Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Conservation and Functional Importance of Carbon-Oxygen Hydrogen Bonding in AdoMet-Dependent Methyltransferases

S-Adenosylmethionine (AdoMet)-based methylation is integral to metabolism and signaling. AdoMet-dependent methyltransferases belong to multiple distinct classes and share a catalytic mechanism that arose through convergent evolution; however, fundamental determinants underlying this shared methyl transfer mechanism remain undefined. A survey of high-resolution crystal structures reveals that unconventional carbon–oxygen (CH···O) hydrogen bonds coordinate the AdoMet methyl group in different methyltransferases irrespective of their class, active site structure, or cofactor binding conformation. Corroborating these observations, quantum chemistry calculations demonstrate that these charged interactions formed by the AdoMet sulfonium cation are stronger than typical CH···O hydrogen bonds. Biochemical and structural studies using a model lysine methyltransferase and an active site mutant that abolishes CH···O hydrogen bonding to AdoMet illustrate that these interactions are important for high-affinity AdoMet binding and transition-state stabilization. Further, crystallographic and NMR dynamics experiments of the wild-type enzyme demonstrate that the CH···O hydrogen bonds constrain the motion of the AdoMet methyl group, potentially facilitating its alignment during catalysis. Collectively, the experimental findings with the model methyltransferase and structural survey imply that methyl CH···O hydrogen bonding represents a convergent evolutionary feature of AdoMet-dependent methyltransferases, mediating a universal mechanism for methyl transfer.

Horowitz, Scott↗

via machinae : Searching for stellar streams using unsupervised machine learning

ABSTRACT We develop a new machine learning algorithm, via machinae, to identify cold stellar streams in data from the Gaia telescope. via machinae is based on ANODE, a general method that uses conditional density estimation and sideband interpolation to detect local overdensities in the data in a model agnostic way. By applying ANODE to the positions, proper motions, and photometry of stars observed by Gaia, via machinae obtains a collection of those stars deemed most likely to belong to a stellar stream. We further apply an automated line-finding method based on the Hough transform to search for line-like features in patches of the sky. In this paper, we describe the via machinae algorithm in detail and demonstrate our approach on the prominent stream GD-1. Though some parts of the algorithm are tuned to increase sensitivity to cold streams, the via machinae technique itself does not rely on astrophysical assumptions, such as the potential of the Milky Way or stellar isochrones. This flexibility suggests that it may have further applications in identifying other anomalous structures within the Gaia data set, for example debris flow and globular clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗

Determination of plasma density from data on the ion current to cylindrical and planar probes

To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models were used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response induction coil magnetometers to perturbations in orientation

© 1996-2018 Society of Exploration Geophysicists. All rights reserved. We explore the data collected by a 3-component induction coil magnetometer system with respect to motion of the instruments in earths static magnetic field. The sensitivtiy of the inductiuon coil magnetometer leads to unprecediented accuracy on tilt measurements. We model the signals observed during seismic events as being perturbations in coil orientation. In theory, these perturbations can include ground roll, ocean motion, nearby cultural seismicity, or any other field with a tilting effect. Using data from a magnetic observatory near Parkfield CA we invert several time series of coil data during different levels of seismic activity in an attempt to determine the magnitudes of rotation at which our model accurately describes the coil data. Finally, we explore the transfer function between the coils and nearby seismic instruments (accelerometers, tiltmeters, and velocity seismometers).

Kappler, K↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Real-Time Dynamic Brake Assessment for Heavy Commercial Vehicle Safety

This paper summarizes initial results and findings of a model developed to determine the braking performance of commercial motor vehicles in motion regardless of brake type or gross weight. Real-world data collected by Oak Ridge National Laboratory for a U.S. Department of Energy study was used to validate the model. Expanding on previous proof-of-concept research showing the linear relationship of brake application pressure and deceleration additional parameters such as elevation were added to the model. Outputs from the model consist of coefficients calculated for every constant pressure braking event from a vehicle that can be used to calculate a deceleration and thus compute a stopping distance for a given scenario. Using brake application pressure profiles derived from the dataset, stopping distances for light and heavy loads of the same vehicle were compared for various speed and road grades. For a constant brake application pressure profile (i.e. the pressure is relatively constant throughout the entire stop) it was shown that the lighter vehicle was able to stop in a shorter distance than the heavier vehicle in most scenarios other than large uphill grades. Significant changes in weight can be observed through the fuel efficiency of the vehicle to determine if the model needs to be calibrated with new or additional braking events. The model was initially developed for tracking brake performance to inform routine maintenance and the ordering of vehicles in a platoon but can be expanded to other connected and automated research areas.

Siekmann, Adam↗

Effects of static equilibrium and higher-order nonlinearities on rotor blade stability in hover

The equilibrium and stability of the coupled elastic lead/lag, flap, and torsion motion of a cantilever rotor blade in hover are addressed, and the influence of several higher-order terms in the equations of motion of the blade is determined for a range of values of collective pitch. The blade is assumed to be untwisted and to have uniform properties along its span. In addition, chordwise offsets between its elastic, tension, mass, and aerodynamic centers are assumed to be negligible for simplicity. The aerodynamic forces acting on the blade are modeled using a quasi-steady, strip-theory approximation.

Crespodasilva, Marcelo R. M.↗

High-voltage plasma interactions calculations using NASCAP/LEO

This paper reviews four previous simulations (two laboratory and two space-flight) of interactions of a high-voltage spacecraft with a plasma under low-earth orbit conditions, performed using a three-dimensional computer code NASCAP/LEO. Results show that NASCAP/LEO can perform meaningful simulations of high-voltage plasma interactions taking into account three-dimensional effects of geometry, spacecraft motion, and magnetic field. Two new calculations are presented: (1) for current collection by 1-mm pinholes in wires (showing that a pinhole in a wire can collect far more current than a similar pinhole in a flat plate); and (2) current collection by Charge-2 mother vehicle launched in December 1985. It is shown that the Charge-2 calculations predicted successfully ion collection at negative bias, the floating potential of a probe outside or inside the sheath under negative bias conditions, and magnetically limited electron collection under electron beam operation at high altitude.

Mandell, M. J.↗

Population Pharmacokinetics of Intranasal Scopolamine

Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS).The bioavailability and pharmacokinetics (PK) was evaluated using data collected in Phase II IND protocols. We reported earlier statistically significant gender differences in PK parameters of INSCOP at a dose level of 0.4 mg. To identify covariates that influence PK parameters of INSCOP, we examined population covariates of INSCOP PK model for 0.4 mg dose. Methods: Plasma scopolamine concentrations versus time data were collected from 20 normal healthy human subjects (11 male/9 female) after a 0.4 mg dose. Phoenix NLME was employed for PK analysis of these data using gender, body weight and age as covariates for model selection. Model selection was based on a likelihood ratio test on the difference of criteria (-2LL). Statistical significance for base model building and individual covariate analysis was set at P less than 0.05{delta(-2LL)=3.84}. Results: A one-compartment pharmacokinetic model with first-order elimination best described INSCOP concentration ]time profiles. Inclusion of gender, body weight and age as covariates individually significantly reduced -2LL by the cut-off value of 3.84(P less than 0.05) when tested against the base model. After the forward stepwise selection and backward elimination steps, gender was selected to add to the final model which had significant influence on absorption rate constant (ka) and the volume of distribution (V) of INSCOP. Conclusion: A population pharmacokinetic model for INSCOP has been identified and gender was a significant contributing covariate for the final model. The volume of distribution and Ka were significantly higher in males than in females which confirm gender-dependent pharmacokinetics of scopolamine after administration of a 0.4 mg dose.

Wu, L.↗

Human Factors Applications of Biomechanical Modeling

Biomechanical data collection and modeling has applications to the field of human factors. Specifically, motion data can be used to determine the operational volume necessary for performing a task. The operational volume assessment can be performed in order to determine how much volume is needed to perform the task or if task performance can be contained and adequately performed within an allocated volume. Motion and external force data, along with computational modeling techniques, can be used to estimate the internal loading produced during performance of a task. Internal loading estimates can be used to determine if an adequate stimulus is generated for maintenance of musculoskeletal health and also for comparison to injury thresholds to determine injury risk during task performance.

Lewandowski, Beth↗

Building and Calibration of a FAST Model of the SWAY Prototype Floating Wind Turbine: Preprint

Present efforts to verify and validate aero-hydro-servo-elastic numerical simulation tools that predict the dynamic response of a floating offshore wind turbine are primarily limited to code-to-code comparisons or code-to-data comparisons using data from wind-wave basin tests. In partnership with SWAY AS, the National Renewable Energy Laboratory (NREL) installed scientific wind, wave, and motion measurement equipment on the 1/6.5th-scale prototype SWAY floating wind system to collect data to validate a FAST model of the SWAY design in an open-water condition. Nanyang Technological University (NTU), through a collaboration with NREL, assisted in this validation.

17 WIND ENERGY↗

Large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading

Highlights: • A large centrifuge model of a geomembrane-lined landfill was seismically loaded. • The scaled peak acceleration of the strongest input motion was 0.6 g. • Laboratory testing was conducted to obtain properties of the model materials. • Collected data included liner strains due to downdrag and seismic loading. • Results show that settlement and seismic loading can potentially damage geomembranes. • Results can be used to validate numerical models for geomembrane performance. •The laboratory and centrifuge testing data is publicly available. - Abstract: A large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading was conducted to help validate a numerical model for performance based design of geomembrane liner systems. The test was conducted using the 240 g-ton centrifuge at the University of California at Davis under the U.S. National Science Foundation Network for Earthquake Engineering Simulation Research (NEESR) program. A 0.05 mm thin film membrane was used to model the liner. The waste was modeled using a peat-sand mixture. The side slope membrane was underlain by lubricated low density polyethylene to maximize the difference between the interface shear strength on the top and bottom of the geomembrane and the induced tension in it. Instrumentation included thin film strain gages to monitor geomembrane strains and accelerometers to monitor seismic excitation. The model was subjected to an input design motion intended to simulate strong ground motion from the 1994 Hyogo-ken Nanbu earthquake. Results indicate that downdrag waste settlement and seismic loading together, and possibly each phenomenon individually, can induce potentially damaging tensile strains in geomembrane liners. The data collected from this test is publically available and can be used to validate numerical models for the performance of geomembrane liner systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward an IMU-based Space Suit Motion Capture System

Spacesuits are complex engineering systems that sustain human health and enable performance outside of Earth-like environments. These systems must support human mobility and physical workload demands while minimizing injury risk during extravehicular activity (EVA). Future EVA on the lunar surface during the Artemis program is expected to be more frequent and require higher physical workloads than previous EVAs during the ISS, Shuttle, or Apollo programs. Hence it is important to optimize future as well as current spacesuits to be efficient and comfortable for the success of space and planetary missions. To enable this, an efficient method is needed to test these spacesuits on the ground.When testing spacesuits in ground environments, it is often necessary to understand the kinematics of the suit to validate the design against relevant requirements or characterize the physical workload necessary to operate the suit. This is a challenging task for traditional optical motion capture (OMC) approaches: suit-mounted OMC markers are easily occluded by the subject or environment and may become detached during testing. Controlling lighting and reflectivity of objects in the motion capture volume is also difficult. Fixed-position OMC cameras also constrain testing to a small and contrived laboratory environment, disallowing kinematics capture in field environments.One promising alternative is the use of suit-mounted inertial measurement units (IMUs). These sensors are small, unobtrusive, and portable, but come at the cost of increased sensor noise and complexity of the software and mathematics to analyze the collected data. To this end, engineers at NASA are developing the Augmented Suit Inverse Kinematics (ASIK) system, a complete motion capture methodand inverse kinematics solver which relies solely on a network of wireless IMUs attached to the major kinematic segments of the spacesuit. The ASIK modeling language allows for the simple inclusion of probabilistic priors such as suit size and shape or IMU positions and rotations. Furthermore, to increase accuracy and reduce operational overhead to use this motion capture approach, the developed inverse kinematics solver exploits so-called self-calibratingalgorithmic techniques, which reduce the need for precise alignment of the sensors on the segments or scripted functional calibration procedures. The ASIK system was tested in a 7-subject pilot study. Each subject donned NASA’s new prototype exploration spacesuit in the Active Response Gravity Offload System (ARGOS) facility at the NASA Johnson Space Center. The subjects were outfitted with a set of 14 APDM (Portland, OR, USA) Opal IMUs, 12 of which were used in the ASIK model to estimate lower body and trunk kinematics. The subjects were also outfitted with a set of reflective OMC markers and traditional OMC data was collected and processed. Presented results will include characterization of ASIK-derived suit joint angles accuracy against an optical motion capture datum. Discussion of these results, as well as discussion of system calibration and nuances of mathematical observability, will be included.If successful, IMU-based motion capture will enable testing and validation of spacesuits more frequently, with less overhead, in more extreme environments. Future work will apply these techniques to common spacesuit testing tasks, such as gait, mobility, and balance assessment, physical workload characterization, and ergonomics evaluations.

Timothy Mcgrath↗

Evaluation of simulation motion fidelity criteria in the vertical and directional axes

An evaluation of existing motion fidelity criteria was conducted on the NASA Ames Vertical Motion Simulator. Experienced test pilots flew single-axis repositioning tasks in both the vertical and the directional axes. Using a first-order approximation of a hovering helicopter, tasks were flown with variations only in the filters that attenuate the commands to the simulator motion system. These filters had second-order high-pass characteristics, and the variations were made in the filter gain and natural frequency. The variations spanned motion response characteristics from nearly full math-model motion to fixed-base. Between configurations, pilots recalibrated their motion response perception by flying the task with full motion. Pilots subjectively rated the motion fidelity of subsequent configurations relative to this full motion case, which was considered the standard for comparison. The results suggested that the existing vertical-axis criterion was accurate for combinations of gain and natural frequency changes. However, if only the gain or the natural frequency was changed, the rated motion fidelity was better than the criterion predicted. In the vertical axis, the objective and subjective results indicated that a larger gain reduction was tolerated than the existing criterion allowed. The limited data collected in the yaw axis revealed that pilots had difficulty in distinguishing among the variations in the pure yaw motion cues.

Schroeder, Jeffery A.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Phase control of nonlinear Breit-Wheeler pair creation

Electron-positron pair creation occurs throughout the universe in the environments of extreme astrophysical objects, such as pulsar magnetospheres and black hole accretion disks. The difficulty of emulating these environments in the laboratory has motivated the use of ultrahigh-intensity laser pulses for pair creation. Here we show that the phase offset between a laser pulse and its second harmonic can be used to control the relative transverse motion of electrons and positrons created in the nonlinear Breit-Wheeler process. Analytic theory and particle-in-cell simulations of a head-on collision between a two-color laser pulse and electron beam predict that with an appropriate phase offset, the electrons will drift in one direction and the positrons in the other. The resulting current may provide a collective signature of nonlinear Breit-Wheeler, while the spatial separation resulting from the relative motion may facilitate isolation of positrons for subsequent applications or detection. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗