Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

561 records · Page 32

In-Situ Laser Diagnostics to Understand Plasma-Surface Interactions in Titanium Thin Film Deposition

During the current project period the following tasks were completed: (1) We demonstrated the feasibility of a new way of measuring CH3 radicals in a plasma environment using a single, femtosecond (fs) pulsed laser for the first time, in a CH4 + Ar flow. A single fs pulsed Ti:Sa laser was split into two beams and with beam conversion using crystals we generatedtwo beams of 275 nm and 205 nm. The 275 nm was used to predissociate the CH3 radicals to CH2+H, followed by 205 nm Two Photon Laser Induced Fluorescence (TALIF) detection of H atoms, with a 11 ns delay from 275 nm predissociation pulse. (2) We demonstrated preliminary CH3 concentration measurements with spatial (< 100 µm) and time resolution (< 10 ns) by image processing of H and Kr TALIF signal images. (3) The methodology to quantify CH3 concentrations was developed. (4) Preliminary measurements of laser dissociation cross sections for CH4 and CH3 to (CH3+H), and (CH2+H), respectively, were conducted. (5) 275 nm laser dissociation of CH4 is a multiphoton process, and the CH4 dissociation cross section is a more sensitive function of the laser pulse energy than CH4 concentration. In the coming months, we will make more precise measurements of the dissociation cross sections, 𝑘275, 𝐶𝐻4 and 𝑘275, 𝐶𝐻3, by varying the laser energy while keeping the flow composition and conditions constant. This will enable more precise quantification of CH3 radical concentrations. More detailed measurements of CH3 radicals will be conducted in the following months of 2025 (Sept-Dec) in a Titanium Isopropoxide (TIP) + H2 + Ar flow meant for pure phase Ti thin film deposition by Chemical Vapor Deposition (CVD). More precise measurements of 275 nm laser dissociation cross sections for CH4 (to CH3 + H) and CH3 (to CH2 + H) will be conducted in the future. Detailed 275 nm laser predissociation cross sections for CH4 and CH3 dissociation to (CH3+H), and (CH2+H), respectively, as a function of gas heating, plasma power, and laser pulse energy will be evaluated. This will enable quantification of CH3 concentrations in the precursor flow over a substrate with time and spatial resolution. Comparison of the concentrations with 2D numerical simulations can lead to understanding of plasma surface interactions during pure metallic Ti thin film deposition using environmentally safer non-halogen TIP precursor. Flow conditions for pure Ti thin film deposition using non-halogen precursor (TIP) will be identified in the following months.

Uddi, Mruthunjaya [Advanced Cooling Technologies, ↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of phase changes in monoolein during high viscous injection

Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗