Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing a Commercial Buildings Energy Data Framework for India: A Comprehensive Look at Data Collection Approaches, Use Cases and Institutions

Enhancing energy efficiency of the commercial building stock is an important aspect of any national energy policy. Understanding how buildings use energy is critical to formulating any new policy that may impact energy use, underscoring the importance of credible data. Data enables informed decision making and good quality data is essential for policy makers to prioritize energy saving strategies and track implementation. Given the uniqueness of the buildings sector and challenges to collecting relevant energy data, this study characterizes various elements involved in pertinent data collection and management, with the specific focus on well-defined data requirements, appropriate methodologies and processes, feasible data collection mechanisms, and approaches to institutionalizing the collection process. This report starts with a comprehensive review of available examples of energy data collection frameworks for buildings across different countries. The review covers the U.S. experience in the commercial buildings sector, the European experience in the buildings sector and other data collection initiatives in Singapore and China to capture the more systematic efforts in Asia in the commercial sector. To provide context, the review includes a summary and status of disparate efforts in India to collect and use commercial building energy data. Using this review as a key input, the study developed a data collection framework for India with specific consideration to relevant use cases. Continuing with the framework for data collection, this study outlines the key performance indicators applicable to the use cases and their collection feasibility, as well as immediate priorities of the participating stakeholders. It also discusses potential considerations for data collection and the possible approaches for survey design. With the specific purpose of laying out the possible ways to structure and organize data collection institutionally, the study collates existing mechanisms to analyze building energy performance in India and opportunities for standardizing data collection. This report describes the existing capacities and resources for establishing an institutional framework for data collection, the legislation and mandates that support such activity, and identifies roles and responsibilities of the relevant ministries and organizations. Finally, the study presents conclusions and identifies two major data collection strategies within the existing legal framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced control for ground source heat pump systems

Ground source heat pumps (GSHP), also known as geothermal heat pumps (GHP), are proven advanced HVAC systems that utilize clean and renewable geothermal energy, as well as the massive thermal storage capacity of the ground, to provide space conditioning and water heating for both residential and commercial buildings. GSHPs have higher energy efficiencies than conventional HVAC systems. It is estimated, if GSHPs achieve a 10% market share in the US, in each year, 0.6 Quad Btu primary energy consumption can be saved and 36 million tons carbon emissions can be avoided (Liu et al. 2017). However, the current market share of GSHPs is less than 1%. The foremost barrier preventing wider adoption of GSHPs is their high installation costs. To enable wider adoption of GSHPs, the costeffectiveness of GSHP applications must be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perspectives on West Africa Ebola Virus Disease Outbreak, 2013-2016

The variety of factors that contributed to the initial undetected spread of Ebola virus disease in West Africa during 2013-2016 and the difficulty controlling the outbreak once the etiology was identified highlight priorities for disease prevention, detection, and response. These factors include occurrence in a region recovering from civil instability and lacking experience with Ebola response; inadequate surveillance, recognition of suspected cases, and Ebola diagnosis; mobile populations and extensive urban transmission; and the community's insufficient general understanding about the disease. The magnitude of the outbreak was not attributable to a substantial change of the virus. Finally, continued efforts during the outbreak and in preparation for future outbreak response should involve identifying the reservoir, improving in-country detection and response capacity, conducting survivor studies and supporting survivors, engaging in culturally appropriate public education and risk communication, building productive interagency relationships, and continuing support for basic research.

59 BASIC BIOLOGICAL SCIENCES↗

Utilization of municipal solid waste incineration fly ash for sulfoaluminate cement clinker production

Highlights: > The replacement can be taken up to 30% of MSWI fly ash in the raw mix. > The novelty compositional parameters were defined, their optimum values were determined. > Expansive property of SAC is strongly depended on gypsum content. > Three leaching test methods are used to assess the environmental impact. - Abstract: The feasibility of partially substituting raw materials with municipal solid waste incineration (MSWI) fly ash in sulfoaluminate cement (SAC) clinker production was investigated by X-ray diffraction (XRD), compressive strength and free expansion ratio testing. Three different leaching tests were used to assess the environmental impact of the produced material. Experimental results show that the replacement of MSWI fly ash could be taken up to 30% in the raw mixes. The good quality SAC clinkers are obtained by controlling the compositional parameters at alkalinity modulus (C{sub m}) around 1.05, alumina-sulfur ratio (P) around 2.5, alumina-silica ratio (N) around 2.0{approx}3.0 and firing the raw mixes at 1250 deg. C for 2 h. The compressive strengths of SAC are high in early age while that develop slowly in later age. Results also show that the expansive properties of SAC are strongly depended on the gypsum content. Leaching studies of toxic elements in the hydrated SAC-based system reveal that all the investigated elements are well bounded in the clinker minerals or immobilized by the hydration products. Although some limited positive results indicate that the SAC prepared from MSWI fly ash would present no immediate thread to the environment, the long-term toxicity leaching behavior needs to be further studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collaborative Research Programme in Decommissioning, Immobilisation and Storage Solutions for Nuclear Waste Inventories (DISTINCTIVE) - 16466

The UK government remains committed to nuclear power as an important part of the energy generation capacity over the next 30-50 years and possibly beyond, with aspirations for both new-build power stations and lifetime extension of the existing fleet. A central component of public acceptance for any new-build programme is the need to demonstrate our ability to safely manage and dispose of high- and intermediate-level wastes from legacy nuclear operations. Clear milestones associated with the needs of waste management and decommissioning have been provided by the UK government, and most rely on further research and technical developments being delivered over the next 10-20 years. The DISTINCTIVE (Decommissioning, Immobilisation and Storage Solutions for Nuclear Waste Inventories) consortium is carrying out research that addresses the broad area of nuclear waste and decommissioning, bringing together key industry partners and leading academic researchers from 10 of the UK's leading research intensive universities. The research being carried out is multi-disciplinary and covers both fundamental and applied topics, with research projects clustered in four major themes: AGR, Magnox and exotic spent fuels; PuO{sub 2} and fuel residues; legacy ponds and silo wastes; and structural integrity. The consortium builds upon and consolidates the work of previous Research Councils' UK Energy Programme-funded projects in the same field although, importantly, this new project draws in researchers from a larger group of universities and increases the multi-disciplinary nature of the group. All participating research groups have a strong track-record of supporting the nuclear industry through basic and applied research as well as consultancy activities. Key aims of the consortium are to extend and develop a relevant academic skill base in the UK associated with the needs of the nuclear waste management industry, to train the next generation of UK researchers, equipping them with skills and experiences relevant to nuclear waste management and decommissioning issues, and to carry out cutting-edge research that has the potential to provide new and innovative pathways to better management of both legacy and future nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

High Density Thermal Energy Storage by Highly Stable Glauber’s Salt Composites with Low Supercooling for Building-Scale Application

Phase change materials (PCM) are a promising candidate for thermal energy storage in building infrastructure, enabling grid-integrated peak load shaving by utilizing energy production in off-peak hours. Glauber’s salt (Na2SO4.10H2O, Sodium sulfate hydrate) are highly attractive due to their high energy storage capacity and low cost but Glauber’s salt suffers from long-standing challenges including high supercooling ( > 15oC) and low thermal cyclic stability, which is a major setback for practical building-scale energy storage applications. Here, we developed a unique ionic molecular nucleating agent for Glauber’s salt which reduced the supercooling temperature to less than 5oC. By combining this nucleated SSD with a polymer, phase segregation of salt hydrate for over 100 thermal cycles without degradation was achieved. Key was that the polymer confined the SSD crystals, preventing phase separation. In addition, we applied our stable Glauber’s salt composite in a miniatured building model and demonstrate that our PCM composite can be utilized for real-world building infrastructure.

additives↗

Montana Community-Scale Solar Strategy Project (Final Technical Report)

Grid-tied solar photovoltaic (PV) development began gradually in Montana, initially taking root in the early 2000s, largely in the form of small residential systems, rarely larger than two kilowatts. Utility support for solar technology through public benefit funding triggered the installation of the state’s first solar PV installations on community-owned facilities including schools, libraries, fire stations and local government buildings in the mid-2000s. By 2016, solar PV installations totaled approximately 28 megawatts of installed capacity, generating less than 0.05% of electricity sold in Montana. Montana’s solar fleet in 2016 included 17 megawatts of utility-scale solar farms, and three shared solar projects developed by rural electric cooperatives that ranged from 25 to 50 kilowatts in size. However, with only 3,000 households utilizing solar PV, either through an on-site installation or participation in a shared solar project, the potential benefits and reach of solar technology was limited. The Montana Solar Community Project (MSCP) was developed by the Montana Energy Office (MEO) at the Department of Environmental Quality in order to implement a “community-scale” solar energy strategy for the state that would cost-effectively expand Montanans’ access to solar PV. This project defines three types of community-scale solar projects: shared solar, community-sited solar, and group purchasing programs. The MSCP project conducted research and stakeholder engagement that helped to inform and develop model community-scale initiatives and an overarching community-scale solar strategy for Montana. Specifically, the project included a solar market assessment, stakeholder meetings across Montana, development of a menu of community-scale solar options, a study of solar potential on schools, community solar market research, and community-scale project implementation support. MSCP activities were successful in implementing solar projects and supporting solar development in communities across Montana. Project activities realized 280 kW of newly installed solar from two solarize programs, a shared solar array at a rural electric cooperative, and a solar array atop a Bozeman high school. The community-scale project implementation support and Solar on Schools components of the project resulted directly in the analysis and design of nearly 2 MW of distributed solar systems across the state. The Solar on Schools analysis alone produced solar designs for 25 schools, representing 920.8 kW of solar potential. Many of the deliverables from this project provide guidance on future development of community-scale solar in Montana, and resulted in a number of important conclusions about community-scale solar in Montana. There is strong interest in community-scale solar in Montana, as noted during stakeholder meetings, in response to solar market research surveys, and as seen by applications for implementation support grants provided by MEO. Project activities also suggest that Montanans demonstrated a desire and need for more information about solar energy technology, solar financing options, and the state’s policy and regulatory framework. Additionally, the project found that schools will be key partners for future community-scale solar programs. In addition to being excellent hosts for solar arrays, schools have the opportunity to use the installation of a solar array to develop educational materials and curricula to educate Montana’s future leaders about these technologies, which can be shared and replicated across the state. Project activities laid a clear path forward for solar energy in Montana. Certain activities have concrete next steps. For example, numerous solar arrays were designed for schools and other public buildings around the state. Many of those designs will be used as soon as funding becomes available. Other activities have less developed next steps, though lay the foundation for future work. The solar market assessment, solar market research, and community stakeholder meetings are good examples. These documents can be used as stepping stones to increase renewable energy education, increase stakeholder outreach, and support communities as they seek to develop community-scale solar projects.

14 SOLAR ENERGY↗

Measured Performance of a Low Temperature Air Source Heat Pump

A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.

Building America↗

Computational Elucidation of Mechanical Degradation in NMC Cathodes: Impact on Cell Performance

Next-generation lithium ion batteries are expected to demonstrate superior energy and power density with longer cycle life for successful electrification of the automobile, aviation, and marine industries. Adoption of lithium metal anodes with solid electrolytes can help to achieve that goal given that the dendrite-related issues are solved eventually. Another possibility is to use Ni-rich high-capacity NMC cathode materials with liquid and/or solid electrolytes, which presently experiences rapid capacity fade while charged to higher voltages. Several mechanical and chemical degradation mechanisms are active within these NMC-based cathode particles. Recent experimental research activities attempted to correlate the mechanical damage with the capacity fade experienced by Ni-rich LiNi x Mn y Co z O 2 (x+y+z = 1) (NMC) cathodes. Here, a computational framework is developed in this study capable of quantifying the evolution of inter primary particle and cathode/electrolyte interfacial fracture experienced by the poly- and single-crystalline NMC cathodes during charge/discharge operation. Influences of mechanical degradation on the overall cell capacity, while operating with liquid and/or solid electrolytes, are successfully characterized. Decreasing the size of the cathode primary particles, or the size of the single-crystalline cathodes, can mitigate the overall mechanical degradation, and subsequent capacity fade, experienced by NMC cathodes. The developed theoretical methodology can help the engineers and scientists to better understand the mechanical degradation mechanism prevalent in Ni-rich NMC cathodes and build superior lithium ion-based energy storage devices for the application in next-generation devices.

25 ENERGY STORAGE↗

Building America Case Study: Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Potential Role of Concentrating Solar Power within the Context of DOE's 2030 Solar Cost Targets

For solar electricity generating technologies to be cost competitive at a large scale with conventionally generated electricity, cost reductions are needed for both concentrating solar power (CSP) and solar photovoltaic (PV) systems. In 2011, the U.S. Department of Energy (DOE) established solar cost targets that corresponded to reducing CSP and PV prices by approximately 75% in order to achieve a levelized cost of electricity (LCOE) of $0.06 per kilowatt-hour (kWh) for both utility-scale PV and high-capacity factor CSP-TES systems in 2020. Utility-scale PV achieved its 2020 cost target in 2017, and recent estimates for the LCOE of CSP-TES with a molten-salt power tower system are approximately $0.10/kWh for projects that are expected to come online in 2020, which represents a substantial reduction since 2010 - when the LCOE for CSP-TES was around $0.21/kWh. To continue the momentum for cost reductions in solar technologies, DOE recently established cost targets for 2030 that would make solar one of the lowest-cost sources of new electricity in the United States. For CSP-based systems, the new targets correspond to an LCOE in 2030 of $0.05/kWh for a dispatchable, high-capacity factor CSP-TES plant configuration. This aggressive target would have been unimaginable a decade ago. However, building on the previously described reduction in CSP-TES costs over the past decade, recent announcements suggest the next phase of projects will continue this downward trend through lower installation costs, attractive financing, longer-duration PPAs, and the ability to capitalize on the value that the flexibility of storage brings CSP. This presentation summarizes a recent report that evaluates the potential impacts of simultaneously achieving the 2030 cost targets for PV and CSP-TES, and it includes a detailed evaluation of the role that CSP-TES could play in realizing those impacts. The scenarios in this analysis are designed to isolate and assess the potential impacts of achieving DOE's 2030 cost targets for CSP-TES and PV, and they do not reflect the potential benefits or system impacts associated with success in other DOE research programs. The low-cost solar scenarios include DOE's 2030 solar cost targets--which are represented via a roughly 50% reduction in LCOE by 2030 (from current levels) with additional cost reductions thereafter representing technology learning and/or improvements that could result from innovation - coupled with a variety of market, technology, and demand assumptions. With these assumptions, the evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which was specifically designed to represent the temporal and locational value of renewable generation technologies in the U.S. power system. ReEDS relies on system-wide least-cost optimization to estimate the type and location of future generation and transmission capacity. In addition, it accounts for the locational and temporal variations in variable renewable technologies, including the need for new transmission, curtailment, dynamic capacity value, and the need to hold operating reserves to account for the uncertainty and variability of these technologies. This presentation summarizes the key findings that arise from a detailed evaluation of the impacts of achieving DOE's 2030 cost targets for CSP-TES and PV systems, noting again the inherent challenges associated with modeling future scenarios of the large, complex system electricity system in the contiguous United States within the context of various market features.

14 SOLAR ENERGY↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning based design space exploration for hybrid main-memory design

We develop a machine learning (ML) based design space exploration (DSE) method that builds predictive models for various responses of a hybrid main-memory system. To overcome the challenges associated with latency, capacity, and power of memory systems in future extreme-scale machines, the hybrid memory architectures are being considered in which novel non-volatile memory (NVM) systems augment the traditional DRAM. However, way before their actual design and implementation, these emerging hybrid memory systems need to be simulated and analyzed to fully understand their capabilities and limitations. As the conventional architectural-level memory simulators require significant amounts of computational costs and time, we propose to utilize ML techniques for developing various memory-response models that can instantly provide a predicted response corresponding to any new memory configuration. Specifically, in this work, we apply four supervised ML techniques to build regression models for memory latency, bandwidth, power, and total read/write responses. The training and validation data for the ML methods are generated using NVMain memory simulator for DRAM, NVM, and their hybrid combinations. We demonstrate the results of the ML based memory-DSE method in terms of the learning curve characteristics for hyperparameter tuning and the statistical error analyses of the designed predictive models.

Sen, Satyabrata↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗