Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Detection of a Cobalt-Containing Interphase at the Li 6 PS 5 Cl-NMC111 Interface by In Situ μ XANES and EIS

Sulfide electrolyte all-solid-state lithium batteries (ASLBs) with uncoated Li-Ni x Mn y Co 1–x–y O 2 (NMC) cathodes suffer from a large capacity loss during initial cycling and an increase in cell impedance. Decomposition reactions are known to occur at the Li 6 PS 5 Cl-NMC111 interface due to incompatibility between the two materials. If a stabilizing coating is applied to the NMC, it delivers full capacity during initial charge. However, the loss in capacity during discharge still occurs. The interface was studied by μ XANES and through EIS analysis. A chemically-formed interphase was detected by μ XANES, evident from reduction of Co at an uncoated NMC particle surface. This interphase was produced by decomposition at rest. To study the effect of the interphase on electrochemically active surface area, piecewise in situ EIS was performed and the data was modeled using a transmission line model (TLM). The charge transfer resistance R CT was used to estimate the volume specific active surface area (a act ). The median value for a act was 296 cm –1 , a factor of 7.5 lower than the theoretical value of 2216 cm –1 . This provided evidence of a lower electrochemically active surface area in the ASLB.

36 MATERIALS SCIENCE↗

On the Source of Conductivity in Alkaline Zn Anodes: Zn Percolation and ZnO Bridging

Alkaline Zn anodes are fundamental to commercial Zn-MnO 2 batteries as well as emerging rechargeable designs. In these electrodes, Zn particles are both the active material and source of electronic conduction. However, there are known cases in which electronic connectivity between Zn particles or the current collecting pin is lost even though the battery continues to function. Here we use X-ray computed tomography (CT) of AA batteries to demonstrate several examples of Zn particle-to-particle connectivity breakdown, which is observed even in cases at relatively high discharge rate. This indicates maintenance of the electronic network through the less-conductive ZnO discharge product. We introduce a new equation for electronic conductivity maintained through bridges of ZnO formed between percolating Zn particles. This necessitates discarding the Bruggeman correlation and instead redefining effective electronic conductivity using percolation theory. We demonstrate that such a model for conduction enables prediction of an inverted reaction zone, which is an experimentally observed case in which significant Zn dissolution and ZnO formation occurs heavily near the current collecting pin. Current computational Zn-MnO 2 models never predict an inverted reaction zone, and thus the updated conductivity enables models to accurately explain a wider range of experimental conditions.

Guida, Dominick P. [Northeastern Univ., Boston, MA↗

Simulation Environment For Radiotherapy Applications

SERA is a simulation environment for planning three-dimensional neutron capture therapy. SERA can allows creating models of the geometry of the tumor and surrounding tissue from CT or MRI data, and then planning and simulating the treatment of the tumor with Boron Neutron Capture Therapy. Boron Neutron Capture Therapy uses the combination of a boron containing drug and a neutron source to treat a tumor.

Cogliati, JoshuaJ. [Idaho National Laboratory (INL↗

TRINIDI (Time-of-Flight Resonance Imaging with Neutrons for Isotopic Density Inference)

This software is an open-source Python library that provides tools for processing hyperspectral neutron time-of-flight radiography data. This type of data allows material decomposed reconstructions to be generated with the use of material characteristic spectral responses and the algorithms provided in this code library. The software library will contain tools for pre-processing the neutron measurement data, estimating measurement system parameters, reconstructing material decomposed radiographs, and computing material decomposed computed tomography (CT). Furthermore, it will have capability to generate and process simulated neutron time-of-flight data with the goal of benchmarking and demonstrating the tools that are provided. The software will include thorough documentation and application examples.

Balke, Thilo↗

Livermore Computed Tomography Input/Output library

Read, write, and connect visualizers to data for LLNL radiography and CT tools (e.g. LTT: https://softwarelicensing.llnl.gov/product/livermore-tomography-tools-ltt).

Vardar-Irrgang, MichaelE [Lawrence Livermore Natio↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

A Co-Registered In-Situ and Ex-Situ Dataset from an Electron Beam Powder Bed Fusion Additive Manufacturing Process (Peregrine v2023-09)

This release contains a co-registered in-situ and ex-situ Peregrine dataset from a single Arcam Q10 Electron Beam Powder Bed Fusion (EB-PBF) Inconel 738 build. These data were collected at the Manufacturing Demonstration Facility (MDF) located at Oak Ridge National Laboratory (ORNL). The dataset includes layer-wise Near Infrared (NIR) in-situ imaging data, in-situ temporal sensor data, ex-situ X-Ray Computed Tomography (X-CT) scans, and the target part geometries. Additionally, anomaly detections produced by a trained Dynamic Segmentation Convolutional Neural Network (DSCNN) are provided.

36 MATERIALS SCIENCE↗

A Co-Registered In-Situ and Ex-Situ Dataset from a Laser Powder Bed Fusion Additive Manufacturing Process (Peregrine v2023-10)

This release contains a co-registered in-situ and ex-situ Peregrine dataset from a single Concept Laser M2 Laser Powder Bed Fusion (L-PBF) stainless steel 316L build. These data were collected at the Manufacturing Demonstration Facility (MDF) located at Oak Ridge National Laboratory (ORNL). The dataset includes layer-wise visible-light in-situ imaging data, the laser scan paths and parameters, in-situ temporal sensor data, X-Ray Computed Tomography (X-CT) scans, pycnometry and tensile test results, etched micrographs from selected locations, and the target part geometries. Additionally, anomaly detections produced by a modified Dynamic Segmentation Convolutional Neural Network (DSCNN) are provided.

36 MATERIALS SCIENCE↗

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]↗

Insights from a workplace SARS-CoV-2 specimen collection program, with genomes placed into global sequence phylogeny

In 2020, the Department of Energy established the National Virtual Biotechnology Laboratory (NVBL) to address key challenges associated with COVID-19. As part of that effort, Pacific Northwest National Laboratory (PNNL) established a capability to collect and analyze specimens from employees who self-reported symptoms consistent with the disease. During the spring and fall of 2021, 688 specimens were screened for SARS-CoV-2, with 64 (9.3%) testing positive using reverse-transcriptase quantitative PCR (RT-qPCR). Of these, 36 samples were released for research. All 36 positive samples released for research were sequenced and genotyped. Here, the relationship between patient age and viral load as measured by Ct values was measured and determined to be only weakly significant. Consensus sequences for each sample were placed into a global phylogeny and transmission dynamics were investigated, revealing that the closest relative for many samples was from outside of Washington state, indicating mixing of viral pools within geographic regions.

59 BASIC BIOLOGICAL SCIENCES↗

A cell-based Papain-like Protease (PLpro) activity assay for rapid detection of active SARS-CoV-2 infections and antivirals

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its variants are a continuous threat to human life. An urgent need remains for simple and fast tests that reliably detect active infections with SARS-CoV-2 and its variants in the early stage of infection. Here we introduce a simple and rapid activity-based diagnostic (ABDx) test that identifies SARS-CoV-2 infections by measuring the activity of a viral enzyme, Papain-Like protease (PLpro). The test system consists of a peptide that fluoresces when cleaved by SARS PLpro that is active in crude, unprocessed lysates from human tongue scrapes and saliva. Test results are obtained in 30 minutes or less using widely available fluorescence plate readers, or a battery-operated portable instrument for on-site testing. Proof-of-concept was obtained in a study on clinical specimens collected from patients with COVID-19 like symptoms who tested positive (n = 10) or negative (n = 10) with LIAT RT-PCR using nasal mid turbinate swabs. When saliva from these patients was tested with in-house endpoint RT-PCR, 17 were positive and only 5 specimens were negative, of which 2 became positive when tested 5 days later. PLpro activity correlated in 17 of these cases (3 out of 3 negatives and 14 out of 16 positives, with one invalid specimen). Despite the small number of samples, the agreement was significant (p value = 0.01). Two false negatives were detected, one from a sample with a late Ct value of 35 in diagnostic RT-PCR, indicating that an active infection was no longer present. The PLpro assay is easily scalable and expected to detect all viable SARS-CoV-2 variants, making it attractive as a screening and surveillance tool. Additionally, we show feasibility of the platform as a new homogeneous phenotypic assay for rapid screening of SARS-CoV-2 antiviral drugs and neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

Tailoring optical response of MXene thin films

Due to their attractive optical properties, 2D MXenes have garnered interest in nanophotonic and optoelectronic applications. However, tuning their properties typically requires the iterative synthesis of MXenes with a specific set of properties, such as the absorption band position, electronic conductivity, and dielectric constant. We demonstrate how to tailor the optical properties of MXene thin films over a broad 1500-nm wavelength range by mixing different ratios of highly conductive Ti 3 C 2 T x with poorly conductive Nb 2 CT x . By changing the MXene film composition, the epsilon-near-zero (ENZ) point, where the optical properties transit from dielectric to metallic, was varied in the spectral range from 1.1 to 2.6 µm. Additionally, we observed a reduction in absorption in some compositions compared to the absorption of the pure MXene films. Compared to other methods, this approach enables simple and continual tuning of MXene optical properties without requiring multiple time-consuming synthesis steps.

2D materials↗

Fracture Description of the HFTS-2 Slant Core, Delaware Basin, West Texas

Previous work in the Midland Basin Hydraulic Fracture Test Site project (HFTS1) has shown the value of core recovered from a stimulated volume in providing information on the geometry and extent of hydraulic fractures. This project (HFTS2) is in the Wolfcamp Formation of the Delaware Basin. A slant core through the stimulated volume was acquired above and below a stimulated well and the results of the fracture description are presented here. Here, nine, 3-inch-diameter whole cores from the slant well were examined for fractures prior to slabbing, together with a CT scan of the core. We used criteria developed during the HFTS1 project to identify hydraulic, natural, drilling-induced and core-handling fractures. Material collected from a few fracture faces was cleaned, sieved, and examined under a microscope to look for proppant. A total of 1261 fractures, including 500 hydraulic fractures, were described in 948 feet of core. Hydraulic fractures are not evenly distributed through the cores; they tend to occur in clusters. Many are remarkably planar, smooth, and featureless, while others have twist hackles, steps, plumose, and kinks. Natural, subvertical fractures, mostly less than 1 mm in width, sealed with blocky calcite, are oriented NE-SW (Set 1) and WNW-ESE (Set 2). Two Set 1 fractures have drusy cement on parted faces and were possibly open prior to drilling. A few subvertical sealed fractures with different orientations are also present. Bed-parallel natural fractures, most having fibrous cement (beef), and some showing top-to-north bed-parallel shear are present. Faults with normal/oblique movement were found in one part of the core. Drilling induced and core-handling breaks were identified in all cores, and were also noted to have reactivated some natural fractures. The results from this work will allow hydraulic fracture distribution relative to the stimulated well to be assessed. The number of fractures is generally greater than the number of perforations, but these can be compared for different stages and perforation clusters. Surface features provide information about the direction of hydraulic fracture propagation and about segmentation and bifurcation that might increase the number of fracture strands. Reactivation of natural fractures, including bedding-parallel fractures, occurs although the mechanism of parting is mostly unknown. The wider HFTS2 project will make use of this fracture description to improve hydraulic fracture modeling (geomechanics and engineering), to help explain pressure depletion and fiber optics observations (reservoir depletion and frac geometry), to help verify indirect fracture diagnostic techniques such as microseismic monitoring (geophysics), and to help calibrate horizontal well image logs.

58 GEOSCIENCES↗

A review of materials used in tomographic volumetric additive manufacturing

Abstract Volumetric additive manufacturing is a novel fabrication method allowing rapid, freeform, layer-less 3D printing. Analogous to computer tomography (CT), the method projects dynamic light patterns into a rotating vat of photosensitive resin. These light patterns build up a three-dimensional energy dose within the photosensitive resin, solidifying the volume of the desired object within seconds. Departing from established sequential fabrication methods like stereolithography or digital light printing, volumetric additive manufacturing offers new opportunities for the materials that can be used for printing. These include viscous acrylates and elastomers, epoxies (and orthogonal epoxy-acrylate formulations with spatially controlled stiffness) formulations, tunable stiffness thiol-enes and shape memory foams, polymer derived ceramics, silica-nanocomposite based glass, and gelatin-based hydrogels for cell-laden biofabrication. Here we review these materials, highlight the challenges to adapt them to volumetric additive manufacturing, and discuss the perspectives they present. Graphical abstract

36 MATERIALS SCIENCE↗

Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale

Computed tomography scans of fractures in small samples of Wolfcamp Shale from the Permian Basin and a depth of approximately 10,400 feet that have been cemented through natural processes. These samples were CT scanned at NETL. The data sets compliment the manuscript by Hajirezaie et al entitled "Mineral characterization of a sealed fracture: A multiscale multimodal imaging study of a syntaxial vein"

Computed Tomography↗

Core Characterization of the Whipkey ST1 Well - Marcellus Shale

CT and geophysical data of the Marcellus from the Whipkey ST 1 well in Greene Co PA API No: 37-059-24715 latitude 39.9000020N, longitude -80.0199970W Please see the following technical report for further details. Crandall, D.; Moore, J.; Brown, S.; Mackey, P.; Carr, T. Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 54.

Computed Tomography↗