At least 577 records · Page 32

WREF 2012: THE PAST AND FUTURE COST OF WIND ENERGY

The future of wind power will depend on the ability of the industry to continue to achieve cost reductions. To better understand the potential for cost reductions, this report provides a review of historical costs, evaluates near-term market trends, and summarizes the range of projected costs. It also notes potential sources of future cost reductions. Our findings indicate that steady cost reductions were interrupted between 2004 and 2010, but falling turbine prices and improved turbine performance are expected to drive a historically low LCOE for current installations. In addition, the majority of studies indicate continued cost reductions on the order of 20%-30% through 2030. Moreover, useful cost projections are likely to benefit from stronger consideration of the interactions between capital cost and performance as well as trends in the quality of the wind resource where projects are located, transmission, grid integration, and other cost variables.

17 WIND ENERGY↗

Evaluating the Cost Benefits of U.S. Utility-Scale Photovoltaics Plus Energy Storage Systems

Utility-scale photovoltaics (PV) system market growth has been rapid for several years. Today, with the cost reductions of energy storage technologies, the application of combing PV and energy storage has become feasible and beneficial, especially for the areas that only have PV standalone systems and need to shift the peak load to meet the evening electricity demand. Overall, the utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a systemlevel bottom-up cost modeling approach. We use this model to benchmark PV plus storage installation system cost and identify cost difference for AC and DC coupled systems and duration variation. Finally, we assess the cost reduction opportunities of co-locating PV system with energy storage system in order to indicate the possible economic impacts of PV plus storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Survey of State-Level Cost and Benefit Estimates of Renewable Portfolio Standards

Most renewable portfolio standards (RPS) have five or more years of implementation experience, enabling an assessment of their costs and benefits. Understanding RPS costs and benefits is essential for policymakers evaluating existing RPS policies, assessing the need for modifications, and considering new policies. This study provides an overview of methods used to estimate RPS compliance costs and benefits, based on available data and estimates issued by utilities and regulators. Over the 2010-2012 period, average incremental RPS compliance costs in the United States were equivalent to 0.8% of retail electricity rates, although substantial variation exists around this average, both from year-to-year and across states. The methods used by utilities and regulators to estimate incremental compliance costs vary considerably from state to state and a number of states are currently engaged in processes to refine and standardize their approaches to RPS cost calculation. The report finds that state assessments of RPS benefits have most commonly attempted to quantitatively assess avoided emissions and human health benefits, economic development impacts, and wholesale electricity price savings. Compared to the summary of RPS costs, the summary of RPS benefits is more limited, as relatively few states have undertaken detailed benefits estimates, and then only for a few types of potential policy impacts. In some cases, the same impacts may be captured in the assessment of incremental costs. For these reasons, and because methodologies and level of rigor vary widely, direct comparisons between the estimates of benefits and costs are challenging.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Report - Stationary and Emerging Market Fuel Cell System Cost Assessment

The U.S. Department of Energy (DOE) is focused on providing a portfolio of technology solutions to meet energy security challenges of the future. Fuel cells are a part of this portfolio of technology offerings. To help meet these challenges and supplement the understanding of the current research, Battelle has executed a five-year program that evaluated the total system costs and total ownership costs of two technologies: (1) an ~80 °C polymer electrolyte membrane fuel cell (PEMFC) technology and (2) a solid oxide fuel cell (SOFC) technology, operating with hydrogen or reformate for different applications. Previous research conducted by Battelle, and more recently by other research institutes, suggests that fuel cells can offer customers significant fuel and emission savings along with other benefits compared to incumbent alternatives. For this project, Battelle has applied a proven cost assessment approach to assist the DOE Fuel Cell Technologies Program in making decisions regarding research and development, scale-up, and deployment of fuel cell technology. The cost studies and subsequent reports provide accurate projections of current system costs and the cost impact of state-of-the-art technologies in manufacturing, increases in production volume, and changes to system design on system cost and life cycle cost for several near-term and emerging fuel cell markets. The studies also provide information on types of manufacturing processes that must be developed to commercialize fuel cells and also provide insights into the optimization needed for use of off-the-shelf components in fuel cell systems. Battelle’s analysis is intended to help DOE prioritize investments in research and development of components to reduce the costs of fuel cell systems while considering systems optimization.

08 HYDROGEN↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Wind Soft Costs: A Beginning

Tony Jimenez presented this overview of distributed wind soft costs at the 2016 Small Wind Conference in Stevens Point, Wisconsin, on June 14, 2016. Soft costs are any non-hardware project costs, such as costs related to permitting fees, installer/developer profit, taxes, transaction costs, permitting, installation, indirect corporate costs, installation labor, and supply chain costs. This presentation provides an overview of soft costs, a distributed wind project taxonomy (of which soft costs are a subset), an alpha data set project demographics, data summary, and future work in this area.

17 WIND ENERGY↗

Chemical looping combustion oxygen carrier production cost study

The objective of this study was to estimate the cost of commercial production of oxygen carriers (OCs) for large-scale application in a mature, chemical looping combustion (CLC) power generation industry. Estimates of cost were made for two production facility scenarios: 1) build and operate an on-site, OC production facility located at a 550 MW CLC power plant site; and 2) build and operate a central production facility to produce and distribute OCs to the U.S. CLC power generation industry. Two OC production techniques were addressed: mechanical mixing and co-precipitation. Representative OCs that have production raw materials with sufficient commercial availability to support a CLC industry are ilmenite, a natural OC, and four engineered OC types, Fe 2 O 3 -based, CuO-based, NiO-based, and CuFeAlO 4 -based, with candidate OC support materials Al 2 O 3 and TiO 2 . The costs of the OC production raw materials represent the major portion of the OC product cost; the OC production cost, in dollars per kg, has been found to be nearly a linear function of the OC raw materials cost, in dollars per kg. In conclusion, the estimated OC product costs can be used to estimate the maximum OC loss rate yielding a designated CLC power plant cost-of-electricity (COE) target as a development guide, and it has been found that the maximum OC makeup rate, in kg per hour, achieving a designated COE reduction goal relative to a conventional pulverized coal (PC) power plant, will be nearly inversely proportional to the OC production raw materials cost, in dollars per kg.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon dioxide pipeline network transportation cost model: evaluating economic and geographic factors for efficient carbon capture, storage, and utilization

This study presents a comprehensive pipeline network modeling framework to estimate the CO 2 delivery cost for CO 2 utilization and geologic CO 2 storage across the United States. We developed a Python-based CO 2 pipeline transportation cost model leveraging Argonne National Laboratory’s pipeline engineering expertise and detailed natural gas transmission pipeline cost data across U.S. regions. Using existing road corridors as practical routing guides, the model designs pipeline networks that aggregate CO 2 from one or multiple sources and deliver it to selected destinations. It then minimizes the total transportation cost by optimizing pipeline diameters and incorporating booster pumps. A key contribution is the incorporation of up-to-date, region-specific cost factors with itemized components for materials, labor, miscellaneous construction expenses, and right-of-way acquisition. Results emphasize that regional variation and economies of scale associated with CO 2 pipeline costs are significant and should be explicitly accounted for in screening and planning studies. By combining realistic routing constraints with regionalized cost inputs, the model provides transparent design methodology and location-specific insights into source–destination delivery costs, including the effects of routing complexity along existing road networks. We demonstrate the model with two illustrative case studies – one for CO 2 storage and one for CO 2 utilization – in which the model designs pipeline networks spanning hundreds of miles across the states, collecting CO 2 from multiple sources and delivering it to designated endpoints while minimizing levelized cost of delivery via diameter and compression optimization. The model offers a practical, scalable approach for alternative design option screening and early-stage CO 2 transportation planning.

CCS↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for determining optimal electric range by considering electric vehicle lightweighting on perceived ownership cost

The limited driving range due to high costs and low energy densities of batteries constraints the battery electric vehicle (BEV) market growth. Lightweighting in theory can reduce energy consumption rate and extend the driving range. The knowledge gap is to quantitatively link the cost-effectiveness of light-weight technologies with range extension and consumer acceptance of BEVs. In this study, a physics-based energy consumption model of BEVs is constructed and associated with a statistics-based model on the basis of travel surveys. A perceived cost of ownership (PCO) is then developed by adding intangible costs to traditional total cost of ownership models. We estimate, at the disaggregate vehicle model and driver level and the aggregate market level, 1) the extended range due to lightweighting for a given battery size; and 2) the optimal electric range based on lightweighting decisions. The cost-effectiveness of lightweighting for BEV range extension is found to vary with income-dependent daily range limitation value, driving patterns and lightweighting technology costs. In general, adopting lightweighting in BEVs is more cost-effective for consumers with higher daily limitation value, as well as for those with higher driving intensity or suitable daily driving patterns. When the lightweighting involves a higher vehicle production cost, less lightweighting could reduce the overall PCO for BEV owners. 4 of the selected top ten BEV models are found to benefit from additional 2.09%–4.45% lightweighting. Finally, the method built in this study can guide automakers in planning R&D investments in battery and lightweighting technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Scaling trends for balance-of-system costs at land-based wind power plants: Opportunities for innovations in foundation and erection

Wind power plant sizes, hub heights, and turbine ratings have increased since 2008 to optimize the cost and performance of wind power; however, the limits of these economies of scale remain unclear. Here, we explore how the costs incurred to install turbines at a wind power plant—the balance-of-system (BOS) costs—scale with turbine rating, hub height, and plant size. We also investigate how these changes in BOS costs influence the levelized cost of energy (LCOE). We show that increasing the plant size from 150 to 400 MW could reduce the BOS costs by 21%. We also show that if the foundation costs decreased by 50%, building a wind power plant with 5-MW turbines (having rotor diameters of 166 m and hub heights of 120 m) could decrease the LCOE by 5%. These results could help inform future BOS cost-reduction opportunities and thereby reduce future capital costs for land-based wind power.

17 WIND ENERGY↗

Cost effectiveness of preemptive school closures to mitigate pandemic influenza outbreaks of differing severity in the United States

Background: Nonpharmaceutical interventions (NPIs) may be considered as part of national pandemic preparedness as a first line defense against influenza pandemics. Preemptive school closures (PSCs) are an NPI reserved for severe pandemics and are highly effective in slowing influenza spread but have unintended consequences. Methods: We used results of simulated PSC impacts for a 1957-like pandemic (i.e., an influenza pandemic with a high case fatality rate) to estimate population health impacts and quantify PSC costs at the national level using three geographical scales, four closure durations, and three dismissal decision criteria (i.e., the number of cases detected to trigger closures). At the Chicago regional level, we also used results from simulated 1957-like, 1968-like, and 2009-like pandemics. Our net estimated economic impacts resulted from educational productivity costs plus loss of income associated with providing childcare during closures after netting out productivity gains from averted influenza illness based on the number of cases and deaths for each mitigation strategy. Results: For the 1957-like, national-level model, estimated net PSC costs and averted cases ranged from $\$7.5$ billion (2016 USD) averting 14.5 million cases for two-week, community-level closures to $\$97$ billion averting 47 million cases for 12-week, county-level closures. We found that 2-week school-by-school PSCs had the lowest cost per discounted life-year gained compared to county-wide or school district–wide closures for both the national and Chicago regional-level analyses of all pandemics. The feasibility of spatiotemporally precise triggering is questionable for most locales. Theoretically, this would be an attractive early option to allow more time to assess transmissibility and severity of a novel influenza virus. However, we also found that county-wide PSCs of longer durations (8 to 12 weeks) could avert the most cases (31–47 million) and deaths (105,000–156,000); however, the net cost would be considerably greater ($\$88$-$\$103$ billion net of averted illness costs) for the national-level, 1957-like analysis. Conclusions: We found that the net costs per death averted ($\$180,000$-$\$4.2$ million) for the national-level, 1957-like scenarios were generally less than the range of values recommended for regulatory impact analyses ($\$4.6$ to 15.0 million). This suggests that the economic benefits of national-level PSC strategies could exceed the costs of these interventions during future pandemics with highly transmissible strains with high case fatality rates. In contrast, the PSC outcomes for regional models of the 1968-like and 2009-like pandemics were less likely to be cost effective; more targeted and shorter duration closures would be recommended for these pandemics.

60 APPLIED LIFE SCIENCES↗

Parametric and Nonparametric Models of U.S. Cost Overruns for Nuclear Power Plants

This study presents new data-driven models to estimate the effect of capacity on the percentage of cost overruns in the United States for nuclear power plant construction projects before and after the Three Mile Island accident. Parametric and nonparametric models have been developed that describe the significant shifts in nuclear energy costs during the dynamic environment. Employing a contemporary descriptive methodology and a quantitative analysis, we furnish a comprehensive overview of the alterations in cost overrun distribution and show the changes observed in other pivotal metrics alongside cost overruns. Our emphasis lies in documenting the fluctuations in cost overruns alongside nuclear reactor capacity levels and the increase of the overnight capital costs to build nuclear reactors. Our results show that increasing the size of nuclear reactors is not a factor statistically significant to decrease the percentage of cost overruns, and the probit model results provide evidence that an increase in size increases the probability of having cost overruns larger than 100% (double the estimated cost). We also compare our findings to two other regions: Asia and Europe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HTGR Cost Model Users' Manual

The High Temperature Gas-Cooler Reactor (HTGR) Cost Model was developed at the Idaho National Laboratory for the Next Generation Nuclear Plant Project. The HTGR Cost Model calculates an estimate of the capital costs, annual operating and maintenance costs, and decommissioning costs for a high-temperature gas-cooled reactor. The user can generate these costs for multiple reactor outlet temperatures; with and without power cycles, including either a Brayton or Rankine cycle; for the demonstration plant, first of a kind, or nth of a kind project phases; for a single or four-pack configuration; and for a reactor size of 350 or 600 MWt. This users manual contains the mathematical models and operating instructions for the HTGR Cost Model. Instructions, screenshots, and examples are provided to guide the user through the HTGR Cost Model. This model was design for users who are familiar with the HTGR design and Excel. Modification of the HTGR Cost Model should only be performed by users familiar with Excel and Visual Basic.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reported Energy and Cost Savings from the DOE ESPC Program

The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy's Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 134 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project. For 133 of the 134 projects, there was sufficient information to compare estimated, reported, and guaranteed cost savings. For this group, the total estimated cost savings for the reporting periods addressed were $\$$95.7 million, total reported cost savings were $\$$96.8 million, and total guaranteed cost savings were $\$$92.1 million. This means that on average: ESPC contractors guaranteed 96% of the estimated cost savings, projects reported achieving 101% of the estimated cost savings, and projects reported achieving 105% of the guaranteed cost savings. For 129 of the projects examined, there was sufficient information to compare estimated and reported energy savings. On the basis of site energy, estimated savings for those projects for the previous year totaled 5.371 million MMBtu, and reported savings were 5.374 million MMBtu, just over 100% of the estimated energy savings. On the basis of source energy, total estimated energy savings for the 129 projects were 10.400 million MMBtu, and reported saving were 10.405 million MMBtu, again, just over 100.0% of the estimated energy savings.