Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BUNDLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Electric Motor Thermal Management Research: Annual Progress Report

Past work in the area of active convective cooling provided data on the average convective heat transfer coefficients of circular orifice automatic transmission fluid (ATF) jets impinging on stationary targets intended to represent the wire bundle surface of the motor end-winding. Work during FY16 focused on the impact of alternative jet geometries that could lead to improved cooling over a larger surface of the motor winding. Results show that the planar jet heat transfer coefficients over a small (12.7-mm-diameter) target surface are not too much lower than for the circular orifice jet in which all of the ATF from the jet impinges on the target surface. The planar jet has the potential to achieve higher heat transfer over a larger area of the motor end winding. A new test apparatus was constructed to measure the spatial dependence of the heat transfer relative to the jet nozzle over a larger area representative of a motor end-winding. The tested planar flow geometry has the potential to provide more uniform cooling over the full end-winding surface versus the conventional jet configuration. The data will be used by motor designers to develop thermal management strategies to improve motor power density. Work on passive thermal design in collaboration with Oak Ridge National Laboratory to measure the thermal conductivity of wire bundle samples representative of end-winding and slot-winding materials was completed. Multiple measurement techniques were compared to determine which was most suitable for measuring composite wire bundle samples. NREL used a steady-state thermal resistance technique to measure the direction-dependent thermal conductivity. The work supported new interactions with industry to test new materials and reduce passive-stack thermal resistance in motors, leading to motors with increased power density. NREL collaborated with Ames Laboratory in the area of material characterization. The work focused on measuring the transverse rupture strength of new magnet materials developed at Ames. The impact of the improved transverse rupture strength is a mechanically stronger magnet that is easier for manufacturers to implement into motor designs. The thermal conductivity of the new magnet materials was also measured in comparison to two commercially available AlNiCo magnet materials. The impact of the thermal conductivity of the magnet material will need to be analyzed in the context of a motor application.

30 DIRECT ENERGY CONVERSION↗

Accelerator-Driven Subcritical System for Disposing of the U.S. Spent Nuclear Fuel Inventory

The current United States inventory of the spent nuclear fuel (SNF) is ~80,000 metric tons of heavy metal (MTHM), including ~131 tons of minor actinides (MAs) and ~669 tons of plutonium. This study describes a conceptual design of an accelerator-driven subcritical (ADS) system for disposing of this SNF inventory by utilizing the 131 tons of MAs inventory and a fraction of the plutonium inventory for energy production, and transmuting some long-lived fission products. An ADS system with a homogeneous subcritical fission blanket was first examined. A spallation neutron source is used to drive the blanket and it is produced from the interaction of a 1-GeV proton beam with a lead-bismuth eutectic (LBE) target. The blanket has a liquid mobile fuel using LBE as the fuel carrier. The fuel materials are dissolved, mixed, or suspended in the liquid fuel carrier. Monte Carlo analyses were performed to determine the overall parameters of the concept. Steady-state Monte Carlo simulations were performed for three similar fission blankets. Except for, the loaded amount of actinide materials in the LBE is either 5, 7, or 10% of the total volume of the blanket, respectively. The neutron multiplication factors of the three blankets are ~0.98 and the initial MAs blanket inventories are ~10 tons. In addition, Monte Carlo burnup simulations using the MCB5 code were performed to analyze the performance of the three conceptual ADS systems. During operation, fresh fuel was fed into the fission blanket to adjust its reactivity and to control the system power. The burnup analysis shows that the three ADS concepts consume about 1.2 tons of actinides per full power year and produce 3 GW thermal power, with a proton beam power of 25 MW. For the blankets with 5, 7, or 10% actinide fuel particles loaded in the LBE, assuming that the ADS systems can be operated for 35 full-power years, the total MA materials consumed in the three ADS systems are about 30.6, 35.3, and 37.2 tons, respectively. Thus, the corresponding numbers of ADS systems to utilize the 131 tons of MA materials of the SNF inventory are 4.3, 3.7, or 3.5, respectively. ADS concepts with tube bundles inserted in the fission blanket were analyzed to overcome the disadvantages of the homogeneous blanket concept. The liquid lead is used as the target material, the mobile fuel carrier, and the primary coolant to avoid the polonium production from bismuth. Reactor physics and thermal-hydraulic analyses were coupled to determine the parameters of the heterogeneous fission blanket. The engineering requirements for a satisfactory operation performance of the HT-9 ferritic steel structure material have been realized. Two heterogeneous concepts of the subcritical fission blanket with the liquid lead mobile fuel inside or outside the tube bundles were considered. The heterogeneous configuration with the mobile fuel inside the tubes showed better performance than the configuration with mobile fuel outside the bundle tubes. The Monte Carlo burnup codes, MCB5 and SERPENT were both used to simulate the fuel burnup in the ADS concepts with the mobile fuels inside the tubes. The burnup analyses were carried out for 35 full power years. The results show that 5 ADS systems can dispose of the total United States inventory of the spent nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dissolution of Material Test Reactor Fuel in an H-Canyon Dissolver

In an amended record of decision for the management of spent nuclear fuel (SNF) at the Savannah River Site, the US Department of Energy has authorized the dissolution and recovery of U from 1000 bundles of Al-clad SNF. The SNF is fuel from domestic and foreign research reactors and is typically referred to as Material Test Reactor (MTR) fuel. Bundles of MTR fuel containing assemblies fabricated from U-Al alloys (or other U compounds) are currently dissolved using a Hg-catalyzed HNO 3 flowsheet. Since the development of the existing flow sheet, improved experimental methods have been developed to more accurately characterize the offgas composition and generation rate during laboratory dissolutions. Recently, these new techniques were successfully used to develop a flowsheet for the dissolution of High Flux Isotope Reactor (HFIR) fuel. Using the data from the HFIR dissolution flowsheet development and necessary laboratory experiments, the Savannah River National Laboratory (SRNL) was requested to define flowsheet conditions for the dissolution of MTR fuels. With improved offgas characterization techniques, SRNL will be able define the number of bundles of fuel which can be charged to an H-Canyon dissolver with much less conservatism.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zeolite Membrane Reactor for Pre-Combustion Carbon Dioxide Capture (Final Scientific/Technical Report)

Water-gas shift (WGS) reaction followed by carbon dioxide (CO 2 ) separation is a critical step in the integrated gasification combined cycle (IGCC) process for fossil-fuel-fired electrical power generation with CO 2 capture. To intensify the IGCC process hydrogen-permselective zeolite membrane reactor offers promise to replace the conventional energy-intensive fixed-bed reactors and solvent-based CO 2 capture units. The objectives of this project were to develop a bench-scale zeolite membrane reactor (total membrane area: 932 cm 2 for a 21-tube membrane bundle) for the water-gas-shift reaction of raw syngas from an oxygen-blown coal-gasifier for H 2 production with simultaneous CO 2 separation at the capability of about 2 kilograms H 2 per day (equivalent to 2 kW IGCC power plant) and to demonstrate significant progress toward achieving overall performance goal of 90% CO 2 capture rate with 95% CO 2 purity at the cost of electricity 30% less than the baseline carbon capture approaches. This report summarizes results obtained in this project on scaling up the zeolite membrane reactor by a factor of 200 in membrane area, tests of the bench-scale zeolite membrane reactor for the water-gas-shift reaction at high temperature and high-pressure, and techno-economic analysis of the integration of the zeolite membrane reactor in IGCC power plant for the electrical generation with CO 2 capture. With effective pore modification by catalytic cracking deposition of MDES (methyldiethoxysilane), fabrication of MFI-type zeolite membranes was successfully scaled-up from a lab-scale disk type to bench-scale multiple-tube bundles on low-cost alumina supports. A Co-Mo based sour shift catalyst was evaluated and used in the zeolite membrane reactors for water-gas-shift reaction. The reaction kinetic and gas-permeation equations were developed and employed in mathematic models to guide/predict experiments/performance of zeolite membrane reactors for water-gas shift reaction. Multiple-tube zeolite membrane bundles and reactors were designed, fabricated and tested for gas separation and water-gas-shift reactions with real raw syngas from a coal-fired gasifier operated at high temperature and pressure. The zeolite membrane reactors demonstrated good long-term thermal and chemical stability and constant H 2 permeance (>300 GPU) together with a Knudsen selectivity (~4.7) for H 2 over CO 2 in the field test (cumulative time >28 hours) with high-sulfur coal-derived syngas. The zeolite-membrane-reactor integrated IGCC process was designed using the performance experimentally measured by the University of Cincinnati team with a single-tube zeolite membrane reactor that offers a CO conversion >98% with more than 90% of CO 2 and H 2 captured. With the above integrative approaches, a techno-economic analysis for a cost-benefit comparison was performed to uncover features that determine the power output, capital expenditure, operating expenditure, cost of electricity and cost of CO 2 capture in a 550-MW zeolite-membrane-reactor integrated IGCC process. The integration of the zeolite membrane reactor in IGCC could provide a significant reduction of 80% and 27% in the power consumption for Selexol™ Acid Gas Removal and CO 2 compression, respectively, which lowers the total auxiliary power consumption by 12.5%. However, the low pressure required at permeate stream for maintaining the driving force of hydrogen permeation through the zeolite membrane costs a huge power in permeate compressor, compensating the power consumption reduction achieved with the membrane reactor. Thus, for coal-fired IGCC for electricity generation with 90% CO 2 captured, the integration of the membrane reactor could provide a CO conversion ~99% and a significant drop in cost-of-electricity using zeolite membrane with H 2 permeance >600 GPU and the H 2 /CO 2 selectivity over 70.

01 COAL, LIGNITE, AND PEAT↗

Augmented Monitoring and Condition Assessment Program (AMCAP) Material Test Reactor (MTR) (Fuel Inspection Program Report)

The AMCAP MTR Fuel Inspection Program, a special inspection program comprised of four inspection campaigns, examined a total of ten (10) pre-selected aluminum-clad, aluminum-based fuel core spent nuclear fuel assemblies (ASNF) stored in the L Area Disassembly Basin (L Basin) at the Savannah River Site. A full description of the inspections and the results are reported. The fuel had been stored in bundled-tube storage (Vertical Tube Storage) for periods of 18 to 21 years. The prior service experience of the individual 10 assemblies varies, but all included irradiation followed by wet storage at international research reactor sites prior to shipment to the US and storage in L Basin. The 10 assemblies were expected to be among the “worst"’ in terms of prior corrosion damage of the entire inventory of the direct-bundle-stored ASNF in L Basin. The inventory of MTR ASNF in L Basin will continue to be stored in the bundled-tube configuration or in slug-storage buckets with inserts pending retrieval for ultimate disposition. The MTR fuel inspections focused on collecting information for characterization of the material condition of the ASNF considering various types of aluminum fuel corrosion degradation of its assembled materials in water storage. A custom-designed Fuel Inspection Table was used to stage the fuel for remote, enhanced visual examination (close-up video imaging & recording) with controlled lighting and positioning that enables reproducibility of imaging conditions. The inspections were conducted by fuel subject matter expert staff from Spent Fuel Project Engineering (SFPE) and the Savannah River National Laboratory (SRNL). Stills captured from the video records were used to compare the corrosion evolution from previous records, as available. This evaluation of the inspection results including the comparison to the previous inspection results demonstrate that the water quality and the storage configuration of ASNF in L Basin do not cause aggressive corrosion degradation of the fuel; mitigation of the prior corrosion degradation of the fuel also appears to have been achieved with the good water quality conditions of L Basin. Recommendations are made for future inspection of the fuel to trend corrosion degradation and demonstrate continued safe wet storage of the ASNF in L Basin. The next fuel examination is recommended to be performed in 5 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid Oxide Fuel Cell Technology Stationary Power Application Project

The objectives of this program were to: (1) Develop a reliable, cost-effective, and production-friendly technique to apply the power-enhancing layer at the interface of the air electrode and electrolyte of the Siemens SOFC; (2) Design, build, install, and operate in the field two 5 kWe SOFC systems fabricated with the state-of-the-art cylindrical, tubular cell and bundle technology and incorporating advanced module design features. Siemens successfully demonstrated, first in a number of single cell tests and subsequently in a 48-cell bundle test, a significant power enhancement by employing a power-enhancing composite interlayer at the interface between the air electrode and electrolyte. While successful from a cell power enhancement perspective, the interlayer application process was not suitable for mass manufacturing. The application process was of inconsistent quality, labor intensive, and did not have an acceptable yield. This program evaluated the technical feasibility of four interlayer application techniques. The candidate techniques were selected based on their potential to achieve the technical requirements of the interlayer, to minimize costs (both labor and material), and suitably for large-scale manufacturing. Preliminary screening, utilizing lessons learned in manufacturing tubular cells, narrowed the candidate processes to two, ink-roller coating (IRC) and dip coating (DC). Prototype fixtures were successfully built and utilized to further evaluate the two candidate processes for applying the interlayer to the high power density Delta8 cell geometry. The electrical performance of interlayer cells manufactured via the candidate processes was validated. Dip coating was eventually selected as the application technique of choice for applying the interlayer to the high power Delta8 cell. The technical readiness of the DC process and product quality was successfully and repeatedly demonstrated, and its throughput and cost are amenable to large scale manufacturing. Two 5 kWe-class SOFC power systems were built and installed for the purpose of testing and evaluating state-of-the-art tubular cell and bundle technologies, advanced generator and module design features, balance-of-plant components, and cost reduction measures. Installed at the Phipps Conservatory and Botanical Gardens, a system operated for more than 17,500 hrs, delivering electrical power to the on-site grid and thermal energy in form of hot water for onsite utilization. Operation was typically autonomous, requiring minimal operator intervention, and achieved an overall availability of greater than 85%. Outages were primarily due to an unstable local grid, two weather related outages were experienced, and very few reliability issues were encountered despite harsh operating conditions. No repairs to the stack, module, or balance-of-plant were required. A second system was designed, built, delivered, and installed at a Siemens facility in Charlotte, North Carolina. Operational issues associated with the balance-of-plant were encountered during startup and prevented the system from operating.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DISSOLUTION OF IRRADIATED MURR FUEL ASSEMBLIES

A literature survey on the dissolution of spent nuclear fuel from the University of Missouri Research Reactor (MURR) has been performed. This survey encompassed both internal and external literature sources for the dissolution of aluminum-clad uranium alloy fuels. The most limiting aspect of dissolution in the current facility configuration involves issues related to the control of the flammability of the off-gas from this process. The primary conclusion of this work is that based on past dissolution of this fuel in H-Canyon, four bundles of this fuel (initial charge) may be safely dissolved in a nitric acid flowsheet catalyzed with 0.002 M mercuric nitrate using a 40 scfm purge to control off-gas flammability. The initial charge may be followed by a second charge of up to five bundles to the same dissolver batch depending on volume and concentration constraints. The safety of this flowsheet relies on composite lower flammability limits (LFL) estimated from prior literature, pilot-scale work on the dissolution of site fuels, and the proposed processing flowsheet. Equipment modifications or improved LFL data offer the potential for improved processing rates. The fuel charging sequence, as well as the acid and catalyst concentrations, will control the dissolution rate during the initial portion of the cycle. These parameters directly impact the hydrogen and off-gas generation and, along with the purge flowrate determine the number of bundles that may be charged. The calculation approach within provides Engineering a means to determine optimal charging patterns. Downstream processing of this material should be similar to that of recent processing of site fuels requiring only minor adjustments of the existing flowsheet parameters.

08 HYDROGEN↗

Transcriptional regulation of the raffinose family oligosaccharides pathway in Sorghum bicolor reveals potential roles in leaf sucrose transport and stem sucrose accumulation

Bioenergy sorghum hybrids are being developed with enhanced drought tolerance and high levels of stem sugars. Raffinose family oligosaccharides (RFOs) contribute to plant environmental stress tolerance, sugar storage, transport, and signaling. To better understand the role of RFOs in sorghum, genes involved in myo -inositol and RFO metabolism were identified and relative transcript abundance analyzed during development. Genes involved in RFO biosynthesis ( SbMIPS1, SbInsPase, SbGolS1, SbRS ) were more highly expressed in leaves compared to stems and roots, with peak expression early in the morning in leaves. SbGolS, SbRS, SbAGA1 and SbAGA2 were also expressed at high levels in the leaf collar and leaf sheath. In leaf blades, genes involved in myo -inositol biosynthesis ( SbMIPS1, SbInsPase ) were expressed in bundle sheath cells, whereas genes involved in galactinol and raffinose synthesis ( SbGolS1, SbRS ) were expressed in mesophyll cells. Furthermore, SbAGA1 and SbAGA2 , genes that encode neutral-alkaline alpha-galactosidases that hydrolyze raffinose, were differentially expressed in minor vein bundle sheath cells and major vein and mid-rib vascular and xylem parenchyma. This suggests that raffinose synthesized from sucrose and galactinol in mesophyll cells diffuses into vascular bundles where hydrolysis releases sucrose for long distance phloem transport. Increased expression (>20-fold) of SbAGA1 and SbAGA2 in stem storage pith parenchyma of sweet sorghum between floral initiation and grain maturity, and higher expression in sweet sorghum compared to grain sorghum, indicates these genes may play a key role in non-structural carbohydrate accumulation in stems.

60 APPLIED LIFE SCIENCES↗

Black Hole Flares: Ejection of Accreted Magnetic Flux through 3D Plasmoid-mediated Reconnection

Magnetic reconnection can power bright, rapid flares originating from the inner magnetosphere of accreting black holes. We conduct extremely high-resolution (5376 × 2304 × 2304 cells) general-relativistic magnetohydrodynamics simulations, capturing plasmoid-mediated reconnection in a 3D magnetically arrested disk for the first time. We show that an equatorial, plasmoid-unstable current sheet forms in a transient, nonaxisymmetric, low-density magnetosphere within the inner few Schwarzschild radii. Magnetic flux bundles escape from the event horizon through reconnection at the universal plasmoid-mediated rate in this current sheet. The reconnection feeds on the highly magnetized plasma in the jets and heats the plasma that ends up trapped in flux bundles to temperatures proportional to the jet's magnetization. The escaped flux bundles can complete a full orbit as low-density hot spots, consistent with Sgr A* observations by the GRAVITY interferometer. Reconnection near the horizon produces sufficiently energetic plasma to explain flares from accreting black holes, such as the TeV emission observed from M87. The drop in the mass accretion rate during the flare and the resulting low-density magnetosphere make it easier for very-high-energy photons produced by reconnection-accelerated particles to escape. The extreme-resolution results in a converged plasmoid-mediated reconnection rate that directly determines the timescales and properties of the flare.

79 ASTRONOMY AND ASTROPHYSICS↗

Scanning electron microscopy of the vestibular end organs

The vestibular end organs, after chemical fixation, were freeze dried, coated with gold and palladium, and studied in the scanning microscope. Scanning microscopy gives a good three dimensional view of the sensory areas and allows study of both gross anatomy and microstructures. Cross anatomical features of the structure of the ampullae are demonstrated. The form of the statoconia in different species of animals is shown. New aspects of the structure of the sensory hairs are revealed. The hair bundles in the central areas of the cristae and in the striola of the maculae differ structurally from the hair bundles at the periphery of the sensory regions. Furthermore, some hair bundles consisting of very short stereocilia were observed. The relationship between the cupula and the statoconial membrane to the epithelial surface is discussed.

Lindeman, H. H.↗

The water factor in harvest-sprouting of hard red spring wheat

Sprouting in unthreshed, ripe, hard red spring wheat (Triticum aestivum L.) is induced by rain, but sprouting does not necessarily occur because the crop is wetted. The spike and grain water conditions conducive to sprouting were determined in a series of laboratory experiments. Sprouting did not occur in field growing wheat wetted to 110% water concentration until the spike water concentration was reduced to 12% and maintained at this concentration for 2 days before wetting. When cut at growth stage 11.3, Feekes scale, Saratovskaya 20 (USSR) sprouted after 4 days drying, Olaf and Alex between 7 and 15 days drying and Columbus, recognized for its resistance to harvest time sprouting, after more than 15 days drying. Sprouting potential was enhanced after 4 wetting drying cycles in which any wetted interval was too brief to permit sufficient water imbibition to initiate sprouting. At harvest ripeness, grain water concentration exceeded spike water concentration by 0.7 percentage units. Following 6 months storage, 20% of the kernels in 300 spike bundles (simulating windrows) sprouted within 28 hrs after initiation of wetting to saturation (150% water concentration). Ninety percent sprouting occurred within 8 days in bundles maintained at 75% water concentration and higher, but less sprouting occurred in bundles dried to 50% water concentration before resaturation.

Bauer, A.↗

A comparison of two photogrammetric algorithms for the measurement of model deformation in the National Transonic Facility

A comparison was made of two photogrammetric measurement techniques which can be used for the determination of the spatial loctions of targets. One technique is known as the Direct Linear Transformation (DLT), and the other is referred to as the Bundle method. Each technique utilizes triangulation of image data from two or more cameras, but they differ in their method of determining camera parameters. While the study was performed with simulated data, the geometries, image data accuracies and other parameters were set to simulate conditions for a two-camera, photogrammetric system which will be used at the National Transonic Facility at the NASA's Langley Research Center. For the conditions studied the Bundle technique was found to have smaller errors. Both methods were sensitive to the spatial distribution of control-point targets, but this effected the accuracy of the Bundle algorithm less than that of the DLT algorithm.

Monteith, J. H.↗

Effects of Constituent Properties on Compression Failure Mechanisms

Compression failure mechanisms were investigated through the analysis of matrix-embedded fiber bundles. The use of fiber bundle specimens can provide much needed information on compression failure mechanisms because failure of the bundle is well contained and can be monitored during testing. The method can clearly distinguish between buckling-induced failure and shear-induced failure. The results indicate that WY and T300 graphite fibers and E-glass fiber fail in buckling while the high-modulus P75S graphite fiber fails in shear. Buckling-induced failure becomes more evident with low-modulus fiber in softer epoxy.

Hahn, H. T.↗

Scintillator-fiber charged particle track-imaging detector

A scintillator-fiber charged-particle track-imaging detector was developed using a bundle of square cross section plastic scintillator fiber optics, proximity focused onto an image intensified charge injection device (CID) camera. The tracks of charged particle penetrating into the scintillator fiber bundle are projected onto the CID camera and the imaging information is read out in video format. The detector was exposed to beams of 15 MeV protons and relativistic Neon, Manganese, and Gold nuclei and images of their tracks were obtained. Details of the detector technique, properties of the tracks obtained, and preliminary range measurements of 15 MeV protons stopping in the fiber bundle are presented.

Binns, W. R.↗

Lateral distribution of high energy hadrons and gamma ray in air shower cores observed with emulsion chambers

A high energy event of a bundle of electrons, gamma rays and hadronic gamma rays in an air shower core were observed. The bundles were detected with an emulsion chamber with thickness of 15 cm lead. This air shower is estimated to be initiated with a proton with energy around 10 to the 17th power to 10 to the 18th power eV at an altitude of around 100 gmc/2. Lateral distributions of the electromagnetic component with energy above 2 TeV and also the hadronic component of energy above 6 TeV of this air shower core were determined. Particles in the bundle are produced with process of the development of the nuclear cascade, the primary energy of each interaction in the cascade which produces these particles is unknown. To know the primary energy dependence of transverse momentum, the average products of energy and distance for various average energies of secondary particles are studied.

Matano, T.↗

A capacitive technique for real-time monitoring polymer coating thickness on carbon filaments during prepregging process

A technique for gauging the coating thickness during prepreg processing of carbon fibers was developed. It is based on the concept of measuring the capacitance of a cylindrical condenser through which a bundle of prepregged fibers is passed axially. Empirical results indicate the capacitance of this condenser element is linearly related to the polymer coating thickness on the fibers in the bundle. The capacitive transducer was successfully used to measure the polymer thickness on several test fiber bundles under static conditions.

Eftekhari, Abe↗