Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Managing Complex Network Operation with Predictive Analytics

Complex networks play an important role in modern societies. Their failures, such as power grid blackouts, would lead to significant disruption of people’s life, industry and commercial activities, and result in massive economic losses. Operation of these complex networks is an extremely challenging task due to their complex structures, wide geographical coverage, complex data/information technology systems, and highly dynamic and nonlinear behaviors. None of the complex network operation is fully automated; human-in-the-loop operation is critical. Given the complexity involved, there may be thousands of possible topological configurations at any given time. During an emergency, it is not uncommon for human operators to examine thousands of possible configurations in near real-time to choose the best option and operate the network effectively. In today’s practice, network operation is largely based on experience with very limited real-time decision support, resulting in inadequate management of complex predictions and inability to anticipate, recognize, and respond to situations caused by human errors, natural disasters, and cyber attacks. A systematic approach is needed to manage the complex operation paradigms and choose the best option in a near-real-time manner. This paper applies predictive analytics techniques to establish a decision support system for complex network operation management and help operators to predict potential network failures and adapt the network to adverse situations. The resultant decision support system enables continuous monitoring of network performance and turns large amounts of data into actionable information. Examples with actual power grid data are presented to demonstrate the capability of this proposed decision support system.

97 MATHEMATICS AND COMPUTING↗

A comparison of Eulerian and semi-Lagrangian approaches for modeling stream water quality

This paper describes and compares some of the advantages and limitations of Eulerian and Lagrangian approaches to water quality modeling and introduces a mixed Eulerian-Lagrangian (or semi-Lagrangian) methodology that captures the strengths of both approaches. The semi-Lagrangian modeling approach is applied to advection-dominated rivers, and flexibly ensures unconditional stability for all time step durations and grid segmentations. The semi-Lagrangian modeling approach is demonstrated by applying it to estimate the dissolved oxygen concentrations in the Sava River in Slovenia, focusing on aspects of the methodology and findings that would be of broad interest to managers of water quality in fluvial water bodies. Results of comparisons of the semi-Lagrangian model with the Eulerian-based QUAL2K model in steady and non-steady scenarios demonstrate that while both models are fully capable of producing satisfactory results when optimally configured, the semi-Lagrangian approach offers accuracy and stability without sensitivity to the interaction of time step size and computational grid segmentation scheme.

Sava River↗

SHARP pre-release v1.0 - Current Status and Documentation

The NEAMS Reactor Product Line effort aims to develop an integrated multiphysics simulation capability for the design and analysis of future generations of nuclear power plants. The Reactor Product Line code suite’s multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. In this report, building on a several previous report issued in September 2014, we describe our continued efforts to integrate thermal/hydraulics, neutronics, and structural mechanics modeling codes to perform coupled analysis of a representative fast sodium-cooled reactor core in preparation for a unified release of the toolkit. The work reported in the current document covers the software engineering aspects of managing the entire stack of components in the SHARP toolkit and the continuous integration efforts ongoing to prepare a release candidate for interested reactor analysis users. Here we report on the continued integration effort of PROTEUS/Nek5000 and Diablo into the NEAMS framework and the software processes that enable users to utilize the capabilities without losing scientific productivity. Due to the complexity of the individual modules and their necessary/optional dependency library chain, we focus on the configuration and build aspects for the SHARP toolkit, which includes capability to autodownload dependencies and configure/install with optimal flags in an architecture-aware fashion. Such complexity is untenable without strong software engineering processes such as source management, source control, change reviews, unit tests, integration tests and continuous test suites. Details on these processes are provided in the report as a building step for a SHARP user guide that will accompany the first release, expected by Mar 2016.

Mahadevan, Vijay S.↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Business Case for Nuclear Plant Control Room Modernization

This paper presents a generic business case for implementation of technology that supports Control Room Modernization (CRM). The analysis presented in two forms; 1) a standalone technology upgrade, and 2) a technology upgrade that is built upon and incremental to a prior business case created for Mobile Work Packages (MWP). The business case contends that advanced communication and networking and analytical technologies will allow NPP to conduct control room operations with improved focus by reducing human factors and redundant manpower, and therefore operate with fewer errors. While some labor savings can be harvested in terms of overtime, the majority of savings are demonstrated as reduced time to take the plant off line and bring back on line in support of outages. The benefits are quantified to a rough order of magnitude that provides directional guidance to NPPs that are interested in developing a similar business case. This business case focuses on modernization of the operator control room and does not consider a complete overhaul and modernization of a plants instrument and control systems. While operators may be considering such an investment at their plants, the sizable capital investment required is not likely supported by a cost/benefit analysis alone. More likely, it is driven by obsolescence and reliability issues, and requires consideration of mechanical condition of plant systems, capital depreciation, financing, relicensing and overall viability of the plant asset over a 20-year horizon in a competitive market. Prior studies [REF] have indicated that such a modernization of plant I&C systems, alone or as part of a larger modernization effort, can yield very significant reductions in O&M costs. However, the depth of research and analysis required to develop a meaningful business case for a plant modernization effort is well beyond the scope of this study. While CRM as considered in this study can be easily integrated as part of grander plant modernization effort, it can also be considered as a stand-alone project, implemented as a supervisorial layer over and above existing systems. CRM is enabled by a suite of technologies, which are described in further detail in the body of this report. They include: • Modernized control room with interactive displays • High-bandwidth wireless networks • Mobile devices • Component identification technology • Mobile wireless video cameras • Smart or task based operator displays • Computer-Based Procedures (CBP)/Automated Mobile Work Packages (MWP) • Intelligent plant configuration • Advanced data analytics An analysis was conducted to determine how these technologies might impact outage operations at an NPP. The analysis concluded that outage management capabilities would be improved with application of these technologies, and result in annual benefits for the plant. These improved capabilities were identified and described in further detail in this report. • Reduction in need redundant manpower (verification, etc) • Improved critical path shutdown and restart duration during outages • Reduction in human factors and errors • Remote watches • Paperless outage coordination • Bulk work optimization

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AVANTech's Liquid Radwaste (LRW) Processing System Upgrade at the Farley Nuclear Plant - 20328

This paper looks at the Liquid Radioactive Waste (LRW) processing system configuration at Joseph M. Farley Nuclear Plant (Plant Farley). A combination of factors led the staff at Plant Farley to seek a better way to manage and process liquid waste. These factors were: - Reduce effluent activity; - Reduce waste volume; - Improve cost efficiency. The LRW processing system changes made at Plant Farley are identified and discussed. The information and technologies cited in this paper are directly applicable to other nuclear power plants who might contemplate an upgrade of LRW processing systems or of individual system components. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bounding Pressure and Flammability Evaluations of Aluminum-Clad Spent Nuclear Fuel Department of Energy Standard Canisters

This paper presents bounding pressure and flammability evaluations for DOE Standard Canister loaded with DOE-managed aluminum-clad spent nuclear fuel (ASNF). The objective of these evaluations is to gain confidence in the safety and feasibility of possible loading configurations for extended (>50 years) periods of dry storage, with particular focus on the dry storage canister pressures and potential for formation of a flammable atmosphere. The primary concern about the extended dry storage of ASNF is radiolytic gas generation. The aluminum cladding of these materials tends to corrode, and these corrosion products—typically aluminum oxides, such as boehmite, bayerite, or gibbsite—could carry water. This makes ASNF dry storage canisters difficult to dry. The gamma radiation field in dry storage environments could cause a radiolytic breakdown of residual water, forming chemical species such as molecular hydrogen (H2). The release of these species could increase the canister pressure and lead to the generation of a flammable canister atmosphere. The bounding evaluations presented within this study surmise conservative, but credible, conditions and processes. This includes the assumption of a full breakdown of a large quantity of free, physisorbed, and chemisorbed water (bound in a trihydrate, i.e., Al2O3 • 3H2O, layer). The considered dry storage configurations include a ~3 m (10 ft) long, ~46 cm (18 in) diameter (10 x 18) DOE Standard Canister loaded with 32 Advanced Test Reactor (ATR) ASNF elements, and a ~3 m (10 ft) long, ~61 cm (24 in) (10 x 24) diameter DOE Standard Canister loaded with 40 ATR ASNF elements. While the results of this study indicate the possibility of atmospheric hydrogen concentrations above the lower flammability limit, insufficient concentrations of oxygen will prevent the formation of flammable atmospheres. The maximum credible pressures remain well within the structural limits of the DOE Standard Canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Scalable Transmission and Distribution Co-simulation Platform for IBR-heavy Power Systems

The integration of Inverter-Based Resources (IBRs) into power systems, including both transmission and distribution networks, poses challenges for studying grid dynamic behaviours under various operating conditions and system events. This paper addresses the urgent need to investigate the influence of IBRs on grid dynamics, and their potential to enhance power system reliability and resilience. We propose a flexible, scalable transmission and distribution co-simulation platform, using opensource tools only for assessing the impact of grid-following (GFL) and grid-forming (GFM) IBRs on dynamic stability at various renewable penetration levels (up to 100%). This platform enables researchers to explore different contingencies at transmission, distribution, or both, providing a comprehensive evaluation of grid status. A series of case studies, including both small and large T&D systems with varying GFL/GFM configurations and contingencies, have been conducted. The results not only robustly validate our co-simulation framework, but also provide invaluable insights for effective IBR management in the power grid.

grid management↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a liquid heat exchange circuit. The system includes at least one battery in thermal communication with the liquid heat exchange circuit. The system includes a controller operatively connected to the liquid heat exchange circuit. The controller is configured and adapted to variably select whether heat will be rejected to the liquid heat exchange circuit. The system includes at least one heat exchanger positioned on the liquid heat exchange circuit. The at least one heat exchanger is a liquid-air heat exchanger or a liquid-liquid heat exchanger. A method for controlling a thermal management system for an air vehicle includes determining an expected temperature of at least one battery, and cooling the at least one battery with a cooling device if the expected temperature exceeds a pre-determined expected temperature threshold.

Rheaume, Jonathan↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and apparatus for selective and power-aware memory error protection and memory management

A method for providing selective memory error protection responsive to a predictable failure notification associated with at least one portion of a memory in a computing system includes: obtaining an active error correcting code (ECC) configuration corresponding to the portion of the memory; determining whether the active ECC configuration is sufficient to correct at least one error in the portion of the memory affected by the predictable failure notification; when the active ECC configuration is insufficient to correct the error, determining whether data corruption can be tolerated by an application running on the computing system; when data corruption cannot be tolerated by the application, determining whether a stronger ECC level is available and, if a stronger ECC level is available, increasing a strength of the active ECC configuration; and when data corruption can be tolerated, performing page reassignment and aggregation of non-critical data.

97 MATHEMATICS AND COMPUTING↗

Development and Testing of a High Level Waste Slurry Sampling Technique to Support Hanford Waste Processing - 17164

The Hanford Tank Operations Contractor must demonstrate the capability to adequately sample staged high-level waste feed. The sampler employed must have accuracy and precision performance that allow the Tank Operations Contractor (TOC) to meet the Waste Treatment and Immobilization Plant (WTP) Waste Acceptance Criteria Data Quality Objectives (DQO). A full-scale sampling loop was used at a test facility to develop and demonstrate sampler capability. This paper will discuss the modifications to a sampler configuration previously tested - modifications focused on the improvement of the accuracy of test results. This work targets one of the remaining technical issues with the high-level waste treatment mission at Hanford. The sampling method employed must support both Tank Operations and Waste Treatment and Immobilization Plant requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the TOC's Chief Technology Office in conjunction with the One System Integrated Project Team. Results of the testing showed that performance of the Isolok{sup R} sampler, chosen for implementation, can be greatly improved by modifying the systems configuration to provide accurate, repeatable results for Hanford's simulated high level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Offsite Source Recovery Program; High Activity Beta Gamma Removal, Transport and Disposition - 19663

The Department of Energy's (DOE) National Nuclear Security Administration's (NNSA) Office of Radiological Security's (ORS) Off-Site Source Recovery Program (OSRP) has been tasked with the removal and disposition of radioactive sealed sources in the interest of national security and public health and safety. It is the mission of the program to recover radioactive sources to prevent them from falling into the hands of individuals who would use this material for malicious intent. OSRP is a collaborative effort involving Los Alamos National Laboratory (LANL), Idaho National Laboratory (INL), and Lawrence Livermore National Laboratory (LLNL). At the inception of the program, Pu-239 was the only isotope acceptable for recovery. As a wider security scope developed, OSRP expanded its mission to include the recovery of other sources that posed a potential risk to national security, health, and safety. Starting in 2004, OSRP began recovering cesium and cobalt devices, largely from medical, research, and industrial facilities. These disused higher-activity devices present a burden to licensees in terms of security, and demand for OSRP's assistance in removing them has been high. Today, OSRP removes around 40 high-activity devices per year in support of domestic demand as well as ORS's Cesium Irradiator Replacement Project (CIRP). This represents an average of over 50,000 Ci of Cs-137 and Co-60 removed from the private sector each year for permanent disposition. A major component of this effort is the use of the proper shipping container to transport the devices. As a way to increase transportation capabilities ORS has developed two new Type B containers. The most recently completed of these containers, the 435-B, is currently certified to transport Gammators and Gammacell-1000, -3000, and -40 irradiators in an overpack configuration. This provides greater capacity and flexibility to safely and effectively transport these devices, for which acceptable shipping configurations had been previously limited. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The hydrothermal reactions of monosodium titanate, crystalline silicotitanate and sludge in the modular salt process: a literature survey

The use of crystalline silicotitanate (CST) is proposed for an at-tank process to treat High Level Waste at the Savannah River Site. The proposed configuration includes deployment of ion exchange columns suspended in the risers of existing tanks to process salt waste without building a new facility. The CST is available in an engineered form, designated as IE-911-CW, from UOP. Prior data indicates CST has a proclivity to agglomerate from deposits of silica rich compounds present in the alkaline waste solutions. This report documents the prior literature and provides guidance for the design and operations that include CST to mitigate that risk. The proposed operation will also add monosodium titanate (MST) to the supernate of the tank prior to the ion exchange operation to remove strontium and select alpha-emitting actinides. The cesium loaded CST is ground and then passed forward to the sludge washing tank as feed to the Defense Waste Processing Facility (DWPF). Similarly, the MST will be transferred to the sludge washing tank. Sludge processing includes the potential to leach aluminum from the solids at elevated temperature (e.g., 65 C) using concentrated (3M) sodium hydroxide solutions. Prior literature indicates that both CST and MST will agglomerate and form higher yield stress slurries with exposure to elevated temperatures. This report assessed that data and provides guidance on minimizing the impact of CST and MST on sludge transfer and aluminum leaching sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02028

Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02028. For those attributes that were also measured during the field surveillance, no significant changes were observed. Four conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer; (2) The lead shield height exceeds drawing requirements; (3) Mold was observed on the lower fiberboard subassembly; and (4) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the disposition by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes. The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

XAFS Study of the Chemical and Structural States of Technetium in Fe(III) Oxide Co-precipitates

XAFS has been used to study the chemical state and structural environment of technetium in Fe(III) oxide co-precipitates. {sup 99}Technetium is an abundant fission product which poses a significant environmental hazard due to its long half-life, abundance in nuclear wastes, and environmental mobility as the pertechnetate ion [Tc(VII)O{sub 4}{sup -}] under oxidizing conditions. Tetravalent Tc [Tc(IV)] is the stable valence state under reducing or anoxic conditions where its environmental mobility is significantly lowered by formation of a sparingly soluble, hydrated amorphous oxide precipitate [Tc(IV)O{sub 2} {center_dot} nH{sub 2}O(s)]. We have been studying the kinetics and solid products resulting from abiotic reduction of Tc(VII)O{sub 4}{sup -} by aqueous, adsorbed, and structural Fe(II) to provide insights on Tc migration in microaerophilic groundwaters. The reduction reaction yields Fe/Tc precipitates of variable structures that have not been previously studied. For the homogeneous reaction with aqueous Fe(II) at relatively high Tc:Fe concentrations, the predominant redox product is a solid containing Tc(IV) dimers attached in a bidentate edge-sharing configuration to FeO6 octahedra on the surface or unoccupied interior sites of a ferrihydrite-like precipitate. A similar ferrihydrite-type solid is formed on the surface of Fe oxide minerals such a hematite and goethite following the heterogeneous reaction of Tc(VII)O{sub 4}{sup -} with surface-complexed Fe(II). These co-precipitates greatly slow the oxidation rate of Tc(IV) relative to amorphous Tc(IV)O{sub 2} {center_dot} nH{sub 2}O(s), possibly allowing for the long term sequestration of {sup 99}Tc in stable (bio)geochemical mineral forms that may reduce the long term environmental risk of {sup 99}Tc subsurface contamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Integrated Platform for Collaborative Data Analytics

While collaboration among data scientists is a key to organizational productivity, data analysts face significant barriers to achieving this end, including data sharing, accessing and configuring the required computational environment, and a unified method of sharing knowledge. Each of these barriers to collaboration is related to the fundamental question of knowledge management “how can organizations use knowledge more effectively?”. In this paper, we consider the problem of knowledge management in collaborative data analytics and present ShareAL, an integrated knowledge management platform, as a solution to that problem. The ShareAL platform consists of three core components: a full stack web application, a dashboard for analyzing streaming data and a High Performance Computing (HPC) cluster for performing real time analysis. Prior research has not applied knowledge management to collaborative analytics or developed a platform with the same capabilities as ShareAL. ShareAL overcomes the barriers data scientists face to collaboration by providing intuitive sharing of data and analytics via the web application, a shared computing environment via the HPC cluster and knowledge sharing and collaboration via a real time messaging application.

Oesch, T↗

Integrating and Characterizing HPC Task Runtime Systems for hybrid AI-HPC workloads

Scientific workflows increasingly involve both HPC and machine-learning tasks, combining MPI-based simulations, training, and inference in a single execution. Launchers such as Slurm’s srun constrain concurrency and throughput, making them unsuitable for dynamic and heterogeneous workloads. We present a performance study of RADICAL-Pilot (RP) integrated with Flux and Dragon, two complementary runtime systems that enable hierarchical resource management and high-throughput function execution. Using synthetic and production-scale workloads on Frontier, we characterize the task execution properties of RP across runtime configurations. RP+Flux sustains up to 930 tasks/s, and RP+Flux+Dragon exceeds 1,500 tasks/s with over 99.6% utilization. In contrast, srun peaks at 152 tasks/s and degrades with scale, with utilization below 50%. For IMPECCABLE.v2 drug discovery campaign, RP+Flux reduces makespan by 30–60% relative to srun/Slurm and increases throughput more than four times on up to 1,024. These results demonstrate hybrid runtime integration in RP as a scalable approach for hybrid AI-HPC workloads.

HPC-AI↗