Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

VAIM-CFF: a variational autoencoder inverse mapper solution to Compton form factor extraction from deeply virtual exclusive reactions

We develop a new methodology for extracting Compton form factors (CFFs) from deeply virtual exclusive reactions such as the unpolarized DVCS cross section using a specialized inverse problem solver, a variational autoencoder inverse mapper (VAIM). The VAIM-CFF framework not only allows us access to a fitted solution set possibly containing multiple solutions in the extraction of all 8 CFFs from a single cross section measurement, but also accesses the lost information contained in the forward mapping from CFFs to cross section. We investigate various assumptions and their effects on the predicted CFFs such as cross section organization, number of extracted CFFs, use of uncertainty quantification technique, and inclusion of prior physics information. We then use dimensionality reduction techniques such as principal component analysis to visualize the missing physics information tracked in the latent space of the VAIM framework. Through re-framing the extraction of CFFs as an inverse problem, we gain access to fundamental properties of the problem not comprehensible in standard fitting methodologies: exploring the limits of the information encoded in deeply virtual exclusive experiments.

Accelerator Physics↗

Extraction of the Compton Form Factor H from recent DVCS measurements at Jefferson Lab

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A and the beam spin asymmetries measured in Hall B at Jefferson Laboratory. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20–50 % uncertainty. We discuss our results and compare to other extractions as well as to the popular VGG model. We pay extra attention to the estimation of systematic errors on the extraction of H.

43 PARTICLE ACCELERATORS↗

Coherent Stacking Scheme for Inverse-Compton Scattering at MHz Repetition Rates

An experiment to produce 1-MeV gamma rays via Compton back-scattering of infrared photons on 250-MeV electron bunches is currently in preparation at the Fermilab Accelerator Science & Technology (FAST) facility. To increase the gamma-ray flux the energy of the infrared laser pulses are planned to be amplified within the interaction region using a resonant cavity. This passive amplifier composed of a Fabry-Perot cavity will allow the laser pulse bunches to coherently and constructively stack. Our estimates, based on theoretical models, show that the laser pulse energy can be increased from approximately 1-2 mJ at the exit of the last active amplifier to 5 -10 mJ at the interaction point when the laser repetition rate is set at the nominal value of 3 MHz. This paper details the cavity design option(s) and associated wave-optic simulations.

43 PARTICLE ACCELERATORS↗

The Effectiveness of the Compton Radiography Snout Electron Deflection Yoke and its Application as an Electron Spectrometer

The Compton Radiography Snout (CRS) is a prototype of a diagnostic called the High Energy X Ray Imager (HEXRI) that will be used to record radiographs of imploding fuel cells on NIF. With these radiographs, it is possible to characterize the density and symmetry of the imploding fuel capsule. When the advanced radiography capability is used to generate the high energy x‐rays used to backlight the radiographs, hot electrons are also produced. In order to record a clear radiograph, these electrons are deflected away from the imaging plane of the CRS using a permanent magnetic yoke. In an effort to increase the number of parameters that can be used during the scaling of the CRS for NIF, an investigation is underway to add an electron spectrometer capability to the CRS to measure the electron spectrum produced during the ARC backlighting.

42 ENGINEERING↗

Study of Generalized Parton Distributions and Deeply Virtual Compton Scattering on the nucleon with the CLAS and CLAS12 detectors at the Jefferson Laboratory

The exclusive leptoproduction of a real photon is considered to be the "cleanest" way to access the Generalized Parton Distribution (GPD). This process is called Deeply Virtual Compton Scattering (DVCS) lN {yields} lN{gamma} , and is sensitive to all the four GPDs. Measuring the DVCS cross section is one of the main goals of this thesis. In this thesis, we present the work performed to extract on a wide phase-space the DVCS cross-section from the JLab data at a beam energy of 6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-Wakefield driven compact Compton scattering gamma-ray source

We propose to demonstrate a novel x-ray and gamma-ray light source based on laser-plasma electron acceleration and Compton scattering at the Jupiter Laser Facility at LLNL. This will provide a new versatile and compact light source capability at the laboratory with very broad scientific applications that are of interest to many disciplines. The source’s synchronization with the seed laser system at a femtosecond time scale (i-e, at which chemical reactions occur) will allow scientists to perform pump-probe experiments with x-ray and gamma-ray beams. Across the laboratory, this will be a new tool for nuclear science, high energy density physics, chemistry, biology, or weapons studies.

42 ENGINEERING↗

Compton Scattering Polarimetry for the Determination of the Proton's Weak Charge Through Measurements of the Parity-Violating Asymmetry of 1H(e,e')p

The Standard Model has been a theory with the greatest success in describing the fundamental interactions of particles. As of the writing of this dissertation, the Standard Model has not been shown to make a false prediction. However, the limitations of the Standard Model have long been suspected by its lack of a description of gravity, nor dark matter. Its largest challenge to date, has been the observation of neutrino oscillations, and the implication that they may not be massless, as required by the Standard Model. The growing consensus is that the Standard Model is simply a lower energy effective field theory, and that new physics lies at much higher energies. The Q weak Experiment is testing the Electroweak theory of the Standard Model by making a precise determination of the weak charge of the proton (Q p w ). Any signs of "new physics" will appear as a deviation to the Standard Model prediction. The weak charge is determined via a precise measurement of the parity-violating asymmetry of the electron-proton interaction via elastic scattering of a longitudinally polarized electron beam of an un-polarized proton target. The experiment required that the electron beam polarization be measured to an absolute uncertainty of 1%. At this level the electron beam polarization was projected to contribute the single largest experimental uncertainty to the parity-violating asymmetry measurement. This dissertation will detail the use of Compton scattering to determine the electron beam polarization via the detection of the scattered photon. I will conclude the remainder of the dissertation with an independent analysis of the blinded Q weak .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low momentum transfer measurements of pion electroproduction and virtual Compton scattering at the Delta resonance

Non-spherical components of the nucleon wave function are measured through p(e,e'p)π 0 experiment at the Δ + (1232) resonance for Q 2 = 0.04, 0.09, and 0.13 (GeV=c) 2 utilizing the Jefferson National Accelerator Facility (JLab) pulsed beam and Hall A spectrometers. The new data extend the measurements of the Coulomb quadrupole amplitude to the lowest momentum transfer ever reached. The results disagree with predictions of constituent quark models and are in reasonable agreement with dynamical calculations that include pion cloud effects, chiral effective field theory and lattice calculations. The reported measurements indicate that improvement is required to the theoretical calculations and provide valuable input that will allow their refinements. The Coulomb to magnetic multipole ratio (CMR) and generalized polarizability (GP) of the nucleon are also measured through virtual Compton scattering (VCS) for Q 2 = 0.2(GeV=c) 2 utilizing the Mainz Microtron (MAMI) continuous beam and A1 spectrometers. This data represents the first low Q 2 GP measurement at the Δ + (1232) resonance. The GP measurement explores a region where previous data and theoretical calculations disagree. The CMR measurement will be the first VCS extraction to compare with world data generated through pion electroproduction. The Dispersion Relation (DR) model used for the VCS extraction provides a new theoretical framework for the data signal and backgrounds that is largely independent from the pion electroproduction models. The independence of the DR from the traditional models provides a strong crosscheck on the ability of the models to isolate the data signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverse compton light source: a compact design proposal

In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels found at large facilities than ever before. The design process, including the development between subsequent iterations, is presented here in detail, with the simulation results for this groundbreaking X-ray source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directional Unfolded Source Term (DUST) for Compton Cameras.

A Directional Unfolded Source Term (DUST) algorithm was developed to enable improved spectral analysis capabilities using data collected by Compton cameras. Achieving this objective required modification of the detector response function in the Gamma Detector Response and Analysis Software (GADRAS). Experimental data that were collected in support of this work include measurements of calibration sources at a range of separation distances and cylindrical depleted uranium castings.

47 OTHER INSTRUMENTATION↗

Phase-Space Manipulations of Electron Beams for X-Ray Free-Electron Lasers and Inverse Compton Scattering Sources [Thesis]

This dissertation describes advanced techniques of phase space manipulations of the electron beam for improving performance and efficiency of high brightness X-ray light sources based on the free-electron Laser (FEL) and inverse-Compton scattering (ICS) processes. In particular, it first discusses a novel bunch-compression scheme based on a double transverseto-longitudinal phase-space exchanger – dubbed emittance exchanger (EEX) – separated by a demagnifying transverse-optics system. While the outline of the scheme is quite sophisticated, the basic physics behind it is quite straight-forward. The benefits and disadvantages of these scheme are compared to the conventional approach of compressing a bunch using a magnetic bunch-compression chicane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Compton

This propagates blackbody Xrays within a standard atmosphere from a point source to the point of first Compton interaction, depositing energy in accordance with the Klein-Nishijina formula. Energy distributions are then plotted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deeply Virtual Compton Scattering on the Proton in Hall A at Jefferson Lab

The structure of nucleons as they are composed of quarks and gluons is not well understood. Non-perturbative methods (such as lattice-QCD) describing quark/gluon interactions are ongoing in development, but still cannot fully reproduce the structure of hadrons. Among the observables which describe longitudinal momentum and transverse position of partons, generalized parton distributions (GPDs) describe the correlations between the two, and are accessible through p(right-arrow e;e'y)p scattering experiments in the Bjorken limit when factorization holds. A complete understanding of these functions will help us to better understand the structure of nucleons. Experiment E12-06-114 was performed by JLab's DVCS Hall A Collaboration in 2014 and 2016. Using a polarized electron beam and a liquid hydrogen target, the collaboration measured cross sections for the exclusive reaction p(right-arrow e;e'y)p at xB=0.36, 0.48, and 0.60,3 .2 lte Q2 lte 9.00, and -1.28 lte t lte -0.69. This dissertation details the analysis and results of measuring the p(right-arrow e;e'y)p cross section at xB=0.48. The measured cross section results allow us to demonstrate the validity of factorization in our kinematic regime, and extract Compton Form Factor combinations important for understanding GPDs. Additionally, the cross section results are used to test existing GPD models, KM10a and KM15.

Johnson, Alexa N.↗

November 2016 HERMES Outdoor Shot Series 10268-313: Spherical Compton Diodes

In November 2016, the High-Energy Radiation Megavolt Electron Source (HERIVIES)-III gamma simulator was used in a series of physics experiments. As part of the environmental characterization, six Spherical Compton Diodes (SCDs) were fielded in order to measure the dose rate at various locations. This report documents the locations, calibration, compensation, and analysis of these sensors. Several short studies are conducted of the SCD signals examining their change with respect to distance, comparison to other sensors and historical data, evaluation of the log-derivative, and signal behavior with a partially obscured converter. Recommendations for future work includes study and extension of SCD bandwidth, characterization of the HERMES-III output spectrum variability, and study of sensor signals with the courtyard shielded from the top of the Magnetically Insulated Transmission Line (MITL).

61 RADIATION PROTECTION AND DOSIMETRY↗

BYU Capstone Next Generation Vacuum Compton Detector

This BYU Capstone Team Gamma final poster summarizes the work of the team towards a next generation vacuum Compton detector (VCD) for the Nevada National Security Site. The NNSS sponsored this team. Amber Guckes was the mentor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

Both technical and simulation progress has been made toward implementing a laser inverse Compton scattering diagnostic on the DIII-D tokamak. This is a novel diagnostic which uses a short (sub-ns) pulse laser together with a fast (sub-ns) gated x-ray detector to measure relativistic electrons inside a tokamak plasma. The study of these relativistic electrons is important to make sure they can be removed from any tokamak-based power reactor, as they could damage vessel walls and cooling lines. This diagnostic is completely new for magnetic fusion research and has never been implemented before on a tokamak. It is found that good signals and radial profiles could be obtained with an optimized high-energy (7 Joule) laser. Using a standard off-the-shelf Nd:YAG (0.7 Joule) laser would give some signals above the noise but no ability to measure the relativistic electron radial profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗