Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

An Advanced Open-Source Platform for Air Quality Analysis, Visualization, and Prediction

Ambient air pollution is the largest environmental health risk factor, leading to several million premature deaths globally per year. The challenge of combating poor air quality is exacerbated by growing urban populations, changing emissions, and a warming climate. While there have been many advances monitoring and modeling of atmospheric composition, reflected in the dramatic increase in archived Earth Observations, there is no single measurement or method that alone can provide an accurate depiction of the entire atmosphere. The rapidly growing collections of observational and modeling data require us to be smarter about what data to include, and how such data is used. In recent years, NASA has invested significantly in advancing the concepts for Analytics Collaborative Framework (ACF) [5] and New Observing Strategies (NOS) [4] to tackle our software infrastructure need for harmonized data management and dynamic acquisition of diverse measurements for on-demand, interactive, multivariate analysis, and access [3]. It is not enough to have a big data, standalone analytics solution; it is critical that we start integrating data from remote sensing, modeling, and in-situ networks in a harmonized manner that enables timely and data-driven decision-making for air quality management. This work presents the design and development of an Air Quality Analytics Collaborative Framework (AQ ACF), as part of NASA’s Advanced Information Systems Technology (AIST) effort, to establish a data, machine-learning, and numerically driven platform for air quality analysis, visualization, and prediction.

Liu, Qian↗

Multi-source energy harvester to power sensing hardware on rotating structures

The U.S. Department of Energy (DOE) proposes to meet 20% of the nation's energy needs through wind power by the year 2030. To accomplish this goal, the industry will need to produce larger (> 100m diameter) turbines to increase efficiency and maximize energy production. It will be imperative to instrument the large composite structures with onboard sensing to provide structural health monitoring capabilities to understand the global response and integrity of these systems as they age. A critical component in the deployment of such a system will be a robust power source that can operate for the lifespan of the wind turbine. In this paper we consider the use of discrete, localized power sources that derive energy from the ambient (solar, thermal) or operational (kinetic) environment. This approach will rely on a multi-source configuration that scavenges energy from photovoltaic and piezoelectric transducers. Each harvester is first characterized individually in the laboratory and then they are combined through a multi-source power conditioner that is designed to combine the output of each harvester in series to power a small wireless sensor node that has active-sensing capabilities. The advantages/disadvantages of each approach are discussed, along with the proposed design for a field ready energy harvester that will be deployed on a small-scale 19.8m diameter wind turbine.

42 ENGINEERING↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. electronic sensors. The system comprises any number of transmitting units and a single receiving unit. Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal-conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient temperature sensor that is in addition to the external thermocouples. The control module is a system-on-chip embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display. Each transmitting unit is battery-powered and can operate for at least seven days continuously while reporting temperatures every half hour. The receiving unit is powered by a wall-mounted transformer source. The receiving unit responds to each transmitting unit and reports the readings of each of the four thermocouples and of the ambient-temperature sensor of the transmitting unit. The end-to-end accuracy of the system is plus or minus 0.2 C over the temperature range from 0 to 100 C. The radio-communication range between the receiving and transmitting units is approximately equal to 0.5 mile (approximately equal to 0.8 km).

Solano, Wanda↗

Self-organized titanium oxide nano-channels for resistive memory application

Towards developing next generation scalable TiO{sub 2}-based resistive switching (RS) memory devices, the efficacy of 50 keV Ar{sup +}-ion irradiation to achieve self-organized nano-channel based structures at a threshold fluence of 5 × 10{sup 16} ions/cm{sup 2} at ambient temperature is presented. Although x-ray diffraction results suggest the amorphization of as-grown TiO{sub 2} layers, detailed transmission electron microscopy study reveals fluence-dependent evolution of voids and eventual formation of self-organized nano-channels between them. Moreover, gradual increase of TiO/Ti{sub 2}O{sub 3} in the near surface region, as monitored by x-ray photoelectron spectroscopy, establishes the upsurge in oxygen deficient centers. The impact of structural and chemical modification on local RS behavior has also been investigated by current-voltage measurements in conductive atomic force microscopy, while memory application is manifested by fabricating Pt/TiO{sub 2}/Pt/Ti/SiO{sub 2}/Si devices. Finally, the underlying mechanism of our experimental results has been analyzed and discussed in the light of oxygen vacancy migration through nano-channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cascade variable-conductance heat pipe (A0076)

The objective is to verify the capability of a cascade variable conductance heat pipe (CVCHP) system to provide precise temperature control of long life spacecraft without the need for a feedback heater or other power sources for temperature adjustment under conditions of widely varying power input and ambient environment. Solar energy is the heat source and space the heat sink for thermally loading two series connected variable conductance heat pipes. Electronics and power supply equipment requirements are minimal. A 7.5 V lithium battery supplies the power for thermistor type temperature sensors for monitoring system performance, and a 28 V lithium battery supplies power for valve actuation.

Grote, M. G.↗

Field Experiments and Model Validation: The EGS Collab Project

Implementing enhanced geothermal systems (EGS) will require improvements in understanding stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The US Department of Energy (DOE) is addressing these and other challenges at multiple scales. The EGS Collab project, addressed here, is performing tests and modeling at the 10 m scale. The FORGE project is performing tests at the full reservoir scale. The EGS Collab team created an underground testbed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently building a second testbed at SURF at a depth of about 1.25 km aimed at investigating shear stimulation (Experiment 2). In Experiment 1, we drilled eight boreholes in a well-characterized phyllite and installed geophysical sensors in six of them to create a well-instrumented testbed to allow careful monitoring of stimulation events and flow tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results both in near-real-time and in detailed process studies. Stimulations performed in this testbed allowed quantification of processes occurring during stimulation and the examination of dynamic flow occurrences. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Our second testbed, targeted at shear stimulation, is currently being built at the SURF Facility at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1.

artificial intelligence↗

Liquid hydrogen pump performance and durability testing through repeated cryogenic vessel filling to 700 bar

Here, this paper reports the results of a comprehensive test of liquid hydrogen (LH 2 ) pump performance and durability conducted while cycle testing a prototype thin-lined cryogenic pressure vessel 456 times to 700 bar. This extensive LH2 pump experimental data set provides a wealth of information vital for a complete evaluation of the future potential of this promising technology for ambient temperature and cryo-compressed vessel refueling. The experiment was conducted at Lawrence Livermore National Laboratory (Livermore, CA)'s hydrogen test facility, specifically built for this experiment and including a containment vessel for safe testing of the prototype vessel and a control room for efficient monitoring. Original pump and storage instrumentation was complemented with an electric power analyzer and a boil-off mass flow meter for more complete pump characterization. The results of the experiment confirm most of the expected virtues of the LH 2 pump: rapid (3 min) refueling of the 65-liter prototype vessel at high flow rate (1.55 kgH 2 per minute on average), unlimited back to back refueling, low electricity consumption (1.1 kWh/kg H 2 ), no measurable degradation, and low maintenance. High cryogenic vessel fill density is another key performance metric that was demonstrated in an earlier publication. These virtues derive from the high density of LH 2 enabling pressurization to high density with relatively little energy consumption and high throughput from a small displacement pump. Boil-off losses as high as 27.7% of dispensed hydrogen were measured, at experimental conditions not representative of operation at a hydrogen refueling station. These losses drop to 15.4% for operation that may be representative of a small station (332 kg/day), while we anticipate less than 6% boil-off with the existing pump and Dewar with improved LH 2 delivery truck operations and a more favorable arrangement of the LH 2 pump relative to the Dewar.

08 HYDROGEN↗

In situ Bragg coherent X-ray diffraction imaging of corrosion in a Co–Fe alloy microcrystal

Corrosion is a major concern for many industries, as corrosive environments can induce structural and morphological changes that lead to material dissolution and accelerate material failure. The progression of corrosion depends on nanoscale morphology, stress, and defects present. Experimentally monitoring this complex interplay is challenging. Here we implement in situ Bragg coherent X-ray diffraction imaging (BCDI) to probe the dissolution of a Co-Fe alloy microcrystal exposed to hydrochloric acid (HCl). By measuring five Bragg reflections from a single isolated microcrystal at ambient conditions, we compare the full three-dimensional (3D) strain state before corrosion and the strain along the [111] direction throughout the corrosion process. We find that the strained surface layer of the crystal dissolves to leave a progressively less strained surface. Interestingly, the average strain closer to the centre of the crystal increases during the corrosion process. We determine the localised corrosion rate from BCDI data, revealing the preferential dissolution of facets more exposed to the acid stream, highlighting an experimental geometry effect. These results bring new perspectives to understanding the interplay between crystal strain, morphology, and corrosion; a prerequisite for the design of more corrosion-resistant materials.

36 MATERIALS SCIENCE↗

PV Module Operating Temperature - Data and Resources

The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.

14 SOLAR ENERGY↗

Fungal degradation of fiber-reinforced composite materials

As described in a previous report, a fungal consortium isolated from degraded polymeric materials was capable of growth on presterilized coupons of five composites, resulting in deep penetration into the interior of all materials within five weeks. Data describing the utilization of composite constituents as nutrients for the microflora are described in this article. Increased microbial growth was observed when composite extract was incubated with the fungal inoculum at ambient temperatures. Scanning electron microscopic observation of carbon fibers incubated with a naturally developed population of microorganisms showed the formation of bacterial biofilms on the fiber surfaces, suggesting possible utilization of the fiber chemical sizing as carbon and energy sources. Electrochemical impedance spectroscopy was used to monitor the phenomena occurring at the fiber-matrix interfaces. Significant differences were observed between inoculated and sterile panels of the composite materials. A progressive decline in impedance was detected in the inoculated panels. Several reaction steps may be involved in the degradation process. Initial ingress of water into the resin matrix appeared to be followed by degradation of fiber surfaces, and separation of fibers from the resin matrix. This investigation suggested that composite materials are susceptible to microbial attack by providing nutrients for growth.

Environmental Microbiology↗

Ambient Aerosol Is Physically Larger on Cloudy Days in Bondville, Illinois

Particle chemical composition affects aerosol optical and physical properties in ways important for the fate, transport, and impact of atmospheric particulate matter. For example, hygroscopic constituents take up water to increase the physical size of a particle, which can alter the extinction properties and atmospheric lifetime. At the collocated AERosol RObotic NETwork (AERONET) and Interagency Monitoring of PROtected Visual Environments (IMPROVE) network monitoring stations in rural Bondville, Illinois, we employ a novel cloudiness determination method to compare measured aerosol physicochemical properties on predominantly cloudy and clear sky days from 2010 to 2019. On cloudy days, aerosol optical depth (AOD) is significantly higher than on clear sky days in all seasons. Measured angstrom ngstro''m exponents are significantly smaller on cloudy days, indicating physically larger average particle size for the sampled populations in all seasons except winter. Mass concentrations of fine particulate matter that include estimates of aerosol liquid water (ALW) are higher on cloudy days in all seasons but winter. More ALW on cloudy days is consistent with larger particle sizes inferred from angstrom ngstro''m exponent measurements. Aerosol chemical composition that affects hygroscopicity plays a determining impact on cloudy versus clear sky differences in AOD, angstrom ngstro''m exponents, and ALW. This work highlights the need for simultaneous collocated, high-time-resolution measurements of both aerosol chemical and physical properties, in particular at cloudy times when quantitative understanding of tropospheric composition is most uncertain.

54 ENVIRONMENTAL SCIENCES↗

High Temperature Capacitor Development

The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as temperature, pressure, heading, etc. Commercial off-the-shelf electronics are not specified to meet these operating conditions. This is due to problems associated with all aspects of the electronics including the resistors and capacitors. With respect to capacitors, increasing temperature often significantly changes capacitance because of the strong temperature dependence of the dielectric constant. Higher temperatures also affect the equivalent series resistance (ESR). High-temperature capacitors usually have low capacitance values because of these dielectric effects and because packages are kept small to prevent mechanical breakage caused by thermal stresses. Electrolytic capacitors do not operate at temperatures above 150oC due to dielectric breakdown. The development of high-temperature capacitors to be used in a high-pressure high-temperature (HPHT) drilling environment was investigated. These capacitors were based on a previously developed high-voltage hybridized capacitor developed at Giner, Inc. in conjunction with a unique high-temperature electrolyte developed during the course of the program. During this program the feasibility of operating a high voltage hybridized capacitor at 230oC was demonstrated. Capacitor specifications were established in conjunction with potential capacitor users. A method to allow for capacitor operation at both ambient and elevated temperatures was demonstrated. The program was terminated prior to moving into Phase II due to a lack of cost-sharing funds.

03 NATURAL GAS↗

West Valley Demonstration Project Annual Site Environmental Report (CY2019)

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2019. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2019 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2017

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2017. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2017. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2017 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permafrost Active Layer Seismic Interferometry Experiment (PALSIE).

We present findings from a novel field experiment conducted at Poker Flat Research Range in Fairbanks, Alaska that was designed to monitor changes in active layer thickness in real time. Results are derived primarily from seismic data streaming from seven Nanometric Trillium Posthole seismometers directly buried in the upper section of the permafrost. The data were evaluated using two analysis methods: Horizontal to Vertical Spectral Ratio (HVSR) and ambient noise seismic interferometry. Results from the HVSR conclusively illustrated the method's effectiveness at determining the active layer's thickness with a single station. Investigations with the multi-station method (ambient noise seismic interferometry) are continuing at the University of Florida and have not yet conclusively determined active layer thickness changes. Further work continues with the Bureau of Land Management (BLM) to determine if the ground based measurements can constrain satellite imagery, which provide measurements on a much larger spatial scale.

54 ENVIRONMENTAL SCIENCES↗

Recommendations of the panels: Panel on in-flight measurements

The attenuation factor for aircraft other than the B-747 in reducing the ambient ozone concentrations which enter the cabin is obtained. The need to continue NASA Global Air Sampling Program measurements was expressed for three main purposes; testing new filters, correlation of complaints with ozone levels, and ambient ozone data. The need to continue cooperation between NASA and industry is indicated. Concern with regard to the correlation of ozone levels and complaints was given. The need to measure the variability of ozone within the aircraft cabin was investigated. The requirement for an onboard ozone monitor on all aircraft is discussed.

Rogers, J.↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

Decomposition of NH3BH3 at sub-ambient pressures: A combined thermogravimetry-differential thermal analysis-mass spectrometry study

We report a systematic study of the isothermal decomposition of ammonia borane, NH3BH3, at 363 K as a function of argon pressure ranging between 50 and 1040 mbar using thermogravimetry and differential thermal analysis coupled with mass analysis of the volatile species. During thermal aging at 363 K, evolution of hydrogen, aminoborane and borazine is monitored, with the relative mass loss strongly depending on the pressure in the reaction chamber. Furthermore, the induction period required for hydrogen release at 363 K decreases with decreasing pressure.

08 HYDROGEN↗