Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)↗

Superconductivity for Large Scale Wind Turbines

A conceptual design has been completed for a 10MW superconducting direct drive wind turbine generator employing low temperature superconductors for the field winding. Key technology building blocks from the GE Wind and GE Healthcare businesses have been transferred across to the design of this concept machine. Wherever possible, conventional technology and production techniques have been used in order to support the case for commercialization of such a machine. Appendices A and B provide further details of the layout of the machine and the complete specification table for the concept design. Phase 1 of the program has allowed us to understand the trade-offs between the various sub-systems of such a generator and its integration with a wind turbine. A Failure Modes and Effects Analysis (FMEA) and a Technology Readiness Level (TRL) analysis have been completed resulting in the identification of high risk components within the design. The design has been analyzed from a commercial and economic point of view and Cost of Energy (COE) calculations have been carried out with the potential to reduce COE by up to 18% when compared with a permanent magnet direct drive 5MW baseline machine, resulting in a potential COE of 0.075 $\$$/kWh. Finally, a top-level commercialization plan has been proposed to enable this technology to be transitioned to full volume production. The main body of this report will present the design processes employed and the main findings and conclusions.

17 WIND ENERGY↗

FY 17 Q1 Commercial integrated heat pump with thermal storage milestone report

The commercial integrated heat pump with thermal storage (AS-IHP) offers significant energy saving over a baseline heat pump with electric water heater. The saving potential is maximized when the AS-IHP serves coincident high water heating and high space cooling demands. A previous energy performance analysis showed that the AS-IHP provides the highest benefit in the hot-humid and hot-dry/mixed dry climate regions. Analysis of technical potential energy savings for these climate zones based on the BTO Market calculator indicated that the following commercial building market segments had the highest water heating loads relative to space cooling and heating loads education, food service, health care, lodging, and mercantile/service. In this study, we focused on these building types to conservatively estimate the market potential of the AS-IHP. Our analysis estimates maximum annual shipments of ~522,000 units assuming 100% of the total market is captured. An early replacement market based on replacement of systems in target buildings between 15 and 35 years old was estimated at ~136,000 units. Technical potential energy savings are estimated at ~0.27 quad based on the maximum market estimate, equivalent to ~13.9 MM Ton CO2 emissions reduction.

42 ENGINEERING↗

Chemical Industry Corrosion Management: A Comprehensive Information System (ASSET 2). Final Report

The research sponsored by this project has greatly expanded the ASSET corrosion prediction software system to produce a world-class technology to assess and predict engineering corrosion of metals and alloys corroding by exposure to hot gases. The effort included corrosion data compilation from numerous industrial sources and data generation at Shell Oak Ridge National Laboratory and several other companies for selected conditions. These data were organized into groupings representing various combinations of commercially available alloys and corrosion by various mechanisms after acceptance via a critical screening process to ensure the data were for alloys and conditions, which were adequately well defined, and of sufficient repeatability. ASSET is the largest and most capable, publicly-available technology in the field of corrosion assessment and prediction for alloys corroding by high temperature processes in chemical plants, hydrogen production, energy conversion processes, petroleum refining, power generation, fuels production and pulp/paper processes. The problems addressed by ASSET are: determination of the likely dominant corrosion mechanism based upon information available to the chemical engineers designing and/or operating various processes and prediction of engineering metal losses and lifetimes of commercial alloys used to build structural components. These assessments consider exposure conditions (metal temperatures, gas compositions and pressures), alloy compositions and exposure times. Results of the assessments are determination of the likely dominant corrosion mechanism and prediction of the loss of metal/alloy thickness as a function of time, temperature, gas composition and gas pressure. The uses of these corrosion mechanism assessments and metal loss predictions are that the degradation of processing equipment can be managed for the first time in a way which supports efforts to reduce energy consumption, ensure structural integrity of equipment with the goals to avoid premature failure, to quantitatively manage corrosion over the entire life of high temperature process equipment, to select alloys for equipment and to assist in equipment maintenance programs. ASSET software operates on typical Windows-based (Trademark of Microsoft Corporation) personal computers using operating systems such as Windows 2000, Windows NT and Vista. The software is user friendly and contains the background information needed to make productive use of the software in various help-screens in the ASSET software. A graduate from a university-level curriculum producing a B.S. in mechanical/chemical/materials science/engineering, chemistry or physics typically possesses the background required to make appropriate use of ASSET technology. A training/orientation workshop, which requires about 3 hours of class time was developed and has been provided multiple times to various user groups of ASSET technology. Approximately 100 persons have been trained in use of the technology. ASSET technology is available to about 65 companies representing industries in petroleum/gas production and processing, metals/alloys production, power generation, and equipment design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

250 kWth Pilot Testing in Support of a 10 MWe Coal-Direct Chemical Looping Demonstration Feasibility Study

The Coal-Direct Chemical Looping (CDCL) process is emerging as a promising technology capable of high efficiency for producing electricity with low cost for carbon capture. In the CDCL process, coal is fully combusted to form carbon dioxide (CO2) and water via reaction with Fe2O3-based oxygen-carrier particles in a moving-bed reducer reactor. During reaction with coal, the Fe2O3 is reduced to form a mixture of Fe and FeO. The reduced particles are then transported to the combustor reactor where they are re-oxidized with air. The oxidation of the Fe and FeO mixture generates heat that can be used to produce steam for power generation. Once the particles are fully regenerated, they are pneumatically recycled to the reducer reactor where another reduction-oxidation (Redox) cycle begins. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been developing the CDCL technology based on iron-based metal oxide particles circulating in a moving-bed reducer coupled with an entrained-flow combustor. As part of a Phase I effort of a DOE-sponsored project, B&W identified scale-up technology gaps for the coal-direct chemical looping reactor process, most of which fall under the moving-bed reactor design and operation. However, after the Phase I research, B&W concluded that the CDCL technology has the potential of generating electricity while meeting the DOE goals of greater than 90% CO2 capture and less than 35% increase in levelized cost of electricity (LCOE). B&W then moved to a Phase II project to design, build and demonstrate the CDCL technology at a 250 kWth capacity. B&W finished the construction and commissioning of the pilot test facility in 2017. The approach used to design a 250 kWth pilot-scale CDCL facility to investigate the technology gaps is presented. Important lessons from the commissioning activities that would transfer to commercial plant start-up are also shared. The findings from the test program are being incorporated into a Pre-FEED study for a 10 MWe large pilot demonstration. Under a separately-funded heat integration project, B&W and OSU are developing a multiphase computational fluid dynamic model (MFIX) of the combustor to quantify heat transfer to embedded steam generation surface, utilizing pinch analysis (ASPEN Energy Analyzer) to identify potential improvements of the heat integration scheme, and developing an integrated dynamic model (ProTRAX) of the steam turbine coupled with the chemical looping process to identify potential start-up and transient operation issues. Under an advanced control system for optimizing operation, B&W is supporting OSU to install a rules-based optimizer (B&W’s FocalPoint) on their 25 kWt bench-scale facility on the OSU West Campus. Finally, B&W and OSU were recently selected to perform a Phase I Feasibility study to evaluate installation of the 10 MWe pilot at the Dover Power & Light Municipal Power Plant in Dover, Ohio. The feasibility study includes compiling an Environmental Information Volume and generating a cost estimate for the design, construction and commissioning of the plant as well as lining up commitments from potential project participants and funding contributors. Updates on each project will be presented. The status of the technology development will be discussed. We focus on the progress made to date towards closing the technology gaps under each project.

20 FOSSIL-FUELED POWER PLANTS↗

Update on Design of 10 MWe Iron-Based Coal Direct Chemical Looping Demonstration Plant

The Coal-Direct Chemical Looping (CDCL) process is emerging as a promising technology capable of high efficiency for producing electricity with low cost for carbon capture. In the CDCL process, coal is fully combusted to form carbon dioxide (CO2) and water via reaction with Fe2O3-based oxygen-carrier particles in a moving-bed reducer reactor. During reaction with coal, the Fe2O3 is reduced to form a mixture of Fe and FeO. The reduced particles are then transported to the combustor reactor where they are re-oxidized with air. The oxidation of the Fe and FeO mixture generates heat that can be used to produce steam for power generation. Once the particles are fully regenerated, they are pneumatically recycled to the reducer reactor where another reduction-oxidation (Redox) cycle begins. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been developing the CDCL technology based on iron-based metal oxide particles circulating in a moving-bed reducer coupled with an entrained-flow combustor. As part of a Phase I effort of a DOE-sponsored project, B&W identified scale-up technology gaps for the coal-direct chemical looping reactor process, most of which fall under the moving-bed reactor design and operation. However, after the Phase I research, B&W concluded that the CDCL technology has the potential of generating electricity while meeting the DOE goals of greater than 90% CO2 capture and less than 35% increase in levelized cost of electricity (LCOE). B&W then moved to a Phase II project to design, build and demonstrate the CDCL technology at a 250 kWth capacity. B&W finished the construction and commissioning of the pilot test facility in 2017. The approach used to design a 250 kWth pilot-scale CDCL facility to investigate the technology gaps is presented. Important lessons from the commissioning activities that would transfer to commercial plant start-up are also shared. The findings from the test program are being incorporated into a Pre-FEED study for a 10 MWe large pilot demonstration. Under a separately-funded heat integration project, B&W and OSU are developing a multiphase computational fluid dynamic model (MFIX) of the combustor to quantify heat transfer to embedded steam generation surface, utilizing pinch analysis (ASPEN Energy Analyzer) to identify potential improvements of the heat integration scheme, and developing an integrated dynamic model (ProTRAX) of the steam turbine coupled with the chemical looping process to identify potential start-up and transient operation issues. Under an advanced control system for optimizing operation, B&W is supporting OSU to install a rules-based optimizer (B&W’s FocalPoint) on their 25 kWt bench-scale facility on the OSU West Campus. Finally, B&W and OSU were recently selected to perform a Phase I Feasibility study to evaluate installation of the 10 MWe pilot at the Dover Power & Light Municipal Power Plant in Dover, Ohio. The feasibility study includes compiling an Environmental Information Volume and generating a cost estimate for the design, construction and commissioning of the plant as well as lining up commitments from potential project participants and funding contributors. Updates on each project will be presented. The status of the technology development will be discussed. We focus on the progress made to date towards closing the technology gaps under each project.

20 FOSSIL-FUELED POWER PLANTS↗

Approach to Low-Cost High-Efficiency OLED Lighting. Building Technologies Solid State Lighting (SSL) Program Final Report

This project developed an integrated substrate which organic light emitting diode (OLED) panel developers could employ the integrated substrate to fabricate OLED devices with performance and projected cost meeting the MYPP targets of the Solid State Lighting Program of the Department of Energy. The project optimized the composition and processing conditions of the integrated substrate for OLED light extraction efficiency and overall performance. The process was further developed for scale up to a low-cost process and fabrication of prototype samples. The encapsulation of flexible OLEDs based on this integrated substrate was also investigated using commercial flexible barrier films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flat H Frangible Joint Evolution

Space vehicle staging and separation events require pyrotechnic devices. They are single-use mechanisms that cannot be tested, nor can failure-tolerant performance be demonstrated in actual flight articles prior to flight use. This necessitates the implementation of a robust design and test approach coupled with a fully redundant, failure-tolerant explosive mechanism to ensure that the system functions even in the event of a single failure. Historically, NASA has followed the single failure-tolerant (SFT) design philosophy for all human-rated spacecraft, including the Space Shuttle Program. Following the end of this program, aerospace companies proposed building the next generation human-rated vehicles with off-the-shelf, non-redundant, zero-failure-tolerant (ZFT) separation systems. Currently, spacecraft and launch vehicle providers for both the Orion and Commercial Crew Programs (CCPs) plan to deviate from the heritage safety approach and NASA's SFT human rating requirements. Both programs' partners have base-lined ZFT frangible joints for vehicle staging and fairing separation. These joints are commercially available from pyrotechnic vendors. Non-human-rated missions have flown them numerous times. The joints are relatively easy to integrate structurally within the spacecraft. In addition, the separation event is debris free, and the resultant pyro shock is lower than that of other design solutions. It is, however, a serious deficiency to lack failure tolerance. When used for critical applications on human-rated vehicles, a single failure could potentially lead to loss of crew (LOC) or loss of mission (LOM)). The Engineering and Safety & Mission Assurance directorates within the NASA Johnson Space Center took action to address this safety issue by initiating a project to develop a fully redundant, SFT frangible joint design, known as the Flat H. Critical to the ability to retrofit on launch vehicles being developed, the SFT mechanisms must fit within the same three-dimensional envelope as current designs as well as meet structural loads requirements. There is increased mass associated with the redundant design, and the goal is to minimize the weight impact as much as possible. These requirements presented significant challenges, both technically and financially; these challenges will be explored in this paper. Perhaps greater than the technical issues confronted during this design process, were the financial considerations. These were a significant part of the story of this design and development plan. Insufficient financial and labor resources were formidable barriers to completing this project. Nevertheless, JSC personnel successfully conducted several test series at JSC with very useful results. The many lessons learned drove design improvements, performance efficiency, and increased functional reliability. This paper examines the significant technical and financial challenges that these requirements posed to the project team. It discusses the evolution of the SFT frangible joint design, including optimization, testing, and successful partnering of the Johnson Space Center (JSC) engineering and JSC safety organizations, to enhance the flight safety margin for America's next generation of human-rated space vehicles.

Diegelman, Thomas E.↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced control sequences and FDD technology. Just shiny objects, or ready for scale?

Innovations in commercial building control sequences (ASHRAE guideline 36) and fault detection and diagnostics (FDD) technology have the potential to transform existing building operational efficiency by realizing whole-building level savings on the order of 15% and higher. However, several technical and market barriers related to up-front estimation of achievable savings, verifying implementation, and ensuring persistence are slowing down their adoption as a core offering through diverse owner-funded initiatives and rate-payer funded programs. This paper describes a suite of solutions to overcome these barriers to program delivery of advanced HVAC controls integrated with FDD energy management and information system (EMIS) technology. First, the Guideline 36 conformance test offers an automated method to confirm correct sequence implementation by the manufacturer, before field deployment. A successful test of a controller was conducted using a new manufacturer-independent hardware-in-the-loop testbed demonstrating the viability and scalability of this approach. Second, the Guideline 36 energy savings calculator uses modeling paired with high-level user inputs to estimate building-specific savings potential, target cost effective implementation and minimize uncertainty. Initial results indicate the baseline control sequences significantly impact energy savings, however, as much as 50% savings may be possible for the worst-case baseline scenario. Third, a functional specification provides minimum recommended EMIS-FDD capabilities, and best practices to integrate the technology into organizational practice and ensure that advanced control sequences provide persistent savings.

Pritoni, Marco↗

Energy R&D portfolio analysis based on climate change mitigation

The diverse nature and uncertain potential of the energy technologies that are or may be available to mitigate greenhouse gas emissions pose a challenge to policymakers trying to invest public funds in an optimal R&D portfolio. This paper discusses two analytical approaches to this challenge used to inform funding decisions related to the U.S. Department of Energy (DOE) applied energy R&D portfolio. The two approaches are distinguished by the constraints under which they were conducted: the need to provide an end-to-end portfolio analysis as input to internal DOE budgeting processes, but with limited time and subject to institutional constraints regarding important issues such as expert judgment. Because of these constraints, neither approach should be viewed as an attempt to push forward the state of the art in portfolio analysis in the abstract. Instead, they are an attempt to use more stylized, heuristic methods that can provide first-order insights in the DOE institutional context. Both approaches make use of advanced technology scenarios implemented in an integrated assessment modeling framework and then apply expert judgment regarding the likelihood of achieving associated R&D and commercialization goals. The approaches differ in the granularity of the scenarios used and in the definition of the benefits of technological advance: in one approach the benefits are defined as the cumulative emission reduction attributable to a particular technology; in the other approach benefits are defined as the cumulative cost reduction. In both approaches a return on investment (ROI) criterion is established based on benefits divided by federal R&D investment. The ROI is then used to build a first-order approximation of an optimal applied energy R&D investment portfolio. Although these methodologies have been used to inform an actual budget request, the results reflect only one input among many used in budget formulation. The results are therefore not representative of an official U.S. government or DOE funding recommendation but should instead be considered illustrative of the way in which methodologies such as these could be applied.

Climate change↗

A Behavior Tree Approach for Battery-Aware Inspection of Large Structures Using Drones

Electric multi-rotor drones have been used to inspect several structures, including large buildings and dams. In these inspections, energy consumption is a concern. To prevent the drone from running out of battery, commercial drones usually come back to their home position when the battery level reaches a minimum threshold. The pilots then need to replace the battery and use their own experience to restart the inspection mission approximately from where it ended before the drone returned home. Instead of relying on the human operator, in this paper, we automate this process using behavior trees, which is an effective way to perform autonomous mission control and supervision. By integrating battery management strategies into a behavior tree framework, this paper demonstrates the drone’s adaptive and resilient decision-making when confronted with limited power constraints. We implemented our methodology using a commercial drone and tested the proposed ideas in a photogrammetry-based inspection task.

42 ENGINEERING↗

DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.

Hoon Lee, Sang↗

Building a Trusted Roaming Hub [Slides]

The Trusted Roaming Hub is a U.S. Department of Energy-backed initiative led by the National Laboratory of the Rockies (NLR) to address one of the most persistent challenges in electric vehicle (EV) charging: fragmented roaming, inconsistent interoperability, and insufficient digital trust across charging networks. As EV adoption accelerates and charging infrastructure scales nationwide, today's many-to-many integration model between eMobility Service Providers (eMSPs) and Charge Point Operators (CPOs) has become increasingly brittle, costly, and difficult to secure. The Trusted Roaming Hub introduces a neutral, cybersecurity-forward "switchboard" architecture that enables standardized, secure, and scalable roaming interactions across the EV charging ecosystem. Rather than replacing existing networks or commercial relationships, the hub acts as a trusted intermediary that enforces consistent identity, authentication, authorization, and routing across participants improving reliability for drivers, lowering integration burden for industry, and creating a foundation for future grid-interactive charging services. This read-ahead provides an overview of the problem the hub is designed to solve, the core functional and security concepts behind the architecture, the value proposition to key stakeholders, and the near-term trajectory of the work.

33 ADVANCED PROPULSION SYSTEMS↗

Comparative evaluation and selection of heat exchangers using multicriteria decision-making

Here, this study presents a well-structured method for comparing and selecting Heat Exchanger (HE) technologies for Integrated Energy Systems (IES). The decision to select a HE for a particular IES configuration can vary greatly depending not only on engineering requirements but also on customer’s specific demand. In other words, the HE selection for IES requires a multicriteria decision-making approach, taking into account diverse technical, economic, and safety aspects, as well as the relative priorities considered by energy users. This study employs a HE evaluation approach combining multicriteria decision-making techniques widely used in various industries: quality function deployment (QFD) and analytic hierarchy process (AHP) techniques. Of particular interest is the use of the proposed method to select a high-temperature HEs that couples advanced nuclear reactors and industrial processes. To build a practical basis for comparing HEs within the proposed framework, efforts were made to identify the various HEs requirements for IES purposes. In addition, leveraging the insights obtained from the literature review and the market survey of commercial HE suppliers, a knowledge base was built to facilitate the comparison of each requirement across various HE designs. Also, evaluation metrics were identified for HE requirements with robust rational to enhance the quality of decisions made throughout the proposed evaluation process. The evaluation procedure and knowledge base described in this study can provide a useful basis for those interested in screening the appropriate HE designs for various IES scenarios.

Analytic Hierarchy Process (AHP)↗

An Edge-Cloud Integrated Solution for Buildings Demand Response Using Reinforcement Learning

Buildings, as major energy consumers, can provide great untapped demand response (DR) resources for grid services. However, their participation remains low in real-life. One major impediment for popularizing DR in buildings is the lack of cost-effective automation systems that can be widely adopted. Existing optimization-based smart building control algorithms suffer from high costs on both building-specific modeling and on-demand computing resources. To tackle these issues, this paper proposes a cost-effective edge-cloud integrated solution using reinforcement learning (RL). Beside RL’s ability to solve sequential optimal decision-making problems, its adaptability to easy-to-obtain building models and the off-line learning feature are likely to reduce the controller’s implementation cost. Using a surrogate building model learned automatically from building operation data, an RL agent learns an optimal control policy on cloud infrastructure, and the policy is then distributed to edge devices for execution. Simulation results demonstrate the control efficacy and the learning efficiency in buildings of different sizes. A preliminary cost analysis on a 4-zone commercial building shows the annual cost for optimal policy training is only 2.25% of the DR incentive received. Results of this study show a possible approach with higher return on investment for buildings to participate in DR programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗