Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Omega3P: A Parallel Finite-Element Eigenmode Analysis Code for Accelerator Cavities

Omega3P is a parallel eigenmode calculation code for accelerator cavities in frequency domain analysis using finite-element methods. In this report, we will present detailed finite-element formulations and resulting eigenvalue problems for lossless cavities, cavities with lossy materials, cavities with imperfectly conducting surfaces, and cavities with waveguide coupling. We will discuss the parallel algorithms for solving those eigenvalue problems and demonstrate modeling of accelerator cavities through different examples.

43 PARTICLE ACCELERATORS↗

Progress of ILC High Gradient SRF Cavity R&D at Jefferson Lab

Latest progress of ILC high gradient SRF cavity R&D at Jefferson Lab will be presented. 9 out of 10 real 9-cell cavities reached an accelerating gradient of more than 38 MV/m at a unloaded quality factor of more than 8 {center_dot} 109. New understandings of quench limitation in 9-cell cavities are obtained through instrumented studies of cavities at cryogenic temperatures. Our data have shown that present limit reached in 9-cell cavities is predominantly due to localized defects, suggesting that the fundamental material limit of niobium is not yet reached in 9-cell cavities and further gradient improvement is still possible. Some examples of quench-causing defects will be given. Possible solutions to pushing toward the fundamental limit will be described.

43 PARTICLE ACCELERATORS↗

An update on the study of high-gradient elliptical SRF cavities at 805 MHz for proton and other applications

An update on the study of 805 MHz elliptical SRF cavities that have been optimized for high gradient will be presented. An optimized cell shape, which is still appropriate for easy high pressure water rinsing, has been designed with the ratios of peak magnetic and electric fields to accelerating gradient being 3.75 mT/(MV/m) and 1.82, respectively. A total of 3 single-cell cavities have been fabricated. Two of the 3 cavities have been tested so far. The second cavity achieved an E{sub acc} of {approx}50 MV/m at Q{sub 0} of 1.4 x 10{sup 10}. This result demonstrates that 805 MHz cavities can, in principle, achieve as high as, or could even be better than, 1.3 GHz high-gradient cavities.

43 PARTICLE ACCELERATORS↗

A path to higher Q0 with large grain niobium cavities

The improvement of the quality factor Q{sub 0} of superconducting radio-frequency (SRF) cavities at medium accelerating gradients ({approx} 20 MV/m) is important in order to reduce the cryogenic losses in continuous wave accelerators for a variety of applications. In recent years, SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. Initial studies demonstrated the improvement of Q{sub 0} at medium field in cavities heat treated at 800-1000 C without subsequent chemical etching. To further explore this treatment procedure, a new induction furnace with an all-niobium hot-zone was commissioned. A single-cell 1.5 GHz cavity fabricated from ingot material from CBMM, Brazil, with RRR {approx} 200, was heat treated with the new furnace in the temperature range 600-1200 C for several hours. Residual resistance values 1-5 nano-ohm have been consistently achieved on this cavity as well as Q{sub 0} values above {approx} 2 x 10{sup 11} at 2 K and 100 mT peak surface magnetic field. Q{sub 0}-values of the order of 10{sup 11} have been measured at 1.5 K.

43 PARTICLE ACCELERATORS↗

The first operation of 56 MHz SRF cavity in RHIC

A 56 MHz superconducting RF cavity has been designed, fabricated and installed in the Relativistic Heavy Ion Collider (RHIC). The cavity operates at 4.4 K with a “quiet helium source” to isolate the cavity from environmental acoustic noise. The cavity is a beam driven quarter wave resonator. It is detuned and damped during injection and acceleration cycles and is brought to operation only at store energy. For a first test operation, the cavity voltage was stabilized at 300 kV with full beam current. Within both Au + Au and asymmetrical Au + He3 collisions, luminosity improvement was detected from direct measurement, and the hourglass effect was reduced. One higher order mode (HOM) coupler was installed on the cavity. We report in this paper on our measurement of a broadband HOM spectrum excited by the Au beam.

43 PARTICLE ACCELERATORS↗

Injector Cavities Fabrication, Vertical Test Performance and Primary Cryomodule Design

After the electromagnetic design and the mechanical design of a β=0.6, 2-cell elliptical SRF cavity, the cavity has been fabricated. Then both 2-cell and 7-cell cavities have been bench tuned to the target values of frequency, coupling external Q and field flatness. After buffer chemistry polishing (BCP) and high pressure rinses (HPR), Vertical 2K cavity test results have been satisfied the specifications and ready for the string assembly. We will report the cavity performance including Lorenz Force Detuning (LFD) and Higher Order Modes (HOM) damping data. Its integration with cavity tuners to the cryomodule design will be reported.

43 PARTICLE ACCELERATORS↗

RECENT STUDIES ON THE CURRENT LIMITATIONS OF STATE-OF-THE-ART Nb3Sn CAVITIES

Recent advances in the study of Nb3Sn at Cornell University have yielded single-cell cavities that show excellent performance without the limiting Q-slope seen in previous work. This performance has been shown to be repeatable across multiple cavities. However, they are still limited by a quench field of approximately 16 MV/m, as well as residual resistance. In this work we present results quantifying the impact of ambient magnetic fields on Nb3Sn cavities, as well as discuss the impact of cavity cooldown procedures on cavity performance. Finally, we will briefly discuss XRD results that shed light on the composition of the Nb3Sn layer and how this relates to the current limits of these cavities.

Nb3Sn↗

Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

Performance of 3.9 GHz SRF cavities at Fermilab's ILCTA_MDB nhorizontal test stand

Fermilab is building a cryomodule containing four 3.9 GHz superconducting radio frequency (SRF) cavities for the Free electron LASer in Hamburg (FLASH) facility at the Deutsches Elektronen-SYnchrotron (DESY) laboratory. Before assembling the cavities into the cryomodule, each individual cavity is tested at Fermilab's Horizontal Test Stand (HTS). The HTS provides the capability to test fully-dressed SRF cavities at 1.8 K with high-power pulsed RF in order to verify that the cavities achieve performance requirements under these conditions. The performance at the HTS of the 3.9 GHz cavities built for FLASH is presented here.

43 PARTICLE ACCELERATORS↗

Rescoring Docking Hit Lists for Model Cavity Sites: Predictions And Experimental Testing

Molecular docking computationally screens thousands to millions of organic molecules against protein structures, looking for those with complementary fits. Many approximations are made, often resulting in low 'hit rates'. A strategy to overcome these approximations is to rescore top-ranked docked molecules using a better but slower method. One such is afforded by molecular mechanics-generalized Born surface area (MM-GBSA) techniques. These more physically realistic methods have improved models for solvation and electrostatic interactions and conformational change compared to most docking programs. To investigate MM-GBSA rescoring, we re-ranked docking hit lists in three small buried sites: a hydrophobic cavity that binds apolar ligands, a slightly polar cavity that binds aryl and hydrogen-bonding ligands, and an anionic cavity that binds cationic ligands. These sites are simple; consequently, incorrect predictions can be attributed to particular errors in the method, and many likely ligands may actually be tested. In retrospective calculations, MM-GBSA techniques with binding-site minimization better distinguished the known ligands for each cavity from the known decoys compared to the docking calculation alone. This encouraged us to test rescoring prospectively on molecules that ranked poorly by docking but that ranked well when rescored by MM-GBSA. A total of 33 molecules highly ranked by MM-GBSA for the three cavities were tested experimentally. Of these, 23 were observed to bind-these are docking false negatives rescued by rescoring. The 10 remaining molecules are true negatives by docking and false positives by MM-GBSA. X-ray crystal structures were determined for 21 of these 23 molecules. In many cases, the geometry prediction by MM-GBSA improved the initial docking pose and more closely resembled the crystallographic result; yet in several cases, the rescored geometry failed to capture large conformational changes in the protein. Intriguingly, rescoring not only rescued docking false positives, but also introduced several new false positives into the top-ranking molecules. We consider the origins of the successes and failures in MM-GBSA rescoring in these model cavity sites and the prospects for rescoring in biologically relevant targets.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperat

43 PARTICLE ACCELERATORS↗

1500 MHZ Passive SRF Cavity for Bunch Lengthening in the NSLS-II Storage Ring

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. After an extensive investigation of different cavity geometries, a passive, superconducting two-cell cavity has been selected for prototyping. The cavity is HOM damped with ferrite absorbers on the beam pipes. The two-cell cavity simplifies the tuner design, compared to having two independent cells. Tradeoffs between the damping of the higher order modes, thermal isolation associated with the large beam tubes, and overall cavity length are described. A copper prototype has been constructed, and measurements of fundamental and higher order modes will be compared to calculated values.

43 PARTICLE ACCELERATORS↗

Measurements of SCRF cavity dynamic heat load in horizontal test system

The Horizontal Test System (HTS) at Fermilab is currently testing fully assembled, dressed superconducting radio frequency (SCRF) cavities. These cavities are cooled in a bath of superfluid helium at 1.8K. Dissipated RF power from the cavities is a dynamic heat load on the cryogenic system. The magnitude of heat flux from these cavities into the helium is also an important variable for understanding cavity performance. Methods and hardware used to measure this dynamic heat load are presented. Results are presented from several cavity tests and testing accuracy is discussed.

43 PARTICLE ACCELERATORS↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗

Computing resonant modes of accelerator cavities by solving nonlinear eigenvalue problems via rational approximation

Here, we present an efficient and reliable algorithm for solving a class of nonlinear eigenvalue problems arising from the modeling of particle accelerator cavities. The eigenvalue nonlinearity in these problems results from the use of waveguides to couple external power sources or to allow certain excited electromagnetic modes to exit the cavity. We use a rational approximation to reduce the nonlinear eigenvalue problem first to a rational eigenvalue problem. We then apply a special linearization procedure to turn the rational eigenvalue problem into a larger linear eigenvalue problem with the same eigenvalues, which can be solved by existing iterative methods. By using a compact scheme to represent both the linearized operator and the eigenvectors to be computed, we obtain a numerical method that only involves solving linear systems of equations of the same dimension as the original nonlinear eigenvalue problem. We refer to this method as a compact rational Krylov (CORK) method. We implemented the CORK method in the Omega3P module of the Advanced Computational Electromagnetic 3D Parallel (ACE3P) simulation suite and validated it by comparing the computed cavity resonant frequencies and damping Q factors of a small model problem to those obtained from a fitting procedure that uses frequency responses computed by another ACE3P module called S3P. We also used the CORK method to compute trapped modes damped in an ideal eight 9-cell SRF cavity cryomodule. This was the first time it was possible to compute these modes directly. The damping Q factors of the computed modes match well with those measured in experiments and the difference in resonant frequencies is within the range introduced by cavity imperfection. Therefore, the CORK method is an extremely valuable tool for computational cavity design.

43 PARTICLE ACCELERATORS↗

Observations of Density Cavities and Associated Warm Ion Flux Enhancements in the Inner Magnetosphere

We present a statistical study of density cavities observed in the inner magnetosphere by the Van Allen Probes during four one-month periods: February 2013, July 2013, January 2014, and June 2014. These periods were chosen to allow the survey of all magnetic local times. We find that density cavities are a recurrent feature of the density profiles of in situ measurements in the inner magnetosphere. We further investigate the correlation between the density cavities and the enhancement of fluxes of warm ions with energies of 10–100 eV. The results show that warm ion flux enhancements associated with the density cavities were observed more frequently for H + , then for He + and the least frequently for O + . The occurrences of the associated flux enhancements were increased when considering only the cavities inside the plasmasphere. Possible mechanisms responsible for the observed warm ion flux enhancements and the role of density cavities on these ion flux enhancements are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband continuous single-mode tuning of a short-cavity quantum-cascade VECSEL

Changing the length of a laser cavity is a simple method for continuously tuning the wavelength of a laser but is rarely used for broad fractional tuning, with a notable exception of the vertical-cavity surface-emitting laser (VCSEL). This is because, to avoid mode hopping, the cavity must be kept optically short to ensure a large free spectral range compared to the gain bandwidth of the amplifying material. Terahertz quantum-cascade lasers are ideal candidates for such a short cavity scheme as they demonstrate exceptional gain bandwidths (up to octave spanning) and can be integrated with broadband amplifying metasurfaces. Our report presents such a quantum-cascade metasurface-based vertical-external-cavity surface-emitting laser (VECSEL) that exhibits over 20% continuous fractional tuning of a single laser mode. Such tuning is possible because the metasurface has subwavelength thickness, which allows lasing on low-order Fabry–Pérot cavity modes. Good beam quality and high output power are simultaneously obtained.

42 ENGINEERING↗

Low-loss stable storage of 1.2 Å X-ray pulses in a 14 m Bragg cavity

Here, we present an experimental demonstration of a stable, low-loss, large X-ray cavity operating at 1.2 Å wavelength. The cavity consists of four separate high-reflectivity single crystal diamond Bragg mirrors arranged in a rectangular configuration with a round-trip distance of 14.2 m. Femtosecond X-ray pulses from an X-ray free-electron laser were coupled into the cavity via a transmission phase grating. We show that a stable mode can be maintained with the introduction of cavity focusing and measure round-trip efficiencies approaching 88%, or >96% when excluding grating and lens losses, close to the Bragg mirror theoretical performance limit. The direct observation of sustained stable X-ray circulation provides the most direct evidence to date that cavity-based X-ray free-electron lasers and other cavity-based hard X-ray systems are feasible.

47 OTHER INSTRUMENTATION↗