Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗

High Resolution BPM Upgrade for the ATF Damping Ring at KEK

A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facility (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Oxygen-Beam Texturing of Glucose-Monitoring Optics

An improved method has been devised for using directed, hyperthermal beams of oxygen atoms and ions to impart desired textures to the tips of polymethylmethacrylate [PMMA] optical fibers to be used in monitoring the glucose content of blood. The improved method incorporates, but goes beyond, the method described in Texturing Blood-Glucose- Monitoring Optics Using Oxygen Beams (LEW-17642-1), NASA Tech Briefs, Vol. 29, No. 4 (April 2005), page 11a. The basic principle of operation of such a glucose-monitoring sensor is as follows: The textured surface of the optical fiber is coated with chemicals that interact with glucose in such a manner as to change the reflectance of the surface. Light is sent down the optical fiber and is reflected from, the textured surface. The resulting change in reflectance of the light is measured as an indication of the concentration of glucose. The required texture on the ends of the optical fibers is a landscape of microscopic cones or pillars having high aspect ratios (microscopic structures being taller than they are wide). The average distance between hills must be no more than about 5 mso that blood cells (which are wider) cannot enter the valleys between the hills, where they would interfere with optical sensing of glucose in the blood plasma. On the other hand, the plasma is required to enter the valleys, and high aspect ratio structures are needed to maximize the surface area in contact with the plasma, thereby making it possible to obtain a given level of optical glucose-measurement sensitivity with a relatively small volume of blood. There is an additional requirement that the hills be wide enough that a sufficient amount of light can propagate into them and, after reflection, can propagate out of them. The method described in the cited prior article produces a texture comprising cones and pillars that conform to the average-distance and aspect-ratio requirements. However, a significant fraction of the cones and pillars are so narrow that not enough light can propagate along them. The improved method makes it possible to form wider cones and pillars while still satisfying the average-distance and aspect-ratio requirements. In the improved method, as in the previously reported method, multiple optical fibers are first bundled together for simultaneous texturing of their distal tips. However, prior to texturing by exposure to an oxygen beam, the tips are first coated by vapor deposition of a thin, sparse layer of aluminum: The exposure to the aluminum vapor must be short enough (typically of the order of seconds) so that the aluminum nucleates into islands separated by uncoated areas. The coated tips are textured by exposure to a directed beam of hyperthermal (kinetic energy >1 eV) oxygen atoms and/or ions in a vacuum chamber, as in the previously reported method. The aluminum islands partially shield the underlying PMMA from oxidation and erosion by the beam, so that the cones or pillars remaining after texturing are wider than they would otherwise be. To some extent, the dimensions of the hills and the distances between them can be tailored through choice of the thickness of the aluminum coat and/or the oxygen-beam fluence. The figure illustrates an example of texturing of the tip of a PMMA optical fiber without and with prior aluminum coating.

Banks, Bruce A.↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

On the use of a multiple beam optical sensor for in situ curvature monitoring in liquids

Several methods have been developed since the early 1900 to extract thin film stresses from the curvature of the substrate to which it is attached. One robust method particularly suitable for in situ curvature monitoring is the multiple beam optical sensor, which consists in measuring the change in relative spacings between parallel laser beams reflecting off the curved substrate. Although the technique is already well established for curvature monitoring in low pressure, gaseous environments, its use in liquid media has not yet received similar attention. Moreover, in the majority of the published work so far, spot spacings have been assumed to depend linearly on curvature. In this paper, it is first shown that this assumption may induce significant errors, particularly at large curvature. A more accurate set of equations is proposed. Next, the relationship between spot spacings and curvature is established when the substrate of interest is in a liquid, and a constitutive formula is proposed in that case as well. Finally, some practical aspects of the multiple beam technique for performing curvature measurements in a liquid are discussed. Various factors disturbing the measurement resolution are identified, with a specific interest for thin film anodizing, and a cell design is proposed to minimize their effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prototype Wire Position Monitoring System

The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1{micro}m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1{micro}m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

43 PARTICLE ACCELERATORS↗

The T2K beam line and near detectors

The goal of the Tokai-to-Kamioka (T2K) experiment is to measure the last undiscovered neutrino oscillation parameter {theta}{sub 13} and determine precisely the value of {theta}{sub 23} and {delta}m{sub 23}{sup 2}. This proceeding describes the T2K baseline and emphasises on the role of the beam line and near detectors. Performances of the on-axis neutrino beam flux monitor and off-axis neutrino detector system are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feasibility of OTR imaging of non-relativistic ions at GSI

The feasibility of using the optical transition radiation (OTR) generated as a 11.4- to 300-MeV/u ion beam passes through a single metal conducting plane for a minimally intercepting beam profile monitor for GSI/Darmstadt has been evaluated for the first time. Although these are non-relativistic beams, their beta and gamma values are similar to the 80-keV electron-beam imaging studies previously done on the CTF3 injector. With anticipated beam intensities of 10{sup 9} to 10{sup 11} particles per pulse and the predicted charge-squared dependence of OTR, the ion charge state becomes a critical factor for photon production. The OTR signal from the ion charge integrated over the video field time should be comparable to or larger than the CTF3 electron case. These signal strengths will allow a series of experiments to be done that should further elucidate the working regime of this technique.

43 PARTICLE ACCELERATORS↗

Surveillance and diagnostics of the beam mode vibrations of the Ringhals PWRs

Surveillance of core barrel vibrations has been performed in the Swedish Ringhals PWRs for several years. This surveillance is focused mainly on the pendular motion of the core barrel, which is known as the beam mode. The monitoring of the beam mode has suggested that its amplitude increases along the cycle and decreases after refuelling. In the last 5 years several measurements have been taken in order to understand this behaviour. Besides, a non-linear fitting procedure has been implemented in order to better distinguish the different components of vibration. By using this fitting procedure, two modes of vibration have been identified in the frequency range of the beam mode. Several results coming from the trend analysis performed during these years indicate that one of the modes is due to the core barrel motion itself and the other is due to the individual flow induced vibrations of the fuel elements. In this work, the latest results of this monitoring are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-504: Intensity-Modulated Radiosurgery Treatments Derived by Optimizing Delivery of Sphere Packing Treatment Plans

Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-process dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.

60 APPLIED LIFE SCIENCES↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗

A review of various methods of detecting and measuring beam halos

Halos in high energy particle beams require constant monitoring to minimise beam losses and damage to accelerator components. Four methods of measuring halos are described: wire scanner, laser wire scanner, diamond detector and halo masking monitors. Details of their effectiveness’ from tests at various accelerators are used to evaluate how useful they are. It is found that methods making use of wire and laser wire scanners are unable to achieve a high enough dynamic range to measure the outer halo, where the intensity of particles is very low. Diamond detectors can be used to determine the presence of a halo, but are unable to reconstruct their shape. The halo masking method, which makes use of a digital micromirror device to block out high intensity light, produces very good results, but it is possible that light is scattered inside the phosphor screen used to produce an image from the beam, skewing the measurements.

43 PARTICLE ACCELERATORS↗

PHASE DAMPING IN THE SNS LINAC

Synchronous phase oscillations and the beam phase adiabatic damping curves in the SNS linac are studied with linac models and measured with all the linac beam phase monitors. This study provides a new beam diagnostic technique for detecting RF cavity phase and/or field amplitude errors in a linac with many independently phased cavities. The phase damping curves predicted in the linac longitudinal model could also be utilized to analyze the longitudinal lattice of the superconducting linac - in which each cavity gradient varies widely from the nominal design and a smooth longitudinal focusing is very important to preserve beam emittance in the linac.

43 PARTICLE ACCELERATORS↗

The ecloud measurement setup in the Main Injector

Ecloud has been observed in many high intensity accelerators which can limit the amount of current that can be stored in them. In particular, for ProjectX, the amount of beam current that will be stored in the MI (Main Injector) will be {approx}160 x 10{sup 12} protons while the present maximum intensity is {approx}45 x 10{sup 12} protons which is about 3.5x less beam. Although ecloud has been observed in the MI, it has not caused instabilities at the present running conditions. However, there is no guarantee that instabilities caused by ecloud will not be a problem at ProjectX intensities. Therefore, a program has been started to study the ecloud effects with both computer simulations and experiments. In this paper, we will be focusing our attention on how coatings can affect the production of secondary electrons. We have installed an ecloud measurement setup in a straight section of MI which consists of one coated and one uncoated beam pipe with the same physical dimensions and at the same location, together with four retarding field analyzers (RFAs) and three sets of beam position monitors (BPMs) which can be used for the microwave measurements. An ecloud measurement setup was installed in a straight section of the Main Injector in 2009. The goal of the setup was to compare the characteristics of different beam pipe coatings when subjected to proton beam. The setup consists of one coated and one uncoated beam pipe with the same physical dimensions installed at the same location. Four RFAs (retarding field analyzers) and three BPMs (beam position monitors) used for microwave measurements have been used to measure the ecloud densities. The RFAs have performed very well and have collected both the time evolution and energy distribution of the ecloud for bare and two types of beam pipe coatings.

43 PARTICLE ACCELERATORS↗

BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used to measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.

43 PARTICLE ACCELERATORS↗

SU-E-T-47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator

Purpose: To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV. Methods: The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.9.6. The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane-parallel ionization chambers, and a spot-position monitor consisted of a multiwire ionization chamber. A water phantom is located with its upstream surface at the isocenter plane. The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy. The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded. PSF is used to analyze the pencil beam features and offset the pencil beam position. The source model parameters are verificated by fitting the simulated Result to the measurement. Results: The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement. Generally the distance to agreement (DTA) of Bragg peaks is less than 0.2cm. The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm. Conclusion: A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator. This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗