Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

First Limits on Light Dark Matter Interactions in a Low Threshold Two-Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5⁢(4) m⁢ eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g ×12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M⁢ eV/c 2 , with the lowest unexplored cross section of 4⁢ × 10 −32 c⁢m 2 at 87 M⁢ eV/c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic Ray Background Rejection with Wire-Cell LArTPC Event Reconstruction in the MicroBooNE Detector

For a large liquid-argon time-projection chamber (LArTPC) operating on or near the Earth’s surface to detect neutrino interactions, the rejection of cosmogenic background is a critical and challenging task because of the large cosmic-ray flux and the long drift time of the time-projection chamber. We introduce a superior cosmic background rejection procedure based on the Wire-Cell three-dimensional (3D) event reconstruction for LArTPCs. From an initial 1:20 000 neutrino to cosmic-ray background ratio, we demonstrate these tools on data from the MicroBooNE experiment and create a high-performance generic neutrino event selection with a cosmic contamination of 14.9% (9.7%) for a visible energy region greater than O(200) MeV. The neutrino interaction selection efficiency is 80.4% and 87.6% for inclusive ν μ charged-current and ν e charged-current interactions, respectively. Here, this significantly improved performance compared with existing reconstruction algorithms marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth’s surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unsupervised quantum circuit learning in high energy physics

Unsupervised training of generative models is a machine learning task that has many applications in scientific computing. Here, in this work, we evaluate the efficacy of using quantum circuit-based generative models to generate synthetic data of high energy physics processes. We use nonadversarial, gradient-based training of quantum circuit Born machines to generate joint distributions over two and three variables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the decay B s 0 → π 0 π 0 at Belle

We report the results of the first search for the decay B$^{0}_{s}$ → π 0 ⁢π 0 using 121.4 fb -1 of data collected at the Y⁡(5⁢S) resonance with the Belle detector at the KEKB asymmetric-energy e + ⁢e - collider. We observe no signal and set a 90% confidence level upper limit of 7.7 ×10 -6 on the B$^{0}_{s}$ → π 0 π 0 decay branching fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE’s 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated Bi 214 − Po 214 radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for β and α particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying Bi 214 − Po 214 detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive Bi 214 is detected, and a limit on the activity is placed at < 0.35 mBq / kg at the 95% confidence level. This bulk Bi 214 radiopurity limit—the first ever reported for a liquid argon detector incorporating liquid-phase purification—is then further discussed in relation to the targeted upper limit of 1 mBq / kg on bulk Rn 222 activity for the DUNE neutrino detector. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining g A / g V with High-Resolution Spectral Measurements Using a LiInSe 2 Bolometer

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g A /g V ), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. Here we present measurements performed on a high-resolution LiInSe 2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115 In . The value of g A /g V is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g A /g V at >5 σ with a model-dependent quenching factor of 0.655 ± 0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the 115 In half-life to be [5.18 ± 0.06(stat) $^{+0.005}_{- 0.015}$(sys)] x 10 14 yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-β decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νββ sensitivity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

The performance of missing transverse momentum reconstruction and its significance with the ATLAS detector using 140 $\hbox {fb}^{-1}$ of $\sqrt{s}=13$ TeV pp collisions

This paper presents the reconstruction of missing transverse momentum ($p_{\text {T}}^{\text {miss}}$ ) in proton–proton collisions, at a center-of-mass energy of 13 TeV. This is a challenging task involving many detector inputs, combining fully calibrated electrons, muons, photons, hadronically decaying $\tau$ -leptons, hadronic jets, and soft activity from remaining tracks. Possible double counting of momentum is avoided by applying a signal ambiguity resolution procedure which rejects detector inputs that have already been used. Several $p_{\text {T}}^{\text {miss}}$ ‘working points’ are defined with varying stringency of selections, the tightest improving the resolution at high pile-up by up to 39% compared to the loosest. The $p_{\text {T}}^{\text {miss}}$ performance is evaluated using data and Monte Carlo simulation, with an emphasis on understanding the impact of pile-up, primarily using events consistent with leptonic Z decays. The studies use $140~\text {fb}^{-1}$ of data, collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018. The results demonstrate that $p_{\text {T}}^{\text {miss}}$ reconstruction, and its associated significance, are well understood and reliably modelled by simulation. Finally, the systematic uncertainties on the soft $p_{\text {T}}^{\text {miss}}$ component are calculated. After various improvements the scale and resolution uncertainties are reduced by up to 76% and 51%, respectively, compared to the previous calculation at a lower luminosity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗