Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The development of the radio frequency driven negative ion source for neutral beam injectors (invited)

Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut fuer Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

43 PARTICLE ACCELERATORS↗

Measurements of plasma parameters in a simulated thermionic converter

Cesium-filled thermionic energy converters are examined as candidate electrical energy sources in spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency inevitably impose stringent constraints on the converter fabrication to achieve the desired reliability of the power system. The converter physics for reducing operating temperatures and cesium plasma losses are studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗

Probe measurements of a cesium plasma in a simulated thermionic energy converter

Cesium-filled thermionic energy converters are considered as electrical energy sources in future spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency impose stringent constraints on the converter fabrication. The converter physics for reducing operating temperatures and cesium plasma losses are being studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗

Enhancement of persistent luminescence of ZnTa{sub 2}O{sub 6}:Pr{sup 3+} by addition Li{sup +}, Na{sup +}, K{sup +} and Cs{sup +} ions

Graphical abstract: The incorporation of the alkali metals (Li, Na, K and Cs) as co-dopants in ZnTa{sub 2}O{sub 6}:Pr{sup 3+} phosphor improved the lifetime of the persistent emission by increasing the quantity of the electron trapping centres. - Highlights: • ZnTa{sub 2}O{sub 6}:Pr{sup 3+} was co-doped with Li{sup +}, Na{sup +}, K{sup +} or Cs{sup +} ions. • Phase pure samples were synthesised. • Enhancement of the persistent emission was achieved by co-doping. • Corresponding electron trapping centres were quantified by a TL reader. - Abstract: Enhancement of the persistent emission was achieved by co-doping ZnTa{sub 2}O{sub 6}:Pr{sup 3+} with Li{sup +}, Na{sup +}, K{sup +} or Cs{sup +} ions. Phase pure samples were synthesised and it was confirmed by the X-ray diffraction pattern which matches that of the standard data. Incorporation of the co-dopant ions introduced strain into the phosphor, which increased with an increase in the ionic radius of the co-dopant ion. The scanning electron microscope image shows that the particles were agglomerated, and the surface images obtained using the Time of flight secondary ion mass spectroscopy showed that the dopant and the co-dopant ions in the phosphor were homogeneously distributed. The persistent emission was enhanced by the co-dopant ions as shown by the lifetime values calculated from the phosphorescence decay curves, and the corresponding electron trapping centres were quantified by thermoluminescence reader.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oak Ridge 25URC Tandem Accelerator 2007 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species 80Ge and 17,18F accounted for 763 of these hours. This included an experiment using 17F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich 81Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. The majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes. This ion source uses a quartz tube in the transfer line between the production target and the ion source to selectively slow down some elements such as rubidium and cesium.

43 PARTICLE ACCELERATORS↗

Initial study of the optical spectrum of the ISIS H{sup -} ion source plasma

The front end test stand is being constructed at the Rutherford Appleton Laboratory, with the aim of producing a 60 mA, 2 ms, 50 Hz, perfectly chopped H{sup -} ion beam. To meet the beam requirements, a more detailed understanding of the ion source plasma is required. To this end, an initial study is made of the optical spectrum of the plasma using a digital spectrometer. The atomic and molecular emission lines of hydrogen and caesium are clearly distinguished and a quantitative comparison is made when the ion source is run in different conditions. The electron temperature is 0.6 eV and measured line widths vary by up to 75%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maintenance and operation procedure, and feedback controls of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The maintenance and operation procedure to minimize the plasma chamber (PCH) replacement time on the beam line, which is very important to maximize the J-PARC beam time especially for an antenna failure, is presented in this paper. The PCH preserved by filling argon (Ar) gas inside after pre-conditioning including pre-cesiation to produce the required beam at a test-stand successfully produced the required beam on the beam line with slight addition of cesium (Cs). The methods of the feedback controls of a 2MHz-RF-matching, an H{sup −} ion beam intensity and the addition of Cs are also presented. The RF-matching feedback by using two vacuum variable capacitors (VVCs) and RF-frequency shift produced the almost perfect matching with negligibly small reflected RF-power. The H{sup −} ion beam intensity was controlled within errors of ±0.1mA by the RF-power feedback. The amount of Cs was also controlled by remotely opening a Cs-valve to keep the RF-power lower than a settled value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a quadrupole-based Secondary-Ion Mass Spectrometry (SIMS) system at Lewis Research Center

The design, construction, and initial use of an ion microprobe to carry out secondary ion mass spectrometry (SIMS) of solid samples is reported. The system is composed of a differentially pumped custom-made UHV (Ultra High Vacuum) chamber, a quadrupole mass spectrometer and a telefocus A-DIDA ion gun with the capability of producing beams of Cesium, as well as inert and reactive gases. The computer control and acquisition of the data were designed and implemented using a personal computer with plug-in boards, and external circuitry built as required to suit the system needs. The software is being developed by using a FORTH-like language. Initial tests aimed at characterizing the system, as well as preliminary surface and depth-profiling studies are presently underway.

Vargas-Aburto, Carlos↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

Fundamental Chemistry of Cesium Extraction from Acidic Media by HCCD in FS-13

We previously published a model for cesium extraction from acidic media by the protonated form of the hexachlorinated derivative of the chloro-protected cobalt bis(dicarbollide), HCCD, dissolved in trifluoromethylphenyl sulfone, FS-13. The model indicated that Cs extraction proceeds through a series of ion-paired and/or dissociated extraction equilibria. Additional Cs distribution ratio data has been obtained and the model refined and simplified. It is demonstrated that the equilibrium exclusively involving the exchange of proton for cesium by formation of ion-paired CsCCD models the Cs distribution data very well, particularly for the concentrations of HCCD greater than 0.0005 M (0.5 mM). Finally, activity corrections for the aqueous phase to the Cs distribution data results in good agreement to the theoretical value of -1 for slope (log-log) analysis of the data over a wide range of HNO3 and HCCD concentrations.

cesium↗

Design of a versatile multiaperture negative ion source

Negative ion sources are a key component of the neutral beam injector to be installed in the International Thermonuclear Experimental Reactor. At present research and development activities address several important issues related to beam extraction, optics, and optimization. Together with the design of real size devices and the accumulation of atomic cross section databases, a relatively small negative ion source [130 mA of H{sup -} at 60 kV, named Negative Ion Optimization phase 1 (NIO1)] is under construction at Consorzio RFX to contribute to benchmark numerical simulation tools and to test components, such as emittance scanners, beam dumps, and cesium ovens. NIO1 design, magnet configuration, and rf coupling simulations are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H- Ion Sources for High Intensity Proton Drivers

Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H + and H - ion generation around 3 to 5 mA/cm 2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm 2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

43 PARTICLE ACCELERATORS↗

Hanford Tank Side Cesium Removal System: Process Description and Performance Metrics - 19613

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by spent fuel reprocessing on the Hanford site. It further describes TSCR component design features, system performance metrics and operational sequences used for liquid waste treatment, as well as spent ion exchange column (IXC) replacement and storage. This presentation should be of great interest to parties responsible for treatment and disposal of liquid waste containing high concentrations of cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Na Concentration on Cs Distribution with Crystalline Silicotitanate in Tank Waste Simulants

Crystalline silicotitanate (CST) ion exchange media is currently utilized in the tank side cesium removal (TSCR) system on the Hanford site to remove Cs-137 from the tank waste supernate. As the main dose contributor to the liquid supernate in Hanford tank waste, it is necessary to remove the Cs-137 to expedite low activity waste processing and immobilization. Ongoing batch contact experiments with CST have been done to tease out the impact of group II metals, anions, potassium, and temperature on Cs removal to better understand bounding conditions for operations as well as aid in development of a wholesome isotherm model to predict Cs behavior in the tank waste. This paper discusses the impact of Na concentration on Cs exchange and provides insight into the challenges associated with activity coefficient estimations for modeling Cs distribution in tank waste matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydraulic Permeability of Resorcinol-Formaldehyde Ion-Exchange Resin - Effects of Oxygen Uptake and Radiation

An ion-exchange process, using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the U.S. Department of Energy's (DOE) Hanford site in Washington State. The RF resin is also being evaluated for use in the proposed Small Column Ion Exchange (SCIX) system, which is an alternative treatment option at DOE's Savannah River Site (SRS)in South Carolina. Testing at ORNL will determine the impact of radiation exposure and oxygen uptake by the RF resin on the hydraulic permeability of the resin. Samples of the resin will be removed periodically to measure physical properties (bead size and compressibility) and cesium capacity. The proposed full-scale treatment system at Hanford, the Waste Treatment Plant (WTP), will use an ion-exchange column containing nominally 680 gal of resin, which will treat 30 gpm of waste solution. The ion-exchange column is designed for a typical pressure drop of 6 psig, with a maximum of 9.7 psig. The lab-scale column is 3-in. clear PVC pipe and is prototypic of the proposed Hanford column. The fluid velocity in the lab-scale test will be much higher than for the full-scale column, in order to generate the maximum pressure drop expected in that column (9.7 psig). The frictional drag from this high velocity will produce similar forces on the resin in the lab-scale column as would be expected at the bottom of the full-scale column. The chemical changes in the resin caused by radiation exposure and oxygen uptake are expected to cause physical changes in the resin that could reduce the bed porosity and reduce the hydraulic permeability of the resin bed. These changes will be monitored by measuring the pressure drop through the lab-scale column and by measuring the physical properties of samples of the resin. The test loop with the lab-scale column is currently being fabricated, and operation will start by late May. Testing will be completed by the end of August.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Permeability of Resorcinol-Formaldehyde Resin

An ion exchange process using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the Hanford Site, using large scale columns as part of the Waste Treatment Plant (WTP). The RF resin is also being evaluated for use in the proposed small column ion exchange (SCIX) system, which is an alternative treatment option at Hanford and at the Savannah River Site (SRS). A recirculating test loop with a small ion exchange column was used to measure the effect of oxygen uptake and radiation exposure on the permeability of a packed bed of the RF resin. The lab-scale column was designed to be prototypic of the proposed Hanford columns at the WTP. Although the test equipment was designed to model the Hanford ion exchange columns, the data on changes in the hydraulic permeability of the resin will also be valuable for determining potential pressure drops through the proposed SCIX system. The superficial fluid velocity in the lab-scale test (3.4-5.7 cm/s) was much higher than is planned for the full-scale Hanford columns to generate the maximum pressure drop expected in those columns (9.7 psig). The frictional drag from this high velocity produced forces on the resin in the lab-scale tests that matched the design basis of the full-scale Hanford column. Any changes in the resin caused by the radiation exposure and oxygen uptake were monitored by measuring the pressure drop through the lab-scale column and the physical properties of the resin. Three hydraulic test runs were completed, the first using fresh RF resin at 25 C, the second using irradiated resin at 25 C, and the third using irradiated resin at 45 C. A Hanford AP-101 simulant solution was recirculated through a test column containing 500 mL of Na-form RF resin. Known amounts of oxygen were introduced into the primary recirculation loop by saturating measured volumes of the simulant solution with oxygen and reintroducing the oxygenated simulant into the feed tank. The dissolved oxygen (DO) concentration of the recirculating simulant was monitored, and the amount of oxygen that reacted with the resin was determined from the change in the DO concentration of the recirculating simulant solution. Prior to hydraulic testing the resin for runs 2 and 3 was covered with the simulant solution and irradiated in a spent fuel element at the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Both batches of resin were irradiated to a total gamma dose of 177 Mrad, but the resin for run 2 reached a maximum temperature during irradiation of 51 C, while the resin for run 3 reached a temperature of 38 C. The different temperatures were the result of the operating status of HFIR at the time of the irradiation and were not part of the test plan; however, the results clearly show the impact of the higher-temperature exposure during irradiation. The flow rate and pressure drop data from the test loop runs show that irradiating the RF resin reduces both the void fraction and the permeability of the resin bed. The mechanism for the reduction in permeability is not clear because irradiation increases the particle size of the resin beads and makes them deform less under pressure. Microscopic examination of the resin beads shows that they are all smooth regular spheres and that irradiation or oxygen uptake did not change the shape of the beads. The resin reacts rapidly with DO in the simulant solution, and the reaction with oxygen reduces the permeability of a bed of new resin by about 10% but has less impact on the permeability of irradiated resin. Irradiation increases the toughness of the resin beads, probably by initiating cross-linking reactions in them. Oxygen uptake reduces the crush strength of both new and irradiated resin; however, the pressures that caused the beads to crush are much higher than would be expected during the operation of an ion exchange column. There was no visible evidence of broken beads in any of the resin samples taken from the test loop. Reaction with oxygen reduces the cesium distribution coefficient of the resin beads, as does irradiation. Higher temperatures during irradiation or during contact with the simulant solution further reduce the cesium distribution coefficient.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A laboratory study of collisional electrostatic ion cyclotron waves

The effects of neutral-particle collisions on electrostatic ion cyclotron instability are analyzed. Experiments were conducted in the Q machine of Motley (1975) with a cesium plasma in which the neutral gas pressure in the main chamber varied from about 5 microtorr-10 mtorr. The relation between electrostatic ion cyclotron wave amplitude and frequency and neutral argon pressure is examined. It is observed that over the full range of neutral pressure the frequency changes by less than 10 percent and the ion cyclotron waves continue to be excited and reach amplitudes of at least several percent at values of the neutral pressure where the ion-neutral collision frequency/ion gyrofrequency is about 0.3.

Suszcynsky, D. M.↗