Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Three-dimensional numerical modeling of indium phosphide Point-Contact Solar Cells

The Point-Contact Solar Cell (PCSC) geometry has proven very effective for silicon cells. To date, it has not been implemented in III-V materials. In addition, modeling such a geometry is very difficult because of its three-dimensional nature. We have developed a three-dimensional finite element modeling code (FIESTA ROC). In this paper, we present results from a three-dimensional modeling study of InP point-contact solar cells.

Clark, Ralph O.↗

Detecting gear tooth fracture in a high contact ratio face gear mesh

This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.

Zakrajsek, James J.↗

Capillary surfaces in a wedge: Differing contact angles

The possible zero-gravity equilibrium configurations of capillary surfaces u(x, y) in cylindrical containers whose sections are (wedge) domains with corners are investigated mathematically, for the case in which the contact angles on the two sides of the wedge may differ. In such a situation the behavior can depart in significant qualitative ways from that for which the contact angles on the two sides are the same. Conditions are described under which such qualitative changes must occur. Numerically computed surfaces are depicted to indicate the behavior.

Concus, Paul↗

National directory of space grant contacts

In this directory of space grant contacts of the NASA Space Grant College and Fellowship Program a listing of participating universities and other institutions are shown from all 50 states and from the District of Columbia and Puerto Rico. These 52 Space Grant State consortia currently consist of 395 institutions of higher learning, 66 industry affiliates, 26 state/local government offices, 40 nonprofit organizations, and 25 other educational entities. This directory is organized alphabetically by state and the contacts, addresses, phone numbers, and internet email addresses (where available) are included.

Source record↗

Computerized Design and Generation of Gear Drives With a Localized Bearing Contact and a Low Level of Transmission Errors

A general approach developed for the computerized simulation of loaded gear drives is presented. In this paper the methodology used to localize the bearing contact, provide a parabolic function of transmission errors, and simulate meshing and contact of unloaded gear drives is developed. The approach developed is applied to spur and helical gears, spiral bevel gears, face-gear drives, and worm-gear drives with cylindrical worms.

Litvin, F.↗

Experimental Study of Load Carrying Capacity of Point Contacts at Zero Entrainment Velocity

A capacitance technique was used to monitor the film thickness separating two steel balls while subjecting the ball-ball contact to highly stressed, zero entrainment velocity conditions. Tests were performed in a nitrogen atmosphere and utilized 52100 steel balls and a polyalphaolefin lubricant. Capacitance to film thickness accuracy was verified under pure rolling conditions using established EHL theory. Zero entrainment velocity tests were performed at sliding speeds from 6.0 to 10.0 m/s and for sustained amounts of time to 28.8 min. The protective lubricant film separating the specimens at zero entrainment velocity had a film thickness between 0.10 to 0.14 microns (4 to 6 micro in.), which corresponded to a k value of 4. The formation of an immobile surface film formed by lubricant entrapment is discussed as an explanation of the load carrying capacity at zero entrainment velocity conditions, relevant to the ball-ball contacts occurring in retainerless ball bearings.

Shogin, B. A.↗

Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement

Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.

Chern, E. James↗

The Space-Time Conservation Element and Solution Element Method-A New High-Resolution and Genuinely Multidimensional Paradigm for Solving Conservation Laws: Numerical Simulation of Shock Waves and Contact Discontinuities - 2

Without resorting to special treatment for each individual test case, the 1D and 2D CE/SE shock-capturing schemes described previously (in Part I) are used to simulate flows involving phenomena such as shock waves, contact discontinuities, expansion waves and their interactions. Five 1D and six 2D problems are considered to examine the capability and robustness of these schemes. Despite their simple logical structures and low computational cost (for the 2D CE/SE shock-capturing scheme, the CPU time is about 2 micro-secs per mesh point per marching step on a Cray C90 machine), the numerical results, when compared with experimental data, exact solutions or numerical solutions by other methods, indicate that these schemes can accurately resolve shock and contact discontinuities consistently.

Wang, Xiao-Yen↗

Determination of Principal Curvatures and Contact Ellipse for Profile Crowned Helical Gears

Helical gears with localized bearing contact of tooth surfaces achieved by profile crowning of tooth surfaces are considered. Profile crowning is provided by application of two imaginary rack-cutters with mismatched surfaces. The goal is to determine the dimensions and orientation of the instantaneous contact ellipse that requires the determination of principle curvatures of pinion-gear tooth surfaces. A simplified solution to this problem is proposed based on the approach development for correlation of principal curvatures and directions of generating and generated tooth surfaces. The obtained equations are applied for profile crowning where the normal profiles of the rack-cutters are either a circular arc or a straight line.

Feng, P.-H.↗

The Practical Implementation of Non-Contacting Laser Strain Measurements Systems

Measurement of stress and strain in rotating turbomachinery is critical to many industries. The search for a non-contacting, non-interfering, non-degrading measurement system is on going and extensive. While several methods seem promising in theory, implementation has proven troublesome. This work uncovers and quantifies these implementation issues in the context of a laser measurement system. Both a Laser Doppler Velocimeter system and a displacement laser system are utilized. It is found that the key issues are signal to noise ratio, rigid body compensation, measurement location, and conversion of intermittent measurements to a continuous signal. Accounting for these factors leads to successful measurements. These results should lead to better ideas and more practical solutions to the non-contacting, non-degrading, non-interfering strain measurement system problem.

Yunis, Isam↗

The Effect of Sliding Speed on Film Thickness and Pressure Supporting Ability of a Point Contact Under Zero Entrainment Velocity Conditions

A unique tribometer is used to study film forming and pressure supporting abilities of point contacts at zero entrainment velocity (ZEV). Film thickness is determined using a capacitance technique, verified through comparisons of experimental results and theoretical elastohydrodynamic lubrication (EHL) predictions for rolling contacts. Experiments are conducted using through hardened AISI 52 100 steel balls, Polyalphaolefin (PAO) 182 and Pentaerythritol Tetraheptanoate (PT) lubricants, and sliding speeds between 2.0 to 12.0 m/s. PAO 182 and PT are found to support pressures up to 1. 1 GPa and 0.67 GPa respectively. Protective lubricant films ranging in thickness between 90 to 2 10 nm for PAO 182 and 220 to 340 nm for PT are formed. Lubricants experience shear stresses between 14 to 22 MPa for PAO 182 and 7 to 16 MPa for PT at shear rates of 10(exp 7)/sec. The lubricant's pressure supporting ability most likely results from the combination of immobile films and its transition to a glassy solid at high pressures.

Thompson, Peter M.↗

The Effect of the Wall Contact and Post-Growth C001-Down on Defects in CdTe Crystals Grown by Contactless PVT

In crystal growth, the quality of the final material may depend, among other factors, on its interaction with the walls of the ampoule during and after the growth, and on the rate of the crystal cool-down at the end of ate the process. To investigate the above phenomena, a series of CdTe crystal growth processes was carried out, The crystals were grown by physical vapor transport without contact with the side walls of the silica glass ampoules, applying the Low Supersaturation Nucleation technique. The source temperature was 930 C, the undercooling was a few degrees. The crystals, having the diameter of 25 mm, grew at the rate of a few mm per day. The post-growth cool-down to the room temperature was conducted at different rates, and lasted from a few minutes to four days. The crystals were characterized using chemical etching low temperature luminescence, and Synchrotron White Beam X-ray Topography techniques. The dislocation (etch pit) density was measured and its distribution was analyzed by comparison with Poisson curves and with the Normalized Radial Distribution Correlation Function. It was found that the contact of the crystal with silica leads to a strain field and high (in the 105 sq cm range) dislocation (etch pit) density. Similar defect concentrations were found in crystals subjected to fast post-growth cool-down. Typical EPD values for lower cool-down rates and in regions not affected by wall interactions are in the lower 10(exp 4) sq cm range. In some areas the actual dislocation density was about 10(exp 3) sq cm or even less. No apparent effect of the cool-down rate on polygonization was observed. A fine structure could be discerned in low-temperature PL spectra of crystals with low dislocation density.

Palosz, W.↗

Caustics and Caustic-Interference in Measurements of Contact Angle and Flow Visualization Through Laser Shadowgraphy

As one of the basic elements of the shadowgraphy optical system, the image of the far field from the droplet implicates plentiful information on the droplet profile. An analysis of caustics by wave theory shows that a droplet with a cylindrically symmetric Gaussian-hill-type profile produces a circular directional caustic in far field, which arises from the singularities (inflection line on the surface). The sessile liquid droplets, which profiles are restricted by surface tension, usually have a 'protruding foot' where the surface inflects. Simple geometrical optics indicates that the circular caustic stemming from the surface inflection at the protruding-foot takes the shape of the outmost ring on the image of the far field. It is the diameter of the outmost ring that is used as one of the key parameters in the measurements of contact angle through the laser shadowgraphic method. Different surface characteristics of the droplets produce different type of caustics, and therefore, the shape of the caustics can be used to determine the surface property of the sessile droplets. The present paper describes the measurement method of contact angIe using the circular caustics and the estimation of the protruding-foot height through the caustic interference.

Chao, David F.↗

Defect, Kinetics and Heat Transfer of CDTE Bridgman Growth without Wall Contact

A detached growth mechanism has been proposed, which is similar to that proposed by Duffar et al. and used to study the current detached growth system. From numerical results, we can conclude that detached growth will more likely appear if the growth and wetting angles are large and meniscus is flat. Detached thickness is dependent on growth angle, wetting angle, and gap width and shape of the fins. The model can also explain why the detached growth will not happen for metals in which the growth angle is almost zero. Since the growth angle of CdZnTe cannot be changed, to promote detached growth, the number density of the fins should be low and the wetting angle should be high. Also, a much smaller gap width of the fins should be used in the ground experiment and the detached gap width is much smaller. The shape of the fins has minor influence on detached growth. An integrated numerical model for detached solidification has been developed combining a global heat transfer sub-model and a wall contact sub-model. The global heat transfer sub-model accounts for heat and mass transfer in the multiphase system, convection in the melt, macro-segregation, and interface dynamics. The location and dynamics of the solidification interface are accurately tracked by a multizone adaptive grid generation scheme. The wall contact sub-model accounts for the meniscus dynamics at the three-phase boundary. Simulations have been performed for crystal growth in a conventional ampoule and a designed ampoule to understand the benefits of detached solidification and its impacts on crystalline structural quality, e.g., stoichiometry, macro-segregation, and stress. From simulation results, both the Grashof and Marangoni numbers will have significant effects on the shape of growth front, Zn concentration distribution, and radial segregation. The integrated model can be used in designing apparatus and determining the optimal geometry for detached solidification in space and on the ground.

Larson, D. J., Jr.↗

Contact Analog/Compressed Symbology Heading Tape Assessment

A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

Shively, R. Jay↗

Influence of Contact Angle, Growth Angle and Melt Surface Tension on Detached Solidification of InSb

We extended the previous analysis of detached solidification of InSb based on the moving meniscus model. We found that for steady detached solidification to occur in a sealed ampoule in zero gravity, it is necessary for the growth angle to exceed a critical value, the contact angle for the melt on the ampoule wall to exceed a critical value, and the melt-gas surface tension to be below a critical value. These critical values would depend on the material properties and the growth parameters. For the conditions examined here, the sum of the growth angle and the contact angle must exceed approximately 130, which is significantly less than required if both ends of the ampoule are open.

Wang, Yazhen↗

The historic biogeography of India: isolation or contact?

Geophysical maps depicting continental movement have consistently shown India, as it moved northward, to be located far out in the Tethys Sea. India split off from the African east coast about 148 m.y.a. From that time onward, according to almost all geophysical accounts, India was isolated from all of other continents until the early Miocene when it made contact with Eurasia. But the biological data, both fossil and Recent, indicate that this concept cannot be correct. If India had really existed as an isolated, oceanic continent for about 100 m.y., it should have developed a peculiar biota with many endemic genera and families in its terrestrial and shallow marine habitats. But there are virtually no remains of organisms indicating that India was isolated for any substantial time (millions of years). Instead, we find that almost all Indian taxa were possessed in common with other continents. As time went on, the northern relationships became stronger and the southern ones weaker. Most of the recent geophysical accounts show India not making contact with Eurasia until the early Miocene, but fossil materials show that this event must have taken place by the early Eocene. It has been postulated that, as India moved northward, it created a biogeographic barrier that separated marine fish populations and resulted in the east-west provinces that are now apparent in the Indian Ocean. At the same time, the barrier effect was supposed to have resulted in the formation of sister species that are now located far apart. Information currently available indicates that most living, tropical marine species are probably not over 3 m.y. old. Consequently, the northward movement of India, which took place primarily between 148 and 50 m.y.a., could have no bearing on the relationships of modern species.

NASA Discipline Exobiology↗

Plantar soft tissue thickness during ground contact in walking

A technique is introduced for the measurement of plantar soft tissue thickness during barefoot walking. Subjects stepped into an adjustable Plexiglas frame which ensured that the required bony landmarks were appropriately positioned relative to a linear ultrasound probe connected to a conventional 7.5 MHz ultrasound scanner. Clear images of the metatarsal condyles or other foot bones were obtained throughout ground contact. Subsequent analysis of the video taped images using a motion analysis system allowed the tissue displacement to be calculated as a function of time. The tissue underneath the second metatarsal head was shown to undergo an average maximum compression of 45.7% during the late stages of ground contact during first step gait in a group of five normal subjects with a mean unloaded tissue thickness of 15.2 mm. The technique has a number of applications, including use in the validation of deformation predicted by finite element models of the soft tissue of the foot, and the study of alterations in the cushioning properties of the heel by devices which constrain the displacement of the heel pad.

Non-NASA Center↗