resonators. We use high-speed BER measurements to inform co-optimization of data rate and aggressor spacing ( λ ag ), limiting any additional loss-based power penalties to off-resonance insertion loss (IL) and routing loss. This work demonstrates that, through the multi-FSR regime, there is a clear path toward Kerr comb-driven ultra-broadband, high bandwidth silicon photonic links that can support next-generation data centers and high-performance computers.

James, Aneek (ORCID:0000000262527807)↗

Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Characterizing complex impedance in TES Detectors for SuperCDMS

Dark Matter composes 70% of all matter in the universe and traces out the large-structure of the universe. The SuperCDMS detector attempts to directly detect thermal relic dark matter, probing down to 300MeV through nucleus scattering and 500keV through electron scattering. To accomplish this we make use of Transition Edge Sensors (TES). TES-based detectors sit in the transition regime between acting as a superconductor or a normal conductor. As particles hit the detector, they heat it changing the impedance. To characterize this process we measure the impedance at multiple DC bias points (Figure 3) and multiple temperatures (Figures 5, 6).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Colloid-Facilitated Actinide Transport in a Cementitious-Impacted SRS Groundwater

The objective of this report is to provide a literature review relevant to the question of whether colloid facilitated transport of plutonium is enhanced in a cementitious groundwater system on the Savannah River Site (SRS). Contaminant transport is commonly described as taking place in a system with a mobile aqueous phase and an immobile solid phase. There has been an increasing awareness of a third phase, a mobile solid phase, also referred to as a mobile colloidal phase. Mobile colloids consist of organic and/or inorganic submicron-particles that move with groundwater flow. When radionuclides are associated with the mobile colloids, the net effect is that radionuclides can move faster through the subsurface system than would be predicted by transport models that do not include mobile colloids. It is important to distinguish between subsurface colloids and subsurface mobile colloids. The subsurface environment includes an enormous reservoir of colloids, but only a tiny fraction, if any, are mobile. Mobile colloid formation is commonly described as involving a three-step process: genesis, stabilization, and transport. It was concluded that there is a strong likelihood that submicron colloids of plutonium exist near the source term, (i.e., the genesis step is likely completed). While such particles have not been directly detected, it is highly likely that plutonium could either attach to submicron particles in the sediment or that submicron plutonium fragments exist at the source. However, the tendency for these plutonium colloids to move in the SRS subsurface is extremely low, especially in engineered cementitious environments where the ionic strength of the solution and the elevated concentrations of divalent cations greatly curtails colloid suspension stability (i.e., the stabilization step is likely not completed). Together these data strongly indicate that plutonium-bearing colloids would likely exist in the near field of a tank closure facility, but the colloids would be unlikely to be mobile, thereby providing a vector for enhanced transport. Under cementitious leachate impacted groundwater conditions, it is reasonable to assume plutonium transport occurs primarily as a two-phase system, a mobile aqueous phase and an immobile solid phase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Acceleration of Outcomes in Physics: Final Report for the Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Umbrella Project

The Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Initiative addresses the first question by supporting experiments that would directly detect dark matter when it interacts with very sensitive detectors. There are two leading candidates for dark matter that are plausibly detectable in terrestrial searches: axions and weakly-interacting massive particles, or WIMPs. Early NPAC investments supported PNNL involvement in the Axion Dark Matter eXperiment (ADMX), which has produced the world’s most sensitive axion search to date. Work associated with the current generation of the experiment is funded by the DOE Office of High Energy Physics (HEP), while R&D toward future searches for higher mass axions proceeds under NPAC. Likewise, early NPAC support for WIMP searches has graduated to the HEP-supported Super Cold Dark Matter Search (SuperCDMS) experiment. SuperCDMS has produced world-leading limits on potential WIMP candidates as well as a number of other exotic candidates and processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PID Temperature Controller Autotuning for Skipper-CCDs

Proportional-integral-derivative (PID) temperature control of Skipper-CCDs is important for dark matter direct-detection experiments, e.g., SENSEI@MINOS. The project goal is to create an autotuned PID controller in Python to replace expensive Lake Shore temperature controllers.

Jones, Evan↗

DarkNESS Project Testing

This internship involved the design and assembly of a mechanical system for testing skipper-Charge Couple Devices (CCDs) for the DarkNESS project. Skipper-CCDs are highly-sensitive sensors with ultra-low readout noise that are deployed for direct detection of dark matter. DarkNESS is a CubeSat that aims to use skipper CCDs to search for dark matter decaying into X-rays. Currently, in the testing phase, the design process involved creating 3D models of mechanical adapters to operate a prototype space Multi Chip Module (sMCM) package in existing testing chambers in the CCD lab at Fermilab's IERC. The drawings were sent out to be machined, and while waiting to receive the finished adapters, we assembled a vacuum chamber for skipper-CCD testing and performed initial testing of a single CCD controlled by the space Low Threshold Acquisition (sLTA) board that will be employed on the CubeSat. The results showed that the testing conditions are optimal for data to start being taken and analyzed.

Akouedjinoude, Kodjo↗

Abbreviated Technical Report: Experimentally Interrogating Detonation Chemistry on Sub-Nanosecond to Nanosecond Timescales

Direct experimental measurement of chemical reactions during high explosive detonation remains challenging. Theory and modeling have long preceded experiment in the fundamental physical and chemical kinetic properties of detonation, and experimentation at the relevant timescales are needed to both validate models and provide fundamental understanding of detonation. In this LDRD-ER project, two approaches, x-ray diffraction and core-level x-ray Raman, were developed and used to further experimental capabilities to address this gap. We further developed dynamic x-ray diffraction to directly detect nanodiamond formation during detonation, providing experimental data towards resolving longstanding controversy in the scientific literature, and although the full kinetics have not yet been fully mapped, diamond diffraction appears on the same timescales as detonation soot formation. In the second research thrust, we have developed core-level x-ray Raman for use with high explosives. This technique provides information analogous to x-ray absorption spectroscopy and electron energy loss spectroscopy, but uses inelastic scattering of hard x-rays that can interrogate chemistry around light elements much deeper into the material. The low cross section and requisite high solid angle collection have hindered its use for ultra-fast spectroscopy. We developed and tested a high-q spectrometer which will substantially increase cross section and signal-to-noise, showing this method will also not dramatically alter, compared to x-ray absorption, the most discriminating spectral features of C, N, and O from various high explosives and expected detonation products. We have also used x-ray Raman combined with OCEAN electronic structure calculations to explore dynamic photodegradation mechanisms in PETN and CL-20 explosives. This provides a pathway towards implementing capability to dynamically explore chemistry at an x-ray free electron laser.

36 MATERIALS SCIENCE↗

Examination of Exogenous and Endogenous Irradiation Effects on PuO2 and its Precursors via EPR Spectroscopy

The spectroscopic examination of actinide compounds are of con-siderable interest for elucidating the role of 5f electrons in chemical bonding. For example, this could be directly detected via EPR spectroscopy through the hyperfine interaction of an unpaired Pu electron with a given ligand. However, typically fast spin-lattice re-laxation times [1] require the use of low temperatures, multiplying the difficulty of working with radio-toxic Pu compounds. Instead, we looked for radicals at room temperature produced from endoge-nous α-decay or exogenous γ-irradiation. PuO2 and its precursor PuIII2(C2O4)3∙nH2O were used as examples because of their ubiquity in the literature.

Kinyon, Jared S.↗

Computational Tool for Cosmic Ray Flux and Cosmogenic Activation Production Rates

Silicon charge couple devices (CCDs) are used in direct detection dark matter searches. Silicon can be obtained with very high purity and negligible amounts of radioactive contaminants. However, silicon exposed to cosmic rays can be activated, leading to the buildup of radioactive isotopes such as tritium. The decay of tritium can produce signals that cannot be distinguished from the expected signals of dark matter interactions and tritium produced by cosmic rays is expected as one of the leading sources of background for next-generation experiments. The cosmic ray flux depends on variables such as geomagnetic latitude and longitude, atmospheric depth/altitude, solar activity, and surrounding environment for example. The goal of this work is to create a tool that will evaluate the total cosmic ray exposure and related tritium production rate for any given exposure history of a silicon detector. EXcel-based Program for calculation Atmospheric Cosmic-ray Spectrum (EXPACS) was used to obtain the cosmic ray fluxes. We have worked on creating a 3-dimensional gird that spans latitude, longitude, and altitude, and can be used to interpolate the cosmic ray flux at any given location. This computation tool additionally has use for work requiring knowledge of the cosmic ray flux at multiple locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetic Inductance Phonon-Mediated Detectors for Dark Matter: R&D at NEXUS

Superconducting thin films have long been used as phonon sensors, particularly in the field of dark matter (DM) direct detection, due to the meV-scale Cooper-pair binding energy. A novel class of these detectors based on microwave kinetic inductance detectors, dubbed Kinetic Inductance Phonon-Mediated Detectors (KIPMDs), offers an attractive architecture for microcalorimeters to probe DM down to the fermionic thermal relic mass limit of a few keV. Such a device featuring an aluminum resonator patterned onto a silicon substrate was operated at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. With this device we have demonstrated a resolution on the energy absorbed by the superconductor of 2.5 eV, a factor of two better than current state-of-the-art. In this talk, I will present our measurement of the energy resolution and phonon collection efficiency performed by exposing the bare substrate to a pulsed source of 470 nm photons. I will also discuss the path forward to obtaining in these devices the sub-eV resolution required to test the “Freeze-in” class of DM models. Finally, I will review other complementary efforts in our group to develop a superconducting qubit-based low-threshold detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗