Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Chemoembolization for Advanced Hepatocellular Carcinoma with Inferior Vena Cava and Right Atrial Tumors

Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groups based on their size: (A) >180 {mu}m, N = 9; and (B) 47-180 {mu}m, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/9 patients) for group A and 76.5% for group B (13/17 patients) (p < 0.02). No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 {mu}m) are superior to large ones (>180 {mu}m).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Ruptured Pancreaticoduodenal Artery Aneurysms Associated with Celiac Axis Stenosis

The purpose of this study was to assess the efficacy of transcatheter arterial embolization for ruptured pancreaticoduodenal artery (PDA) aneurysms associated with celiac axis stenosis (CS). Seven patients (four men and three women; mean age, 64; range, 43-84) were treated with transcatheter arterial embolization between 2002 and 2007. They were analyzed with regard to the clinical presentation, radiological finding, procedure, and outcome. All patients presented with sudden epigastric pain or abdominal discomfort. Contrast-enhanced CT showed a small aneurysm and retroperitoneal hematoma around the pancreatic head in all patients. The aneurysms ranged from 0.3 to 0.9 cm in size. In one patient, two aneurysms were detected. The aneurysms were located in the pancreaticoduodenal artery (n = 5) and the dorsal pancreatic artery (n = 3). Embolization was performed with microcoils in all aneurysms (n = 8). N-Butyl 2-cyanoacrylate (n = 1) and gelatine particle (n = 1) were also used. Complete occlusion was achieved in four patients. In the other three patients, a significantly reduced flow to the aneurysm remained at final angiography. However, these aneurysms were thrombosed on follow-up CT within 2 weeks. And there was no recurrence of the symptoms and bleeding during follow-up (mean, 28 months; range, 5-65 months) in all patients. In conclusion, transcatheter arterial embolization for PDA aneurysms associated with CS is effective. Significant reduction of the flow to the aneurysm at final angiography may be predictive of future thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of Hereditary Hemorrhagic Telangiectasia

This pictorial review is based on our experience of the follow-up of 120 patients at our multidisciplinary center for hereditary hemorrhagic telangiectasia (HHT). Rendu-Osler-Weber disease or HHT is a multiorgan autosomal dominant disorder with high penetrance, characterized by epistaxis, mucocutaneous telangiectasis, and visceral arteriovenous malformations (AVMs). The research on gene mutations is fundamental and family screening by clinical examination, chest X-ray, research of pulmonary shunting, and abdominal color Doppler sonography is absolutely necessary. The angioarchitecture of pulmonary AVMs can be studied by unenhanced multidetector computed tomography; however, all other explorations of liver, digestive bowels, or brain require administration of contrast media. Magnetic resonance angiography is helpful for central nervous system screening, in particular for the spinal cord, but also for pulmonary, hepatic, and pelvic AVMs. Knowledge of the multiorgan involvement of HHT, mechanism of complications, and radiologic findings is fundamental for the correct management of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation of Lung Tumors in Contact with the Aorta: Dangerous and Difficult but Efficient: A Report of Two Cases

Percutaneous imaging-guided tumor ablation is a widely accepted method for the treatment of primary and secondary lung tumors. Although it is generally feasible and effective for local tumor control, some conditions may affect its feasibility and effectiveness. Herein the authors report their experience with two patients with lung malignancies contiguous to the aorta who were successfully treated with radiofrequency ablation, even though it initially appeared highly risky due to the possible fatal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuous Intra-Arterial Nimodipine for the Treatment of Cerebral Vasospasm

Two patients with refractory symptomatic cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH) were treated by continuous intra-arterial nimodipine infusion via a catheter placed in the internal carotid artery or vertebral artery for 3 and 12 days, respectively. Recovery of the neurological deficits, normalization of MR perfusion, a decrease in the elevated mean flow velocity measured by transcranial duplex sonography, and angiographic recanalization were observed. Continuous intra-arterial nimodipine might be a treatment option in severe refractory vasospasm following SAH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrieval of the Protection Filter with a Soft Coaxial Catheter After Carotid Stenting

The purpose of this study was to shorten and simplify the procedure of filter retrieval after carotid stenting with cerebral protecting devices. We propose a retrieval method with a soft-tip guiding catheter, which eliminates the step of balloon exchange and introduction of a retriever catheter for the protection filter. The technique was successfully used in our last 60 consecutive patients. One transient deficit occurred. In conclusion, retrieval of the filter with a soft coaxial catheter after carotid stenting is a feasible and safe method and may simplify cerebrovascular protection during stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure and Success of Percutaneous Angioplasty in a Hypertensive Child with Bilateral Renal Artery Stenosis

We describe the clinical course of a 5-year-old girl with severe arterial hypertension that was uncontrollable with antihypertensive medication. Renal angiography revealed bilateral renal artery stenoses. Because percutaneous transluminal renal angioplasty (PTRA) failed to dilate the stenotic lesions, a renal artery bypass grafting in both renal arteries was performed. The patient remained normotensive for 7 months, and after that the arterial pressure increased again. Digital subtraction angiography demonstrated stenosis at the peripheral and central anastomosis of the vein graft that was used for revascularization of the left kidney. PTRA was decided on and successful patency was achieved. The patient has now been normotensive for a period of 5 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laceration of the Common Femoral Artery Following Deployment of the StarClose{sup TM} Vascular Closure System

StarClose is a novel arterial closure device which achieves hemostasis, following arteriotomy, via a nitinol clip deployed on the outer arterial wall. Since its introduction to the market, several studies have shown StarClose to be both safe and effective, with few major complications encountered. We report a case of common femoral artery laceration following deployment of the StarClose vascular closure system. We conclude that the injury occurred secondary to intravascular misplacement of the nitinol clip.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Approach to Treatment of Unexpected Vertebroplasty Complication

We report a novel approach to treatment of an unexpected complication of vertebroplasty. During initial positioning of transpedicular vertebroplasty needles in a 73-year-old woman, we encountered unexpected ease of needle advancement resulting in progression of the needle through the anterior cortex of the thoracic vertebral body. The transpedicular needle advanced into the mediastinum and, presumably, the adventitia of the descending thoracic aorta. Administration of polymethylmethacrylate cement was performed to tamponade bleeding at the time of the procedure and to reduce the risk of potential delayed bleeding complications within the mediastinum. The treatment was successful and the patient had no immediate or delayed complications as a result of the unintended needle advancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Superior Mesenteric Artery Pseudoaneurysm and Fistula

The uncommon presentation of an arterioportal fistula (APF) involving the superior mesenteric artery (SMA) associated with a pseudoaneurysm represents a therapeutic challenge. We present the case of a 24-year-old female admitted to the hospital after multiple gunshot wounds to the abdomen; the patient underwent multiple surgeries and, in the process, developed a SMA pseudoaneurysm and fistula. The vascular interventional radiology team was consulted for treatment of the pseudoaneurysm and fistula. A covered stent was inserted percutaneously to exclude the APF and the pseudoaneurysm in a single procedure. The patient returned to our service after 21 months for a follow-up CT scan, which demonstrated the stent and the distal vasculature to be patent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days) through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Sac Rupture in Abdominal Aortic Aneurysms Previously Excluded with Endovascular Repair (EVAR)

The purpose of this study was to assess the feasibility and effectiveness of percutaneous endovascular repair of ruptured abdominal aortic aneurysms (AAAs) previously treated by EVAR. In the last year, two male patients with AAAs, treated 8 and 23 months ago with bifurcated stent-graft, were observed because of lumbar pain and hemorragic shock. Multidetector computed tomography (MDCT) showed a retroperitoneal hematoma; in both cases a type III endoleak was detected, in one case associated with a type II endoleak from the iliolumbar artery. The procedures were performed in the theater, in emergency. Type II endoleak was treated with transcatheter superselective glue injection; type III endoleaks were excluded by a stent-graft extension. The procedures were successful in both patients, with immediate hemodynamic stabilization. MDCT after the procedure showed complete exclusion of the aneurysms. In conclusion, endovascular treatment is a safe and feasible option for the treatment of ruptured AAAs previously treated by EVAR; this approach allows avoidance of surgical conversion, which is technical very challenging, with a high morbidity and mortality rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fibromuscular Dysplasia Presenting with Bilateral Renal Infarction

Fibromuscular dysplasia (FMD) describes a group of conditions which cause nonatheromatous arterial stenoses, most commonly of the renal and carotid arteries, typically in young women. We report a rare case of bilateral segmental renal infarction secondary to FMD in a young male patient. His initial presentation with loin pain and pyrexia resulted in a delay in the definitive diagnosis of FMD. He was successfully treated with bilateral balloon angioplasty. The delayed diagnosis in this patient until the condition had progressed to bilateral renal infarcts highlights the need for prompt investigation and diagnosis of suspected cases of FMD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization Using Cisplatin Powder in a Rabbit Model of Liver Cancer

The purpose of this study was to investigate the pharmacological advantages of transarterial chemoembolization (TACE) with cisplatin powder for hypervascular hepatic tumors in animal experiments. VX2 tumors were transplanted to the livers of nine rabbits. Cisplatin (1 mg/kg) was infused into the proper hepatic artery. In the cisplatin-HAI group, cisplatin solution was infused. In the cisplatin-GS-TACE group, after infusion of cisplatin solution, gelatin sponge particles were used for embolization. In the cisplatin-Lp-TACE group, after infusion of a cisplatin powder and lipiodol (10 mg/ml) suspension, gelatin sponge particles were used for embolization. Before and after administration, platinum concentrations in plasma were measured. Using liver specimens that were excised 60 min after infusion, platinum concentrations in tumorous and nontumorous liver tissues were measured. The mean platinum concentration in tumorous tissue was 0.88 {mu}g/ml for the cisplatin-HAI group, 1.23 {mu}g/ml for the cisplatin-GS-TACE group, and 12.65 {mu}g/ml for the cisplatin-Lp-TACE group. The platinum concentration for the cisplatin-Lp-TACE group was significantly higher than that for the cisplatin-HAI group (p = 0.004) and the cisplatin-GS-TAE group (p = 0.004). The mean platinum concentration in nontumorous liver tissue was 0.98 {mu}g/ml for the cisplatin-HAI group, 1.13 {mu}g/ml for the cisplatin-GS-TACE group, and 1.09 {mu}g/ml for the cisplatin-Lp-TACE group; no significant differences were seen. At both 5 and 10 min after infusion, the platinum concentrations for the cisplatin-Lp-TACE group were lower than those for the other two groups. The present results suggest that TACE using cisplatin powder/lipiodol suspension and gelatin sponge for hypervascular hepatic tumors has a number of pharmacological advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Recurrence of a Hepatic Artery Aneurysm After Treatment Using an Endovascular Stent

Endovascular stent placement and coil embolization have become established options in the treatment of visceral arterial aneurysms. In this article we report the case of an 83-year-old presenting with gastrointestinal hemorrhage due to a recurrent hepatic arterial aneurysm occurring 12 years after treatment with an endovascular stent. The recurrent aneurysm had resulted from stent fracture and was successfully treated by coil embolization. To our knowledge, stent fracture complicating the endovascular treatment of a visceral artery aneurysm has not been described in the published literature. With the increasing use of metallic endoprostheses in interventional radiology, recognizing and reporting device failure are of critical importance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗