Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Coherent Cone-Beam X-ray Microscopy

A novel full-field imaging method using the (111) Bragg diffraction of a sub-micron gold crystal as the divergent cone-beam for sample illumination is reported. The divergence of the illumination allows for very high magnification, limited only by the achievable ratio of the crystal-to-sample and sample-to-detector distances. In this case an x-ray magnification of approximately 115 was achieved.

43 PARTICLE ACCELERATORS↗

Light Cone Dynamics and EMC Effects in the Extraction of F{sub 2n} at Large Bjorken x

We discuss theoretical issues related to the extraction of deep inelastic (DIS) structure function of neutron from inclusive DIS scattering off the deuteron at large Bjorken x. Theoretical justification is given to the consideration of only pn component of the deuteron wave function and consistency with both the baryonic number and light-cone momentum conservation sum rules. Next we discuss the EMC type effects and argue that in all cases relevant to the nuclear DIS reactions at large x the main issue is the medium modification of the properties of bound nucleon rather than the non-nucleonic components like pions. We give brief description of the color screening model of EMC and within this model we estimate uncertainties in the extraction of the neutron DIS structure function at large x. We emphasize also that these uncertainties are rather ''model independent'' since any theoretical framework accounting for the medium modification is proportional to the magnitude of the virtuality of bound nucleon which increases with an increase of x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pion-photon transition form factor in light-cone sum rules

We extract constraints on the pion distribution amplitude from available data on the pionphoton transition form factor in the framework of light-cone sum rules. A pronounced discrepancy (2.7 - 3){sigma} between the Gegenbauer expansion coefficients extracted from the CELLO, CLEO, and Belle experimental data relative to those from BaBar is found. Predictions for the pion-photon transition form factor are presented by employing a pion distribution amplitude obtained long ago from QCD sum rules with nonlocal condensates. These predictions comply with the Belle data but disagree with those of BaBar beyond 9 GeV{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strain-induced gap transition and anisotropic Dirac-like cones in monolayer and bilayer phosphorene

The electronic properties of two-dimensional monolayer and bilayer phosphorene subjected to uniaxial and biaxial strains have been investigated using first-principles calculations based on density functional theory. Strain engineering has obvious influence on the electronic properties of monolayer and bilayer phosphorene. By comparison, we find that biaxial strain is more effective in tuning the band gap than uniaxial strain. Interestingly, we observe the emergence of Dirac-like cones by the application of zigzag tensile strain in the monolayer and bilayer systems. For bilayer phosphorene, we induce the anisotropic Dirac-like dispersion by the application of appropriate armchair or biaxial compressive strain. Our results present very interesting possibilities for engineering the electronic properties of phosphorene and pave a way for tuning the band gap of future electronic and optoelectronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The geometry of the light-cone cell decomposition of moduli space

The moduli space of Riemann surfaces with at least two punctures can be decomposed into a cell complex by using a particular family of ribbon graphs called Nakamura graphs. We distinguish the moduli space with all punctures labelled from that with a single labelled puncture. In both cases, we describe a cell decomposition where the cells are parametrised by graphs or equivalence classes of finite sequences (tuples) of permutations. Each cell is a convex polytope defined by a system of linear equations and inequalities relating light-cone string parameters, quotiented by the automorphism group of the graph. We give explicit examples of the cell decomposition at low genus with few punctures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced target normal sheath acceleration of protons from intense laser interaction with a cone-tube target

Laser driven proton acceleration is proposed to be greatly enhanced by using a cone-tube target, which can be easily manufactured by current 3D-print technology. It is observed that energetic electron bunches are generated along the tube and accelerated to a much higher temperature by the combination of ponderomotive force and longitudinal electric field which is induced by the optical confinement of the laser field. As a result, a localized and enhanced sheath field is produced at the rear of the target and the maximum proton energy is about three-fold increased based on the two-dimentional particle-in-cell simulation results. It is demonstrated that by employing this advanced target scheme, the scaling of the proton energy versus the laser intensity is much beyond the normal target normal sheath acceleration (TNSA) case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strain engineering band gap, effective mass and anisotropic Dirac-like cone in monolayer arsenene

The electronic properties of two-dimensional puckered arsenene have been investigated using first-principles calculations. The effective mass of electrons exhibits highly anisotropic dispersion in intrinsic puckered arsenene. Futhermore, we find that out-of-plane strain is effective in tuning the band gap, as the material undergoes the transition into a metal from an indirect gap semiconductor. Remarkably, we observe the emergence of Dirac-like cone with in-plane strain. Strain modulates not only the band gap of monolayer arsenene, but also the effective mass. Our results present possibilities for engineering the electronic properties of two-dimensional puckered arsenene and pave a way for tuning carrier mobility of future electronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An exact Jacobi map in the geodesic light-cone gauge

The remarkable properties of the recently proposed geodesic light-cone (GLC) gauge allow to explicitly solve the geodesic-deviation equation, and thus to derive an exact expression for the Jacobi map J{sup A}{sub B}(s,o) connecting a generic source s to a geodesic observer o in a generic space time. In this gauge J{sup A}{sub B} factorizes into the product of a local quantity at s times one at o, implying similarly factorized expressions for the area and luminosity distance. In any other coordinate system J{sup A}{sub B} is simply given by expressing the GLC quantities in terms of the corresponding ones in the new coordinates. This is explicitly done, at first and second order, respectively, for the synchronous and Poisson gauge-fixing of a perturbed, spatially-flat cosmological background, and the consistency of the two outcomes is checked. Our results slightly amend previous calculations of the luminosity-redshift relation and suggest a possible non-perturbative way for computing the effects of inhomogeneities on observations based on light-like signals.

79 ASTRONOMY AND ASTROPHYSICS↗

Geodesic-light-cone coordinates and the Bianchi I spacetime

The geodesic-light-cone (GLC) coordinates are a useful tool to analyse light propagation and observations in cosmological models. In this article, we propose a detailed, pedagogical, and rigorous introduction to this coordinate system, explore its gauge degrees of freedom, and emphasize its interest when geometric optics is at stake. We then apply the GLC formalism to the homogeneous and anisotropic Bianchi I cosmology. More than a simple illustration, this application (i) allows us to show that the Weinberg conjecture according to which gravitational lensing does not affect the proper area of constant-redshift surfaces is significantly violated in a globally anisotropic universe; and (ii) offers a glimpse into new ways to constrain cosmic isotropy from the Hubble diagram.

79 ASTRONOMY AND ASTROPHYSICS↗

Gauge-transformation properties of cosmological observables and its application to the light-cone average

Theoretical descriptions of observable quantities in cosmological perturbation theory should be independent of coordinate systems. This statement is often referred to as gauge-invariance of observable quantities, and the sanity of their theoretical description is verified by checking its gauge-invariance. We argue that cosmological observables are invariant scalars under diffeomorphisms and their theoretical description is gauge-invariant, only at linear order in perturbations. Beyond linear order, they are usually not gauge-invariant, and we provide the general law for the gauge-transformation that the perturbation part of an observable does obey. We apply this finding to derive the second-order expression for the observational light-cone average in cosmology and demonstrate that our expression is indeed invariant under diffeomorphisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Light cone sum rules for the {pi}{sup 0}{gamma}{sup *}{gamma} form factor revisited

We provide a theoretical update of the calculations of the {pi}{sup 0}{gamma}{sup *}{gamma} form factor in the light cone sum rules framework, including up to six polynomials in the conformal expansion of the pion distribution amplitude and taking into account twist-six corrections related to the photon emission at large distances. The results are compared with the calculations of the B{yields}{pi}l{nu} decay and pion electromagnetic form factors in the same framework. Our conclusion is that the recent BABAR measurements of the {pi}{sup 0}{gamma}{sup *}{gamma} form factor at large momentum transfers [B. Aubert et al. (The BABAR Collaboration), Phys. Rev. D 80, 052002 (2009)] are consistent with QCD, although they do suggest that the pion distribution amplitude may have more structure than usually assumed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higher twist parton distributions from light-cone wave functions

We explore the possibility to construct higher-twist parton distributions in a nucleon at some low reference scale from convolution integrals of the light-cone wave functions (WFs). To this end we introduce simple models for the four-particle nucleon WFs involving three valence quarks and a gluon with total orbital momentum zero, and estimate their normalization (WF at the origin) using QCD sum rules. We demonstrate that these WFs provide one with a reasonable description of both polarized and unpolarized parton densities at large values of the Bjorken variable x{>=}0.5. Twist-three parton distributions are then constructed as convolution integrals of qqqg and the usual three-quark WFs. The cases of the polarized structure function g{sub 2}(x,Q{sup 2}) and single transverse spin asymmetries are considered in detail. We find that the so-called gluon pole contribution to twist-three distributions relevant for single spin asymmetry vanishes in this model, but is generated perturbatively at higher scales by the evolution, in the spirit of Glueck-Reya-Vogt parton distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

B{yields}{pi}l{nu}{sub l} width and |V{sub ub}| from QCD light-cone sum rules

We employ the B{yields}{pi} form factors obtained from QCD light-cone sum rules and calculate the B{yields}{pi}l{nu}{sub l} width (l=e, {mu}) in units of 1/|V{sub ub}|{sup 2}, integrated over the region of accessible momentum transfers, 0{<=}q{sup 2{<=}}12.0 GeV{sup 2}. Using the most recent BABAR Collaboration measurements we extract |V{sub ub}|=(3.50{sub -0.33}{sup +0.38}|{sub th{+-}}0.11|{sub exp})x10{sup -3}. The sum rule results for the form factors, taken as an input for a z-series parametrization, yield the q{sup 2} shape in the whole semileptonic region of B{yields}{pi}l{nu}{sub l}. We also present the charged lepton energy spectrum in this decay. Furthermore, the current situation with B{yields}{tau}{nu}{sub {tau}} is discussed from the QCD point of view. We suggest using the ratio of the B{yields}{pi}{tau}{nu}{sub {tau}} and B{yields}{pi}l{nu}{sub l}(l={mu},e) widths as an additional test of the standard model. The sensitivity of this observable to new physics is illustrated by including a charged Higgs-boson contribution in the semileptonic decay amplitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

g{sub VS}{gamma} coupling constant in light cone QCD

We recalculated the coupling constants g{sub {phi}{sigma}{gamma}}, g{sub {phi}a{sub 0}{gamma}}, g{sub {omega}{sigma}{gamma}}, g{sub a{sub 0}{omega}{gamma}}, g{sub {rho}{sigma}{gamma}}, and g{sub a{sub 0}{rho}{gamma}} by taking into account the contributions of the three-particle up to twist-4 distribution amplitudes of the photon involving quark-gluon and quark-anti-quark-photon fields in the light-cone sum-rule framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Progressive cone beam CT dose control in image-guided radiation therapy

Purpose: Cone beam CT (CBCT) in image-guided radiotherapy (IGRT) offers a tremendous advantage for treatment guidance. The associated imaging dose is a clinical concern. One unique feature of CBCT-based IGRT is that the same patient is repeatedly scanned during a treatment course, and the contents of CBCT images at different fractions are similar. The authors propose a progressive dose control (PDC) scheme to utilize this temporal correlation for imaging dose reduction. Methods: A dynamic CBCT scan protocol, as opposed to the static one in the current clinical practice, is proposed to gradually reduce the imaging dose in each treatment fraction. The CBCT image from each fraction is processed by a prior-image based nonlocal means (PINLM) module to enhance its quality. The increasing amount of prior information from previous CBCT images prevents degradation of image quality due to the reduced imaging dose. Two proof-of-principle experiments have been conducted using measured phantom data and Monte Carlo simulated patient data with deformation. Results: In the measured phantom case, utilizing a prior image acquired at 0.4 mAs, PINLM is able to improve the image quality of a CBCT acquired at 0.2 mAs by reducing the noise level from 34.95 to 12.45 HU. In the synthetic patient case, acceptable image quality is maintained at four consecutive fractions with gradually decreasing exposure levels of 0.4, 0.1, 0.07, and 0.05 mAs. When compared with the standard low-dose protocol of 0.4 mAs for each fraction, an overall imaging dose reduction of more than 60% is achieved. Conclusions: PINLM-PDC is able to reduce CBCT imaging dose in IGRT utilizing the temporal correlations among the sequence of CBCT images while maintaining the quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry S. Wah Leung Endowment Fund.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures

Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Standard Dose Head protocol (100 kVp, 80 mA, 8 ms and 200 degree of rotation).The measurements were taken with thermoluminescence (TLD) EXTRAD (Harshaw) dosimeters placed in an anthropomorphic phantom over the eye and under 3 mm of bolus material to mimic the lens position. The center of the head was placed at the isocenter. To reduce TLD energy dependence, they were calibrated at the used beam quality. Results: The average lens dose at the lens in the OBI v 1.5 systems of the Clinac iX and the True Beam is 0.071 and 0.076 cGy/CBCT, respectively. Conclusions: The extra absorbed doses that receive the eye lenses due to one CBCT acquisition with the studied protocol is far below the new ICRP recommended threshold for the lens. However, the addition effect of several CBCT acquisition during the whole treatment should be taken into account.

61 RADIATION PROTECTION AND DOSIMETRY↗