Plasma radiation dynamics with the upgraded Absolute Extreme Ultraviolet tomographical system in the Tokamak à Configuration Variable

We introduce an upgraded version of a tomographical system which is built up from Absolute Extreme Ultraviolet-type (AXUV) detectors and has been installed on the Tokamak à Configuration Variable (TCV). The system is suitable for the investigation of fast radiative processes usually observed in magnetically confined high-temperature plasmas. The upgrade consists in the detector protection by movable shutters, some modifications to correct original design errors and the improvement in the data evaluation techniques. The short-term sensitivity degradation of the detectors, which is caused by the plasma radiation itself, has been monitored and found to be severe. The results provided by the system are consistent with the measurements obtained with the usual plasma radiation diagnostics installed on TCV. Additionally, the coupling between core plasma radiation and plasma-wall interaction is revealed. This was impossible with other available diagnostics on TCV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposal of a gigawatt-class L/Ku dual-band magnetically insulated transmission line oscillator

We present a gigawatt (GW)-class magnetically insulated transmission line oscillator (MILO) which is capable of generating dual-band high power microwaves (HPMs). The proposed device, deriving from previously studied complex MILO and dual-frequency MILO, is designed to produce two HPMs in L-band and Ku-band, respectively. It is found in particle-in-cell (PIC) simulation that when the diode voltage is 610 kV, HPMs with frequencies of 1.72 GHz and 14.6 GHz can be achieved with powers of 3.3 GW and 2.4 GW, respectively. The corresponding total power conversion efficiency is approximately 12.8%. Power difference of the two generated HPMs is approximately 1.4 dB, and frequency difference of them reaches a level as high as ∼10 dB.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experience On Plasma Diagnostics On JET

This year marks the 30th anniversary of the decision on 17 October 1977 by the European Council of Ministers to proceed with the JET project. Very little thought had been given to the diagnostic requirements during the design phase--indeed many people assumed that JET would not do detailed physics studies and would need only a few basic diagnostics. Of course this view turned out to be incorrect--JET needed a comprehensive set of diagnostics and has conducted a very extensive physics programme. The large physical dimensions of JET, the radiation environment and the stringent interface standards radically changed our concept of diagnostics compared to the smaller fusion experiments that had gone before. In this paper I will review some of the experience on burning plasma diagnostics on JET.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave to plasma coupling in electron cyclotron resonance and microwave ion sources (invited)

Coupling improvements between microwaves and plasmas are a key factor to design more powerful electron cyclotron resonance and microwave ion sources. On this purpose different activities have been undertaken by the INFN-LNS ion source team and a new approach was developed. Recent experiments confirmed the simulations, demonstrating that even in presence of a dense plasma, resonant modes are excited inside the cavity and the plasma dynamics depends on their structure. An overview of the coupling issues on microwave ion sources is also given along with a discussion on alternative coupling techniques.

43 PARTICLE ACCELERATORS↗

Design of pulsed guiding magnetic field for high power microwave generators

In this paper, we present a comprehensive study on designing solenoid together with the corresponding power supply system to excite pulsed magnetic field required for high power microwave generators. Particularly, a solenoid is designed and the excited magnetic field is applied to a Ku-band overmoded Cerenkov generator. It is found in experiment that the electron beam is properly guided by the magnetic field and a 1.1 GW high power microwave is achieved at a central frequency of 13.76 GHz. Pulsed solenoid system has the advantages of compactness and low energy consumption, which are of great interest for repetitive operation. The reported studies and results can be generalized to other applications which require magnetic fields.

43 PARTICLE ACCELERATORS↗

Status of research toward the ITER disruption mitigation system

An overview of the present status of research toward the final design of the ITER disruption mitigation system (DMS) is given. The ITER DMS is based on massive injection of impurities, in order to radiate the plasma stored energy and mitigate the potentially damaging effects of disruptions. The design of this system will be extremely challenging due to many physics and engineering constraints such as limitations on port access and the amount and species of injected impurities. Additionally, many physics questions relevant to the design of the ITER disruption mitigation system remain unsolved such as the mechanisms for mixing and assimilation of injected impurities during the rapid shutdown and the mechanisms for the subsequent formation and dissipation of runaway electron current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Diagnostic For Electrical Breakdowns In Vacuum

The design of an inexpensive, small, high bandwidth diagnostic for the study of vacuum insulator flashover is described. The diagnostic is based on the principle of capacitive coupling and is commonly referred to as a D-dot probe due to its sensitivity to the changing of the electric displacement field. The principle challenge for the design proved to be meeting the required mechanical size for the application rather than bandwidth. An array of these probes was fabricated and used in an insulator test stand. Data from the test stand with detailed analysis is presented. A highlight of the application of the probes to the test stand was the ability to detect the charging of the insulator surface by UV illumination as a prelude to the insulator flashover. The abrupt change in the insulator's surface charge during the flashover was also detected.

42 ENGINEERING↗

Sustainable recovery of critical metals from spent lithium-ion batteries through gluconic acid-based bioleaching: Techno-economic analysis, life cycle assessment and process optimization

Recycling spent lithium-ion batteries (LIB) could potentially bridge the ever increasing supply and demand gap for critical metals and simultaneously facilitate the management of hazardous battery waste. This study investigated the optimization of gluconic acid-based bioleaching technology through design of experiments (DOE), combined with techno-economic analysis (TEA), and life cycle assessment (LCA) with the aim of maximizing the net present value (NPV) and minimizing global warming impacts of the process. Biolixiviant containing predominantly gluconic acid produced by the genetically engineered (ΔpstS, P 112 :mgdh) Gluconobacter oxydans B58 through fermentation using non-recyclable paper as a growth substrate was used for the LIB leaching. At optimal bioleaching conditions of gluconic acid (160 mM), leaching time (2.5 h), reducing agent FeSO 4 to metal, i.e., cobalt (Co), nickel (Ni) and manganese (Mn), mole ratio (0.88), temperature (55 °C) and pulp density (2.5 %), the leaching efficiency was 87 % 72 %, 94 %, and 88 % for Co, Ni, Mn and lithium (Li), respectively. TEA analysis confirmed that bioleaching plant with an annual black mass processing capacity of 10,000 metric tons and plant life of 30 years would be economically viable with an NPV and profit margin of $136 million and 11 %, respectively. The predicted carbon footprint of gluconic acid-based bioleaching for recovering 1 kg of Co (13.2 kg of CO 2 eq.) is lower compared to that of most state-of-the-art leaching technologies. Moreover, gluconic acid-based bioleaching effectively recovered target metals when tested for different black mass chemistries.

Bioleaching↗

Plant Models for DEMO

The European Power Plant Conceptual Study (PPCS) has been a study of conceptual designs for commercial fusion power plants. It focused on five power plant models, named PPCS A, B, AB, C and D, which are illustrative of a wider spectrum of possibilities. The PPCS study highlighted the need for specific design and R and D activities as well as the need to clarify the concept of DEMO, the device that will bridge the gap between ITER and the first fusion power plant. An assessment of the PPCS models with limited extrapolations has led to the clarification of the objectives of DEMO. Many parameters will have to be controlled in DEMO in order (1) to control the machine, (2) to satisfy the testing requirements, (3) to satisfy regulatory requirements (primarily safety), and (4) to protect the investment. On the other, DEMO will ulilise one or two plasma scenarios only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is discussed, along with the measured performance results, calibration methodology and verification, and minimum detectable activity levels. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Northstar Technology Transfer and Facility Development Work Package FY19 Summary Report

Northstar is rapidly advancing toward a Mo99 production facility. This will be a demonstration and technology development or proof-of-concept facility comprised of 1 target station. The target will be 2 sided, irradiated by 2 rhodotrons. Diagrams of the facility are included in this report. LANL has provided support in FY19 on many components and systems toward the realization of this facility. Besides providing the documentation and lessons learned from years of concept development and tests of targets and other subsystems, specific development work was provided in a number of areas, including bulk and local shielding, target insertion and removal, facility layout, and target holder development. These will be discussed in some detail.

43 PARTICLE ACCELERATORS↗

A simple external resistance heating diamond anvil cell and its application for synchrotron radiation x-ray diffraction

A simple external heating assemblage allowing diamond anvil cell experiments at pressures up to 34 GPa and temperatures up to 653 K was constructed. This cell can be connected to the synchrotron radiation conveniently. The design and construction of this cell are fully described, as well as its applications for x-ray diffraction. Heating is carried out by using an external-heating system, which is made of NiCr resistance wire, and the temperature was measured by a NiCr-NiSi or PtRh-Pt thermocouple. We showed the performance of the new system by introducing the phase transition study of cinnabar ({alpha}-HgS) and thermal equation of state study of almandine at high pressure and temperature with this cell.

36 MATERIALS SCIENCE↗

Novel CO{sub 2} capture. Final CRADA Report.

The goal of this work was to use electrochemically driven pH control to develop a second generation, enzyme-based contained liquid membrane (CLM) permeator to extract CO{sub 2} from a variety of coal-based flue gas streams more efficiently than does the CLM current design, while achieving performance coincident with DOE targets of less than 45% Cost of electricity (COE) in 2007 and less than 20% COE in 2012. Central to this goal the CLM would be alkaline (>pH 8) at the feed gas side and acid (<pH 6) at the permeate side. Argonne demonstrated the technical feasibility for CO{sub 2} capture and release using Argonne's resin-wafer electrode ionization (RW-EDI) system integrated with Carbozyme's carbonic anhydrase (CA) enzyme. Argonne developed RW-EDI for pH controlled desalination of process streams (e.g. Patents 7,452,920 & 7,306,934). In the current work, Argonne captured CO{sub 2} as HCO{sub 3}{sup -} and released it as CO{sub 2}. The goal is to both capture CO{sub 2} from a simulated flue gas stream and release it within the DOE targets for increase in COE. Initial performance results indicate that the 2012 COE targets are achievable with the developed technology. The design is subject to patent-hold. This task was funded in an exploratory phase, so no process optimization was attempted. Argonne believes that with optimization this performance could be significantly improved.

54 ENVIRONMENTAL SCIENCES↗

Analysis methodology of movable emittance-meter measurements for low energy electron beams

The design of photoinjectors for modern free electron laser linac relies heavily on particular beam behavior in the few meters after the gun. To experimentally characterize it a movable emittance meter was proposed and built [L. Catani et al., Rev. Sci. Instrum. 77, 093301 (2006)] based on the beam slicing technique. This paper addresses all the aspects of analysis of the data acquired with the emittance meter and common to any slit based emittance measurement for low energy beams.

43 PARTICLE ACCELERATORS↗

Design of polarizers for a mega-watt long-pulse millimeter-wave transmission line on the large helical device

The polarizer is one of the critical components in a high-power millimeter-wave transmission line. It requires full and highly efficient coverage of any polarization states, high-power tolerance, and low-loss feature. Polarizers with rounded shape at the edge of the periodic groove surface are designed and fabricated by the machining process for a mega-watt long-pulse millimeter-wave transmission line of the electron cyclotron resonance heating system in the large helical device. The groove shape of λ/8- and λ/4-type polarizers for an 82.7 GHz transmission line is optimally designed in an integral method developed in the vector theories of diffraction gratings so that the efficiency to realize any polarization state can be maximized. The dependence of the polarization states on the combination of the two polarizer rotation angles (Φ{sub λ/8}, Φ{sub λ/4}) is examined experimentally in a low-power test with the newly developed polarization monitor. The results show that the measured polarization characteristics are in good agreement with the calculated ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing ARIES-CS compact radial build and nuclear system: Neutronics, shielding, and activation

Within the ARIES-CS project, design activities have focused on developing the first compact device that enhances the attractiveness of the stellarator as a power plant. The objectives of this paper are to review the nuclear elements that received considerable attention during the design process and provide a perspective on their successful integration into the final design. Among these elements are the radial build definition, the well-optimized in-vessel components that satisfy the ARIES top-level requirements, the carefully selected nuclear and engineering parameters to produce an economic optimum, the modeling for the first time ever-of the highly complex stellarator geometry for the three-dimensional nuclear assessment, and the overarching safety and environmental constraints to deliver an attractive, reliable, and truly compact stellarator power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗