Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analytical Framework for Homeowner-Focused Computational Cost-Benefit Mitigation Decision Making

As a result of increasing windstorm losses in the United States over the past 50 years, a variety of residential wind hazard mitigation strategies have been recommended. Wind hazard mitigation undoubtedly reduces windstorm losses; however, little customized information is available to support the economic decision-making process for individual stakeholders, especially at the consumer level. Therefore, there is a need for decision support tools to calculate, evaluate, and present the economic benefits of mitigation over variable decision-making time horizons for unique building characteristics in specific geographical locations. This paper presents a cost-benefit computational decision-making recommendation framework that evaluates and presents the cost effectiveness of mitigation, customized based on location, years of interest, and building characteristics. The decision-making framework consists of two cores. The user-independent core and user-dependent core which consists of eight steps, divided into four subprocesses: (1) data acquisition, (2) data evaluation, (3) cost-benefit calculation, and (4) results comparison and decision making. To demonstrate the framework, a wood-framed single-family home in light suburban terrain in Golden Meadow, Louisiana, is used as a case study, considering retrofit mitigation with a $15,000 budget and a decision-making time horizon of 30 years. The case study provides six mitigation options, with cost ranging between approximately $2,000 and $15,000 and net benefit/cost ratios ranging from 2.4 to 13. Once fully implemented in a decision making information tool, the developed mitigation recommendation framework will provide valuable information that can be used by home designers, builders, owners, and other stakeholders to better understand the economic facets of wind hazard mitigation, providing critical information as part of the overall decision-making process.

Orooji, Fatemeh↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Biosurveillance Data Stream Framework: A Novel Approach to Characterization and Evaluation

Multiple data sources are used in a variety of biosurveillance systems. With the advent of new technologies, globalization, high performance computing, and "big data" opportunities, there are seemingly unlimited potential data streams that could be useful in biosurveillance. Data streams have not been universally defined in either the literature or by specific biosurveillance systems. Furthermore, the definitions and framework that we have developed enable a characterization methodology that facilitates understanding of data streams and can be universally applicable for use in evaluating and understanding a wide range of biosurveillance activities- filling a gap recognized in both the public health and biosurveillance communities.

59 BASIC BIOLOGICAL SCIENCES↗

The Scale Method as an Approach for Prompt Fission Neutron Spectra Analysis and Evaluation

The Scale Method was applied for an analysis of experimental and evaluated data of Prompt Fission Neutron Spectra for different isotopes and incident neutron energies below 6 MeV. It was demonstrated that the method describes all experimental data sets in the outgoing neutron energy range 0–7 MeV within uncertainties. Theoretical arguments were provided to support the application of this method. Some important peculiarities connected with the neutron emission mechanism were identified, and proposals for future theoretical and experimental investigations were discussed. It was concluded that the new evaluations completed recently for {sup 235}U systematically overestimate the average energy of experimental prompt fission neutron spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressure Oscillations in Shuttle Solid Rocket Motors

All Shuttle Solid Rocket Motors (SRM's) exhibit low amplitude longitudinal pressure oscillations during motor burn. Although the oscillations have no known deleterious effect on motor ballistics, the acoustic pressure variations cause thrust oscillations that might affect Shuttle systems or components. The acoustic mode of greatest interest is the first or fundamental mode which, in the SRM, has a nominal frequency of 14-Hz. Oscillations in the SRM are believed to be caused by coupling between large scale vortices and the acoustic modes of the motor chamber. The vortices are thought to be created in the region of the motor segment interfaces and are inherent in the design of the motor. In such a situation the usual approach is to measure the oscillations and assess their impact on any sensitive components through tests and analysis. Questionable components can be altered to survive the vibration environment. As motor firings occur, oscillations are monitored to determine whether there are changes in the nature of the oscillations. Since the first static test, SRM's have been equipped with instrumentation especially designed to acquire chamber pressure oscillation data. Data from the first SRM static tests were used to establish predicted upper bounds for the maximum amplitudes in the latter half of burn. Those bounds have been used as a basis for worst-case simulation scenarios by specialists in structural dynamics at NASA and Rockwell International and to provide a basis for evaluating data from individual motors which were tested subsequent to the original SRM's. This paper updates the upper bounds prediction the High Performance Motors (HPM) by including data from all static tests performed to date including both original SRM's and post Challenger SRM's or Reusable Solid Rocket Motors (RSRM) in which the joint design was changed. All together, this study examines 27 SRM motors, 16 HPM motors and 11 RSRM motors. Predicted upper bounds will be made for both the first and second longitudinal modes. The first mode upper bounds will be compared to the original seven standard rocket motors (STD). The results indicate that, although the upper bounds have increased, they are still within acceptable bounds.

Blomshield, Fred S.↗

Phenomenological R -Matrix parameterization of direct, doorway, and compound nuclear reactions [Abstract]

Although formal expressions for scattering matrix accounting for direct, doorway, and compound nuclear (CN) resonant reactions have been derived several decades ago in both the transition ( T -)matrix formalism and the reactance ( K -)matrix formalism, the absence of corresponding expressions in phenomenological R -matrix formalism has limited the application of the latter to CN resonant reactions only. We remove this limitation by parameterizing direct, doorway, and CN resonant reactions in a phenomenological R -matrix scattering matrix, and provide a parameterization for a corresponding Reich-Moore approximation of eliminated capture channels. Direct reactions induce (previously neglected) mixing among the incoming or outgoing R -matrix channel wave functions, parameterized by real and orthonormal channel-rotation matrix, M , whereby the original scattering matrix U is transformed into M T UM . Any real and orthonormal matrix, M , can be equivalently expressed as e η , where η is a real and skew-symmetric 2 rotation-generating matrix that subsequently yields a more intuitive parameterization of eliminated direct capture reactions in Reich-Moore approximation. A phenomenological R -matrix parameterization of doorway reactions is inferred by equating the expression for reactance ( K -)matrix, given in terms of Brune’s alternative R -matrix parameterization, to a corresponding expression derived using Feshbach’s projection operator formalism. Assuming that all doorway states, just like CN states, are confined within spheres defined by R -matrix channel radii, a new R -matrix-like term induced by doorway states is gleaned, wherein each doorway state is parameterized by its energy, width, and the strength of its coupling to each CN state. Since a Reich-Moore approximation for retained-channel scattering matrix ought to approximate the effect of eliminated capture channels taking place via direct, doorway, or CN reactions, each of the three kinds of reactions contributing to the capture entails a corresponding Reich-Moore parameterization in a first-order approximation: direct contribution is parameterized by introducing finite diagonal elements of a retained-channel rotation-generating matrix, doorway contribution is parameterized by doorway capture widths, while CN contribution is parameterized by conventional Reich-Moore capture widths. We will present evidence of direct and doorway reactions observed in recent measurements of resolved resonance cross sections at the Gaerttner LINAC Center at Rensselaer Polytechnic Institute, and will outline a path for implementing this new R -matrix parameterization into the SAMMY nuclear data evaluation code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Omics Research on the International Space Station

The International Space Station (ISS) is an orbiting laboratory whose goals include advancing science and technology research. Completion of ISS assembly ushered a new era focused on utilization, encompassing multiple disciplines such as Biology and Biotechnology, Physical Sciences, Technology Development and Demonstration, Human Research, Earth and Space Sciences, and Educational Activities. The research complement planned for upcoming ISS Expeditions 45&46 includes several investigations in the new field of omics, which aims to collectively characterize sets of biomolecules (e.g., genomic, epigenomic, transcriptomic, proteomic, and metabolomic products) that translate into organismic structure and function. For example, Multi‐Omics is a JAXA investigation that analyzes human microbial metabolic cross‐talk in the space ecosystem by evaluating data from immune dysregulation biomarkers, metabolic profiles, and microbiota composition. The NASA OsteoOmics investigation studies gravitational regulation of osteoblast genomics and metabolism. Tissue Regeneration uses pan‐omics approaches with cells cultured in bioreactors to characterize factors involved in mammalian bone tissue regeneration in microgravity. Rodent Research‐3 includes an experiment that implements pan‐omics to evaluate therapeutically significant molecular circuits, markers, and biomaterials associated with microgravity wound healing and tissue regeneration in bone defective rodents. The JAXA Mouse Epigenetics investigation examines molecular alterations in organ specific gene expression patterns and epigenetic modifications, and analyzes murine germ cell development during long term spaceflight. Lastly, Twins Study ("Differential effects of homozygous twin astronauts associated with differences in exposure to spaceflight factors"), NASA's first foray into human omics research, applies integrated analyses to assess biomolecular responses to physical, physiological, and environmental stressors associated with spaceflight.

Love, John↗

Use of genomic data in risk assessment case study: II. Evaluation of the dibutyl phthalate toxicogenomic data set

An evaluation of the toxicogenomic data set for dibutyl phthalate (DBP) and male reproductive developmental effects was performed as part of a larger case study to test an approach for incorporating genomic data in risk assessment. The DBP toxicogenomic data set is composed of nine in vivo studies from the published literature that exposed rats to DBP during gestation and evaluated gene expression changes in testes or Wolffian ducts of male fetuses. The exercise focused on qualitative evaluation, based on a lack of available dose–response data, of the DBP toxicogenomic data set to postulate modes and mechanisms of action for the male reproductive developmental outcomes, which occur in the lower dose range. A weight-of-evidence evaluation was performed on the eight DBP toxicogenomic studies of the rat testis at the gene and pathway levels. The results showed relatively strong evidence of DBP-induced downregulation of genes in the steroidogenesis pathway and lipid/sterol/cholesterol transport pathway as well as effects on immediate early gene/growth/differentiation, transcription, peroxisome proliferator-activated receptor signaling and apoptosis pathways in the testis. Since two established modes of action (MOAs), reduced fetal testicular testosterone production and Insl3 gene expression, explain some but not all of the testis effects observed in rats after in utero DBP exposure, other MOAs are likely to be operative. A reanalysis of one DBP microarray study identified additional pathways within cell signaling, metabolism, hormone, disease, and cell adhesion biological processes. These putative new pathways may be associated with DBP effects on the testes that are currently unexplained. This case study on DBP identified data gaps and research needs for the use of toxicogenomic data in risk assessment. Furthermore, this study demonstrated an approach for evaluating toxicogenomic data in human health risk assessment that could be applied to future chemicals. - Highlights: ► We evaluate the dibutyl phthalate toxicogenomic data for use in risk assessment. ► We focus on information about the mechanism of action for the developing testis. ► Multiple studies report effects on testosterone and insl3-related pathways. ► We identify additional affected pathways that may explain some testis effects. ► The case study is a template for evaluating toxicogenomic data in risk assessment.

60 APPLIED LIFE SCIENCES↗

Space Shuttle Main Engine Low Pressure Oxidizer Turbo-Pump Inducer Dynamic Environment Characterization through Water Model and Hot-Fire Testing

The Low Pressure Oxidizer Turbopump (LPOTP) inducer on the Block II configuration Space Shuttle Main Engine (SSME) experienced blade leading edge ripples during hot firing. This undesirable condition led to a minor redesign of the inducer blades. This resulted in the need to evaluate the performance and the dynamic environment of the redesign, relative to the current configuration, as part of the design acceptance process. Sub-scale water model tests of the two inducer configurations were performed, with emphasis on the dynamic environment due to cavitation induced vibrations. Water model tests were performed over a wide range of inlet flow coefficient and pressure conditions, representative of the scaled operating envelope of the Block II SSME, both in flight and in ground hot-fire tests, including all power levels. The water test hardware, facility set-up, type and placement of instrumentation, the scope of the test program, specific test objectives, data evaluation process and water test results that characterize and compare the two SSME LPOTP inducers are discussed. In addition, dynamic characteristics of the two water models were compared to hot fire data from specially instrumented ground tests. In general, good agreement between the water model and hot fire data was found, which confirms the value of water model testing for dynamic characterization of rocket engine turbomachinery.

Patrick Arellano↗

ORNL Neutron Cross Section Measurements of 90 Zr NCSP ND-1 Task [Slides]

Luiz Leal's idea to integrate the experimental uncertainties, covariances, and sensitivities in this workflow and centralize the process at one location led to the creation of a cohesive tool for data testing. It has been practiced for more than two decades by the NCS and ND groups at ORNL. The development and use of the ORNL codes TSUNAMI and TSURFER within SCALE made it possible. Today, it has been extended to SAMINT which enables the coupling of differential and integral data evaluation in a continuous-energy framework.

43 PARTICLE ACCELERATORS↗

IER 516: Zirconium Test Assembly CED Phase-1: Preliminary Experiment Design

IER-516, Zirconium Test Assembly (ZTA), is a campaign to design, execute, and document a series of high-fidelity critical benchmark experiments to validate current and future zirconium (Zr) and zirconium hydride (ZrH x ) nuclear data evaluations. ZTA is a collaborative project between Los Alamos National Laboratory and the French Autoritè de Sûretè Nuclèaire et de Radioprotection. The experiments will be fueled with highly enriched uranium (HEU), and utilize the Comet critical assembly machine at the National Criticality Experiments Research Center. A total of ten preliminary critical experiments were designed and optimized for Zr and ZrHx nuclear data sensitivities using the MCNP-Particle Swarm Optimization methodology in the thermal, epithermal, intermediate, and fast neutron energy regions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning prediction of electron density and temperature from He I line ratios

We propose to utilize machine learning to predict the electron density, ne, and temperature, T e , from He I line intensity ratios. In this approach, training data consist of measured He I line ratios as input and ne and T e measured using other diagnostic(s) as desired output, which is a Langmuir probe in our study. Support vector machine regression analysis is, then, performed with the training data to develop a predictive model for n e and T e , separately. It is confirmed that n e and T e predicted using the developed models agree well with those from the Langmuir probe in the ranges of 0.28 × 10 18 ≤ n e (m -3 ) ≤ 3.8 × 10 18 and 3.2 ≤ T e (eV) ≤ 7.5. The developed models are, further, examined with an evaluation data, which are not included in the training data, and are found to well reproduce absolute values and radial profiles of probe-measured n e and T e .

47 OTHER INSTRUMENTATION↗

The evolution of procurement and assurance methods used to proof an advanced space material

A development history and current performance evaluation is presented for a Kapton polyimide for the Space Station Freedom. Analyses of results obtained for this class of materials by the Long Duration Exposure Facility led to major revisions of procurement specifications and test requirements for this material. Attention is given to the use of oxygen plasma etching and blocking, as well as the evolution of test methodologies due to preproduction test data evaluations and the relationship between tests and product-improvement cycles.

Berendt, Marjorie↗

ORNL neutron cross section measurements and evaluations for improved nuclear data [Slides]

This presentation discusses the nuclear data measurements and evaluation work for NCSP, including its objective which is to provide measured and evaluated thermal, resonance, unresolved resonance, and fast region cross-section data to address the priority NCSP nuclear data needs. It also discusses its vision which addresses multiple Nuclear Data 5- and 10-year goals and attributes identified in the NCSP Vision. The intended final product is that rigorous ENDF/B evaluations will be produced from cross section measurements and analyses. Measurement work effort focused on NCSP priorities by NCSP Nuclear Data Advisory Group (NDAG) can be found in Appendix B of the 5-year plan. NCSP measurements program at JRC is now part of the DOE/Euratom agreement, Action Sheet 66.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL Neutron Cross Section Measurements of 90 Zr NCSP ND-1 Task [Slides]

Luiz Leal's idea to integrate the experimental uncertainties, covariances, and sensitivities in the ND workflow and to centralize the process at one location created a cohesive tool for data testing. It has been practiced for more than two decades by the NCS and ND groups at ORNL. The development and use of the ORNL codes TSUNAMI and TSURFER within SCALE made it possible. Today, it has been extended to SAMINT, which enables the coupling of differential and integral data evaluation in a continuous-energy framework.

43 PARTICLE ACCELERATORS↗