Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Gigahertz-gated InGaAs/InP single-photon detector with detection efficiency exceeding 55% at 1550 nm

We report on a gated single-photon detector based on InGaAs/InP avalanche photodiodes (APDs) with a single-photon detection efficiency exceeding 55% at 1550 nm. Our detector is gated at 1 GHz and employs the self-differencing technique for gate transient suppression. It can operate nearly dead time free, except for the one clock cycle dead time intrinsic to self-differencing, and we demonstrate a count rate of 500 Mcps. We present a careful analysis of the optimal driving conditions of the APD measured with a dead time free detector characterization setup. It is found that a shortened gate width of 360 ps together with an increased driving signal amplitude and operation at higher temperatures leads to improved performance of the detector. We achieve an afterpulse probability of 7% at 50% detection efficiency with dead time free measurement and a record efficiency for InGaAs/InP APDs of 55% at an afterpulse probability of only 10.2% with a moderate dead time of 10 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Emission Profile And Neutron Spectrum Measurements At JET: Status And Plans

In large tokamak devices, such as JET, TFTR, JT-60U and ITER, a neutron emission profile monitor is considered as one of the principal diagnostic tools, firstly in providing information to characterize the fusion source in terms of its location, shape, intensity and secondly in developing an understanding of fast ion physics in tokamak plasmas. The JET neutron profile monitor is one of the most advanced such instruments currently operating. It enables 2-D imaging of the non-circular plasma neutron source through a tomographic deconvolution of line-integrated measurements. Historically it was usually assumed that the fusion neutron source is a function of the magnetic flux surfaces (MFS), but recent JET results have clearly demonstrated the influence of non-uniform fast particle populations on the neutron emission profile.Neutron energy spectroscopy also carries valuable information about fast ion behaviour and the fusion and nuclear reactions taking place in the plasma. Spectrum measurements of neutrons will be particularly important for the up-coming JET experiments with a Be wall. The neutron spectroscopy capabilities at JET were recently enhanced by several instruments: a new time-of-flight spectrometer optimized for high count rates (TOFOR), compact neutron spectrometers based on organic scintillator (NE213) and an upgrade of the Magnetic Proton Recoil system (MPRu). In recent JET campaigns, a prototype digital pulse shape discriminator (DPSD) has been successfully tested on one central chord of the JET neutron profile monitor and spectral information has also been obtained. Neutron spectrometry results obtained during the last JET experimental campaigns illustrate the measurement capabilities and indicate their potential use on ITER. Several projects are in progress to further develop such diagnostic capabilities and these are briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

CeSOX: Short-Distance Neutrino Oscillations with BoreXino

Several experimental anomalies in neutrino physics may point to the possible existence of one or more additional neutrino species that do not interact weakly, the so-called sterile neutrinos. The third phase of the Borexino experiment (SOX) is devoted to verification of this hypothesis. Within the first stage (CeSOX) the count rate of antineutrino events in the liquid scintillation detector from the artificial source {sup 1}44Ce–{sup 1}44Pr placed in the special pit beneath the setup will be measured. The smaller antineutrino flux, as compared to the original one, would indicate the presence of oscillations into sterile states. This paper gives a survey of the CeSOX experiment, including the general description, the characterization of the radioactive source and the specific features of its use, the description of the method for data analysis, and the expected results. Depending on the significance of the obtained scientific information, the decision on carrying out the second stage of the SOX experiment with the {sup 51}Cr source of electron neutrinos will be made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Euratom Fast Collar (EFC): A Safeguards Instrument Design to Address Future Fuel Measurement Challenges

Summary of this presentation: (1) EFC instrument design for {sup 235}U verification measurements issued to EURATOM to issue a call for commercial tender; (2) Achieved a fast (Cd mode) measurement with less than 2% relative uncertainty in the doubles neutron counting rate in 10 minutes using a standard source strength; (3) Assay time in fast mode consistent with the needs of an inspector; (4) Extended to realistic calibration range for modern fuel designs - Relatively insensitive to gadolinia content for fuel designs with up to 32 burnable poison rods and 15 wt % gadolinia concentration, which is a realistic maximum for modern PWR fuel; (5) Improved performance over the standard thermal neutron collar with greater than twice the efficiency of the original design; (6) Novel tube pattern to reduce the impact of accidental pile-up; and (7) Joint test of prototype unit - EURATOM-LANL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radon induced surface contaminations in low background experiments

In neutrinoless double-beta decay and dark matter searches, one of the main issues is to increase the experimental sensitivity through careful material selection and production, minimizing the background contributions. In order to achieve the required, extremely low, counting rates, very stringent requirements must be fulfilled in terms of bulk material radiopurity. As the experimental sensitivity increases, the bulk impurities in the detector components decrease, and surface contaminations start to play an increasingly significant role In fully active detectors, like cryogenic particle detectors, surface contaminations are a critical issue (as shown by the CUORICINO experiment). {sup 222}Rn is by far the most intense source of airborne radioactivity, and if a radio-pure material is exposed to environment where the Radon concentration is not minimized, {sup 210}Pb and {sup 210}Po contaminations can occur. The mechanisms and the dynamics of Radon-induced surface contaminations are reviewed, and specific solutions to prevent and to reject the induced background are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CHANDRA/HETGS CENSUS OF X-RAY VARIABILITY FROM Sgr A* DURING 2012

We present the first systematic analysis of the X-ray variability of Sgr A* during the Chandra X-ray Observatory's 2012 Sgr A* X-ray Visionary Project. With 38 High Energy Transmission Grating Spectrometer observations spaced an average of 7 days apart, this unprecedented campaign enables detailed study of the X-ray emission from this supermassive black hole at high spatial, spectral and timing resolution. In 3 Ms of observations, we detect 39 X-ray flares from Sgr A*, lasting from a few hundred seconds to approximately 8 ks, and ranging in 2-10 keV luminosity from {approx}10{sup 34} erg s{sup -1} to 2 Multiplication-Sign 10{sup 35} erg s{sup -1}. Despite tentative evidence for a gap in the distribution of flare peak count rates, there is no evidence for X-ray color differences between faint and bright flares. Our preliminary X-ray flare luminosity distribution dN/dL is consistent with a power law with index -1.9{sup +0.3}{sub -0.4}; this is similar to some estimates of Sgr A*'s near-IR flux distribution. The observed flares contribute one-third of the total X-ray output of Sgr A* during the campaign, and as much as 10% of the quiescent X-ray emission could be comprised of weak, undetected flares, which may also contribute high-frequency variability. We argue that flares may be the only source of X-ray emission from the inner accretion flow.

79 ASTRONOMY AND ASTROPHYSICS↗

The ECLAIRs telescope onboard the SVOM mission for gamma-ray burst studies

The X- and gamma-ray telescope ECLAIRs onboard the future mission for gamma-ray burst studies SVOM (Space-based multi-band astronomical Variable Objects Monitor) is foreseen to operate in orbit from 2013 on. ECLAIRs will provide fast and accurate GRB triggers to other onboard telescopes, as well as to the whole GRB community, in particular ground-based follow-up telescopes. With its very low energy threshold ECLAIRs is particularly well suited for the detection of highly redshifted GRB. The ECLAIRs X- and gamma-ray imaging camera (CXG), used for GRB detection and localization, is combined with a soft X-ray telescope (SXT) for afterglow observations and position refinement. The CXG is a 2D-coded mask imager with a 1024 cm{sup 2} detection plane made of 80x80 CdTe pixels, sensitive from 4 to 300 keV, with imaging capabilities up to about 120 keV and a localization accuracy better than 10 arcmin. The CXG permanently observes a 2 sr-wide field of the sky and provides photon data to the onboard science and triggering unit (UTS) which detects GRB by count-rate increases or by the appearance of a new source in cyclic sky images. The SXT is a mirror focusing X-ray telescope operating from 0.3 to 2 keV with a sensitivity of 1 mCrab for 100 s observations. The spacecraft slews within {approx_equal}3 min in order to place the GRB candidate into the 23x23 arcmin{sup 2} field of view of the SXT, after which it refines the GRB position to about 10 arcsec. GRB alerts are transmitted to ground-observers within tens of seconds via a VHF network and all detected photons are available hours later for detailed analysis. In this paper we present the ECLAIRs concepts, with emphasis on the expected performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new compact solid-state neutral particle analyser at ASDEX Upgrade: Setup and physics modeling

At ASDEX Upgrade (AUG), a new compact solid-state detector has been installed to measure the energy spectrum of fast neutrals based on the principle described by Shinohara et al. [Rev. Sci. Instrum. 75, 3640 (2004)]. The diagnostic relies on the usual charge exchange of supra-thermal fast-ions with neutrals in the plasma. Therefore, the measured energy spectra directly correspond to those of confined fast-ions with a pitch angle defined by the line of sight of the detector. Experiments in AUG showed the good signal to noise characteristics of the detector. It is energy calibrated and can measure energies of 40-200 keV with count rates of up to 140 kcps. The detector has an active view on one of the heating beams. The heating beam increases the neutral density locally; thereby, information about the central fast-ion velocity distribution is obtained. The measured fluxes are modeled with a newly developed module for the 3D Monte Carlo code F90FIDASIM [Geiger et al., Plasma Phys. Controlled Fusion 53, 65010 (2011)]. The modeling allows to distinguish between the active (beam) and passive contributions to the signal. Thereby, the birth profile of the measured fast neutrals can be reconstructed. This model reproduces the measured energy spectra with good accuracy when the passive contribution is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YALINA-booster subcritical assembly pulsed-neutron e xperiments: detector dead time and apatial corrections.

In almost every detector counting system, a minimal dead time is required to record two successive events as two separated pulses. Due to the random nature of neutron interactions in the subcritical assembly, there is always some probability that a true neutron event will not be recorded because it occurs too close to the preceding event. These losses may become rather severe for counting systems with high counting rates, and should be corrected before any utilization of the experimental data. This report examines the dead time effects for the pulsed neutron experiments of the YALINA-Booster subcritical assembly. The nonparalyzable model is utilized to correct the experimental data due to dead time. Overall, the reactivity values are increased by 0.19$ and 0.32$ after the spatial corrections for the YALINA-Booster 36% and 21% configurations respectively. The differences of the reactivities obtained with He-3 long or short detectors at the same detector channel diminish after the dead time corrections of the experimental data for the 36% YALINA-Booster configuration. In addition, better agreements between reactivities obtained from different experimental data sets are also observed after the dead time corrections for the 21% YALINA-Booster configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prismatic analyser concept for neutron spectrometers

Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can readily be combined with advanced focussing geometries and with multiplexing instrument designs. We present a combination of simulations and data showing three different energies simultaneously reflected from one analyser. Experiments were performed on a cold triple axis instrument and on a prototype inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor of 2.4 in flux gain compared to a single flat analyser slab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging

Purpose: The authors assembled a prototype compact gamma-ray imaging probe (MediPROBE) for sentinel lymph node (SLN) localization. This probe is based on a semiconductor pixel detector. Its basic performance was assessed in the laboratory and clinically in comparison with a conventional gamma camera. Methods: The room-temperature CdTe pixel detector (1 mm thick) has 256x256 square pixels arranged with a 55 {mu}m pitch (sensitive area 14.08x14.08 mm{sup 2}), coupled pixel-by-pixel via bump-bonding to the Medipix2 photon-counting readout CMOS integrated circuit. The imaging probe is equipped with a set of three interchangeable knife-edge pinhole collimators (0.94, 1.2, or 2.1 mm effective diameter at 140 keV) and its focal distance can be regulated in order to set a given field of view (FOV). A typical FOV of 70 mm at 50 mm skin-to-collimator distance corresponds to a minification factor 1:5. The detector is operated at a single low-energy threshold of about 20 keV. Results: For {sup 99m}Tc, at 50 mm distance, a background-subtracted sensitivity of 6.5x10{sup -3} cps/kBq and a system spatial resolution of 5.5 mm FWHM were obtained for the 0.94 mm pinhole; corresponding values for the 2.1 mm pinhole were 3.3x10{sup -2} cps/kBq and 12.6 mm. The dark count rate was 0.71 cps. Clinical images in three patients with melanoma indicate detection of the SLNs with acquisition times between 60 and 410 s with an injected activity of 26 MBq {sup 99m}Tc and prior localization with standard gamma camera lymphoscintigraphy. Conclusions: The laboratory performance of this imaging probe is limited by the pinhole collimator performance and the necessity of working in minification due to the limited detector size. However, in clinical operative conditions, the CdTe imaging probe was effective in detecting SLNs with adequate resolution and an acceptable sensitivity. Sensitivity is expected to improve with the future availability of a larger CdTe detector permitting operation at shorter distances from the patient skin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pile-up recovery in gamma-ray detection

Count rates in gamma-ray detectors are fundamentally limited at the high end by the physics of the detection process but should not be limited further by the design of read-out. Using intense stimuli, such as the ELI, it is desirable to extract the full wealth of information flow that sensors can deliver. We discuss the photon-statistical limitations of scintillation systems and charge-collection issues of solid-state detectors. With high-speed digitizing in particular, two promising approach architectures are those of posterior list mode corrections and of time-domain adaptive filters, introducing a 'rich list mode with uncertainties' and thus a somewhat different look at experimental spectra. Real-time performance is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for the GeV counterparts of two gamma ray bursts: Swift 317662 and Fermi bn081017474

We examine the possibility of the ground observation of the GeV counterparts of two gamma ray bursts, the Swift GRB-080723 (Trigger=317662) and the Fermi GRB081017474 (trigger=bn081017474). The data come from two small directional muon telescopes at sea level inside the South Atlantic Anomaly region. This characteristic offers the muon telescopes a low rigidity of response to primary and secondary charged particles ({>=}0.4 GV). In both cases, the GRB trigger coordinates are within the effective field of view of the vertical Tupi muon telescopes. There is a ground level enhancement (GLE) on the muon counting rate background, with a statistical significance above 4{sigma}, 38.22 minutes after the Swift trigger occurrence, and there are at least two GLEs, with a significance above 4{sigma}, at 7.2 minutes and 19.2 minutes after the Fermi trigger, respectively. We argue that the GeV counterpart of a keV GRB could be similar to the highest GRBs, observed by EGRET within BATSE's field of view, where the high-energy emission arrives at the detector in fragments, and they are delayed and/or anticipated with respect to the keV-MeV burst. This behavior is observed in both cases. In short, the analysis suggests that they may be physically associated. Details and some implications of this possible association are reported in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

{sup 39}Ar Detection at the 10{sup -16} Isotopic Abundance Level with Atom Trap Trace Analysis

Atom trap trace analysis, a laser-based atom counting method, has been applied to analyze atmospheric {sup 39}Ar (half-life=269 yr), a cosmogenic isotope with an isotopic abundance of 8x10{sup -16}. In addition to the superior selectivity demonstrated in this work, the counting rate and efficiency of atom trap trace analysis have been improved by 2 orders of magnitude over prior results. The significant applications of this new analytical capability lie in radioisotope dating of ice and water samples and in the development of dark matter detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗