Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Determination of significance in Ecological Impact Assessment: Past change, current practice and future improvements

Ecological Impact Assessment (EcIA) is an important tool for conservation and achieving sustainable development. 'Significant' impacts are those which disturb or alter the environment to a measurable degree. Significance is a crucial part of EcIA, our understanding of the concept in practice is vital if it is to be effective as a tool. This study employed three methods to assess how the determination of significance has changed through time, what current practice is, and what would lead to future improvements. Three data streams were collected: interviews with expert stakeholders, a review of 30 Environmental Statements and a broad-scale survey of the United Kingdom Institute of Ecology and Environmental Management (IEEM) members. The approach taken in the determination of significance has become more standardised and subjectivity has become constrained through a transparent framework. This has largely been driven by a set of guidelines produced by IEEM in 2006. The significance of impacts is now more clearly justified and the accuracy with which it is determined has improved. However, there are limitations to accuracy and effectiveness of the determination of significance. These are the quality of baseline survey data, our scientific understanding of ecological processes and the lack of monitoring and feedback of results. These in turn are restricted by the limited resources available in consultancies. The most notable recommendations for future practice are the implementation of monitoring and the publication of feedback, the creation of a central database for baseline survey data and the streamlining of guidance. - Highlights: Black-Right-Pointing-Pointer The assessment of significance has changed markedly through time. Black-Right-Pointing-Pointer The IEEM guidelines have driven a standardisation of practice. Black-Right-Pointing-Pointer Currently limited by quality of baseline data and scientific understanding. Black-Right-Pointing-Pointer Monitoring and feedback would rapidly improve practice.

54 ENVIRONMENTAL SCIENCES↗

Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

Kavousian, A↗

A novel method to determine air leakage in heat pump clothes dryers

A heat pump clothes dryer offers the potential to save a significant amount of energy as compared with conventional vented electric dryers. Although heat pump clothes dryers (HPCD) offer higher energy efficiency; it has been observed that they are prone to air leakages, which inhibits the HPCD's gain in efficiency. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The basis of this method is the American Society of Testing and Materials (ASTM) standard E779 10, which is used to determine air leakage area in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. Easily accessible leakage points were quantified: the front and back crease (in the dryer drum), the leakage in the dryer duct, the air filter, and the remaining leakage in the drum. The procedure allows investigators to determine major components contributing to leakage in HPCDs, thus improving component design features that result in more efficient HPCD systems.

42 ENGINEERING↗

Improving biodiesel monoglyceride determination by ASTM method D6584-17

Biodiesels produced from commercial and non-traditional feedstocks were analyzed by ASTM D6584-17 for monoglyceride (monoacylglycerol, or MG) content. It was found that D6584-17 as currently written may not accurately determine MGs from conventional feedstocks due to significant differences in retention time using modern instrumentation. For biodiesel from non-traditional feedstocks, D6584-17 did not sufficiently account for MGs containing fatty acids outside of C16 and C18 species. This led to under- and over-reporting of MGs, as critical components were not accurately measured. Improvements to the method were made through a three-step process. First, a standard mixture of MGs was run to determine the retention time of individual MGs that could be present in the samples from C10 to C24. An additional analysis for the fatty acid methyl ester (FAME) profile was used to determine the major MG species present in the biodiesel samples, using the assumption that the MG profile was proportional to the FAME profile. The biodiesel samples were analyzed by D6584-17, and the MGs were identified using retention time matching, based on the major species expected from measuring the FAME profile. Here, by combining these two methods, the accuracy of MG determination by D6584-17 was improved for biodiesels prepared from all feedstocks.

30 DIRECT ENERGY CONVERSION↗

Tumor Volume and Metabolism of Prostate Cancer Determined by Proton Magnetic Resonance Spectroscopic Imaging at 3T Without Endorectal Coil Reveal Potential Clinical Implications in the Context of Radiation Oncology;Prostate cancer; Magnetic resonance spectroscopic imaging; Radiation oncology; Tumor volume; Biomarkers

Purpose: To determine whether a relationship exists between the tumor volume (TV) or relative choline content determined using magnetic resonance spectroscopy imaging (MRSI) at 3T and the clinical prognostic parameters for patients with localized prostate cancer (PCa). Methods and Materials: A total of 72 men (mean age, 67.8 {+-} 6.2 years) were stratified as having low-risk (n = 26), intermediate-risk (n = 24), or high-risk (n = 22) PCa. MRSI was performed at 3T using a phased-array coil. Spectra are expressed as the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamines plus creatine/citrate ratios. The mean ratio of the most pathologic voxels and the MRSI-based TV were also determined. Results: The mean values of the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamine plus creatine/citrate ratios were greater for Stage T2b or greater tumors vs. Stage T2a or less tumors: 7.53 {+-} 13.60 vs. 2.31 {+-} 5.65 (p = .018), 8.98 {+-} 14.58 vs. 2.56 {+-} 5.70 (p = .016), and 10.32 {+-} 15.47 vs. 3.55 {+-} 6.16 (p = .014), respectively. The mean MRSI-based TV for Stage T2b or greater and Stage T2a or less tumors was significantly different (2.23 {+-} 2.62 cm{sup 3} vs. 1.26 {+-} 2.06 cm{sup 3}, respectively; p = .030). This TV correlated with increased prostate-specific antigen levels (odds ratio, 1.293; p = .012). Patients with high-risk PCa had a larger TV than did the patients with intermediate-risk PCa. A similar result was found for the intermediate-risk group compared with the low-risk group (odds ratio, 1.225; p = .041). Conclusion: Biomarkers expressing the relative choline content and TV were significant parameters for the localization of PCa and could be helpful for determining the prognosis more accurately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and Dosimetric Approach to Determine Probability of Late Cardiac Mortality in Left Tangential Breast Irradiation: Comparison Between Wedged Beams and Field-in-Field Technique

Purpose: To evaluate the probability of late cardiac mortality resulting from left breast irradiation planned with tangential fields and to compare this probability between the wedged beam and field-in-field (FIF) techniques and to investigate whether some geometric/dosimetric indicators can be determined to estimate the cardiac mortality probability before treatment begins. Methods and Materials: For 30 patients, differential dose-volume histograms were calculated for the wedged beam and FIF plans, and the corresponding cardiac mortality probabilities were determined using the relative seriality model. As a comparative index of the dose distribution uniformity, the planning target volume (PTV) percentages involved in 97-103% of prescribed dose were determined for the two techniques. Three geometric parameters were measured for each patient: the maximal length, indicates how much the heart contours were displaced toward the PTV, the angle subtended at the center of the computed tomography slice by the PTV contour, and the thorax width/thickness ratio. Results: Evaluating the differential dose-volume histograms showed that the gain in uniformity between the two techniques was about 1.5. With the FIF technique, the mean dose sparing for the heart, the left anterior descending coronary artery, and the lung was 15% (2.5 Gy vs. 2.2 Gy), 21% (11.3 Gy vs. 9.0 Gy), and 42% (8.0 Gy vs. 4.6 Gy) respectively, compared with the wedged beam technique. Also, the cardiac mortality probability decreased by 40% (from 0.9% to 0.5%). Three geometric parameters, the maximal length, angle subtended at the center of the computed tomography slice by the PTV contour, and thorax width/thickness ratio, were the determining factors (p = .06 for FIF, and p = .10 for wedged beam) for evaluating the cardiac mortality probability. Conclusion: The FIF technique seemed to yield a lower cardiac mortality probability than the conventional wedged beam technique. However, although our study demonstrated that FIF technique improved the dose coverage of the PTV, the restricted number of patients enrolled and the short follow-up did not allow us to evaluate and compare the breast cancer survival rates of the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anti-symmetric barron functions and their approximation with sums of determinants

A fundamental problem in quantum physics is to encode functions that are completely anti-symmetric under permutations of identical particles. The architecture of neural network models for the electron wave function typically comprises an equivariant component followed by a summation of determinants. The recently introduced Generic Antisymmetric (GA) block is designed to enhance the expressivity of such neural wave functions, and it was found that the 2-layer GA block achieved more accurate energies than the corresponding single-determinant FermiNet architecure, suggesting its promise as a way to improve the expressivity of neural wave functions. In this paper we show how the function expressed by the 2-layer GA block can be decomposed into a sum of determinants. We formalize this result by defining the antisymmetric Barron space as a generalized version of the 2-layer GA block and providing an appromation theorem for this function class. This result can be viewed as a negative result showing that the 2-layer GA block is not more expressive than using multiple determinants.

Abrahamsen, Nilin↗

Atomistic determination of Peierls barriers of dislocation glide in nickel

The Peierls barrier measures the lattice resistance to dislocation glide in crystalline solids. We use the nudged elastic band (NEB) method to calculate the Peierls barriers for screw and edge dislocation glide in a face-centered cubic (FCC) metal of Ni. The minimum energy paths (MEPs) across single or sequential Peierls barriers are determined under shear loading. The NEB results show the decreasing Peierls barrier with increasing shear stress, giving the Peierls stress at which the Peierls barrier vanishes. The effects of boundary condition and system size on Peierls barriers are studied by comparing strain- and stress-controlled NEB results. Furthermore, the free-end NEB methods are applied to determine MEPs with improved computational efficiency. The NEB results are also used to evaluate the energetic driving force of dislocation glide, which is consistent with that determined from the Peach-Koehler force. The accuracy of the present NEB results based on an empirical interatomic potential is assessed by comparison with a machine-learning potential. This work demonstrates the robust and efficient quantification of Peierls barriers to dislocation glide in an FCC metal, and it lays a solid foundation for the atomistic determination of Peierls barriers in compositionally complex alloys with the FCC structure in future studies.

42 ENGINEERING↗

Investigation on pseudosymmetry, twinning and disorder in crystal structure determinations: Ba(H{sub 2}O)M{sub 2}{sup III}[PO{sub 3}(OH)]{sub 4} (M=Fe, V) as examples

Twinning commonly occurs in monoclinic crystals with dimensionally similar a and c axes and results in pseudo-orthorhombic symmetries with overlapping diffractions. For example, twinning in the new synthetic compound Ba(H{sub 2}O)Fe{sub 2}[PO{sub 3}(OH)]{sub 4}, which varies in space group from P2{sub 1} to P2{sub 1}/c with approximately equal a and c axial lengths, gives rise to a pseudosymmetry of C222{sub 1}. Similarly, the related compound Ba(H{sub 2}O)V{sub 2}[PO{sub 3}(OH)]{sub 4} is commonly twinned and varies in space groups as well, arising from ordered to disordered distributions of the barium cations and water molecules in the cavities. Moreover, analyses of these and other twinned structures show that the small average standard uncertainty of bond distances is a sensitive criterion for structure determinations, especially for those involving crystal twinning as well as order-disorder. A proper structure determination leads to small standard uncertainties of the atomic displacement parameters, which further result in the small standard uncertainties of bond distances. - Graphical abstract: Ba(H{sub 2}O)M{sub 2}{sup III}[PO{sub 3}(OH)]{sub 4} (M=Fe, V) varies in space group from P2{sub 1} to P2{sub 1}/c, arising from ordered to disordered distributions of Ba{sup 2+} and H{sub 2}O in the cavities. Highlights: Black-Right-Pointing-Pointer Twinning commonly occurs in monoclinic crystals with a Almost-Equal-To c. Black-Right-Pointing-Pointer Overlapping diffractions from twin domains hamper with the determination of real space groups. Black-Right-Pointing-Pointer Conventional criteria for evaluating the real space groups are not effective in this case. Black-Right-Pointing-Pointer Small standard uncertainty of bond distances is proposed as a sensitive criterion. Black-Right-Pointing-Pointer Using this criterion we determined the order-disorder structures of Ba(H{sub 2}O)M{sub 2}{sup III}[PO{sub 3}(OH)]{sub 4} (M=Fe, V) from twinned crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetocrystalline interactions and oxidation state determination of Mn{sub (2−x)}V{sub (1+x)}O{sub 4} (x=0, 1/3 and 1) magnetorresistive spinel family

Oxidation states of transition metal cations in spinels-type oxides are sometimes extremely difficult to determine by conventional spectroscopic methods. One of the most complex cases occurs when there are different cations, each one with several possible oxidation states, as in the case of the magnetoresistant Mn{sub (2−x)}V{sub (1+x)}O{sub 4} (x=0, 1/3 and 1) spinel-type family. In this contribution we describe the determination of the oxidation state of manganese and vanadium in Mn{sub (2−x)}V{sub (1+x)}O{sub 4} (x=0, 1/3,1) spinel-type compounds by analyzing XANES and high-resolution Kβ X-ray fluorescence spectra. The ionic models found are Mn{sup 2+}{sub 2}V{sup 4+}O{sub 4}, Mn{sup 2+}{sub 5/3}V{sup 3.5+}{sub 4/3}O{sub 4} and Mn{sup 2+}V{sup 3+}{sub 2}O{sub 4}. Combination of the present results with previous data provided a reliable cation distribution model. For these spinels, single magnetic electron paramagnetic resonance (EPR) lines are observed at 480 K showing the interaction among the different magnetic ions. The analysis of the EPR parameters show that g-values and relative intensities are highly influenced by the concentration and the high-spin state of Mn{sup 2+}. EPR broadening linewidth is explained in terms of the bottleneck effect, which is due to the presence of the fast relaxing V{sup 3+} ion instead of the weak Mn{sup 2+} (S state) coupled to the lattice. The EPR results, at high temperature, are well explained assuming the oxidation states of the magnetic ions obtained by the other spectroscopic techniques. - Graphical abstract: View of the crystallographic structure of a spinel. It shows as an example one of the models of ion distribution determined for the spinels Mn{sub (2−x)}V{sub (1+x)}O{sub 4} (x=0, 1/3,1). Display Omitted - Highlights: • Determination of oxidation state of the metallic ions in Mn{sub (2−x)}V{sub (1+x)}O{sub 4} (x=0,1/3,1) by XAS and XES techniques. • The ionic models found are Mn{sup 2+}{sub 2}V{sup 4+}O{sub 4}, Mn{sup 2+}{sub 5/3}V{sup 3.5+}{sub 4/3}O{sub 4} and Mn{sup 2+}V{sup 3+}O{sub 4}. • EPR spectra correspond almost exclusively to a resonance of Mn{sup 2+}.

36 MATERIALS SCIENCE↗

Polarity determination of ferroelectric LiNbO{sub 3} crystals and BiFeO{sub 3} thin films by the convergent beam electron diffraction technique

The applicability of various convergent beam electron diffraction (CBED) methods to the polarity determination of LiNbO{sub 3} crystals in the space group R3c was examined. We show that the method of zone-axis CBED combined with dynamical simulation is applicable to the polarity determination of LiNbO{sub 3}. The effects of the zone axis, the specimen thickness and the displacement of the homopolar atom on the polarity determination were studied. This method was also successfully applied to the polarity determination of a multiferroic BiFeO{sub 3} film deposited on a (111)Pt/TiO{sub 2}/SiO{sub 2}/Si substrate by pulsed laser deposition. It shows that about 30% of the grains in the BiFeO{sub 3} film are grown along the positive polar direction.

36 MATERIALS SCIENCE↗

A simple and inclusive method to determine the habit plane in transmission electron microscope based on accurate measurement of foil thickness

A simple and inclusive method is proposed for accurate determination of the habit plane between bicrystals in transmission electron microscope. Whilst this method can be regarded as a variant of surface trace analysis, the major innovation lies in the improved accuracy and efficiency of foil thickness measurement, which involves a simple tilt of the thin foil about a permanent tilting axis of the specimen holder, rather than cumbersome tilt about the surface trace of the habit plane. Experimental study has been done to validate this proposed method in determining the habit plane between lamellar α{sub 2} plates and γ matrix in a Ti–Al–Nb alloy. Both high accuracy (± 1°) and high precision (± 1°) have been achieved by using the new method. The source of the experimental errors as well as the applicability of this method is discussed. Some tips to minimise the experimental errors are also suggested. - Highlights: • An improved algorithm is formulated to measure the foil thickness. • Habit plane can be determined with a single tilt holder based on the new algorithm. • Better accuracy and precision within ± 1° are achievable using the proposed method. • The data for multi-facet determination can be collected simultaneously.

36 MATERIALS SCIENCE↗

Sodium doping effect on physicochemical properties of K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) for the determination of mercury(II): Application in seawater samples

Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values ​​obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.

36 MATERIALS SCIENCE↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of energy-dependent neutron backgrounds using shadow bars

Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. Here, the neutron backgrounds were determined for heavy-ion collision experiment using the shadow-bar method, where beams of 40,48 Ca at 56, 140 MeV/u impinged on targets of 58,64 Ni and 112,124 Sn. In the analysis presented here, brass shadow bars are placed in front of organic liquid scintillator neutron detectors to determine the energy-dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a ±20 °C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. In conclusion, a comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.

36 MATERIALS SCIENCE↗

Applications of tribology to determine attrition by wear of particulate solids in CFB systems

In recent years, much attention has been focused on the development of novel technologies for carbon capture and chemicals production that utilize a circulating fluidized bed (CFB) configuration; examples include chemical looping combustion and circulation of temperature swing adsorbents in a CFB configuration for CO 2 capture. A major uncertainty in determining the economic feasibility of these technologies is the required solids makeup rate, which, among other factors, is due to impact and wear attrition at various locations, including standpipes, cyclones, and the gas jets in fluid beds. While correlations have been developed that estimate the attrition rates at these areas, these correlations are dependent on constants that are uncertain without extensive experiment in the corresponding unit operation. Thus, it is difficult to determine the attrition rate a priori without performing extensive experiments on the materials or scaling up entirely. In this work, the authors outline a methodology for predictive attrition based on fundamental material properties from fields of tribology—specifically, the study of wear—to the knowledge of forces and sliding distances determined from hydrodynamic models to develop basic attrition models for novel CFB systems. The equations are derived for the standpipe and cyclone, which are common components found in CFBs, and the cyclone equation is compared to experimental data of attrition in the literature. The cyclone equation derived in this work results in an abrasion rate based on (1) material properties such as particle density and hardness, (2) inlet velocity, and (3) cyclone geometry. According to this equation, increasing the diameter of the cyclone and the solids inlet velocity tends to increase the rate of abrasion of the catalyst, while decreasing the hardness increases the abrasion rate. The functionality of the increasing attrition rate with velocity increase implies that increasing the efficiency of the cyclone may also increase the attrition rate via abrasion. With modifications to the severity coefficient term to include the solids loading, the cyclone equation derived in this work fits data from Reppenhagen and Werther with a coefficient of determination (R2) of 92%.

01 COAL, LIGNITE, AND PEAT↗