Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cleaned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Cleaning graphene: A first quantum/classical molecular dynamics approach

Graphene outstanding properties created a huge interest in the condensed matter community and unprecedented fundings at the international scale in the hope of application developments. Recently, there have been several reports of incomplete removal of the polymer resists used to transfer as-grown graphene from one substrate to another, resulting in altered graphene transport properties. Finding a large-scale solution to clean graphene from adsorbed residues is highly desirable and one promising possibility would be to use hydrogen plasmas. In this spirit, we couple here quantum and classical molecular dynamics simulations to explore the kinetic energy ranges required by atomic hydrogen to selectively etch a simple residue—a CH{sub 3} group—without irreversibly damaging the graphene. For incident energies in the 2–15 eV range, the CH{sub 3} radical can be etched by forming a volatile CH{sub 4} compound which leaves the surface, either in the CH{sub 4} form or breaking into CH{sub 3} + H fragments, without further defect formation. At this energy, adsorption of H atoms on graphene is possible and further annealing will be required to recover pristine graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pollution inequality 50 years after the Clean Air Act: the need for hyperlocal data and action

Fifty years ago the Clean Air Act amendments of 1970 were the first major US legislation that authorized regulation of air pollutants, creating National Ambient Air Quality Standards (NAAQSs) to protect public health and the environment. While US air quality has improved, with average PM 2.5 concentrations in 2016 a third of 1981 levels, air pollution remains a major health risk in the US and globally. Moreover, air pollution impacts are still uneven, with the most polluted US communities of 50 years ago still so today. Air pollution “hot spots” result in disproportionate exposure at neighborhood scales within cities, particularly in disadvantaged communities, but an in-depth understanding at these scales is lacking. This policy perspective discusses how trends in sensor technology, spatial data collection, analytics and retrieval are converging to enable the production of hyperlocal air pollution data, and that this needs to be done in a manner that enables marginalized communities to shape decision making.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen as Part of a 100% Clean Energy System: Exploring Its Decarbonization Roles

Today's energy system uses a variety of fuels and energy carriers in molecular forms, such as coal, oil, and natural gas, each contributing to CO2 emissions (Figure 1). As solar and wind levels grow and the energy system becomes more electrified, fossil molecular fuels will contribute a progressively smaller fraction of overall energy. As shown in Figure 2, hydroelectric storage and molecules, such as coal and natural gas, provide substantial storage and dispatch functionality today that will become increasingly critical for electricity operation and stability. Emerging low-carbon gases, such as hydrogen, can support the efficient integration of renewables in the transition from today's energy system to one that is 100% clean from a carbon emissions perspective.

clean energy system↗

Tracking electron-induced carbon contamination and cleaning of Ru surfaces by Auger electron spectroscopy

Extreme ultraviolet (EUV) radiation induced growth of carbon and oxygen desorption were investigated on a Ru surface by Auger electron spectroscopy (AES) in the presence and absence of additional photoelectrons (PEs) from a focusing Ru mirror. A decrease in EUV reflectivity with carbon growth in the presence of additional PEs has been observed. Conversely, a carbonaceous Ru surface was cleaned in sequential AES, and discussed in terms of secondary electron assisted dissociation of residual hydrocarbons and water molecules, followed by a chemical reaction between adsorbed carbon and oxygen atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser space debris cleaning: elimination of detrimental self-focusing effects

A ground-based laser system for space debris cleaning requires pulse power well above the critical power for self-focusing in the atmosphere. Self-focusing results in beam quality degradation and is detrimental for the system operation. We demonstrate that, for the relevant laser parameters, when the thickness of the atmosphere is much less than the focusing length (that is, of the orbit scale), the beam transit through the atmosphere produces the phase distortion only. The model thus developed is in very good agreement with numerical modeling. This implies that, by using phase mask or adaptive optics, it may be possible to eliminate almost completely the impact of self-focusing effects in the atmosphere on the laser beam propagation.

47 OTHER INSTRUMENTATION↗

Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10{sup 7} W/cm{sup 2}. The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of Qualitative and Quantitative Parameters of Air Cleaning by a Pulsed Corona Discharge Using Multicomponent Standard Mixtures

The efficiency of removal of volatile organic impurities in air by a pulsed corona discharge is investigated using model mixtures. Based on the method of competing reactions, an approach to estimating the qualitative and quantitative parameters of the employed electrophysical technique is proposed. The concept of the “toluene coefficient” characterizing the relative reactivity of a component as compared to toluene is introduced. It is proposed that the energy efficiency of the electrophysical method be estimated using the concept of diversified yield of the removal process. Such an approach makes it possible to substantially intensify the determination of energy parameters of removal of impurities and can also serve as a criterion for estimating the effectiveness of various methods in which a nonequilibrium plasma is used for air cleaning from volatile impurities.

54 ENVIRONMENTAL SCIENCES↗

Southeast Regional Clean Energy Policy Analysis (Revised)

More than half of the electricity produced in the southeastern states is fuelled by coal. Although the region produces some coal, most of the states depend heavily on coal imports. Many of the region's aging coal power facilities are planned for retirement within the next 20 years. However, estimates indicate that a 20% increase in capacity is needed over that time to meet the rapidly growingdemand. The most common incentives for energy efficiency in the Southeast are loans and rebates; however, total public spending on energy efficiency is limited. The most common state-level policies to support renewable energy development are personal and corporate tax incentives and loans. The region produced 1.8% of the electricity from renewable resources other than conventionalhydroelectricity in 2009, half of the national average. There is significant potential for development of a biomass market in the region, as well as use of local wind, solar, methane-to-energy, small hydro, and combined heat and power resources. Options are offered for expanding and strengthening state-level policies such as decoupling, integrated resource planning, building codes, net metering,and interconnection standards to support further clean energy development. Benefits would include energy security, job creation, insurance against price fluctuations, increased value of marginal lands, and local and global environmental paybacks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Cities 2011 Vehicle Buyer's Guide

The 2011 Clean Cities Light-Duty Vehicle Buyer's Guide is a consumer publication that provides a comprehensive list of commercially available alternative fuel and advanced vehicles in model year 2011. The guide allows for side-by-side comparisons of fuel economy, price, emissions, and vehicle specifications.

09 BIOMASS FUELS↗

What is Clean Cities? (Brochure)

Fact sheet describes the Clean Cities program and includes the contact information for its 87 coalitions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic Impacts from the Boulder County, Colorado, ClimateSmart Loan Program: Using Property-Assessed Clean Energy (PACE) Financing

This report examines the economic impacts (including job creation) from the Boulder County, Colorado, ClimateSmart Loan Program (CSLP), an example of Property-Assessed Clean Energy (PACE) financing. The CSLP was the first test of PACE financing on a multi-jurisdictional level (involving individual cities as well as the county government). It was also the first PACE program to comprehensivelyaddress energy efficiency measures and renewable energy, and it was the first funded by a public offering of both taxable and tax-exempt bonds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

USVI Energy Road Map: Charting the Course to a Clean Energy Future (Brochure)

This brochure provides an overview of the integrated clean energy deployment process and progress of the Energy Development in Island Nations U.S. Virgin Islands pilot project road map, including over-arching goals, organization, strategy, technology-specific goals and accomplishments, challenges, solutions, and upcoming milestones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TREATMENT TANK CORROSION STUDIES FOR THE ENHANCED CHEMICAL CLEANING PROCESS

Radioactive waste is stored in high level waste tanks on the Savannah River Site (SRS). Savannah River Remediation (SRR) is aggressively seeking to close the non-compliant Type I and II waste tanks. The removal of sludge (i.e., metal oxide) heels from the tank is the final stage in the waste removal process. The Enhanced Chemical Cleaning (ECC) process is being developed and investigated by SRR to aid in Savannah River Site (SRS) High-Level Waste (HLW) as an option for sludge heel removal. Corrosion rate data for carbon steel exposed to the ECC treatment tank environment was obtained to evaluate the degree of corrosion that occurs. These tests were also designed to determine the effect of various environmental variables such as temperature, agitation and sludge slurry type on the corrosion behavior of carbon steel. Coupon tests were performed to estimate the corrosion rate during the ECC process, as well as determine any susceptibility to localized corrosion. Electrochemical studies were performed to develop a better understanding of the corrosion mechanism. The tests were performed in 1 wt.% and 2.5 wt.% oxalic acid with HM and PUREX sludge simulants. The following results and conclusions were made based on this testing: (1) In 1 wt.% oxalic acid with a sludge simulant, carbon steel corroded at a rate of less than 25 mpy within the temperature and agitation levels of the test. No susceptibility to localized corrosion was observed. (2) In 2.5 wt.% oxalic acid with a sludge simulant, the carbon steel corrosion rates ranged between 15 and 88 mpy. The most severe corrosion was observed at 75 C in the HM/2.5 wt.% oxalic acid simulant. Pitting and general corrosion increased with the agitation level at this condition. No pitting and lower general corrosion rates were observed with the PUREX/2.5 wt.% oxalic acid simulant. The electrochemical and coupon tests both indicated that carbon steel is more susceptible to localized corrosion in the HM/oxalic acid environment than in the PUREX/oxalic acid environment. (3) The corrosion rates for PUREX/8 wt.% oxalic acid were greater than or equal to those observed for the PUREX/2.5 wt.% oxalic acid. No localized corrosion was observed in the tests with the 8 wt.% oxalic acid. Testing with HM/8 wt.% oxalic acid simulant was not performed. Thus, a comparison with the results with 2.5 wt.% oxalic acid, where the corrosion rate was 88 mpy and localized corrosion was observed at 75 C, cannot be made. (4) The corrosion rates in 1 and 2.5 wt.% oxalic acid solutions were temperature dependent: (a) At 50 C, the corrosion rates ranged between 90 to 140 mpy over the 30 day test period. The corrosion rates were higher under stagnant conditions. (b) At 75 C, the initial corrosion rates were as high as 300 mpy during the first day of exposure. The corrosion rates increased with agitation. However, once the passive ferrous oxalate film formed, the corrosion rate decreased dramatically to less than 20 mpy over the 30 day test period. This rate was independent of agitation. (5) Electrochemical testing indicated that for oxalic acid/sludge simulant mixtures the cathodic reaction has transport controlled reaction kinetics. The literature suggests that the dissolution of the sludge produces a di-oxalatoferrate ion that is reduced at the cathodic sites. The cathodic reaction does not appear to involve hydrogen evolution. On the other hand, electrochemical tests demonstrated that the cathodic reaction for corrosion of carbon steel in pure oxalic acid involves hydrogen evolution. (6) Agitation of the oxalic acid/sludge simulant mixtures typically resulted in a higher corrosion rates for both acid concentrations. The transport of the ferrous ion away from the metal surface results in a less protective ferrous oxalate film. (7) A mercury containing species along with aluminum, silicon and iron oxides was observed on the interior of the pits formed in the HM/2.5 wt.% oxalic acid simulant at 75 C. The pitting rates in the agitated and non-agitated solution were 2 mils/day and 1 mil/day, respectively. A mechanism by which the mercury interacts with the aluminum and silicon oxides in this simulant to accelerate corrosion was proposed.

08 HYDROGEN↗

DEPOSITION TANK CORROSION TESTING FOR ENHANCED CHEMICAL CLEANING POST OXALIC ACID DESTRUCTION

An Enhanced Chemical Cleaning (ECC) process is being developed to aid in the high level waste tank closure at the Savannah River Site. The ECC process uses an advanced oxidation process (AOP) to destroy the oxalic acid that is used to remove residual sludge from a waste tank prior to closure. The AOP process treats the dissolved sludge with ozone to decompose the oxalic acid through reactions with hydroxyl radicals. The effluent from this oxalic acid decomposition is to be sent to a Type III waste tank and may be corrosive to these tanks. As part of the hazardous simulant testing that was conducted at the ECC vendor location, corrosion testing was conducted to determine the general corrosion rate for the deposition tank and to assess the susceptibility to localized corrosion, especially pitting. Both of these factors impact the calculation of hydrogen gas generation and the structural integrity of the tanks, which are considered safety class functions. The testing consisted of immersion and electrochemical testing of A537 carbon steel, the material of construction of Type III tanks, and 304L stainless steel, the material of construction for transfer piping. Tests were conducted in solutions removed from the destruction loop of the prototype ECC set up. Hazardous simulants, which were manufactured at SRNL, were used as representative sludges for F-area and H-area waste tanks. Oxalic acid concentrations of 1 and 2.5% were used to dissolve the sludge as a feed to the ECC process. Test solutions included the uninhibited effluent, as well as the effluent treated for corrosion control. The corrosion control options included mixing with an inhibited supernate and the addition of hydroxide. Evaporation of the uninhibited effluent was also tested since it may have a positive impact on reducing corrosion. All corrosion testing was conducted at 50 C. The uninhibited effluent was found to increase the corrosion rate by an order of magnitude from less than 1 mil per year (mpy) for an inhibited waste to a range of 5 to 23.4 mpy, depending on sludge chemistry. F-area-based effluents were, in general, more corrosive. Effective corrosion control measures included evaporation, hydroxide additions and mixing with supernates containing a representative supernate chemistry (5 M hydroxide and 1.5 M nitrite). Corrosion rates with these measures were generally 0.2 mpy. The A537 carbon steel was found to be susceptible to pitting when the corrosion control measure involved mixing the ECC effluent with a supernate chemistry having minimal inhibitor concentrations (0.5 M hydroxide and 0.3 M nitrite). Corrosion rates in this case were near 1 mpy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗